FprEN 16510-2-2
(Main)Residential solid fuel burning appliances - Part 2-2: Inset appliances including open fires
Residential solid fuel burning appliances - Part 2-2: Inset appliances including open fires
This Part 2-2 of EN 16510 is applicable to hand fed solid fuel fired inset appliances, with or without functional modification, that operate without firedoors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel. The surround of these appliances are integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure. These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating.
These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions.
This Part 2-2 of EN 16510 also covers ‘Kachelofen’ and ‘Putzofen’ inset appliances, having nominal heat outputs up to 15 kW prEN 16510-1
This Part 2-2 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this Part 2-2 of EN 16510.
This Part 2-2 of EN 16510 is to be used in conjunction with EN 16510-1 of which it is an integral part.
Häusliche Feuerstätten für feste Brennstoffe - Teil 2-2: Kamineinsätze einschließlich offene Kamine
Diese Europäische Norm gilt für handbeschickte Festbrennstofffeuerstätten, mit und ohne funktionalen Änderungen, die ohne Feuerraumtüren oder mit Feuerraumtüren, die entweder nur geschlossen oder offen und geschlossen betrieben werden können, und einschließlich offener Kamine, die mit festen Brennstoffen befeuert werden. Die Verkleidung dieser Feuerstätten ist mit dem Gebäude verbunde, mit Ausnahme von freistehenden Feuerstätten und den Einsätze, die in eine Feuerstätten-Nische oder Verkleidung eingestellt werden. Diese Feuerstätten beheizen den Aufstellungsraum. Zusätzlich, sofern mit wasserführenden Bauteilen ausgestattet, liefern sie Heizwasser und/oder dienen der Zentralbeheizung.
Die Feuerstätten, die mit diesem Teil 2-2 der EN 16510 abgedeckt werden, beheizen den Aufstellungsraum. Sofern sie mit wasserführenden Bauteilen ausgestattet sind, liefern sie Heizwasser und/oder dienen der Zentralbeheizung. Diese Feuerstätten können entsprechend der Bedienungsanleitung des Herstellers entweder feste mineralische Brennstoffe, Torfbriketts, Holzscheite, Holzbriketts oder mehrere dieser Brennstoffe verfeuern.
Diese Europäische Norm erfasst auch Heizeinsätze für Kachelöfen und Putzöfen bis zu einer Nennwärmeleistung von 15 kW, die der Kategorie 1c der prEN 16510-1:2013, Tabelle 1, zuzuordnen sind.
Dieser Teil 2-2 der EN 16510 gilt nicht für Feuerstätten mit Verbrennungsluftgebläse oder mechanisch beschickte Feuerstätten.
Bauteile für offene Feuerstätten wie ein Bodenrost mit zugehöriger Frontplatte, die vom Hersteller zum Einbau in einen vorhandenen brandsicheren und wärmegedämmten Raum geliefert werden, werden von diesem Teil 2 2 der EN 16510 nicht erfasst.
Appareils de chauffage domestiques à combustible solide - Partie 2-2: Foyers ouverts et inserts
La présente Partie 2-2 de l'EN 16510 s'applique aux inserts à combustibles solides à alimentation manuelle, avec ou sans modification fonctionnelle, qui fonctionnent sans porte foyère ou avec des portes foyères soit uniquement fermées, soit fermées ou ouvertes, ainsi qu’aux foyers ouverts à combustible solide. L'habillage de ces appareils est intégré dans le bâtiment, à l'exception des appareils indépendants et des inserts qui sont installés dans une niche ou une enceinte. Ces appareils produisent de la chaleur dans l’espace où ils sont installés. De plus, lorsqu’ils sont équipés d’un bouilleur, ils produisent également de l’eau chaude à usage domestique et/ou du chauffage central.
Les appareils couverts par la présente Partie 2-2 de l'EN 16510 produisent de la chaleur dans l’espace où ils sont installés. De plus, lorsqu’ils sont équipés d’un bouilleur, elles produisent également de l’eau chaude à usage domestique et/ou du chauffage central. Ces appareils peuvent utiliser soit des combustibles minéraux solides, des briquettes de tourbe, des bûches de bois naturel ou reconstitué, soit plusieurs combustibles conformément aux instructions du fabricant de l'appareil.
La présente Partie 2-2 de l'EN 16510 concerne également les inserts « Kachelofen » et « Putzofen » dont la puissance thermique nominale est inférieure ou égale à 15 kW, conformément à la catégorie lc du Tableau 1 du prEN 16510-1:2013.
La présente Partie 2-2 de l'EN 16510 ne s'applique pas aux appareils équipés d'un ventilateur pour l'alimentation en air de combustion ou aux appareils à alimentation mécanique.
Les éléments de cheminée ouverte, tels que grille et devanture de foyer associée que le fabricant fournit pour une installation dans un foyer existant, thermiquement isolé et constitué de matériaux réfractaires, ne sont pas concernés par la présente Partie 2-2 de l'EN 16510.
