ASTM D3427-03
(Test Method)Standard Test Method for Air Release Properties of Petroleum Oils
Standard Test Method for Air Release Properties of Petroleum Oils
SCOPE
1.1 This test method covers the ability of turbine, hydraulic, and gear oils to separate entrained air.
Note 1—This test method was developed for mineral based oils. It may be used for some synthetic fluids; however, the precision statement applies only to petroleum oils.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation:D3427–03
Standard Test Method for
1
Air Release Properties of Petroleum Oils
This standard is issued under the fixed designation D3427; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope* flowisstopped,thetimerequiredfortheairentrainedintheoil
toreduceinvolumeto0.2%isrecordedastheairreleasetime.
1.1 Thistestmethodcoverstheabilityofturbine,hydraulic,
and gear oils to separate entrained air.
NOTE 2—By agreement between the customer and the laboratory, the
oil may be heated at other temperatures. However, the precision at these
NOTE 1—Thistestmethodwasdevelopedformineralbasedoils.Itmay
different temperatures is not known at present.
beusedforsomesyntheticfluids;however,theprecisionstatementapplies
only to petroleum oils.
5. Significance and Use
1.2 This standard does not purport to address all of the
5.1 Agitation of lubricating oil with air in equipment, such
safety concerns, if any, associated with its use. It is the
as bearings, couplings, gears, pumps, and oil return lines, may
responsibility of the user of this standard to establish appro-
produce a dispersion of finely divided air bubbles in the oil. If
priate safety and health practices and determine the applica-
the residence time in the reservoir is too short to allow the air
bility of regulatory limitations prior to use.
bubbles to rise to the oil surface, a mixture of air and oil will
circulate through the lubricating oil system. This may result in
2. Referenced Documents
aninabilitytomaintainoilpressure(particularlywithcentrifu-
2
2.1 ASTM Standards:
gal pumps), incomplete oil films in bearings and gears, and
D1193 Specification for Reagent Water
poor hydraulic system performance or failure.
D1401 Test Method for Water Separability of Petroleum
5.2 This test method measures the time for the entrained air
Oils and Synthetic Fluids
content to fall to the relatively low value of 0.2% volume
E1 Specification for ASTM Thermometers
under a standardized set of test conditions and hence permits
3
2.2 DIN Standard:
the comparison of the ability of oils to separate entrained air
DIN 51 381
under conditions where a separation time is available. The
significance of this test method has not been fully established.
3. Terminology
However, entrained air can cause sponginess and lack of
3.1 Definitions of Terms Specific to This Standard:
sensitivityofthecontrolofturbineandhydraulicsystems.This
3.1.1 air release time, n—thenumberofminutesneededfor
test may not be suitable for ranking oils in applications where
air entrained in the oil to reduce in volume to 0.2% under the
residence times are short and gas contents are high.
conditions of this test and at the specified temperature.
6. Apparatus
4. Summary of Test Method
6.1 AschematicdiagramoftheapparatusisshowninFig.1.
4.1 Compressed air is blown through the test oil, which has
The component parts are described as follows:
been heated to a temperature of 25, 50, or 75°C. After the air
6.1.1 TestVessel,madeofborosilicateglassasshowninFig.
2, consisting of a jacketed sample tube fitted with an air inlet
capillary,baffleplate,andairoutlettube.Thetwopartsofeach
1
test vessel should be marked and preferably used as a pair.
This test method is under the jurisdiction of ASTM Committee D02 on
PetroleumProductsandLubricantsandisthedirectresponsibilityofSubcommittee
Interchanged parts may be used so long as the resultant test
D02.C0 on Turbine Oils.
vessel conforms to the stated dimensions.
Current edition approved Nov. 1, 2003. Published December 2003. Originally
6.1.2 Pressure Gage, covering the range from 0 to 35 kPa,
approved in 1975. Last previous edition approved in 2002 as D3427–02.
2
withdivisionsatleastevery2kPa,andanaccuracyof1.5kPa.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.1.3 Thermometers:
Standards volume information, refer to the standard’s Document Summary page on
6.1.3.1 Air Thermometer, for measuring compressed air
the ASTM website.
3
temperature. ASTM Precision Thermometer having a range
Available from Beuth Verlag GmbH, Burggrafenstrasse 6, 1000 Berlin 30,
Germany. from−20 to 102°C, graduated in 0.2°C and conforming to the
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D3427–03
or slippage of the hose connections. Use of a pressure relief
valve set at 70 kPa (10 psi
...
Questions, Comments and Discussion