SIGNIFICANCE AND USE
The estimate of oxidation stability is useful in controlling the continuity of this property for batch acceptance of production lots having the same operation. It is not intended that this test method be a substitute for Test Method D 943 or be used to compare the service lives of new oils of different compositions.
This test method is also used to assess the remaining oxidation test life of in-service oils.
SCOPE
1.1 This test method utilizes an oxygen-pressured vessel to evaluate the oxidation stability of new and in-service turbine oils having the same composition (base stock and additives) in the presence of water and a copper catalyst coil at 150°C.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.2.1 Exception—Other units are provided in parentheses (psi, grams, and inches), because they are either the industry accepted standard or the apparatus is built according the figures in this standard, or both.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.2, 6.4, 6.5, 6.6, and 6.10.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D2272 – 09
Standard Test Method for
Oxidation Stability of Steam Turbine Oils by Rotating
1
Pressure Vessel
This standard is issued under the fixed designation D2272; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* Automotive Engine Oils by Thin-Film Oxygen Uptake
2 (TFOUT)
1.1 This test method utilizes an oxygen-pressured vessel to
D6299 Practice for Applying Statistical Quality Assurance
evaluate the oxidation stability of new and in-service turbine
and Control Charting Techniques to Evaluate Analytical
oils having the same composition (base stock and additives) in
Measurement System Performance
the presence of water and a copper catalyst coil at 150°C.
4
2.2 Energy Institute Standard:
1.2 The values stated in SI units are to be regarded as
IP 229 Determination of the relative oxidation stability by
standard. No other units of measurement are included in this
rotating bomb of mineral turbine oil
standard.
1.2.1 Exception—Other units are provided in parentheses
3. Summary of Test Method
(psi, grams, and inches), because they are either the industry
3.1 The test oil, water, and copper catalyst coil, contained in
acceptedstandardortheapparatusisbuiltaccordingthefigures
a covered glass container, are placed in a vessel equipped with
in this standard, or both.
a pressure gauge.The vessel is charged with oxygen to a gauge
1.3 This standard does not purport to address all of the
pressure of 620 kPa (90 psi, 6.2 bar) (see Eq 1), placed in a
safety concerns, if any, associated with its use. It is the
constant-temperatureoilbathsetat150°Cordryblocktakento
responsibility of the user of this standard to establish appro-
150°C (Fig. 1 and Fig. 2), and rotated axially at 100 rpm at an
priate safety and health practices and determine the applica-
angle of 30° from the horizontal.
bility of regulatory limitations prior to use. For specific
3.2 The number of minutes required to reach a specific drop
warning statements, see 6.2, 6.4, 6.5, 6.6, and 6.10.
in gauge pressure is the oxidation stability of the test sample.
2. Referenced Documents
100 kPa 5 1.00 bar 5 14.5 psi (1)
3
2.1 ASTM Standards:
4. Significance and Use
B1 Specification for Hard-Drawn Copper Wire
D943 Test Method for Oxidation Characteristics of Inhib- 4.1 The estimate of oxidation stability is useful in control-
ited Mineral Oils ling the continuity of this property for batch acceptance of
D1193 Specification for Reagent Water production lots having the same operation. It is not intended
D4057 Practice for Manual Sampling of Petroleum and thatthistestmethodbeasubstituteforTestMethodD943orbe
Petroleum Products used to compare the service lives of new oils of different
D4742 Test Method for Oxidation Stability of Gasoline compositions.
4.2 This test method is also used to assess the remaining
oxidation test life of in-service oils.
1
This test method is under the jurisdiction of ASTM Committee D02 on
Method A
Petroleum Products and Lubricants and is the direct responsibility of Subcommittee
D02.09.0C on Oxidation of Turbine Oils.
5. Apparatus
Current edition approved June 15, 2009. Published September 2009. Originally
approved in 1964. Last previous edition approved in 2002 as D2272–02. DOI:
5.1 Method A, Liquid Bath RPVOT—Oxidation Vessel,
10.1520/D2272-09.
