WG 12 - TC 65/SC 65C/WG 12
TC 65/SC 65C/WG 12
General Information
IEC 61784-3-13:2021 specifies a safety communication layer (services and protocol) based on CPF 13 of IEC 61784 2 and IEC 61158 Type 13. It identifies the principles for functional safety communications defined in IEC 61784 3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.
NOTE 1 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres. This document defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 (all parts) for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery. This document provides guidelines for both developers and assessors of compliant devices and systems.
- Standard422 pagesEnglish and French languagesale 15% off
IEC 61784-3-2:2021 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784 1, IEC 61784 2 and IEC 61158 Type 2. It identifies the principles for functional safety communications defined in IEC 61784 3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.
NOTE 1 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres.
This document defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 (all parts) for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery. This document provides guidelines for both developers and assessors of compliant devices and systems.
- Standard579 pagesEnglish and French languagesale 15% off
IEC 61784-3-8:2021 specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784 1, IEC 61784-2 and IEC 61158 Type 18 and Type 23. It identifies the principles for functional safety communications defined in IEC 61784 3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.
NOTE 1 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres.
This document defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 (all parts) for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery. This document provides guidelines for both developers and assessors of compliant devices and systems.
- Standard221 pagesEnglish and French languagesale 15% off
IEC 61784-3-3:2021 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP 3/6) and IEC 61158 Types 3 and 10. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.
NOTE 1 It does not cover electrical safety and intrinsic safety aspects. Electrical safety relates to hazards such as electrical shock. Intrinsic safety relates to hazards associated with potentially explosive atmospheres.
This document defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 (all parts) for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery.
This document provides guidelines for both developers and assessors of compliant devices and systems.
NOTE 2 The resulting SIL claim of a system depends on the implementation of the selected functional safety communication profile within this system – implementation of a functional safety communication profile according to this document in a standard device is not sufficient to qualify it as a safety device.
- Standard300 pagesEnglish and French languagesale 15% off
IEC 61784-3:2021 explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance with the requirements of IEC 61508 (all parts) for functional safety. These principles are based on the black channel approach. They can be used in various industrial applications such as process control, manufacturing automation and machinery.
- Standard210 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 61784-3-12:2010 specifies a safety communication layer (services and protocol) based on CPF 12 of IEC 61784-2 and IEC 61158 Type 12. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This bilingual version (2012-02) corresponds to the monolingual English version, published in 2010-06.
- Standard203 pagesEnglish and French languagesale 15% off
IEC 61784-3:2016 is available as IEC 61784-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61784-3:2016 series explains some common principles that can be used in the transmission of safety-relevant messages among participants within a distributed network which use fieldbus technology in accordance with the requirements of IEC 61508 series for functional safety. These principles are based on the black channel approach. They can be used in various industrial applications such as process control, manufacturing automation and machinery. This part and the IEC 61784-3-x parts specify several functional safety communication profiles based on the communication profiles and protocol layers of the fieldbus technologies in IEC 61784-1, IEC 61784-2 and the IEC 61158 series. These functional safety communication profiles use the black channel approach, as defined in IEC 61508. These functional safety communication profiles are intended for implementation in safety devices exclusively. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- clarifications and additional explanations for requirements, updated references;
- deletion of technical overviews of profiles (Clauses 6 to 13), and associated dedicated subclauses for terms, definitions, symbols and abbreviations;
- addition of profiles for Communication Profile Families 8, 17 and 18 (Clauses 10, 14, 15);
- clarifications of models in Annex A;
- Annex B changed from informative to normative;
- addition of a new informative Annex E describing models for explicit and implicit FSCP mechanisms;
- addition of a new informative Annex F introducing an extended model for estimation of the total residual error rate;
- updates in parts for CPF 1, CPF 2, CPF 3, CPF 8, CPF 13 (details provided in the parts);
- addition of a new part for CPF 17.
