Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads

EN 50525-2-12 applies to thermoplastic (PVC) insulated and PVC sheathed extensible leads. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for the connection of domestic appliances to the fixed supply. Circular cables and flat cables are included. The maximum conductor operating temperature for each of the cables in this standard is 70 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-12 should be read in conjunction with EN 50525-1, which specifies general requirements.

Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (Uo/U) - Teil 2-12: Starkstromleitungen für allgemeine Anwendungen - Wendelleitungen mit thermoplastischer PVC-Isolierung

Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (Uo/U) - Partie 2-12: Câbles pour applications générales - Câbles isolés en PVC thermoplastique pour cordons extensibles

Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V (Uo/U) - 2-12. del: Kabli za splošno uporabo - Raztegljivi priključni vodi s termoplastično PVC izolacijo

EN 50525-2-12 velja za raztegljive priključne vode s termoplastično (PVC) izolacijo in plaščem PVC. Ti kabli imajo nazivno napetost do in vključno 300/500 V (UO/U). Namenjeni so povezavi gospodinjskih aparatov s fiksnim napajanem. Vključeni so okrogli in ravni kabli. Maksimalna delovna temperatura pretvornika za vsakega od kablov iz tega standarda je 70 °C

General Information

Status
Published
Publication Date
05-May-2011
Withdrawal Date
16-Jan-2014
Technical Committee
Drafting Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
23-Oct-2024
Completion Date
23-Sep-2025

Relations

Overview

EN 50525-2-12:2011 is a CENELEC part standard in the EN 50525 series for low voltage energy cables. While the series title covers rated voltages up to 450/750 V (U0/U), this Part specifically applies to thermoplastic (PVC) insulated and PVC sheathed extensible leads rated up to and including 300/500 V (U0/U). It covers both circular and flat extensible leads intended primarily for the connection of domestic appliances to the fixed supply. Maximum conductor operating temperature is 70 °C. The standard should be read with EN 50525-1 (general requirements) and is intended to ensure safe, traceable and mechanically reliable extensible leads (coiled/helical cables).

Key topics and requirements

  • Cable types and codes: Defines CENELEC codes for light and ordinary duty extensible leads:
    • Light duty: H03VVH8-F, H03VVH2H8-F
    • Ordinary duty: H05VVH8-F, H05VVH2H8-F
  • Construction details:
    • Conductors: Class 5 flexible conductors per EN 60228.
    • Insulation: PVC compound Type TI 2 (EN 50363-3).
    • Sheath: PVC compound Type TM 2 (EN 50363-4-1).
    • Specified conductor sizes for circular and flat designs (e.g., 0.5 mm², 0.75 mm², 1.0 mm², 1.5 mm²).
    • Pre-coiling and post-coiling construction and marking rules, including additional coiler identification (Annex A).
  • Dimensional and electrical limits:
    • Specified insulation and sheath thicknesses and minimum insulation resistance at 70 °C (see Annex D tables).
    • Voltage and insulation resistance tests on cores and completed cables.
  • Testing and performance:
    • Pre-coiling and post-coiling test regimes (electrical, dimensional, material, mechanical).
    • Mechanical tests for extensible leads: extension and endurance tests (Annex F).
    • Compatibility, ageing and impact tests (e.g., ageing at 80 °C for compatibility; impact at −5 °C).
  • Traceability and marking: Post-coiling marking requirements to identify the coiler and maintain traceability.

Applications and who uses it

  • Intended users:
    • Cable and extensible lead manufacturers
    • Appliance OEMs specifying connection leads
    • Test laboratories and certification bodies
    • Procurement and compliance teams in electrical equipment firms
  • Typical applications:
    • Coiled extension leads for domestic appliances (irons, small kitchen appliances, etc.)
    • Flexible leads where retractable/helical form is required for user convenience and strain reduction
  • Benefits:
    • Ensures safe low-voltage connections, mechanical durability for repeated extension, and material compatibility for long-term use.

Related standards

  • EN 50525-1 - General requirements for low voltage energy cables
  • EN 50363-3 / EN 50363-4-1 - PVC insulating and sheathing compound specifications
  • EN 60228 - Conductors of insulated cables
  • EN 50395, EN 50396 - Electrical and non-electrical test methods
  • EN 60811‑1‑2, EN 60811‑1‑4 - Common material testing methods
  • HD 516 - Guidance on safe use of cables

Keywords: EN 50525-2-12, extensible leads, PVC insulated extensible leads, low voltage energy cables, H03VVH8-F, H05VVH8-F, helical coiled cable, cable testing, domestic appliance leads.

