Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings

SCOPE
1.1 This specification covers requirements and test methods for fabricated or molded poly(vinyl chloride) (PVC) gasketed sewer fittings to be used with piping manufactured to Specifications D 3034, F 679, F 789, or F 891. Fabricated fittings may be manufactured from pipe, or from a combination of pipe and injection molded parts, or from injection molded parts.
1.2 The requirements of this specification are to provide fabricated or molded PVC gasketed fittings suitable for non-pressure drainage of sewage and surface water, as well as applications involving subsurface drainage.
Note 1—Industrial waste lines should be installed only with the specific approval of the governing code authority when using chemicals not commonly found in drains and sewers or temperatures in excess of 140°F (60°C), or both.
1.3 Fittings produced to this specification are intended to be installed with pipe, in accordance with Practice D 2321.
1.4 The values stated in inch-pound units are to be regarded as the standard. Within the text, the SI units are given in parentheses.
1.5 The following precautionary caveat pertains to the test method portion only, Section 10, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-May-2002
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1336-02 - Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 1336 – 02
Standard Specification for
1
Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings
This standard is issued under the fixed designation F 1336; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
3
1. Scope moplastic Pipe and Fittings
D 2321 Practice for Underground Installation of Thermo-
1.1 This specification covers requirements and test methods
plastic Pipe for Sewers and Other Gravity–Flow Applica-
for fabricated or molded poly(vinyl chloride) (PVC) gasketed
3
tions
sewer fittings to be used with piping manufactured to Specifi-
D 2412 Test Method for Determination of External Loading
cations D 3034, F 679, F 789, or F 891. Fabricated fittings may
3
Characteristics of Plastic Pipe by Parallel-Plate Loading
be manufactured from pipe, or from a combination of pipe and
D 2444 Test Method for Impact Resistance of Thermoplas-
injection molded parts, or from injection molded parts.
3
tic Pipe and Fittings by Means of a Tup (Falling Weight)
1.2 The requirements of this specification are to provide
D 2564 Specification for Solvent Cements for Poly(Vinyl
fabricated or molded PVC gasketed fittings suitable for non-
3
Chloride) (PVC) Plastic Piping Systems
pressure drainage of sewage and surface water, as well as
3
D 2749 Symbols for Dimensions of Plastic Pipe Fittings
applications involving subsurface drainage.
D 3034 Specification for Type PSM Poly(Vinyl Chloride)
NOTE 1—Industrial waste lines should be installed only with the 3
(PVC) Sewer Pipe and Fittings
specific approval of the governing code authority when using chemicals
D 3212 Specification for Joints for Drain and Sewer Plastic
not commonly found in drains and sewers or temperatures in excess of
3
Pipes Using Flexible Elastomeric Seals
140°F (60°C), or both.
D 4396 Specification for Rigid Poly(Vinyl Chloride) (PVC)
1.3 Fittings produced to this specification are intended to be
and Related Plastic Compounds for Non-Pressure Piping
installed with pipe, in accordance with Practice D 2321. 3
Products
1.4 The values stated in inch-pound units are to be regarded
F 402 Practice for Safe Handling of Solvent Cements and
as the standard. Within the text, the SI units are given in 3
Primers Used for Joining Thermoplastic Pipe and Fittings
parentheses.
3
F 412 Terminology Relating to Plastic Piping Systems
1.5 The following precautionary caveat pertains to the test
F 477 Specification for Elastomeric Seals (Gaskets) for
method portion only, Section 10, of this specification. This
3
Joining Plastic Pipe
standarddoesnotpurporttoaddressallofthesafetyconcerns,
F 610 Practice for Estimating the Quality of Molded Poly-
ifany,associatedwithitsuse.Itistheresponsibilityoftheuser
(Vinyl Chloride) (PVC) Plastic Pipe Fittings by the Heat
of this standard to establish appropriate safety and health
3
Reversion Technique
practices and determine the applicability of regulatory limita-
F 656 Specification for Primers for Use in Solvent Cement
tions prior to use.
Joints of Poly(Vinyl Chloride) (PVC) Plastic Pipe and
3
Fittings
2. Referenced Documents
F 679 Specification for Poly(Vinyl Chloride) (PVC) Large-
2.1 ASTM Standards:
3
Diameter Plastic Gravity Sewer Pipe and Fittings
D 618 Practice for Conditioning Plastics and Electrical
F 789 Specification for Type PS-46 Poly(Vinyl Chloride)
2
Insulating Materials for Testing
3
(PVC) Plastic Gravity Flow Sewer Pipe and Fittings
D 1600 Terminology for Abbreviated Terms Relating to
F 891 Specification for Coextruded Poly(Vinyl Chloride)
2
Plastics
3
(PVC) Plastic Pipe with Cellular Core
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
F 913 Specification for Thermoplastic Elastomeric Seals
Compounds and Chlorinated Poly(Vinyl Chloride)
3
(Gaskets) for Joining Plastic Pipe
2
(CPVC) Compounds
2.2 Federal Standard:
D 2122 Test Method for Determining Dimensions of Ther-
4
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2.3 Military Standard:
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
3
Current edition approved May 10, 2002. Published July 2002. Originally Annual Book of ASTM Standards, Vol 08.04.
4
published as F 1336 – 91. Last previous edition F 1336 – 01. AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
2
Annual Book of ASTM Standards, Vol 08.01. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 -------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.