ASTM C94/C94M-00e2
(Specification)Standard Specification for Ready-Mixed Concrete
Standard Specification for Ready-Mixed Concrete
SCOPE
1.1 This specification covers ready-mixed concrete manufactured and delivered to a purchaser in a freshly mixed and unhardened state as hereinafter specified. Requirements for quality of concrete shall be either as hereinafter specified or as specified by the purchaser. In any case where the requirements of the purchaser differ from these in this specification, the purchaser's specification shall govern. This specification does not cover the placement, consolidation, curing, or protection of the concrete after delivery to the purchaser.
1.2 The values stated in either SI units, shown in brackets, or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 As used throughout this specification the manufacturer shall be the contractor, subcontractor, supplier, or producer who furnishes the ready-mixed concrete. The purchaser shall be the owner or representative thereof.
1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
e2
Designation: C 94/C 94M – 00
Standard Specification for
1
Ready-Mixed Concrete
This standard is issued under the fixed designation C 94/C 94M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
e NOTE—Editorial corrections were made throughout in January 2001.
2
e NOTE—Editorial correction to 13.1.1 was applied July 2001.
1. Scope Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube
3
Specimens)
1.1 This specification covers ready-mixed concrete manu-
C 138 Test Method for Unit Weight, Yield, and Air Content
factured and delivered to a purchaser in a freshly mixed and
2
(Gravimetric) of Concrete
unhardened state as hereinafter specified. Requirements for
C 143/C 143M Test Method for Slump of Hydraulic Ce-
quality of concrete shall be either as hereinafter specified or as
2
ment Concrete
specified by the purchaser. In any case where the requirements
3
C 150 Specification for Portland Cement
of the purchaser differ from these in this specification, the
2
C 172 Practice for Sampling Freshly Mixed Concrete
purchaser’s specification shall govern. This specification does
C 173 Test Method for Air Content of Freshly Mixed
not cover the placement, consolidation, curing, or protection of
2
Concrete by the Volumetric Method
the concrete after delivery to the purchaser.
C 191 Test Method for Time of Setting of Hydraulic Ce-
1.2 The values stated in either SI units, shown in brackets,
3
ment by Vicat Needle
or inch-pound units are to be regarded separately as standard.
C 231 Test Method for Air Content of Freshly Mixed
The values stated in each system may not be exact equivalents;
2
Concrete by the Pressure Method
therefore, each system shall be used independently of the other.
C 260 Specification for Air-Entraining Admixtures for Con-
Combining values from the two systems may result in non-
2
crete
conformance with the standard.
C 330 Specification for Lightweight Aggregates for Struc-
1.3 As used throughout this specification the manufacturer
2
tural Concrete
shall be the contractor, subcontractor, supplier, or producer
2
C 494 Specification for Chemical Admixtures for Concrete
who furnishes the ready-mixed concrete. The purchaser shall
C 567 Test Method for Unit Weight of Structural Light-
be the owner or representative thereof.
2
weight Concrete
1.4 The text of this standard references notes and footnotes
3
C 595 Specification for Blended Hydraulic Cements
which provide explanatory material. These notes and footnotes
C 618 Specification for Coal Fly Ash and Raw or Calcined
(excluding those in tables and figures) shall not be considered
Natural Pozzolan for Use as a Mineral Admixture in
as requirements of the standard.
2
Concrete
2. Referenced Documents C 989 Specification for Ground Granulated Blast-Furnace
2
Slag for Use in Concrete and Mortars
2.1 ASTM Standards:
C 1017 Specification for Chemical Admixtures for Use in
C 31/C 31M Practice for Making and Curing Concrete Test
2
2
Producing Flowing Concrete
Specimens in the Field
2
C 1064 Test Method for Temperature of Freshly Mixed
C 33 Specification for Concrete Aggregates
2
Portland-Cement Concrete
C 39/C 39M Test Method for Compressive Strength of Cy-
2
C 1077 Practice for Laboratories Testing Concrete and Con-
lindrical Concrete Specimens
crete Aggregates for Use in Construction and Criteria for
C 109/C 109M Test Method for Compressive Strength of
2
Laboratory Evaluation
3
C 1157 Performance Specification for Hydraulic Cement
4
D 512 Test Methods for Chloride Ion in Water
1 4
This specification is under the jurisdiction of ASTM Committee C09 on D 516 Test Method for Sulfate Ion in Water
Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee
C09.40 on Ready-Mixed Concrete.
3
Annual Book of ASTM Standards, Vol 04.01.
Current edition approved February 10, 2000. Published February 2000. Origi-
4
e1
Annual Book of ASTM Standards, Vol 11.01.
nally published as C 94 – 33 T. Last previous edition C 94/C 94M–99 .
2
Annual Book of ASTM Standards, Vol 04.02.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 94/C 94M
A,B
TABLE 1 Recommended Total Air Content for Air-Entrained Concrete
Total Air Content, %
Exposure Nominal Maximum Sizes of Aggregate, in. [mm]
C
3 1 3 1
Condition
⁄8
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.