29.035.30 - Glass and ceramic insulating materials
ICS 29.035.30 Details
Glass and ceramic insulating materials
Glasisolierstoffe. Keramikisolierstoffe
Isolants electriques a base de verre et ceramique
Stekleni in keramični izolacijski materiali
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 29.035.30 - Glass and ceramic insulating materials
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
IEC 61196-6-3:2018(E) applies to coaxial communication cables described in IEC 61196-6. It specifies the requirements for 75-5 type CATV drop cables. These cables are used in CATV distribution systems, surveillance and control systems, satellite television receiving systems and as bidirectional hybrid fibre coax (HFC). The operating frequency is from 5 MHz to 3 000 MHz.
This part of IEC 61196 is to be used in conjunction with IEC 61196-1:2005 and IEC 61196 6:2009. It determines the layout and style with respect to the model and type.
- Standard12 pagesEnglish languagesale 15% off
This sheet of IEC 60454-3 contains the requirements for - glass fabric tapes with pressure-sensitive adhesive, - cellulose acetate woven fabric tapes with rubber thermosetting adhesive, - combined cellulose-viscose woven fabric tapes, one side covered with a thermoplastic material, the other side with thermosetting adhesive. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application, and not based on this specification alone.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
Gives the requirements for three types of E-type glass sleeving using either braided or knitted construction, with a continuous silicone elastomer coating and differentiated by their breakdown voltage (sheet 400: high breakdown voltage; sheet 401: medium breakdown voltage; sheet 402: low breakdown voltage). These sleevings have been found suitable for temperatures up to 180 °C.
Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Gives the requirements for glass textile fibre sleeving, uncoated, constructed from a braid of E-type yarn. The sleeving is annealed by heat treatment to assist in maintaining a circular cross-section. This sleeving is suitable for use at temperatures up to 350 °C. It is normally available in internal diameters between 0,5 mm and 30 mm and is normally supplied in its natural colour. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
Gives the requirements for E-type glass sleeving using either braided or knitted construction with a continuous flexible coating based on polyvinyl chloride (PVC) or its copolymers or blends thereof. These sleevings have been found suitable up to temperatures of 105 °C.
The sleeving is normally available with internal diameters between 0,3 mm and 25 mm and is normally supplied in the following colours : black, white, red, yellow, blue, brown, green, grey, orange, pink and green/yellow.
Sizes or colours other than those specifically listed in this standard may be available as custom items. These items shall be considered to comply with this standard if they comply with the other property requirements listed in Tables 2 and 5, except for dimensions, and, where applicable, in Table 3.
Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.
This edition has been aligned to reflect the changes made to the 2nd edition of IEC 60684-2, Test methods, and standardizes on a 100 mm long electrode for breakdown voltage.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
Gives the requirements for three types of E-type glass sleeving using either braided or knitted construction with a continuous acrylic based coating, and differentiated by their breakdown voltage: high breakdown voltage (sheet 403), medium breakdown voltage (sheet 404) and low breakdown voltage (sheet 405). These sleevings have been found suitable for use at temperatures up to 155 °C.
Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic, glass and glass-ceramic materials to be used for electrical insulation purposes. Specifies methods of test. Intended to provide test results typical of the material from which the test pieces are processed. Since, in the majority of cases, ceramic components for insulating purposes are of rather different size and shape to test pieces, the results of such tests provide only a guide to the actual properties of components. The limitations imposed by the method of forming and processing are discussed where relevant.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic, glass and glass-ceramic materials to be used for electrical insulation purposes. Specifies methods of test. Intended to provide test results typical of the material from which the test pieces are processed. Since, in the majority of cases, ceramic components for insulating purposes are of rather different size and shape to test pieces, the results of such tests provide only a guide to the actual properties of components. The limitations imposed by the method of forming and processing are discussed where relevant.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
Gives the requirements for E-type glass sleeving in a braided construction with a continuous polyurethane (PUR)-based coating with a thermal index of 155.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic, glass and glass-ceramic materials to be used for electrical insulation purposes. Specifies methods of test. Intended to provide test results typical of the material from which the test pieces are processed. Since, in the majority of cases, ceramic components for insulating purposes are of rather different size and shape to test pieces, the results of such tests provide only a guide to the actual properties of components. The limitations imposed by the method of forming and processing are discussed where relevant.
