Fertilizers and liming materials - Determination of arsenic by inductively coupled plasma-atomic emission spectrometry (ICP-AES) after aqua regia dissolution

EN 16317:2013 will be amended taking into account liming materials in the scope of the method. Clause 10 Precision and Annex A Results of the inter-laboratory test will be amended by addition of the precision data received from the inter-laboratory test performed in 2013 analysing samples of liming materials. The main title of the document will be extended to liming materials to read: Fertilizers and liming materials.

Düngemittel und Kalkdünger - Bestimmung von Arsen mit Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-AES) nach Königswasseraufschluss

Engrais et amendements minéraux basiques - Détermination de l'arsenic par spectrométrie d'émission atomique avec plasma induit par haute fréquence (ICP-AES) après digestion á l'eau régale

Gnojila in sredstva za apnjenje - Določevanje arzena z atomsko emisijsko spektrometrijo z induktivno sklopljeno plazmo (ICP/AES) po raztapljanju v zlatotopki - Dopolnilo A1

General Information

Status
Not Published
Current Stage
5060 - Closure of Vote - Formal Approval
Start Date
10-Nov-2016
Due Date
11-Mar-2017
Completion Date
10-Nov-2016

Relations

Buy Standard

Draft
EN 16317:2013/oprA1:2015
English language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 16317:2013/oprA1:2015
01-september-2015
*QRMLODLQVUHGVWYD]DDSQMHQMH'RORþHYDQMHDU]HQD]DWRPVNRHPLVLMVNR
VSHNWURPHWULMR]LQGXNWLYQRVNORSOMHQRSOD]PR ,&3$(6 SRUD]WDSOMDQMXY
]ODWRWRSNL
Fertilizers and liming materials - Determination of arsenic by inductively coupled plasma-
atomic emission spectrometry (ICP-AES) after aqua regia dissolution
Düngemittel und Kalkdünger - Bestimmung von Arsen mit Atomemissionsspektrometrie
mit induktiv gekoppeltem Plasma (ICP-AES) nach Königswasseraufschluss
Engrais et amendements minéraux basiques - Détermination de l'arsenic par
spectrométrie d'émission atomique avec plasma induit par haute fréquence (ICP-AES)
après digestion á l'eau régale
Ta slovenski standard je istoveten z: EN 16317:2013/prA1
ICS:
65.080 Gnojila Fertilizers
SIST EN 16317:2013/oprA1:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 16317:2013/oprA1:2015

---------------------- Page: 2 ----------------------

SIST EN 16317:2013/oprA1:2015

EUROPEAN STANDARD
DRAFT
EN 16317:2013
NORME EUROPÉENNE

EUROPÄISCHE NORM
prA1
June 2015
ICS 65.080
English Version
Fertilizers and liming materials - Determination of arsenic by
inductively coupled plasma-atomic emission spectrometry (ICP-
AES) after aqua regia dissolution
Engrais et amendements minéraux basiques - Düngemittel und Kalkdünger - Bestimmung von Arsen mit
Détermination de l'arsenic par spectrométrie d'émission Atomemissionsspektrometrie mit induktiv gekoppeltem
atomique avec plasma induit par haute fréquence (ICP- Plasma (ICP-AES) nach Königswasseraufschluss
AES) après digestion á l'eau régale
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 260.

This draft amendment A1, if approved, will modify the European Standard EN 16317:2013. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16317:2013/prA1:2015 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 16317:2013/oprA1:2015
EN 16317:2013/prA1:2015 (E)
Contents
Page
Foreword .3
1 Modification to the Title .4
2 Modifications to Clause 1, Scope .4
3 Modification to Clause 2, Normative references .4
4 Modification to Clause 3, Terms and definitions .4
5 Modification to Clause 10, Precision, Table 2 .4
6 Modification to A.1, Inter-laboratory tests .5
7 Modification to A.2, Statistical results for the determination of arsenic by ICP-AES .5


2

---------------------- Page: 4 ----------------------

SIST EN 16317:2013/oprA1:2015
EN
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.