Standard Practice for Carbon Black<span class='unicode'>&#x2014;</span>Sampling Packaged Shipments

SIGNIFICANCE AND USE
This practice is for use in obtaining representative samples of carbon black from the packages in the shipment. These samples are used to determine the average quality or variability of the shipment.
SCOPE
1.1 This practice covers the sampling of packaged carbon blacks for shipment in bags, cartons, flexible immediate bulk containers (FIBC), or other non-bulk packages.
Note 1—The tests to be made on the samples obtained by this practice shall be determined by the producer and the consumer. The specific details of each test method are described in appropriate ASTM methods used for testing carbon black.  
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Aug-2008
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D1799-03a(2008) - Standard Practice for Carbon Black<span class='unicode'>&#x2014;</span>Sampling Packaged Shipments
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D1799-03a(2008) - Standard Practice for Carbon Black<span class='unicode'>&#x2014;</span>Sampling Packaged Shipments
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D1799 − 03a(Reapproved 2008)
Standard Practice for
Carbon Black—Sampling Packaged Shipments
This standard is issued under the fixed designation D1799; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 4.3 Scoop, sample.
1.1 This practice covers the sampling of packaged carbon
5. General
blacks for shipment in bags, cartons, flexible intermediate bulk
containers (FIBC), or other non-bulk packages.
5.1 Packaged shipments of carbon blacks most often consist
of 11.35-kg (25-lb), 22.7-kg (50-lb), 25-kg (55-lb), or 50-kg
NOTE 1—The tests to be made on the samples obtained by this practice
shall be determined by the producer and the consumer.The specific details
(110-lb) bags. Flexible intermediate bulk containers usually
of each test method are described in appropriateASTM methods used for
range in size from 180 kg (396 lb) to 1300 kg (2860 lb). This
testing carbon black.
practice may be applied to bags or FIBCs of other sizes. These
1.2 The values stated in SI units are to be regarded as the
packages are loaded into vans in definite patterns agreed upon
standard. The values in parentheses are for information only.
by the producer and the consumer.These may be in the form of
unit loads, stacks, or individual FIBCs. In each case, a
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the shipment involves a given number of packages, units, tiers, or
mass.
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5.2 Samples are taken to evaluate conformance to specified
bility of regulatory limitations prior to use.
requirements. Multiple samples may be taken to evaluate
conformance or uniformity, or both, of a lot. The number of
2. Referenced Documents
samples, their location within the lot, and the quantity of the
2.1 ASTM Standards:
samples is determined by the purpose for taking the samples.A
D1509 Test Methods for Carbon Black—Heating Loss
lot shall be sampled as prescribed at the point of manufacture
D5817 Practice for Carbon Black, Pelleted—Reduction,
oratthereceivingpointasagreeduponbytheproducerandthe
Blending, and Drying of Gross Samples for Testing
consumer. Samples may be taken from the packages as loaded
or as received. Each sample taken shall represent a unit, lot, or
3. Significance and Use
approximately equal mass of material. Generally, it is desirable
3.1 This practice is for use in obtaining representative
to take one sample to represent each 5000 kg (11 000 lb)
samples of carbon black from the packages in the shipment.
increment of the lot. For smaller lot sizes being sampled for
These samples are used to determine the average quality or
uniformity, three samples representing approximately equal
variability of the shipment.
masses are recommended. If the uniformity of the lot is suspect
or unknown, more samples may be required. For lots with
4. Apparatus
known acceptable uniformity, one sample may be sufficient.
4.1 Sample Splitter, riffle-type (see Practice D5817 for
5.3 The size of the individual sample taken shall be deter-
equipment information).
mined by the purpose for taking the sample; the quantity
4.2 Sample Containers, airtight, 4 dm (1-gal) capacity.
needed to perform the expected test(s) with enough to repeat a
test, if needed; whether the sample will be tested individually
This practice is under the jurisdiction of ASTM Committee D24 on Carbon or in a composite; and the quantity needed for blending. For all
Black and is the direct responsibility of Subcommittee D24.61 on Carbon Black
samples except those taken directly from a bag, a minimum of
Sampling and Statistical Analysis.
