ENV 1363-3:1998
(Main)Fire resistance tests - Part 3: Verification of furnace performance
- BACK
- 15-Dec-1998
- 31-May-2022
- 13.220.50
- 305/2011
- 89/106/EEC
- CEN/TC 127
Fire resistance tests - Part 3: Verification of furnace performance
This European Prestandard describes a procedure for the verification of the thermal and pressure characteristics of fire resistance furnaces for the testing of separating elements. The procedure is to be carried out on new furnaces, when the furnace is relined (replacement of > 30 % of the lining), when the furnace is overhauled or every two years, whichever occurs first. Information on additional measurements is given in annex A.
Feuerwiderstandsprüfungen - Teil 3: Nachweis der Ofenleistung
Preskusi požarne odpornosti – 3. del: Preverjanje lastnosti peči
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-1999
3UHVNXVLSRåDUQHRGSRUQRVWL±GHO3UHYHUMDQMHODVWQRVWLSHþL
Fire resistance tests - Part 3: Verification of furnace performance
Feuerwiderstandsprüfungen - Teil 3: Nachweis der Ofenleistung
Ta slovenski standard je istoveten z: ENV 1363-3:1998
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This document covers single and double leaf, hinged and pivoted, steel based doorsets except steel doorsets with metal framed door leaves covered by EN 15269-5. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
- integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
- door leaf;
- side panels, transom panels, flush overpanels;
- air transfer grilles (e.g. ventilation grilles/louvres);
- components (e.g. frame/suspension system) fixed to the supporting construction (e.g. wall/ceiling);
- glazing within the doorset (e.g. for door leaf, side, transom and flush overpanels);
- items of building hardware;
- decorative and protective finishes;
- intumescent seals, strips and non-intumescent (smoke, draught or acoustic) seals;
- alternative supporting construction(s).
This document does not cover horizontally installed doorsets (e.g. traps).
The effect on the classification ‘C’ for the doorsets following an extended application process is not addressed in this document.
- Draft139 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Oct-2024
- 13.220.50
- 91.060.50
- 305/2011
- M/117
- CEN/TC 127
This document specifies a test method for determining the fire resistance of smoke extraction ducts. It is applicable only to smoke extraction ducts that pass through another fire compartment apart from the compartment from where smoke needs to be extracted in case of fire. It represents fire exposure of a fully developed fire.
This method of test is only applicable to fire resistant ventilation ducts (same construction) with the following classification according to EN 13501-3:
- fire from inside and outside i ↔ o;
- applicable to a pressure difference up to 500 Pa in fire conditions;
NOTE 1 It is assumed that the duct A test(s) in accordance with EN 1366-1 has been performed with an under-pressure of minimum 500 Pa.
- with integrity (E) and insulation (I) criteria equal to or higher than the intended classification for the smoke extraction duct.
For the purposes of the test described in this document, the duct is referred to as duct C.
This test method has been designed to cover both vertical and horizontal smoke extraction ducts. A vertical system need not be evaluated to this method provided that:
- both horizontal (ho) and vertical (ve) classification according to EN 13501-3 has been obtained for the ventilation duct;
- it has been tested in a horizontal orientation to this method.
If the ventilation duct in practise is only used for vertical applications in smoke extraction systems, only vertical (ve) classification is obtained in accordance with EN 13501-3 and tested only in a vertical orientation to this test method.
This test method is suitable for ducts constructed from non-combustible materials (class A1 and A2-s1, d0 according to EN 13501-1).
NOTE 2 Reaction with components of the duct can affect the oxygen concentration inside the duct leading to inaccurate calculation of the leakage rate. If it is determined this has happened refer to Annex D.
This document applies to four sided rectangular and circular ducts only (with fire exposure on all sides). Ducts that utilize elements of construction for one, two or three sides are not covered. An alternative test method for one, two and three sided ducts will be developed separately.
- Standard58 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Oct-2024
- 13.220.20
- 13.220.50
- 305/2011
- M/117
- CEN/TC 127
This part of EN 1366 specifies a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only. In such applications, the smoke extraction system is only intended to function up to flashover (typically 600 °C).
This method of test is only suitable for ducts constructed from non-combustible materials (class A1 and A2-s1, d0 according to EN 13501-1).
It is applicable only to four sided and circular ducts. One-, two- and three-sided ducts are not covered. This document is applicable only for the standard sizes or smaller as described.
This test method of part 9 is applicable only to smoke extraction ducts that do not pass into other fire compartments. For smoke extraction ducts that pass into other compartments, the method of test described in EN 1366-8 is used.
The smoke extraction duct is part of the smoke extraction system which also includes smoke control dampers and smoke extract fans.
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Oct-2024
- 13.220.50
- 91.140.30
- 305/2011
- M/117
- CEN/TC 127
This document specifies test methods for smoke control dampers to assess their performance under elevated temperature or fire conditions, as well as at ambient temperatures.
Smoke control damper tests are used to confirm that the furnace testing requirements of EN 12101-8 are met and EN 12101-8 is for consideration before carrying out these tests.
Smoke control dampers tested to this document are expected to be classified using EN 13501-4 and this document is expected to be considered before carrying out these tests.
NOTE Some smoke control dampers to be tested might require testing following the information given in EN 1366-2 and this needs consideration before carrying out testing.
This document is expected to be read in conjunction with EN 12101-8, EN 13501-4, EN 1366-2 and EN 1363-1, the latter giving further details for fire resistance testing.
For installation details, the requirements for smoke extraction ducts are for consideration and these are defined in EN 1366-8 and EN 1366-9.
