Radiation protection instrumentation - Neutron ambient dose equivalent (rate) meters

Specifies requirements for the performance characteristics of neutron ambient dose equivalent (rate) meters, and prescribes the methods of testing in order to determine compliance with this standard. Specifies general characteristics, general test procedures, radiation characteristics, electrical, mechanical, safety and environmental characteristics, and also the identification certificate

Strahlenschutz-Messgeräte - Umgebungs-Äquivalentdosis(leistungs)-Messgeräte für Neutronenstrahlung

Instrumentation pour la radioprotection - Appareils de mesure de l'équivalent de dose ambiant neutron (ou de son débit d'équivalent de dose)

Spécifie les caractéristiques exigées pour les instruments de mesure de l'équivalent de dose ambiant neutron (ou du débit) et décrit les méthodes d'essai mises en oeuvre pour démontrer la conformité à cette norme. Spécifie les caractéristiques générales, les procédures générales d'essai, les caractéristiques sous rayonnement, électriques, mécaniques, les caractéristiques de sécurité et environnementales et le certificat d'identification

Oprema za zaščito pred sevanjem – Merilniki ekvivalentne doze v prostoru za nevtronsko sevanje

General Information

Status
Withdrawn
Publication Date
17-Nov-2004
Withdrawal Date
30-Sep-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
14-Nov-2019
Completion Date
14-Nov-2019

Relations

Buy Standard

Standard
EN 61005:2005
English language
45 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 61005:2005

STANDARD
julij 2005
Oprema za zaščito pred sevanjem – Merilniki ekvivalentne doze v prostoru za
nevtronsko sevanje
Radiation protection instrumentation – Neutron ambient dose equivalent (rate)
meters
ICS 13.280; 17.240 Referenčna številka
SIST EN 61005:2005(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 61005
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2004

ICS 13.280


English version


Radiation protection instrumentation –
Neutron ambient dose equivalent (rate) meters
(IEC 61005:2003, modified)


Instrumentation pour la radioprotection - Strahlenschutz-Messgeräte -
Appareils de mesure de l'équivalent Umgebungsäquivalentdosis(leistungs-)
de dose ambiant neutron Messgeräte für Neutronenstrahlung
(ou de son débit d'équivalent de dose) (IEC 61005:2003, modifiziert)
(CEI 61005:2003, modifiée)



This European Standard was approved by CENELEC on 2004-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 61005:2004 E

---------------------- Page: 2 ----------------------

EN 61005:2004 - 2 -

Foreword

The text of the International Standard IEC 61005:2003, prepared by SC 45B, Radiation
protection instrumentation, of IEC TC 45, Nuclear instrumentation, together with the common
modifications prepared by the CENELEC BTTF 111-3, Instrumentation for ionizing radiation
measurement and protection, was submitted to the formal vote and was approved by
CENELEC as EN 61005 on 2004-10-01.

The following dates are proposed:

– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-10-01

– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-10-01

Clauses, Subclauses, tables and figures which are additional to those in IEC 61005 are
prefixed “Z”.

Annex ZA has been added by CENELEC.

__________

---------------------- Page: 3 ----------------------

- 3 - EN 61005:2004
Endorsement notice

The text of the International Standard IEC 61005:2003 was approved by CENELEC as a
European Standard with agreed common modifications as given below.

COMMON MODIFICATIONS

1 Scope and object
First paragraph, item b):
Add a NOTE:
NOTE Z  If the Equipment consists of separate detector and measurement assemblies the cable between the
two shall be that specified by the manufacturer. If the connection is by other means (e.g. radio waves,
infrared) or other cables, it is necessary to apply additional requirements with respect to the specific media.

2 Normative references
See Annex ZA
Correct titles of documents (e.g. ISO 8529-2:2000 and ISO 8529-3:1998).
Add EN 55011 (CISPR 11).

4 General characteristics of the measuring assemblies
4.4 Second paragraph, item b):
Replace at the end of the paragraph “… the effective range shall extend from
-1 -1
1,0 µSv h to 99,9 mSv h ) ” by “… the effective range shall extend from 1,0 to
99,9)”.
Add a new subclause after 4.4:
4.Z1 Classification dependent on expected condition of use
An assembly for the measurement of neutron ambient dose equivalent (rate) should
be classified, depending on its weight and the mode of use, in one of those three
categories:
− fixed station;
− mobile station;
− hand held.
For any hand held apparatus, the maximum necessary measurement time needed for
the measurement accuracy (in accordance with the defined performances) has t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.