3 3
4dm (1 gal) is recommended. The 4 dm (1 gal) minimum
Current edition approved Sept. 1, 2008. Published October 2008. Originally
sample size is recommended because pelleted carbon blacks
approved in 1960. Last previous edition approved in 2003 as D1799 – 03a. DOI:
10.1520/D1799-03AR08.
tend to stratify. When sampling directly from an individual
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
bag, the mass removed must be small enough that it does not
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
adversely affect the final mass remaining in the bag to render
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. it unsuitable for use.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D1799 − 03a (2008)
NOTE 2—Pellet quality tests may be erroneous due to a local or spotty
7.2.1 Method A—Using a scoop, remove the sample for
condition unless the samples are blended through the sample splitter as
testing from a representative portion of the bag after carefully
described in Practice D5817.
removing at least a 25–mm (1–in.) thickness of surface
material, or more if needed, to reach the
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D1799–03 Designation:D1799–03a (Reapproved 2008)
Standard Practice for
Carbon Black—Sampling Packaged Shipments
This standard is issued under the fixed designation D 1799; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 This practice covers the sampling of packaged carbon blacks for shipment in bags, cartons, flexible immediate bulk
containers (FIBC), or other non-bulk packages.
NOTE 1—The tests to be made on the samples obtained by this practice shall be determined by the producer and the consumer. The specific details of
each test method are described in appropriate ASTM methods used for testing carbon black.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D 1509Test Method for Carbon Black-Heating Loss Test Methods for Carbon BlackHeating Loss
D 5817 Practice for Carbon Black, Pelleted–Reduction, Blending, and Drying of Gross Samples for Testing
3. Significance and Use
3.1 This practice is for use in obtaining representative samples of carbon black from the packages in the shipment. These
samples are used to determine the average quality or variability of the shipment.
4. Apparatus
4.1 Sample Splitter, riffle-type (see Practice D 5817 for equipment information).
4.2 Sample Containers, airtight, 4 dm (1-gal) capacity.
4.3 Scoop, sample.
5. General
5.1 Packaged shipments of carbon blacks most often consist of 11.35–kg (25–lb),11.35-kg (25-lb), 22.7-kg (50-lb), 25–kg
(55–lb),25-kg (55-lb), or 50–kg (110–lb)50-kg (110-lb) bags. Flexible intermediate bulk containers usually range in size from
455180 kg (1000(396 lb) to 9101300 kg (2000 lb) up to 1250 kg (2750(2860 lb). This practice may be applied to bags or FIBCs
of other sizes. These packages are loaded into vans in definite patterns agreed upon by the producer and the consumer. These may
be in the form of unit loads, stacks, or individual FIBCs. In each case, a shipment involves a given number of packages, units,
tiers, or mass.
5.2 Samples are taken to evaluate conformance to specified requirements. Multiple samples may be taken to evaluate
conformance or uniformity, or both, of a lot. The number of samples, their location within the lot, and the quantity of the samples
is determined by the purpose for taking the samples. A lot shall be sampled as prescribed at the point of manufacture or at the
receiving point as agreed upon by the producer and the consumer. Samples may be taken from the packages as loaded or as
received. Each sample taken shall represent a unit, lot, or approximately equal mass of material. Generally, it is desirable to take
one sample to represent each 5000 kg (11 000 lb) increment of the lot. For smaller lot sizes being sampled for uniformity, three
samples representing approximately equal masses are recommended. If the uniformity of the lot is suspect or unknown, more
This practice is under the jurisdiction of ASTM Committee D24 on Carbon Black and is the direct responsibility of Subcommittee D24.61 on Carbon Black Sampling
and Statistical Analysis.
Current edition approved June 10, 2003. Published June 2003. Originally approved in 1960. Last previous edition approved in 2002 as D1799–02.
Current edition approved Sept. 1, 2008. Published October 2008. Originally approved in 1960. Last previous edition approved in 2003 as D 1799 – 03a.
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book ofASTM Standards
, Vol 09.01.volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
D1799–03a (2008)
samples may be required. For lots with known acceptable uniformity, one sample may be sufficient.
5.3 The size of the individual sample taken shall be determined by the purpose for taking the sample; the quantity needed to
perform the expected test(s) with enough to repeat a test, if needed; whether the sample will be tested individually or in a
composite; and the quantity needed for blending. For all samples except those taken directly from a bag, a minimum of 4 dm (1
gal) is recommended. The 4 dm (1 gal) minimum sample size is recommended because pelleted carbon blacks tend to stratify.
When sampling directly from an individual bag, the mass removed must be small enough that it does not adversely affect the final
mass remaining in the bag to render it unsuitable for use.
NOTE 2—Pelletqua
...

Questions, Comments and Discussion