- Standard166 pagesEnglish and French languagesale 15% off
- Standard30 pagesEnglish and French languagesale 15% off
IEC 61784-3-17:2016 specifies a safety communication layer (services and protocol) based on CPF 17 of IEC 61784-2 (CP 17/1) and IEC 61158 Type 21. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only.
- Standard146 pagesEnglish and French languagesale 15% off
IEC 61784-3-8:2016 specifies a safety communication layer (services and protocol) based on CPF 8 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 18 and Type 23. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Added FSCP 8/2;
- Added FSCP 8/2 Clause 12;
- Added content for FSCP 8/2 to Clauses 1 to 3 (scope, references, terms);
- Moved previous FSCP 8/1 to Clause 11 (demoting all old heading levels by one);
- Restructured old Clauses 4 to 10 to point to appropriate subclauses as appropriate.
- Standard215 pagesEnglish and French languagesale 15% off
IEC 61784-3-13:2016 specifies a safety communication layer (services and protocol) based on CPF 13 of IEC 61784-2 and IEC 61158 Type 13. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. The main changes with respect to the previous edition are listed below:
- change of trade name to openSAFETY;
- addition of Slim Safety PDU;
- addition of SOD CRC;
- addition of SSDO block transfer services;
- addition of connection valid bit to SPDO;
- addition of number of retries for reset guarding;
- addition of user parameters that are writeable at any time;
- corrections and editorial improvements.
- Standard391 pagesEnglish and French languagesale 15% off
IEC 61784 3-2:2016 specifies a safety communication layer (services and protocol) based on CPF 2 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 2. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. The main changes with respect to the previous edition are listed below (and highlighted in yellow in this document):
- Added detailed requirements for use of FSCP 2/1 in conjunction with CP 16/3 (see 4.1, 6.4.3, 6.5.3, 8.2, 8.13, and miscellaneous references when referencing CPF 2 networks);
- Defined object class section keywords for safety to EDS file definition in 8.10.2.1;
- New sections on safety CRC overview in 7.1.2.1 and Rollover counts for EF format in 7.4;
- Corrections to PFH calculations in 9.5.2;
- Change from MACID to NodeID as general reference to network identifier.
- Standard584 pagesEnglish and French languagesale 15% off
IEC 61784-3-3:2016 specifies a safety communication layer (services and protocol) based on CPF 3 of IEC 61784-1, IEC 61784-2 (CP 3/1, CP 3/2, CP 3/4, CP 3/5 and CP 3/6) and IEC 61158 Types 3 and 10. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This safety communication layer is intended for implementation in safety devices only. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Legacy V1-mode removed from this protocol edition;
- Protocol extensions to protect against possible loopbacks (LP extensions);
- Protocol extensions to keep SIL3 for safety networks with large numbers of participants (XP extensions) and subsequent new F-Parameter "F_CRC_Seed";
- Introduction of random and disjoint Codename based MonitoringNumbers (MNR) besides to the previous Consecutive Numbers;
- Provisions for Channel Granular Passivation and subsequent new F-Parameter "F_Passivation";
- GSD extensions due to new F-Parameters;
- Notations according to the CP3 family in IEC 61158 (e.g. IO Controller);
- Additional diagnosis message types;
- Diverse error corrections and fixes of typos;
- Updated documents in bibliography.
- Standard302 pagesEnglish and French languagesale 15% off
IEC 61784 3-6:2010 specifies a safety communication layer (services and protocol) based on CPF 6 of IEC 61784-1, IEC 61784-2 and IEC 61158 Type 8. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This part defines mechanisms for the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 series for functional safety. These mechanisms may be used in various industrial applications such as process control, manufacturing automation and machinery. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. The main changes with respect to the previous edition are: updates in relation with changes in IEC 61784 3. This bilingual version published in 2011-11, corresponds to the English version published in 2010-07.
