Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)

SIGNIFICANCE AND USE
This test method provides a means of determining the compressive strength of hydraulic cement and other mortars and results may be used to determine compliance with specifications. Further, this test method is referenced by numerous other specifications and test methods. Caution must be exercised in using the results of this test method to predict the strength of concretes.
SCOPE
1.1 This test method covers determination of the compressive strength of hydraulic cement mortars, using 2-in. or [50-mm] cube specimens.
Note 1—Test Method C349 provides an alternative procedure for this determination (not to be used for acceptance tests).  
1.2 This test method covers the application of the test using either inch-pound or SI units. The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in Standard , of measurements made in other units.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. )

General Information

Status
Historical
Publication Date
30-Nov-2011
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C109/C109M-11b - Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C109/C109M-11b - Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C109/C109M − 11b
StandardTest Method for
Compressive Strength of Hydraulic Cement Mortars (Using
1
2-in. or [50-mm] Cube Specimens)
This standard is issued under the fixed designation C109/C109M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C114Test Methods for Chemical Analysis of Hydraulic
Cement
1.1 This test method covers determination of the compres-
C150Specification for Portland Cement
sive strength of hydraulic cement mortars, using 2-in. or
C230/C230MSpecification for Flow Table for Use in Tests
[50-mm] cube specimens.
of Hydraulic Cement
NOTE 1—Test Method C349 provides an alternative procedure for this
C305Practice for Mechanical Mixing of Hydraulic Cement
determination (not to be used for acceptance tests).
Pastes and Mortars of Plastic Consistency
1.2 This test method covers the application of the test using
C349Test Method for Compressive Strength of Hydraulic-
either inch-pound or SI units. The values stated in either SI
Cement Mortars (Using Portions of Prisms Broken in
units or inch-pound units are to be regarded separately as
Flexure)
standard. Within the text, the SI units are shown in brackets.
C511Specification for Mixing Rooms, Moist Cabinets,
Thevaluesstatedineachsystemmaynotbeexactequivalents;
Moist Rooms, and Water Storage Tanks Used in the
therefore,eachsystemshallbeusedindependentlyoftheother.
Testing of Hydraulic Cements and Concretes
Combiningvaluesfromthetwosystemsmayresultinnoncon-
C595Specification for Blended Hydraulic Cements
formance with the standard.
C618Specification for Coal Fly Ash and Raw or Calcined
Natural Pozzolan for Use in Concrete
1.3 Values in SI units shall be obtained by measurement in
C670Practice for Preparing Precision and Bias Statements
SI units or by appropriate conversion, using the Rules for
for Test Methods for Construction Materials
Conversion and Rounding given in Standard IEEE/ASTM
C778Specification for Sand
SI-10, of measurements made in other units.
C989SpecificationforSlagCementforUseinConcreteand
1.4 This standard does not purport to address all of the
Mortars
safety concerns, if any, associated with its use. It is the
C1005Specification for Reference Masses and Devices for
responsibility of the user of this standard to establish appro-
Determining Mass and Volume for Use in the Physical
priate safety and health practices and determine the applica-
Testing of Hydraulic Cements
bility of regulatory limitations prior to use. (Warning—Fresh
C1157Performance Specification for Hydraulic Cement
hydraulic cementitious mixtures are caustic and may cause
2 C1328Specification for Plastic (Stucco) Cement
chemical burns to skin and tissue upon prolonged exposure. )
C1329Specification for Mortar Cement
C1437Test Method for Flow of Hydraulic Cement Mortar
2. Referenced Documents
E4Practices for Force Verification of Testing Machines
3
2.1 ASTM Standards:
IEEE/ASTM SI-10Standard for Use of the International
C91Specification for Masonry Cement
System of Units (SI): The Modern Metric System
3. Summary of Test Method
1
ThistestmethodisunderthejurisdictionofASTMCommitteeC01onCement
and is the direct responsibility of Subcommittee C01.27 on Strength.
3.1 Themortarusedconsistsof1partcementand2.75parts
Current edition approved Dec. 1, 2011. Published March 2012. Originally
of sand proportioned by mass. Portland or air-entraining
approved in 1934. Last previous edition approved in 2011 as C109/C109M–11a.
portland cements are mixed at specified water/cement ratios.
DOI: 10.1520/C0109_C0109M-11B.
2
Water content for other cements is that sufficient to obtain a
See the section on Safety, Manual of Cement Testing, Annual Book of ASTM
Standards, Vol 04.01.
flow of 110 6 5 in 25 drops of the flow table. Two-inch or
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
[50-mm] test cubes are compacted by tamping in two layers.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
The cubes are cured one day in the molds and stripped and
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. immersed in lime water until tested.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C109/C109M − 11b
4. Significance and Use sorptive by immersion for 15 min in paraffin at approximately
1
392 °F or [200 °C], shall h
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C109/C109M–11a Designation: C109/C109M – 11b
Standard Test Method for
Compressive Strength of Hydraulic Cement Mortars (Using
1
2-in. or [50-mm] Cube Specimens)
This standard is issued under the fixed designation C109/C109M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 Thistestmethodcoversdeterminationofthecompressivestrengthofhydrauliccementmortars,using2-in.or[50-mm]cube
specimens.
NOTE 1—Test Method C349 provides an alternative procedure for this determination (not to be used for acceptance tests).
1.2 This test method covers the application of the test using either inch-pound or SI units. The values stated in either SI units
orinch-poundunitsaretoberegardedseparatelyasstandard.Withinthetext,theSIunitsareshowninbrackets.Thevaluesstated
in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values
from the two systems may result in nonconformance with the standard.
1.3 ValuesinSIunitsshallbeobtainedbymeasurementinSIunitsorbyappropriateconversion,usingtheRulesforConversion
and Rounding given in Standard IEEE/ASTM SI-10, of measurements made in other units.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and
2
tissue upon prolonged exposure. )
2. Referenced Documents
3
2.1 ASTM Standards:
C91 Specification for Masonry Cement
C114 Test Methods for Chemical Analysis of Hydraulic Cement
C150 Specification for Portland Cement
C230/C230M Specification for Flow Table for Use in Tests of Hydraulic Cement
C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
C349 Test Method for Compressive Strength of Hydraulic-Cement Mortars (Using Portions of Prisms Broken in Flexure)
C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of
Hydraulic Cements and Concretes
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C778 Specification for Sand
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing of
Hydraulic Cements
C1157 Performance Specification for Hydraulic Cement
C1328 Specification for Plastic (Stucco) Cement
C1329 Specification for Mortar Cement
C1437 Test Method for Flow of Hydraulic Cement Mortar
1
This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.27 on Strength .
Current edition approved Oct.Dec. 1, 2011. Published November 2011.March 2012. Originally approved in 1934. Last previous edition approved in 2011 as
C109/C109M–11a. DOI: 10.1520/C0109_C0109M-11AB.
2
See the section on Safety, Manual of Cement Testing, Annual Book of ASTM Standards, Vol 04.01.
3
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C109/C109M – 11b
E4 Practices for Force Verification of Testing Machines
IEEE/ASTM SI-10 Standard for Use of the International System of Units (SI): The Modern Metric System
3. Summary of Test Method
3.1 The mortar used consists of 1 part cement and 2.75 parts of sand proportioned by mass. Portland or air-entraining portland
cements are mixed at specified water/cement ratios. Water content for other cements is that sufficient to obtain a flow o
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.