Road vertical signs - Variable message traffic signs - Part 1: Product standard

This document specifies requirements and test methods for new Variable Message Signs (VMS).
VMS comprise two types, continuous and discontinuous signs:
- continuous signs are those that are similar to fixed signs, the only difference being that by some
electro-mechanical means they can show various messages.
NOTE 1 For example rotating prism signs, roller blinds.
- discontinuous signs create messages using individual elements that can be in one of two states (or more)
and can thereby create various messages on the same sign face.
NOTE 2 For example fibre optic signs, LED signs.
This document covers the performance requirements for Variable Message Signs used for the instruction and
guidance of road users on public and private land, including tunnels. In this document a number of different
performance requirements (visual performance, EMC, environmental performance, etc) are covered, as well
as durability.
The EMC, safety and environmental requirements for both types of VMS are included in this document
together with the visual performance for the discontinuous types VMS.
The visual performance for continuous signs and discontinuous signs which are externally illuminated is
covered by EN 12899-1.
This document defines performance limits and a range of performance classes for both sign assemblies
without vertical support and assemblies complete with vertical support.
Not covered by this document are:
a) sign gantries, cantilevers and foundations;
b) portable and temporary VMS;
c) signal heads;
d) sizes and shapes of VMS messages;
e) control units and monitoring units unless inside the test module.

Vertikale Verkehrszeichen - Wechselverkehrszeichen - Teil 1 : Produktnorm

Signaux de signalisation routière verticale - Panneaux à messages variables - Partie 1: Norme produit

Pokončni cestni znaki - Prometni znaki s spremenljivim sporočilom - 1. del: Standard za proizvod

General Information

Status
Not Published
Current Stage
3098 - Decision to reject - Consensus building
Start Date
21-Sep-2007
Completion Date
21-Sep-2007

Relations

Buy Standard

Draft
EN 12966-1:2005/kprA1:2009 - BARVE
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 12966-1:2005/kprA1:2009
01-junij-2009
3RNRQþQLFHVWQL]QDNL3URPHWQL]QDNLVVSUHPHQOMLYLPVSRURþLORPGHO
6WDQGDUG]DSURL]YRG
Road vertical signs - Variable message traffic signs - Part 1: Product standard
Vertikale Verkehrszeichen - Wechselverkehrszeichen - Teil 1: Produktnorm
Signaux de signalisation routière verticale - Panneaux à messages variables - Partie 1:
Norme produit
Ta slovenski standard je istoveten z: EN 12966-1:2005/prA1
ICS:
93.080.30 Cestna oprema in pomožne Road equipment and
naprave installations
SIST EN 12966-1:2005/kprA1:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 12966-1:2005/kprA1:2009

---------------------- Page: 2 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EUROPEAN STANDARD
FINAL DRAFT
EN 12966-1:2005
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
April 2009
ICS 93.080.30

English Version
Road vertical signs - Variable message traffic signs - Part 1:
Product standard
Signaux de signalisation routière verticale - Panneaux à Vertikale Verkehrszeichen - Wechselverkehrszeichen - Teil
messages variables - Partie 1: Norme produit 1: Produktnorm
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 226.
This draft amendment A1, if approved, will modify the European Standard EN 12966-1:2005. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12966-1:2005/prA1:2009: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)
Foreword
This document (EN 12966-1:2005/prA1:2009) has been prepared by Technical Committee CEN/TC 226 "Road
equipment", the secretariat of which is held by AFNOR.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
Annex ZA includes the requirements of the Mandate given under the EU Construction Products Directive (89/106).
Only if the requirements specified in Annex ZA are met, the CE marking will be affected.
The amendment of the following parts of EN 12966:2005 have become necessary in the light of experience in
using the standard.
2

---------------------- Page: 4 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)

1 Modifications to the Foreword
th
Replace the 6 paragraph with the following:

"Road vertical signs - Variable message traffic signs
- Part 1: (this part) Variable message signs (VMS)
- Part 2: Initial type testing
- Part 3: Factory production control".


Before the last paragraph add the following new paragraph: "Where a Member State has no legal requirement for a
characteristic manufacturers are not required to determine or declare the value of that characteristic."


2 Modification to the Introduction
Add the following new paragraph at the end:
"In Member States which have no legal requirement for any of the characteristics in this standard manufacturers
are not required to determine and declare the performance of those characteristics."

3 Modification to the Scope
Paragraph 5, line 1, add “externally illuminated” after “continuous signs and”.
Paragraph 7, delete exclusion “b) Portable and temporary VMS” and renumber accordingly.
Add the following new item: "e) sign luminance control."
Add the following new paragraph: "The control of the luminance of luminous signs with respect to the ambient light
is not covered by this standard."

4 Modification to Clause 2, Normative references
Replace the title of EN 60068-2-64 with "Environmental testing — Part 2: Test methods — Test Fh: Vibration,
broad band random (digital control) and guidance (IEC 60068-2-64;1993 + Corrigendum 1993)".

5 Modification to Clause 5, General design requirements
In the note, replace “Informative” with “informative”.

6 Modification to 7.1, Classification
In note 2, delete “Annex E” and replace with “D.3".
3

---------------------- Page: 5 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)
In note 2, delete “effective”.

7 Modification to 7.3, Luminance
st
Delete the 1 paragraph and replace with the following:
“The luminance shall be measured in accordance with 9.3.2, under external illumination from a solar simulator and
with the test module switched on. 'With settings prescribed by the manufacturer, the luminance values measured
for the test module shall comply with those of the Tables 4a to 4f that are relevant for the colours produced by the
test module."
Add the following new note: “NOTE 2 Specific design issues are covered in D.3, where guidelines are given on class
combinations.”
Replace "NOTE" with "NOTE 1".
Paragraph 4, line 1 replace “For” with “Additionally, for”.