2
Glass Sample Container with Four-Hole PTFE Disk, Hold-
von Fuchs, G. H., Claridge, E. L., and Zuidema, H. H., “The Rotary Bomb
Oxidation Test for Inhibited Turbine Oils,” Materials Research and Standards,
Down Spring, Catalyst-Coil, Pressure Gauge, Thermometer,
MTRSA (formerly ASTM Bulletin), No. 186, December 1952, pp. 43-46; von
and Test Bath as described in Annex A1. The assembled
Fuchs, G. H., “Rotary Bomb Oxidation Test,” Lubrication Engineering, Vol 16,
apparatus is shown schematically in Fig. 1 and Fig. A1.6.
No. 1, January 1960, pp. 22-31.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
4
Standards volume information, refer to the standard’s Document Summary page on Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,
the ASTM website. U.K., http://www.energyinst.org.uk.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D2272 – 09
FIG. 1 Schematic Drawing of the Rotary Vessel Test
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D2272–02 Designation: D 2272 – 09
Standard Test Method for
Oxidation Stability of Steam Turbine Oils by Rotating
1
Pressure Vessel
This standard is issued under the fixed designation D 2272; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
2
1.1 This test method utilizes an oxygen-pressured vessel to evaluate the oxidation stability of new and in-service turbine oils
having the same composition (base stock and additives) in the presence of water and a copper catalyst coil at 150°C.
1.2The values stated in SI units are to be regarded as the standard.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.2.1 Exception—Other units are provided in parentheses (psi, grams, and inches), because they are either the industry accepted
standard or the apparatus is built according the figures in this standard, or both.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific warning statements, see 6.2, 6.4, 6.5, 6.6, 6.10, and 6.116.10.
2. Referenced Documents
3
2.1 ASTM Standards:
B1 Specification for Hard-Drawn Copper Wire
D235Specification for Mineral Spirits (Petroleum Spirits) (Hydrocarbon Dry Cleaning Solvent) Specification for Hard-Drawn
Copper Wire
D 943 Test Method for Oxidation Characteristics of Inhibited Mineral Oils
D 1193 Specification for Reagent Water
D2112Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel Specification for Reagent
Water
D 4057 Practice for Manual Sampling of Petroleum and Petroleum Products
8
D 4742 Test Method for Oxidation Stability of GasolineAutomotive Engine Oils byThin-Film Oxygen Uptake (TFOUT) Test
Method for Oxidation Stability of Gasoline Automotive Engine Oils by Thin-Film Oxygen Uptake (TFOUT)
D 6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical
Measurement System Performance
2.2 British Standard:
B22000Part 0: Section 0.1,
IP37C Thermometer
2.3 Institute of Petroleum Standard:
4
IP 229 Energy Institute Standard:
IP 229 Determination of the relative oxidation stability by rotating bomb of mineral turbine oil
1
This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products and Lubricants and is the direct responsibility of Subcommittee D02.09 on
Oxidation.
Current edition approved August 10, 2002. Published October 2002. Originally published as D2272-64 T. Last previous edition D2272-98.on Petroleum Products and
Lubricants and is the direct responsibility of Subcommittee D02.09.0C on Oxidation of Turbine Oils.
Current edition approved June 15, 2009. Published September 2009. Originally approved in 1964. Last previous edition approved in 2002 as D 2272–02.
2
von Fuchs, G. H., Claridge, E. L., and Zuidema, H. H., “The Rotary Bomb Oxidation Test for Inhibited Turbine Oils,” Materials Research and Standards, MTRSA
(formerlyASTM Bulletin), No. 186, December 1952, pp. 43-46; von Fuchs, G. H., “Rotary Bomb Oxidation Test,” Lubrication Engineering, Vol 16, No. 1, January 1960,
pp. 22-31.
3
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book ofASTM Standards
, Vol 02.03.volume information, refer to the standard’s Document Summary page on the ASTM website.
4
Annual Book of ASTM Standards, Vol 06.04.
4
Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR, U.K., http://www.energyinst.org.uk.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D2272–09
3. Summary of Test Method
3.1 The test oil, water, and copper catalyst coil, contained in a covered glass container, are placed in a vessel equipped with a
pressure gauge. The vessel is charged with oxygen to a gauge pressure of 620 kPa (90
...
Questions, Comments and Discussion