Wall-hung urinals - Functional requirements and test methods

This European Standard specifies constructional and performance requirements together with test methods for wall-hung urinals made of vitreous china or stainless steel that are used for personal hygiene.
This European Standard does not apply to slab and stall urinals nor to waterless urinals.

Wandhängende Urinale - Funktionsanforderungen und Prüfverfahren

Diese Norm legt Baugrundsätze, funktionelle Anforderungen an Hygiene und Gebrauchstauglichkeit sowie Prüfverfahren für wandhängende Urinale, hergestellt aus kermischen Werkstoffen oder nichtrostendem Stahl, fest. Diese Norm gilt nicht für Urinalstände und Urinalwände.

Urinoirs muraux - Prescriptions fonctionnelles et méthodes d'essai

Cette Norme Européenne spécifie les prescriptions relatives à la construction et à la performance des urinoirs
muraux en céramique sanitaire émaillée ou en acier inoxydable utilisés pour l’hygiène personnelle ainsi que
les méthodes d’essai correspondantes.
Cette Norme Européenne ne s’applique ni aux plaques et stalles d’urinoirs ni aux urinoirs sans eau.

Zidni pisoar – Funkcionalne zahteve in preskusne metode

General Information

Status
Withdrawn
Publication Date
03-Oct-2006
Withdrawal Date
21-Jul-2015
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
22-Jul-2015

Relations

Buy Standard

Standard
EN 13407:2007
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Wall-hung urinals - Functional requirements and test methodsZidni pisoar – Funkcionalne zahteve
in preskusne metodeUrinoirs muraux - Prescriptions fonctionnelles et méthodes d'essaiWandhängende Urinale - Funktionsanforderungen und PrüfverfahrenTa slovenski standard je istoveten z:EN 13407:2006SIST EN 13407:2007en91.140.70Sanitarne napraveSanitary installationsICS:SLOVENSKI
STANDARDSIST EN 13407:200701-januar-2007

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13407October 2006ICS 91.140.70 English VersionWall-hung urinals - Functional requirements and test methodsUrinoirs muraux - Prescriptions fonctionnelles et méthodesd'essaiWandhängende Urinale - Funktionsanforderungen undPrüfverfahrenThis European Standard was approved by CEN on 28 August 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13407:2006: E

Test rig for urinals intended to be flushed by a flush valve.17 Annex B (normative)
Test rig for urinals intended to be flushed by a manually operated flushing cistern.19 Annex C (normative)
Test rig for urinals intended to be flushed by an automatic flushing cistern with valve-less outlet device.23

Clauses of this European Standard addressing the provisions of EU Construction Products Directive.25 Bibliography.29

Figure 1 — Wall-hung urinal 3.2 slab urinal sanitary appliance comprising a floor channel and a slab or sheet fixed to a wall, for receiving urine and water used for flushing and directing both into a drainage system (see Figure 2)
Figure 2 — Slab urinal
Figure 3 — Stall urinal 3.4 urinal with siphonic action urinal in which urine is removed by siphonage (suction) induced by flushing water flowing through either an integral trap or a dedicated separate trap assembled in accordance with the manufacturer's instruction 3.5 wash-down urinal non-siphonic acting urinal with or without integral trap 3.6 waterless urinal sanitary appliance for receiving urine and directing it into a drainage system, which functions without the use of water 3.7 flushing cistern cistern for storage and discharge of a defined volume of flushing water for removal of urine from urinals 3.8 flush valve valve connected directly to a water supply, which delivers a pre-determined volume of flushing water for removal of urine from a urinal 3.9 cleanability characteristics which allow surfaces intended to come into contact with water and/or urine and cleansing materials to be visibly smooth, non-absorbent and free from acute internal corners, such that they can be kept visibly free from dirt and/or stains when subject to a regular maintenance regime, which may include, when appropriate, specific instructions for use and care specified by the manufacturer 4 Principles of design 4.1 General Wall-hung urinals in accordance with Table 1 shall meet the following requirements:  for connection to supply and drainage systems the connecting dimensions shall be in accordance with EN 80 or the manufacturer shall provide or recommend necessary auxiliary components;  wall-hung urinals shall function with flushing device(s) supplying flushing volumes and/or flow rates as specified by the manufacturer in accordance with Table 2.

Table 1 — Types of wall-hung urinals Type Construction I Siphonic action urinal with flushing rim and with integral trap or with dedicated trap specified by the manufacturer II Wash-down urinal with or without flushing rim and with integral trap or with dedicated trap specified by the manufacturer III Wash-down urinal with or without flushing rim and w
...

Questions, Comments and Discussion