Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile

SCOPE
1.1 This specification establishes the criteria for acceptance, prior to installation, of drain tile and perforated drain tile to be used for underdrainage, filter fields, leaching fields, and similar subdrainage installations.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat pertains only to the Test Methods portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.  
Note 1—Attention is called to Test Methods C 301 and Terminology C 896.

General Information

Status
Historical
Publication Date
30-Sep-2009
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C4-04(2009) - Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C4-04(2009) - Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C4 −04(Reapproved 2009)
Standard Specification for
1
Clay Drain Tile and Perforated Clay Drain Tile
This standard is issued under the fixed designation C4; the number immediately following the designation indicates the year of original
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 4. Classification
4.1 Four classes of clay drain tile are specified:
1.1 Thisspecificationestablishesthecriteriaforacceptance,
prior to installation, of drain tile and perforated drain tile to be 4.1.1 Standard.
usedforunderdrainage,filterfields,leachingfields,andsimilar 4.1.2 Extra Quality.
subdrainage installations.
4.1.3 Heavy Duty.
4.1.4 Extra Strength.
1.2 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
4.2 Drain tile of a higher strength classification than that
conversions to SI units that are provided for information only
specified by the purchaser may be furnished by the seller,
and are not considered standard.
provided the substituted drain tile meets the physical require-
ments of the class specified.
1.3 The following safety hazards caveat pertains only to the
Test Methods portion of this specification: This standard does
5. Materials and Manufacture
not purport to address all of the safety concerns, if any,
associated with its use. It is the responsibility of the user of this
5.1 Drain tile shall be manufactured from clay, fire clay,
standard to establish appropriate safety and health practices
shale, surface clay, or a combination of these materials, that,
and determine the applicability of regulatory limitations prior
when formed into tile and fired to suitable temperatures, yields
to use.
a product that conforms to this specification.
NOTE 1—Attention is called to Test Methods C301 and Terminology
C896. 6. Physical Properties
6.1 Drain tile shall meet the physical test requirements for
2. Referenced Documents
the class, as specified in Table 1.
2
2.1 ASTM Standards:
6.2 Themaximumwaterabsorption(5-hboiling)shallbeas
C301Test Methods for Vitrified Clay Pipe
follows:
C896Terminology Relating to Clay Products
Average, % Individual, %
Standard 13 16
Extra Quality 11 13
3. Terminology
Heavy Duty 11 13
3.1 Definitions:
Extra Strength 11 13
3.1.1 Clay, fire clay, shale, and surface clay are as defined
6.3 The requirements for water absorption (5–h boiling)
in Terminology C896.
shallbewaived,providedthattestspecimensmeettherequire-
3.1.2 Within this specification, the terms tile, drain tile, and
ments of the freezing and thawing test, Section 13, of this
clay drain tile are synonyms.
specification
7. Sizes and Perforations
1
This specification is under the jurisdiction of ASTM Committee C04 on
7.1 The size of drain tile shall be designated by inside
Vitrified Clay Pipe and is the direct responsibility of Subcommittee C04.20 on
diameter. Not all sizes and strengths may be available from all
Methods of Test and Specifications.
manufacturers.
Current edition approved Oct. 1, 2009. Published October 2009. Originally
´1
approved in 1914. Last previous edition approved in 2004 as C4–04 . DOI:
7.2 The minimum length of drain tile smaller than 10 in.
10.1520/C0004-04R09.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or (255 mm) diameter shall be approximately 12 in. (305 mm).
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
7.3 The length of drain tile 10 in. (255 mm) through 30 in.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. (760mm)diametershallbenotlessthan1timestheirdiameter.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C4−04 (2009)
TABLE 1 Physical Test Requirements for Clay Drain Tile