- Standard182 pagesEnglish and French languagesale 15% off
IEC 61784-3-14:2010 specifies a safety communication layer (services and protocol) based on CPF 14 of IEC 61784-2 and IEC 61158 Type 14. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This bilingual version (2012-02) corresponds to the monolingual English version, published in 2010-06.
- Standard152 pagesEnglish and French languagesale 15% off
IEC 61784-3:2010 explains some common principles than can be used in the transmission of safety-relevant messages among participants within a distributed network using fieldbus technology in accordance with the requirements of IEC 61508 series for functional safety. These principles can be used in various industrial applications such as process control, manufacturing automation and machinery. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes with respect to the previous edition are:
- clarifications and additional explanations for requirements, updated references;
- updates of definitions and requirements in relation with the new edition of IEC 61508;
- addition of a new informative Annex D providing an assessment guideline;
- updates in parts for CPF 1, CPF 2, CPF 3, CPF 6 (details provided in the parts);
- addition of new parts for CPF 8, CPF 12, CPF 13, CPF 14;
- in CPF parts, addition of an annex to provide information about test laboratories for testing and validating conformance of FSCP products.
This bilingual version published in 2011-12, corresponds to the English version published in 2010-07.
- Standard59 pagesEnglish languagesale 15% off
- Standard127 pagesEnglish and French languagesale 15% off
IEC 61784-3-1:2010 specifies a safety communication layer (services and protocol) based on CPF 1 of IEC 61784-1 and IEC 61158 Types 1 and 9. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. The main changes with respect to the previous edition are:
- updates in relation with changes in IEC 61784-3;
- adjustment of Figure 5;
- change of sequence number from two octets to four octets in 7.2.2 to match the final protocol from the consortium;
- addition of details for time synchronization in 7.2.4;
- addition of information for safety response time in 9.3;
- addition of information in constraints for calculation of system characteristics in 9.5.
- Standard67 pagesEnglish languagesale 15% off
- Standard143 pagesEnglish and French languagesale 15% off
IEC 61784-3-18:2011 specifies a safety communication layer (services and protocol) based on CPF 18 of IEC 61784-2 and IEC 61158 Type 22. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer.
- Standard271 pagesEnglish and French languagesale 15% off
- Standard125 pagesEnglish and French languagesale 15% off
- Standard20 pagesEnglish and French languagesale 15% off
Applies to radiotherapy simulators:[
]- that use diagnostic X-ray equipment to simulate physically a therapeutic radiation beam, so that the treatment volume to be subjected to irradiation during radiotherapy can be localized, and the position and size of the radiotherapy radiation field can be confirmed;[
]- intended exclusively for radiotherapy simulation as a prelude to intended radiotherapy, and not for any other purpose such as general diagnostic examinations.[
]Establishes requirements to ensure the ionizing radiation safety and enhanced mechanical and electrical safety of radiotherapy simulators; it identifies geometrical parameters that are critical for the accurate simulation of a radiotherapy treatment.[
]Cancels and replaces the first edition published in 1993 and its amendment 1 (1996).
- Standard12 pagesEnglish and French languagesale 15% off
IEC/TR 62685:2010 provides information about the assessment aspects of safe communication such as test beds, proof of increased interference immunity (EMC for functional safety), electrical safety, and other environmental requirements. It is only applicable to safety devices for functional safety communication which are developed according to IEC 61508 and IEC 61784-3 and covers general industrial environments such as defined in IEC 61131-2 or IEC 61000-6-2 and process automation environments such as those covered in the IEC 61326 series. Reference is made to the ERS (Equipment Requirements Specification) and/or SRS (Safety Requirements Specification) of a particular safety application to verify the necessary immunity of devices and systems according to IEC 61508. This bilingual version (2013-04) corresponds to the monolingual English version, published in 2010-12.
- Technical report29 pagesEnglish languagesale 15% off
- Technical report63 pagesEnglish and French languagesale 15% off