Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)

ABSTRACT
This specification covers the specification for the nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, and for use in drainage. The design, joint, and concrete mixture of the pipe is detailed. The acceptability of the pipe shall be determined by the results of the tests prescribed in this specification, such as external load test, absorption test, and hydrostatic test.
SCOPE
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.
1.2 This specification is the SI counterpart of Specification C 118.
Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

General Information

Status
Historical
Publication Date
30-Nov-2005
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C118M-05a - Standard Specification for Concrete Pipe for Irrigation or Drainage (Metric)
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C118M – 05a
Standard Specification for
1
Concrete Pipe for Irrigation or Drainage (Metric)
This standard is issued under the fixed designation C118M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
TABLE 1 Standard Dimensions, Working Pressure, and Test
1. Scope
A
Requirements for Standard Concrete Irrigation Pipe
1.1 This specification covers nonreinforced concrete pipe to
Minimum
Minimum
be used for the conveyance of irrigation water with working
Internal Thickness Working Internal
Three-Edge-
B
pressures, including hydraulic transients, as shown in Table 1
Designated of Wall, Pressure, Hydrostatic
Bearing Load,
Diameter, mm T,mm kPa Test Pressure,
and for use in drainage.
kN/linear m
kPa
1.2 This specification is the SI counterpart of Specification
150 22 90 345 19.0
C118.
200 25 90 345 19.5
250 29 90 345 20.5
NOTE 1—This specification is for manufacturing and purchase only and
300 32 75 310 22.0
does not include requirements for bedding, backfill, installation, or field
350 35 75 310 23.5
repairs.Theowneriscautionedthathemustcorrelatefieldconditionswith
375 38 75 310 24.0
the characteristics of the pipe specified and provide inspection during
400 38 75 310 25.0
installation. 450 44 75 310 26.5
500 50 75 275 27.0
525 54 75 275 27.5
2. Referenced Documents
600 57 75 275 29.0
2
2.1 ASTM Standards:
A
For hydrostatic test requirements, refer to 10.5.
B
C33 Specification for Concrete Aggregates
Higher working pressures are not prohibited up to a maximum of 120 kPa for
150 through 200-mm diameters, 105 kPa for 250 through 300-mm diameters, and
C150 Specification for Portland Cement
90kPafor350through600-mmdiameters.Inthesecases,thestrengthofthepipe
C497M Test Methods for Concrete Pipe, Manhole Sections,
shall be increased to give a minimum internal hydrostatic test pressure of at least
or Tile [Metric]
four times the design working pressure when tested as specified in 10.5.
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined
4. Classification
Natural Pozzolan for Use in Concrete
4.1 Pipe manufactured according to this specification shall
C822 Terminology Relating to Concrete Pipe and Related
be known as “ASTM Standard Concrete Irrigation Pipe,”
Products
“ASTM Standard Concrete Drainage Pipe,” or “ASTM Heavy-
C989 Specification for Slag Cement for Use in Concrete
Duty Concrete Drainage Pipe.”
and Mortars
C1116 Specification for Fiber-Reinforced Concrete and
5. Basis of Acceptance
Shotcrete
5.1 The acceptability of the pipe shall be determined by the
results of the tests prescribed in this specification, if and when
3. Terminology
required and by inspection to determine whether the pipe
3.1 Definitions—For definitions of terms relating to con-
conforms to this specification as to design and freedom from
crete pipe, see Terminology C822.
defects.
1 6. Materials
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.01 on
6.1 Concrete—The concrete shall consist of cementitious
Non-Reinforced Concrete Sewer, Drain and Irrigation Pipe.
materials, mineral aggregates, and water.
Current edition approved Dec. 1, 2005. Published January 2006. Originally
6.2 Cementitious Materials:
approved in 1980. Last previous edition approved in 2005 as C118M – 05. DOI:
10.1520/C0118M-05A.
6.2.1 Cement—Cement shall conform to the requirements
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
for portland cement of Specification C150 or shall be portland
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
blast-furnaceslagcement,orslag-modifiedportlandcement,or
Standards volume information, refer to the standard’s Document Summary page on
portland-pozzolan cement conforming to the requirements of
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C118M – 05a
Specification C595, except that the pozzolan constituent in the 7.2 Modified Design—Manufacturers shall submit to the
Type IP portland-pozzolan cement shall be fly ash. owner for approval prior to manufacture, wall thicknesses
6.2.2 Fly Ash—Fly ash shall conform to the requirements of other than those shown in Table 1 or Table 2. Such pipe shall
Specification C618, Class F or Class C. meet all of the test and performance requirements specified by
6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)— the owner in accordance with Section 10.
GGBFS shall conform to the requ
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.