Standard Specification for Concrete Pipe for Irrigation or Drainage

ABSTRACT
This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients and for use in drainage. The concrete shall consist of cementitious materials, minerals, aggregates, and water. Cement shall conform to the requirements for Portland cement or shall be Portland blast-furnace slag cement, or slag modified Portland cement, or Portland-pozzolan cement conforming to the requirements except that the pozzolan constituent in the Type IP Portland-pozzolan cement shall be fly ash. The combination of cementitious materials used in the concrete shall be one of the following: Portland cement only, Portland blast furnace slag cement only, slag modified portland cement only, portland pozzolan cement only, a combination of Portland cement and fly ash, a combination of portland cement and ground-granulated blast-furnace slag or a combination of fly ash and ground granulated blast furnace slag. The specimens shall undergo external load test, absorption test and hydrostatic test. The material shall also conform to the required internal diameter and wall thickness.
SCOPE
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.
1.2 A complete SI companion to Specification C 118 has been developed—C 118M; therefore, no SI equivalents are presented in this specification.
Note 1R`12;This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

General Information

Status
Historical
Publication Date
30-Nov-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C118-05a - Standard Specification for Concrete Pipe for Irrigation or Drainage
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C118 – 05a
Standard Specification for
1
Concrete Pipe for Irrigation or Drainage
This standard is issued under the fixed designation C118; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
TABLE 1 Standard Dimensions, Working Pressure, and Test
1. Scope
A
Requirements for Standard Concrete Irrigation Pipe
1.1 This specification covers nonreinforced concrete pipe to
Minimum Minimum
be used for the conveyance of irrigation water with working
Internal Thickness Working Internal Three-Edge-Bearing
B
pressures, including hydraulic transients, as shown in Table 1
Designated of Wall, Pressure, Hydrostatic Load, lbf/linear ft
Diameter, in. T,in. ft Test Pressure,
and for use in drainage.
psi
1.2 A complete SI companion to Specification C118 has
7
6 ⁄8 30 50 1300
been developed—C118M; therefore, no SI equivalents are
8 1 30 50 1350
presented in this specification. 1
10 1 ⁄8 30 50 1400
1
12 1 ⁄4 25 45 1500
NOTE 1—This specification is for manufacturing and purchase only and 3
14 1 ⁄8 25 45 1600
1
does not include requirements for bedding, backfill, installation, or field
15 1 ⁄2 25 45 1650
1
16 1 ⁄2 25 45 1700
repairs.Theowneriscautionedthathemustcorrelatefieldconditionswith
3
18 1 ⁄4 25 45 1800
the characteristics of the pipe specified and provide inspection during
20 2 25 40 1850
installation.
1
21 2 ⁄8 25 40 1900
1
24 2 ⁄4 25 40 2000
2. Referenced Documents
A
For hydrostatic test requirements, refer to 10.5.
2
B
2.1 ASTM Standards:
Higher working pressures are not prohibited up to a maximum of 40 ft for 6
through 8-in. diameters, 35 ft for 10 through 12-in. diameters, and 30 ft. for 14-in.
C33 Specification for Concrete Aggregates
through 24-in. diameters. In these cases, the strength of the pipe shall be
C150 Specification for Portland Cement
increased to give a minimum of at least four times the design working pressure
C497 TestMethodsforConcretePipe,ManholeSections,or
when tested as specified in 10.5.
Tile
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined
4. Classification
Natural Pozzolan for Use in Concrete
4.1 Pipe manufactured according to this specification shall
C822 Terminology Relating to Concrete Pipe and Related
be known as “ASTM Standard Concrete Irrigation Pipe,”
Products
“ASTM Standard Concrete Drainage Pipe,” or “ASTM Heavy-
C989 Specification for Slag Cement for Use in Concrete
Duty Concrete Drainage Pipe.”
and Mortars
C1116/C1116M Specification for Fiber-Reinforced Con-
5. Basis of Acceptance
crete
5.1 The acceptability of the pipe shall be determined by the
results of the tests prescribed in this specification, if and when
3. Terminology
required and by inspection to determine whether the pipe
3.1 Definitions—For definitions of terms relating to con-
conforms to this specification as to design and freedom from
crete pipe, see Terminology C822.
defects.
1 6. Materials
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
6.1 Concrete—The concrete shall consist of cementitious
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
materials, mineral, aggregates, and water.
Current edition approved Dec. 1, 2005. Published January 2006. Originally
6.2 Cementitious Materials:
approved in 1935. Last previous edition approved in 2005 as C118 – 05. DOI:
10.1520/C0118-05A. 6.2.1 Cement—Cement shall conform to the requirements
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
for portland cement of Specification C150 or shall be portland
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
blast-furnace slag cement, or slag modified portland cement, or
Standards volume information, refer to the standard’s Document Summary page on
portland-pozzolan cement conforming to the requirements of
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C118 – 05a
Specification C595, except that the pozzolan constituent in the 7.2 Modified Design—Manufacturers shall submit to the
Type IP portland-pozzolan cement shall be fly ash. owner for approval prior to manufacture, wall thicknesses
6.2.2 Fly Ash—Fly ash shall conform to the requirements of other than those shown in Table 1 or Table 2. Such pipe shall
Specification C618, Class F or Class C. meet all of the test and performance requirements specified by
6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)— the owner in accordance with Section 10.
G
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.