IEC/SC 45B - IEC_SC_45B
To prepare standards that address instrumentation used for: - the measurement of ionizing radiation in the workplace, to the public, and in the environment for radiation protection purposes; - illicit trafficking detection and identification of radionuclides; - radiation-based security screening.
IEC_SC_45B
To prepare standards that address instrumentation used for: - the measurement of ionizing radiation in the workplace, to the public, and in the environment for radiation protection purposes; - illicit trafficking detection and identification of radionuclides; - radiation-based security screening.
General Information
IEC 61577-3:2011 describes the specific requirements for instruments measuring the volumetric activity of airborne short-lived radon decay products and/or their ambient potential alpha-energy concentration outdoors, in dwellings, and in workplaces including underground mines. This standard applies practically to all types of electronic instruments that are based on grab sampling, continuous sampling technique and electronic integrating measurement methods. This new edition includes the following significant technical changes with respect to the previous edition: - implementation of new requirements and tests concerning radiation detection performance; - implementation of new requirements and tests concerning environmental performance; - harmonization of the requirements and tests concerning electrical and mechanical performance with other standards in the area of radiation protection instrumentation.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61577-4:2009 concerns the System for Test Atmospheres with Radon (STAR) needed for testing, in a reference atmosphere, the instruments measuring radon and RnDP. Provides guidance for those facing problems associated with the production of equipment for setting up reference atmospheres for radon and its decay products.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60846-1:2009 specifies the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47. Applies to dose equivalent (rate) meters and/or monitors for the measurement of ambient dose equivalent (rate) and/or directional dose equivalent (rate) from external beta, X and gamma radiation.
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61526:2010 specifies general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This new edition includes the following significant technical changes with regard to the previous one: - improved determination of constancy of the dose response and statistical fluctuations; - abolition of classes of personal dose equivalent meters in relation to retention of stored information; - inclusion of usage categories of personal dosemeters.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62363:2008 is applicable to portable and transportable contamination meters and monitors designed for the direct measurement or the direct detection of surface contamination by photon radiation emitting radionuclides. Lays down standard requirements and gives examples of acceptable methods, and also specifies general characteristics, general test conditions, radiation characteristics, electrical safety, environmental characteristics, and the requirements of the identification certificate for photon contamination meters and monitors.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
Defines technical requirements for equipment for monitoring of alpha-, beta- or gamma-emitting radionuclides in liquid effluents and surface waters, provides general guidance as to the possible detection capability of such equipment and indicates when and where its uses may be practicable.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
Defines mechanical and operational characteristics, minimum performance characteristics and general test procedures for personnel monitoring equipment. Applies to contamination warning assemblies, meters and monitors used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or not.
- Standard56 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies the classification, general design requirements, performance characteristics and test procedures for in vivo counting systems for detecting trace amounts of radionuclides in the bodies of persons working in nuclear power plants, laboratories and facilities handling radionuclides, and inhabitants living on territory which may be contaminated. The purpose is to determine the dose equivalent to organs and the effective dose of internal radiation for the whole body.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
Establishes specific standard requirements, including technical characteristics and general test conditions, and gives examples of acceptable methods for aerosol effluent monitors.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down mandatory general requirements and gives examples of acceptable methods for equipment for continuous monitoring of radioactivity in gaseous effluents. Specifies general characteristics, general test procedures, radiation, electrical, safety and environmental characteristics and the identification and certification of the equipment.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down specific standard requirements, including technical characteristics and general test conditions, and gives examples of acceptable methods for noble gas effluent monitors.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down specific standard requirements, including technical characteristics and general test conditions, and gives examples of acceptable methods for iodine monitors.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
Establishes specific standard requirements, including technical characteristics and general test conditions and gives examples of acceptable methods for the tritium effluent monitors.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
Defines an installed monitor for the control and detection of radioactivity of gamma emitters contained in recyclable or non-recyclable materials transported by vehicle, the conceptual requirements, general characteristics, mechanical characteristics, environmental conditions, minimal requirements, test procedures and documentation.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down standard requirements and gives examples of acceptable methods, and also specifies general characteristics, general test conditions, radiation characteristics, electrical safety, environmental characteristics, and the requirements of the identification certificate for alpha, beta and alpha/beta contamination meters and monitors.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62387:2012 applies to all kinds of passive dosimetry systems that are used for measuring the personal dose equivalent (for whole body dosimetry), the personal dose equivalent (for eye lens dosimetry), the personal dose equivalent (for both whole body and extremity dosimetry), the ambient dose equivalent (for environmental dosimetry), or the directional dose equivalent (for environmental dosimetry). This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in wide energy ranges. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
- Standard107 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to dosimetry systems that are capable of evaluating doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The only correction that may be applied to the evaluated dose (indicated value) is the one resulting from natural background radiation using extra dosemeters.
- Standard68 pagesEnglish languagesale 10% offe-Library read for1 day
Defines the performance of installed monitors used for the detection of gamma and neutron radiation emitters contained in objects/ containers or vehicles, general characteristics, mechanical characteristics, environmental requirements, test procedures and documentation. Such monitors are used to monitor vehicles, cargo containers, people, or packages and are typically located at national and international borders, but may be used at any location where there is a need for this type of monitoring.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for the dosemeter and, if supplied, for its associated readout system. Specifies general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. Also specifies classes of personal dose equivalent meters in relation to retention of stored information.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for the performance characteristics of neutron ambient dose equivalent (rate) meters, and prescribes the methods of testing in order to determine compliance with this standard. Specifies general characteristics, general test procedures, radiation characteristics, electrical, mechanical, safety and environmental characteristics, and also the identification certificate
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47.
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
Lays down mandatory requirements and gives examples of acceptable methods for measuring and monitoring equipment to enable the determination of the average value of the concentration of atmospheric tritium in working areas and its variation as a function of time, and to actuate an alarm system if necessary.
- Standardization document33 pagesEnglish languagesale 10% offe-Library read for1 day