EN 10001:1990
(Main)Definition and classification of pig-irons
Definition and classification of pig-irons
This annex is applicable to pig-iron in the solid state, unless otherwise agreed at the time of ordering
Begriffsbestimmung und Einteilung von Roheisen
Verstaendigung und Kommunikation.
Définition et classification des fontes brutes
Compréhension mutuelle et communication.
Definicija in razvrščanje grodljev
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Begriffsbestimmung und Einteilung von RoheisenDéfinition et classification des fontes brutesDefinition and classification of pig-irons77.080.10ŽelezoIrons01.040.77Metalurgija (Slovarji)Metallurgy (Vocabularies)ICS:Ta slove
...
This May Also Interest You
This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing.
NOTE 1 It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2 When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about:
— type testing conditions, test procedures and test requirements;
— analyser performance requirements;
— evaluation of the type testing results;
— evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about:
— initial installation of the analyser in the monitoring network and acceptance testing;
— ongoing quality assurance/quality control;
— calculation and reporting of measurement results;
— evaluation of the uncertainty of the measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
- Draft108 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 13.040.20
- 2008/50/EC
- CEN/TC 264
This document specifies the requirements relating to:
Steel X6CrNiTi18-10 (1.4541)
Air melted
Softened
Plates
6 mm < a ≤ 50 mm
500 MPa ≤ Rm ≤ 700 MPa
for aerospace applications.
W.nr: 1.4541.
ASD-STAN designation: FE-PA3601.
- Standard9 pagesEnglish languagesale 10% offe-Library read for×1 day
1.1 Scope of EN 16905 series
This series specifies the requirements, test methods and test conditions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor.
This series is used in conjunction with:
a) the terms and definitions, EN 16905 1:2023;
b) the safety, EN 16905 2:—1;
c) the requirements, test conditions and test methods, EN 16905 4:—2;
d) the calculation of seasonal performances in heating and cooling mode, EN 16905‐5:2022;
e) the heat pump standards, EN 14511‐2:2022, EN 14511 3:2022 and EN 14825:2022.
This series only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This series only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This series only applies to appliances having:
a) gas-fired endothermic engines under the control of fully automatic control systems;
b) closed-system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c) where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the
1) heating water circuit (if installed) does not exceed 6 bar;
2) domestic hot water circuit (if installed) does not exceed 10 bar.
This series applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This series is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
1.2 Scope of EN 16905 3
This part of the EN 16905 series specifies the test conditions for the rating of energy parameters of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the three-pole temperature compensated circuit breakers, rated from 1 A to 25 A used in aircraft on-board circuits. It describes specific environmental, electrical and mechanical characteristics and the stringency of tests to be applied according to test methods of EN 3841 100.
These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a method to determine the friction characteristics of geosynthetics (geotextiles and geotextile-related products, geosynthetic barriers) in contact with soils or another geosynthetic, at low normal stress, using an inclining plane apparatus.
This test method is primarily intended as a performance test to be used with site specific soils but is also used as an index test with standard sand. It is also possible to measure the displacement of the interface over time (creep phenomenon) without necessarily reaching the slippage failure.
Test data obtained for geogrids tested with a rigid support are not necessarily realistic as the results depend on the friction support.
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 59.080.70
- CEN/TC 189
This European Standard specifies a continuous measurement method for the determination of the concentrations of ozone present in ambient air based on the ultraviolet photometric measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet photometric analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of ozone present in ambient air up to 500 μg/m3.
This concentration range represents the certification range for ozone for the type approval test.
NOTE 1 Other ranges may be used for measurement systems applied at rural locations monitoring ecosystems.
NOTE 2 When the standard is used for other purposes than Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of ozone in zones classified as rural areas, urban and urban-background areas.
The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 500 μg/m3 of O3 corresponds to 250 nmol/mol of O3 at 20 °C and 101,3 kPa.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes B and C contain general information about the principles of ozone measurement by ultraviolet photometric analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of ozone analysers. These sections contain information about:
− type-approval test conditions, test procedures and test requirements;
− analyser performance requirements;
− evaluation of the type-approval test results;
− evaluation of the uncertainty of the measurement results of the ozone analyser based on the type-approval test results.
Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical
measurements of ozone in ambient air. These sections contain information about:
− initial installation of the analyser in the monitoring network and acceptance testing;
− ongoing quality assurance/quality control;
− calculation and reporting of measurement results;
− evaluation of the uncertainty of measurement results under practical monitoring conditions.
- Draft110 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 13.040.20
- 2008/50/EC
- CEN/TC 264
This document specifies the single-pole temperature compensated circuit breakers rated from 1 A to 25 A and used in aircraft on-board circuits. It describes specific environmental, electrical and mechanical characteristics and the stringency of tests to be applied according to test methods of EN 3841-100.
These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements for the design and installation of early suppression fast response (ESFR) and control mode specific application (CMSA) sprinklers in automatic sprinkler systems, in accordance with this standard and additionally the EN 12845 series of standards.
This document does not cover all legislative requirements.
NOTE In certain countries, specific national regulations can apply. Attention is drawn to the applicability or non-applicability for this document as specified by national responsible authorities.
- Standard60 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 13.220.20
- CEN/TC 191
This document specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use-products - with water. Products can only be tested at a concentration of 80 % or less, as some dilution is always produced by adding the test organisms and interfering substance.
This document applies to products that are used in the veterinary area - i.e. in the breeding, husbandry, production, veterinary care facilities, transport and disposal of all animals except when in the food chain following death and entry into processing industry. This document also applies to products used for teat disinfection.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
- Draft44 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 71.100.35
- CEN/TC 216
This document deals with the classification of glassfibre reinforced concrete. This classification conforms to the needs of the design process of glassfibre reinforced concrete components. This document applies only if EN 1169 is followed.
This document does not deal with design methods.
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 91.100.30
- CEN/TC 229
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.