8 Modification to 7.4, Luminance ratio
Paragraph 1, line 3, replace "9.3.2.4” with “9.3.2.3”.

Delete the following last sentence: “Class R3 is only recommended for specific applications, see E.5 Effective
class-combinations”.

Add “NOTE 2 Specific design issues are covered in D.3, where guidelines are given on class combinations.”.

st
Renumber the 1 note "NOTE 1".


9 Modification to 7.5, Beam width
nd
Replace the 2 paragraph with the following:
“Within the beam width angles, the measured luminance shall not be lower than 50 % of the measured luminance
on the reference axis. Table 6 shows the seven beam width classes.”
Replace the Note with the following:
“NOTE 1 Figure 2 shows examples of passed and not passed luminance distributions for the white/yellow colour, class
luminance L3, and beam width class B2 at a sign illuminance of 40 000 lx.
NOTE 2 Specific design issues are covered in D.3, where guidelines are given on class combinations.”
In Figure 2, delete key 3) and renumber the rest.
After Figure 2 add the following new paragraph:
2
“The luminance for this colour at the reference axis should be in the range 10 540 to 52 700 cd/m . Suppose the
2
actual measured luminance at the reference axis obeys this requirement and is 30 000 cd/m . Then the maximum
2
luminance at all other angles is 1,5 ×× ××  30 000 = 45 000 cd/m . The minimum luminance at within the beam width
2
angles shall not be lower than 0,5 ×× ××  30 000 = 15 000 cd/m . Outside the beam width angles the luminance is
2
allowed to be zero, but never larger than 57 200 cd/m .”
4

---------------------- Page: 6 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)
10 Modification to 8.1, Classification
In Table 7, delete row 2 and substitute the following:

“Protection P1, P2, P3 P3 is the most restrictive”


11 Modification to 8.2.2
Replace the heading with the following: “Resistance of electrical / electronic components to the effects of pollution”
st
In the 1 paragraph, delete “state” and substitute “declare”.

Delete the remaining paragraphs.


12 Modification to 8.2.4, Degrees of protection provided by enclosures (IP-level)
st
1 paragraph, line 2, add “test modules with a pollution degree level of 2, 3 or 4 shall” after “EN 60529 category 2)
and”.

In Table 9, change IP45 to IP 44, IP55 to IP54 and IP66 to IP56.

13 Modification to 8.3.1, General
st
Insert as 1 paragraph the following:
“VMS shall be designed to ensure reliable transfer of all static and dynamic forces to the fixing and mounting
structures. The walls of the housing shall be designed to satisfy the static requirements.”

14 Modification to 8.3.4, Impact resistance
Replace the existing text with the following:
“The test modules shall be capable of withstanding impact, and shall be tested in accordance with 9.2.3 Table 13.
After the test the test module front panel or parts of it shall show no damage other then small indentations in the
front surface; it shall exhibit no cracking.
The test module shall continue to meet all the requirements of the standard”


15 Modification to 8.4.1.2, Nominal voltages

Add the following note:
"NOTE Where low voltages are used, these should be as declared by the manufacturer."


16 Modification to 9.1.2, Dimensions of test modules

nd
At the end of the 2 paragraph add the following: ”Where a production sign is used for testing, the manufacturer
shall identify the test area which shall be as defined in 9.3.2.2.”


17 Modification to 9.2.3, Environmental and mechanical tests

In Table 13, last section
5

---------------------- Page: 7 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)
Replace “and the” with “other than small indentations in the front surface; it shall exhibit no cracking. The”

rd th
In Table 14, replace the 3 column, 4 row with the following

"0,013 g²/Hz (10 Hz to 50 Hz)
0,013 g²/Hz (50 Hz to 200 Hz with a negative slope 3 dB/octave)
Overall RMS acceleration 1,2 g"


In Table 16 - Severity
Replace "IP x5" to "IP x4" in class P1 and P2 to conform to changes in 8.2.4, Table 9.

Table 17 – Severity
Replace "IP 6x" with "IP 5x" in Class P 3 to conform to changes in 8.2.4, Table 9.

18 Modification to 9.3, Optical performance test methods
Delete title “9.3.2 Luminance and luminance ratio”

Delete “9.3.2.1”

Add title “9.3.2 Luminance and luminance ratio” after “The illumination shall be measured in the reference centre,
perpendicular to the reference axis.”


19 Modification to 9.3.2.1
Replace the title of this subclause with “Solar simulator”.

20 Modification to 9.3.3, Beam width
Add the following note:
“NOTE Beam width may be obtained by measuring luminance intensity and calculating the luminance using the equivalent
area.”

21 Modification to 9.3.4, Uniformity
nd
In the 2 paragraph, replace "Table 20" with "Table 19".
rd
Add the following 3 paragraph:
“A minimum of 25 individual elements shall be measured.”


22 Modification to 9.3.5, Colour
rd
Replace the 3 paragraph with the following:
“The colour of the light emitted shall be carried out for the highest and the lowest setting specified by the
manufacturer according to 7.3.”

6

---------------------- Page: 8 ----------------------

SIST EN 12966-1:2005/kprA1:2009
EN 12966-1:2005/prA1:2009 (E)
23 Modification to Clause 10, Product classification codes
Item b), delete” D3” from list.

Delete “Pollution D1, D2, D3 & D4”. Renumber the remaining item 3) into 2).

24 Modification to Annex A
In Equation (A.1) add “measured in the direction of reference axis” to definition of “L”.

25 Modification to Annex
...

Questions, Comments and Discussion