Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry

SIGNIFICANCE AND USE
This procedure is suitable for manufacturing control and for verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to assure product quality. The analytical performance data included may be used as a benchmark to determine if similar X-ray spectrometers provide equivalent precision and accuracy, or if the performance of a particular spectrometer has changed.SCOPE
1.1 This test method covers the analysis of Ni-base alloys by wavelength dispersive X-ray Fluorescence Spectrometry for the determination of the following elements:

General Information

Status
Historical
Publication Date
30-Apr-2011
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E2465-11e1 - Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation: E2465 − 11
StandardTest Method for
Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray
1
Fluorescence Spectrometry
This standard is issued under the fixed designation E2465; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Editorial corrections were made in August 2011.
1. Scope E305 Practice for Establishing and Controlling Atomic
Emission Spectrochemical Analytical Curves
1.1 This test method covers the analysis of Ni-base alloys
E1361 Guide for Correction of Interelement Effects in
bywavelengthdispersiveX-rayFluorescenceSpectrometryfor
X-Ray Spectrometric Analysis
the determination of the following elements:
E1601 Practice for Conducting an Interlaboratory Study to
Element Concentration Range %
Evaluate the Performance of an Analytical Method
Manganese 0.17 to 1.6
Phosphorus 0.005 to 0.015 E1622 Practice for Correction of Spectral Line Overlap in
Silicon 0.02 to 0.6
Wavelength-Dispersive X-Ray Spectrometry (Withdrawn
Chromium 11 to 22
3
2006)
Nickel 31 to 77
Aluminum 0.12 to 1.3
2.2 Other Documents:
Molybdenum 0.045 to 10
ISO 17025 General requirements for the competence of
Copper 0.014 to 2.5
testing and calibration laboratories
Titanium 0.20 to 3.0
4
Niobium 1.43 to 5.3
2.3 U.S. Government Standards:
Iron 2 to 46
10 CFR Part 19 Notices, Instructions and Reports to Work-
Tungsten 0.016 to 0.50
ers: Inspection and Investigations
Cobalt 0.014 to 0.35
10 CFR Part 20 Standards for Protection Against Radiation
NOTE 1—Unless exceptions are noted, concentration ranges can be
extended by the use of suitable reference materials. Once these element
3. Terminology
ranges are extended they must be verified by some experimental means.
This could include but not limited to Gage Repeatability and Reproduc-
3.1 For definitions of terms used in this test method, refer to
ibility studies and/or Inter-laboratory Round Robin studies. Once these
Terminology .
studies are completed, they will satisfy the ISO 17025 requirements for
capability.
4. Summary of Test Method
1.2 This standard does not purport to address all of the
4.1 Thetestspecimenisfinishedtoaclean,uniformsurface,
safety concerns, if any, associated with its use. It is the
then irradiated with an X-ray beam of high energy. The
responsibility of the user of this standard to establish appro-
secondary X-rays produced are dispersed by means of crystals
priate safety and health practices and to determine the
and the intensities are measured by suitable detectors at
applicability of regulatory limitations prior to use.
selected wavelengths. The outputs of the detectors in voltage
pulsesarecounted.Radiationmeasurementsaremadebasedon
2. Referenced Documents
the time required to reach a fixed number of counts, or on the
2
2.1 ASTM Standards:
total counts obtained for a fixed time (generally expressed in
E135 Terminology Relating to Analytical Chemistry for
counts or kilocounts per unit time).
Metals, Ores, and Related Materials
4.2 Concentrations of the elements are determined by relat-
ing the measured radiation of unknown specimens to analytical
1
This test method is under the jurisdiction of ASTM Committee E01 on
curves prepared with suitable reference materials. Either a
Analytical Chemistry for Metals, Ores, and Related Materials and is the direct
fixed-channel (simultaneous) spectrometer or a sequential
responsibility of Subcommittee E01.08 on Ni and Co and HighTemperatureAlloys.
Current edition approved May 1, 2011. Published June 2011. Originally
approved in 2006. Last previous edition approved in 2006 as E2465 – 06. DOI:
3
10.1520/E2465-11. The last approved version of this historical standard is referenced on
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or www.astm.org.
4
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from the Nuclear Regulatory Commission, Public Document Room,
Standards volume information, refer to the standard’s Document Summary page on Mail Stop:OWFN-1 F13, Washington, DC 20555, (800) 397-4209, or via email at
the ASTM website. PDR.Resource@nrc.gov, or via the website at www.nrc.gov.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
E2465 − 11
spectrometer, or an instrument combining both fixed-channels maticpumpdownoftheopticalpath,andmaintainacontrolled
and one or more goniometers shall be used. pressure, usually 13Pa (100 mm Hg) or less, controlled to 63
Pa (20 mm Hg).Ahelium-flushed system is an alternative to a
5.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.