Stanovanjske grelne naprave na trdna goriva - 2-2. del: Kaminski vložki, vključno odprti kamini na trdna goriva
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 16510-2-2:2013
01-marec-2013
6WDQRYDQMVNHJUHOQHQDSUDYHQDWUGQDJRULYDGHO.DPLQVNLYORåNLYNOMXþQR
RGSUWLNDPLQLQDWUGQDJRULYD
Residential solid fuel burning appliances - Part 2-2: Inset appliances including open fires
Häusliche Heizgeräte für feste Brennstoffe - Teil 2-2: Kamineinsätze einschließlich
offene Kamine
Equipement de chauffage domestique - Partie 2-2 : Foyers ouverts et insert
Ta slovenski standard je istoveten z: prEN 16510-2-2
ICS:
97.100.30 Grelniki na trdo gorivo Solid fuel heaters
oSIST prEN 16510-2-2:2013 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST prEN 16510-2-2:2013
oSIST prEN 16510-2-2:2013
EUROPEAN STANDARD
DRAFT
prEN 16510-2-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2013
ICS 97.100.30 Will supersede EN 13229:2001
English Version
Residential solid fuel burning appliances - Part 2-2: Inset
appliances including open fires
Equipement de chauffage domestique - Partie 2-2 : Foyers Häusliche Heizgeräte für feste Brennstoffe - Teil 2-2:
ouverts et insert Kamineinsätze einschließlich offene Kamine
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 295.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16510-2-2:2013: E
worldwide for CEN national Members.
oSIST prEN 16510-2-2:2013
prEN 16510-2-2:2013 (E)
Contents Page
Foreword .3
1 Scope .4
2 Normative references .4
3 Terms and definitions .4
4 Classification of appliances and system boundary for roomsealed appliances .4
5 Materials, design and construction .4
6 Safety requirements .5
7 Performance requirements .5
8 Appliance instructions .7
9 Evaluation of conformity .7
10 Marking .7
Annex A (normative) Test methods .8
Annex B (normative) Test fuels and recommended fuels. 17
Annex C (informative) Installation for roomsealed appliances . 18
Annex D (informative) Arrangement for measuring the leakage rate . 19
Annex E (normative) Measuring procedure for nitrogen oxides (NO ). 20
x
Annex F (normative) Measuring procedure for organic gaseous compounds (OGC) . 21
Annex G (normative) Measuring procedure for particulate matter (PM) . 22
Annex H (informative) Guideline for the characteristics to be taken into account in order to decide
on families of appliances . 23
Annex AA (informative) Example for the possibility to extrapolate the steady state condition from
a curve of temperature measurements of at least 8 h . 24
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU
Construction Products Directive . 26
oSIST prEN 16510-2-2:2013
prEN 16510-2-2:2013 (E)
Foreword
This document (prEN 16510-2-2:2013) has been prepared by Technical Committee CEN/TC 295 “Residential
solid fuel burning appliances”, the secretariat of which is held by BSI.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 13229:2001.
EN 13240:2001, EN 13229:2001, EN 12815:2001 and EN 12809:2001 will be totally superseded by EN 16510
series. The revision of these European Standards takes into account the comments received at their 5-year
review.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive 89/106/EEC, see informative Annex ZA, which is an integral part of this
document.
The structure of EN 16510, Residential solid fuel burning appliances, is as follows:
Part 1: General requirements and test methods;
Part 2-1: Roomheaters;
Part 2-2: Inset appliances including open fires;
Part 2-3: Cookers;
Part 2-4: Independent boilers – Nominal heat output up to 50 kW.
Principally it is possible to add further parts 2 at a later stage in order to cover other residential solid fuel
burning appliances such as pellet stoves or slow heat release appliances.
This Part 2-2 is to be used in conjunction with the latest edition of EN 16510-1 and its amendments. It was
established on the basis of prEN 16510-1:2013.
This Part 2-2 supplements or modifies the corresponding clauses in EN 16510-1, so as to convert that
publication into the European Standard: Residential solid fuel burning appliances – Requirements and test
methods for inset appliances including open fires.
When a particular subclause of Part 1 is not mentioned in this Part 2-2, that subclause applies as far as is
reasonable. When this Part 2-2 states "addition", "modification" or "replacement", the relevant text in Part 1 is
to be adapted accordingly.
NOTE The following numbering system is used:
subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including those
in a replaced clause or subclause;
additional annexes are lettered AA, BB, etc.
oSIST prEN 16510-2-2:2013
prEN 16510-2-2:2013 (E)
1 Scope
This Part 2-2 of EN 16510 is applicable to hand fed solid fuel fired inset appliances, with or without functional
modification, that operate without firedoors or operate with fire doors either as closed only or as closed or
open, and also includes open fires fired by solid fuel. The surround of these appliances are integrated with the
building with the exception of free-standing appliances and those inset appliances which are installed into a
fireplace recess or enclosure. These appliances provide heat into the space where they are installed.
Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating.
The appliances covered by this Part 2-2 of EN 16510 provide heat into the space where they are installed.
Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These
appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-
fuel in accordance with the appliance manufacturer’s instructions.
This Part 2-2 of EN 16510 also covers ‘Kachelofen’ and ‘Putzofen’ inset appliances, having nominal heat
outputs up to 15 kW in accordance with category lc of prEN 16510-1:2013, Table 1.
This Part 2-2 of EN 16510 is not applicable to appliances with fan assisted combustion air or appliances that
are mechanically fired.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies
for installation into an existing heat resistant, insulated firebox are not covered by this Part 2-2 of EN 16510.
2 Normative references
prEN 16510-1:2013, Clause 2, is applicable with the following modification.
Addition
DIN 51060, Refractory ceramic raw materials and refractories — Definitions of the terms refractory, high
refractory
3 Terms and definitions
prEN 16510-1:2013, Clause 3 is applicable.
4 Classification of appliances and system boundary for roomsealed appliances
prEN 16510-1:2013, Clause 4, is applicable.
5 Materials, design and construction
prEN 16510-1:2013, Clause 5, is applicable with the following modifications.
5.2.5 Flueways
prEN 16510-1:2013, 5.2.5, is applicable with the following modification.
st
Addition after 1 paragraph:
For Kachelofen or Putzöfen inset appliances the flueways shall be tight and shall have tight cleaning
openings, which allow a proper cleaning. Metal flueways shall be made of steel as given in
prEN 16510-1:2013, Table 3, with a minimum thickness of 2 mm or cast iron as given in prEN 16510-1:2013,
Table 4, with a thickness of 4 mm or of austenitic stainless steel with a thickness of 1 mm. Fireclay bricks,
plates or components of flueways shall comply with DIN 51060.
oSIST prEN 16510-2-2:2013
prEN 16510-2-2:2013 (E)
5.2.6 Ashpan and ash removal
prEN 16510-1:2013, 5.2.6, is applicable with the following modification.
st
Addition after 1 paragraph:
Kachelöfen or Putzöfen inset appliances designed to burn coal as well as wood shall be equipped with an
ashpan having a minimum volume capacity of 0,8 dm per kW of nominal heat output. For Kachelöfen' or
Putztöfen' insets which are specifically designed to burn wood logs and wood briquettes, and if they are
equipped with an ashpan, the minimum volume capacity of this ashpan shall be 0,5 dm per kW of nominal
heat output.
5.2.7 Bottomgrate
prEN 16510-1:2013, 5.2.7, is applicable with the following modification.
st
Addition after 1 paragraph and Note:
Grate devices fitted to Kachelöfen or Putztöfen inset appliances shall be easy to de-ash without undue effort.
6 Safety requirements
prEN 16510-1:2013, Clause 6, is applicable with the following modification.
Addition of the following new subclauses
6.101 Cut-off device for appliances without doors
If a cut-off device is fitted to an appliance without doors, it shall separate the appliance from the chimney. The
cut-off device shall not hinder control or cleaning of the connecting parts, and the device shall maintain the
position in which it is set.
The marking of the position of the operating handle shall enable identification of the position of the cut-off
device. The cut-off device shall only be installed into the flue gas collector, flue spigot or flue gas connector
and it shall separate the flueway from the chimney. The cut-off device shall only be used when the appliance
is out to prevent heat loss from the room via the chimney and to prevent the fall of soot into the room when the
chimney is swept.
6.102 Temperature at air grilles for Kachelöfen or Putzöfen inset appliances
For the test in compliance with A.4.7 and A.4.101 the temperature recorded at the central flow at a distance of
15 cm from outside of the air grilles shall not be greater than 85 °C when referenced to an ambient
temperature of 25 °C.
7 Performance requirements
prEN 16510-1:2013, Clause 7, is applicable with the following modifications.
7.2.2 Carbon monoxide emission
prEN 16510-1:2013, 7.2.2, is applicable with the following modification.
Addition after 1st paragraph:
For Kachelofen or Putztofen inset appliances, when tested in accordance with A.4.7 and A.4.101 the mean
carbon monoxide content of the dry flue gas shall not exceed 0,2 % related to 13 % O when the test fuels
corresponding to prEN 16510-1:2013, Table B.1, are burned.
oSIST prEN 16510-2-2:2013
prEN 16510-2-2:2013 (E)
7.3 Efficiency
prEN 16510-1:2013, 7.3, is applicable with the following modification.
Addition after 1st paragraph:
For Kachelofen and Putzofen inset appliances the manufacturer's declared efficiency value shall be equal to
or exceed 75 %.
For open fires without boiler the manufacturer's declared efficiency value shall be equal to or exceed 30 %.
For open fires with boiler the manufacturer's declared efficiency value shall be
...