- Standard44 pagesEnglish languagesale 15% off
- Standard44 pagesFrench languagesale 15% off
- Standard87 pagesEnglish and French languagesale 15% off
Applicable to ceramic, glass-ceramic, glass-mica and glass materials for electrical insulating purposes giving a classification of materials and typical numerical values for the major characteristics.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
Gives methods of test for the materials defined in EN 61067-1.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Type 1 tapes are woven on conventional looms with glass fibres, type 2 tapes are woven on shuttle-less looms with glass fibres, type 3 tapes are woven on shuttle-less looms with warp glass fibres and weft polyester fibres.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic, glass-ceramic, glass-mica and glass materials for electrical insulating purposes giving a classification of materials and typical numerical values for the major characteristics.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for loomstate, continuous filament tapes woven on conventional or shuttleless looms from either glass fibres or a combination of glass and polyester fibres. The ranges of nominal sizes covered by this standard are: width: 10 mm to 50 mm, thickness: 0,05 mm to 0,40 mm.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
Gives definitions and classification for ceramic, glass, and glass-ceramic materials to be used for electrical insulation purposes.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for loomstate, continuous filament tapes woven on conventional or shuttleless looms from either glass fibres or a combination of glass and polyester fibres. The ranges of nominal sizes covered by this standard are: width: 10 mm to 50 mm, thickness: 0,05 mm to 0,40 mm.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
Gives methods of test for the materials defined in EN 61067-1.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic, glass-ceramic, glass-mica and glass materials for electrical insulating purposes giving a classification of materials and typical numerical values for the major characteristics.
- Standard13 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
Contains requirements for 3 types of pressure-sensitive adhesive tapes made with glass fabric. Products having thermal indices from 130 to 180 with rubber thermosetting adhesive, acrylic crosslinked and high temperature silicone adhesives.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with porosity tests, mechanical and electrical tests and with tests related to thermal properties. Limitations imposed by the method of forming and processing of test specimens are discussed.
- Standardization document23 pagesEnglish languagesale 10% offe-Library read for1 day
Gives requirements for sleeving constructed from a braid of E-type glass yarn. The sleeving is annealed by heat treatment to assist in maintaining a circular cross-section.
- Standardization document5 pagesEnglish languagesale 10% offe-Library read for1 day
This sheet gives requirements for E type glass sleeving using either braided or knitted construction with a continuous flexible coating based on polyvinyl chloride (PVC) or its co-polymers or blends thereof - The sleeving is normally available in bore sizes 0.3 mm to 25 mm and in the following colours: black - white - red - yellow - blue - brown - green - grey - orange - pink and green/yellow
- Standardization document7 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60684-3-400 to 402:2002
- Standardization document11 pagesEnglish languagesale 10% offe-Library read for1 day
This standard gives requirements for E type glass sleeving using either braided or knitted construction with a continuous acrylic based coating - The sleeving is normally available in bore sizes 0.5 mm to 25 mm and in the following colours: black - white - red - yellow - blue - brown - green and green/yellow and natural
- Standardization document7 pagesEnglish languagesale 10% offe-Library read for1 day
These methods are applicable to amorphous materials or to partially crystalline materials containing amorphous regions which are stable and do not undergo decomposition or sublimation in the glass transition region.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
Contains requirements for 3 types of pressure-sensitive adhesive tapes made with glass fabric. Products having thermal indices from 130 to 180 with rubber thermosetting adhesive, acrylic crosslinked and high temperature silicone adhesives.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day