- Standard99 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Sep-2024
- 13.220.50
- 91.140.30
- 305/2011
- M/117
- CEN/TC 127
This document specifies the procedure for classification of construction products and building elements using data from fire resistance and/or smoke leakage/control tests and/or mechanical tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this document.
This document deals with:
a) loadbearing elements without a fire separating function:
- walls;
- floors;
- roofs;
- beams;
- columns;
- balconies;
- walkways;
- stairs.
b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures:
- walls;
- floors;
- roofs;
- raised floors.
c) products and systems for protecting elements or parts of the works:
- ceilings with no independent fire resistance;
- fire protective coatings, claddings and screens;
d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures:
- partitions;
- facades (curtain walls) and external walls;
- ceilings with independent fire resistance;
- raised floors;
- fire resisting doorsets, shutter assemblies and openable windows and their closing devices;
- smoke control doorsets and shutter assemblies and their closing devices;
- conveyor systems and their closures;
- penetration seals;
- linear joint seals;
- combined penetration seals;
- service ducts and shafts;
- air transfer grilles.
- chimneys.
e) wall and ceiling coverings with fire protection ability.
f) lift landing doors which are tested according to EN 81-58 are excluded from this document. Lift landing doors which are tested in accordance with EN 1634-1 are classified in accordance with 7.5.5.
Relevant test methods which have been prepared for these construction products are listed in Clauses 2 and 7.
- Standard86 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2023
- 13.220.50
- 305/2011
- M/117
- CEN/TC 127
This document gives the procedures for preparing standards and reports following the extended application (EXAP) process using the results of reaction to fire tests, fire resistance tests (including other performance characteristics e.g. smoke leakage/control and/or durability of self-closing), and external fire exposure to roof tests undertaken for fire classification of products and product families in accordance with the various parts of EN 13501. EXAP rules limit the number of tests required by implementing methods to determine the fire classification of a range of products (e.g. range of product, larger dimensions etc.) and EXAP rules form a standardized technical agreement on the parameter changes.
The fundamental concept of EXAP is the development of safe methods that provide extensions to the scope of the tested product while maintaining the required classification for the product. Test reports constitute the basis of an EXAP report.
This document makes reference to ‘extended application standards’ throughout; wherever this term is used it refers to either a standard prepared by CEN/TC 127 ‘Fire safety in buildings’ or the relevant product standard which includes information on extended application.
The European system currently permits extended application rules to be included in technical specifications. CEN Technical Committees and EOTA Working groups producing these rules are asked to seek the guidance of CEN/TC 127 to ensure that their rules comply with standards prepared by CEN/TC 127. In cases where extended application rules in harmonized EN product standards and ETAs do not comply with standards prepared by CEN/TC 127 the CEN BT are informed.
This document does not cover the incorporation of the product into the construction works that is justified by national rules.
Expert judgements (i.e. an opinion that is not considered/covered by an EXAP standard and only based on the experience of one individual) do not form part of this process.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 21-Mar-2023
- 13.220.50
- 305/2011
- M/117
- CEN/TC 127
This document is applicable to single and double leaf, hinged and pivoted doorsets with timber-based leaves or timber framed glazed door leaves, covered by EN 15269-3 and / or EN 15269-20.
This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 1191 and or EN 12605:2000, as appropriate.
Subject to the completion of the appropriate self-closing test(s), the extended application can cover all or some of the following examples:
- door leaf; pass doors;
- glazed doorsets including vision panels and framed glazed doorsets;
- side, transom and/or overpanels;
- ventilation grilles and/or louvres;
- wall or ceiling fixed elements (door frame/suspension system);
- glazing for door leaf, side, transom and flush over panels;
- items of building hardware;
- decorative finishes;
- intumescent, strips, smoke, draught or acoustic seals;
- alternative supporting construction(s).
- Standard78 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Mar-2023
- 13.220.50
- 91.060.50
- CEN/TC 127
This document provides the reaction to fire classification procedure for electric cables.
NOTE For the purpose of this document, the term "electric cables" covers all power, control and communication cables, including optical fibre cables.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Dec-2022
- 13.220.50
- 29.060.20
- 305/2011
- M/117
- CEN/TC 127
This document covers steel rolling shutters as covered by EN 15269 10 or EN 15269 20.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 16034.
Subject to the completion of the appropriate self-closing test or tests, the extended application could cover all or some of the following non-exhaustive list:
— shutter curtain;
— wall/ceiling fixed elements (frame/suspension system);
— decorative finishes;
— intumescent, smoke, draught or acoustic seals;
— alternative supporting construction(s).
- Standard73 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Dec-2022
- 13.220.50
- 91.060.50
- 305/2011
- M/117
- CEN/TC 127
This document is applicable to the following types of steel based doorsets: horizontally sliding single and double leaf doorsets, horizontally sliding single and double leaf telescopic doorsets, vertically sliding single leaf doorsets and vertically sliding single leaf telescopic doorsets as covered by EN 15269-7 or EN 15269-20.
This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 12605:2000 and/or EN 1191.
Subject to the completion of the appropriate durability of self-closing test or tests, the extended application can cover all or some of the following non-exhaustive list:
- door leaf (of the sliding doorset and its pass door);
- integrated pass doors;
- wall or ceiling fixed parts or items of the doorset, e.g. frame or suspension systems;
- ventilation grilles and/or louvres;
- glazing for door leaf;
- items of building hardware;
- decorative finishes;
- intumescent, smoke, draught or acoustic seals;
- alternative supporting construction(s).
- Standard60 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Dec-2022
- 13.220.50
- 91.060.50
- 305/2011
- M/117
- CEN/TC 127
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.