Standard Extra Quality Heavy Duty Extra Strength
Internal
A A A A
Diameter Minimum Crushing Strength, Minimum Crushing Strength, Minimum Crushing Strength, Minimum Crushing Strength,
lbf/linear ft (kN/m) lbf/linear ft (kN/m) lbf/linear ft (kN/m) lbf/linear ft (kN/m)
of Tile,
in.
Average Individual Average Individual Average Individual Average Individual
1
3 ⁄2 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
4 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
5 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
6 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
8 800 (12) 680 (10) 1100 (16) 990 (14) 1500 (22) 1350 (20) 2140 (31) 1920 (28)
10 800 (12)
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C4–03 Designation:C4–04 (Reapproved 2009)
Standard Specification for
1
Clay Drain Tile and Perforated Clay Drain Tile
ThisstandardisissuedunderthefixeddesignationC4;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope
1.1 Thisspecificationestablishesthecriteriaforacceptance,priortoinstallation,ofdraintileandperforateddraintiletobeused
for underdrainage, filter fields, leaching fields, and similar subdrainage installations.
1.2The values stated in inch-pound units are to be regarded as the standard.The values given in parentheses are for information
only.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat pertains only to the Test Methods portion of this specification: This standard does not
purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
NOTE 1—Attention is called to Test Methods C301 and Terminology C896.
2. Referenced Documents
2
2.1 ASTM Standards:
C301 Test Methods for Vitrified Clay Pipe
C896 Terminology Relating to Clay Products
3. Terminology
3.1 Definitions:
3.1.1 Clay, fire clay, shale, and surface clay are as defined in Terminology C896.
3.1.2 Within this specification, the terms tile, drain tile, and clay drain tile are synonyms.
4. Classification
4.1 Four classes of clay drain tile are specified:
4.1.1 Standard.
4.1.2 Extra Quality.
4.1.3 Heavy Duty.
4.1.4 Extra Strength.
4.2 Drain tile of a higher strength classification than that specified by the purchaser may be furnished by the seller, provided
the substituted drain tile meets the physical requirements of the class specified.
5. Materials and Manufacture
5.1 Drain tile shall be manufactured from clay, fire clay, shale, surface clay, or a combination of these materials, that, when
formed into tile and fired to suitable temperatures, yields a product that conforms to this specification.
6. Physical Properties
6.1 Drain tile shall meet the physical test requirements for the class, as specified in Table 1.
6.2 The maximum water absorption (5-h boiling) shall be as follows:
1
This specification is under the jurisdiction ofASTM Committee C04 on Vitrified Clay Pipe and is the direct responsibility of Subcommittee C04.20 on Methods of Test
and Specifications.
Current edition approved February 10, 2003. Published June 2003. Originally approved in 1914. Last previous edition approved in 2002 as C4–02.
´1
Current edition approved Oct. 1, 2009. Published October 2009. Originally approved in 1914. Last previous edition approved in 2004 asC4–04 .
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
, Vol 04.05.volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C4–04 (2009)
TABLE 1 Physical Test Requirements for Clay Drain Tile
Standard Extra Quality Heavy Duty Extra Strength
Internal
A A A A
Diameter Minimum Crushing Strength, Minimum Crushing Strength, Minimum Crushing Strength, Minimum Crushing Strength,
of Tile, lbf/linear ft (kN/m) lbf/linear ft (kN/m) lbf/linear ft (kN/m) lbf/linear ft (kN/m)
in.
Average Individual Average Individual Average Individual Average Individual
1
3 ⁄2 800 (11.7) 680 (9.9) 1100 (16.0) 990 (14.5) 1400 (20.4) 1260 (18.4) 2000 (29.2) 1800 (26.3)
1
3 ⁄2 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
4 800 (11.7) 680 (9.9) 1100 (16.0) 990 (14.5) 1400 (20.4) 1260 (18.4) 2000 (29.2) 1800 (26.3)
4 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
5 800 (11.7) 680 (9.9) 1100 (16.0) 990 (14.5) 1400 (20.4) 1260 (18.4) 2000 (29.2) 1800 (26.3)
5 800 (12) 680 (10) 1100 (16) 990 (14) 1400 (20) 1260 (18) 2000 (29) 1800 (26)
6 800 (11.7) 680 (9.9) 1100 (16
...

Questions, Comments and Discussion