Standard
EN 50525-2-12:2011
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (Uo/U) - Teil 2-12: Starkstromleitungen für allgemeine Anwendungen - Wendelleitungen mit thermoplastischer PVCIsolierungCâbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (Uo/U) - Partie 2-12: Câbles pour applications générales - Câbles isolés en PVC thermoplastique pour cordons extensiblesElectric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 50525-2-12:2011SIST EN 50525-2-12:2011en01-julij-2011SIST EN 50525-2-12:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 50525-2-12 NORME EUROPÉENNE
EUROPÄISCHE NORM May 2011
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-12:2011 E
ICS 29.060.20 Supersedes HD 21.10 S2:2001
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) -
Part 2-12: Cables for general applications -
Cables with thermoplastic PVC insulation for extensible leads
Câbles électriques -
Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) -
Partie 2-12: Câbles pour applications générales -
Câbles isolés en PVC thermoplastique pour cordons extensibles
Kabel und Leitungen -
Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-12: Starkstromleitungen für allgemeine Anwendungen -
Wendelleitungen mit thermoplastischer PVC-Isolierung
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
Foreword This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-2-12 on 2011-01-17. This document, which is one of a multipart series, supersedes HD 21.10 S2:2001. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2012-01-17 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2014-01-17 ___________ SIST EN 50525-2-12:2011

- 3 - EN 50525-2-12:2011
Contents Page 1Scope . 42Normative references . 43Terms and definitions . 44General purpose cables . 54.1Light duty cables – H03VVH8-F and H03VVH2H8-F . 54.2Ordinary duty cables – H05VVH8-F and H05VVH2H8-F . 6Annex A (normative)
Post-coiling requirements for marking . 8Annex B (normative)
Pre-coiling tests for cables to EN 50525-2-12 . 9Annex C (normative)
Post-coiling tests for cables to EN 50525-2-12 . 10Annex D (normative)
General data . 11Annex E (normative)
Requirements for compatibility test . 13E.1Test conditions . 13E.2Requirements . 13Annex F (normative)
Requirements for mechanical tests . 14F.1Extension tests for extensible leads . 14F.2Endurance test for extensible leads . 14Bibliography . 15 Tables Table B.1 . 9Table C.1 . 10Table D.1 – Cables rated at 300/300 V . 11Table D.2 – Cables rated at 300/500 V . 12Table E.1 . 13 SIST EN 50525-2-12:2011

1 Scope EN 50525-2-12 applies to thermoplastic (PVC) insulated and PVC sheathed extensible leads.
The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for the connection of domestic appliances to the fixed supply. Circular cables and flat cables are included. The maximum conductor operating temperature for each of the cables in this standard is 70 °C. NOTEHD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-12 should be read in conjunction with EN 50525-1, which specifies general requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTEOne or more references to the standards below are in respect of a specific sub-division of that standard, for instance a clause, a table, a class or a type. Cross-references to these standards are undated and, at all times, the latest version applies. EN 50363-3
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds EN 50363-4-1
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds EN 50395
Electrical test methods for low voltage energy cables EN 50396
Non electrical test methods for low voltage energy cables EN 50525-1
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements EN 60228
Conductors of insulated cables (IEC 60228) EN 60811-1-2
Insulating and sheathing materials of electric
and optical cables - Common test methods - Part 1-2: General application - Thermal ageing methods (IEC 60811-1-2) EN 60811-1-4
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature (IEC 60811-1-4) 3 Terms and definitions For the purposes of this document the terms and definitions given in Clause 3 of EN 50525-1 apply. SIST EN 50525-2-12:2011

- 5 - EN 50525-2-12:2011
4 General purpose cables 4.1 Light duty cables – H03VVH8-F and H03VVH2H8-F 4.1.1 Construction – Pre-coiling 4.1.1.1 Conductor The conductor shall be class 5, according to EN 60228. 4.1.1.2 Sizes of cable The sizes of cable shall be: – circular cables – 0,5 mm2 and 0,75 mm2 – 2 and 3 core; – flat cables – 0,5 mm2 and 0,75 mm2 – 2 core only. 4.1.1.3 Insulation The insulation shall be polyvinyl chloride compound of Type TI 2 to EN 50363-3. 4.1.1.4 Assembly The cables shall be assembled as follows: – circular cable: the cores shall be twisted together; – flat cable:
the cores shall be laid parallel. NOTE A tape may be applied around the core assembly before application of the sheath. 4.1.1.5 Sheath The sheath shall be polyvinyl chloride compound of Type TM 2 to EN 50363-4-1. The sheath shall fill the spaces between the cores, thus forming a filling. 4.1.1.6 Marking The cable shall be marked with the CENELEC code H03VVH8-F for circular cables, or H03VVH2H8-F for flat cables. The marking shall comply with Clause 6 of EN 50525-1. 4.1.2 Construction – Post-coiling The cables shall be coiled in the form of a helical lead and caused substantially to maintain this form during use. Slight deformation of the cables, created by the coil forming process, is acceptable provided t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 50525-2-12:2011 is a standard published by CLC. Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads". This standard covers: EN 50525-2-12 applies to thermoplastic (PVC) insulated and PVC sheathed extensible leads. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for the connection of domestic appliances to the fixed supply. Circular cables and flat cables are included. The maximum conductor operating temperature for each of the cables in this standard is 70 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-12 should be read in conjunction with EN 50525-1, which specifies general requirements.

EN 50525-2-12 applies to thermoplastic (PVC) insulated and PVC sheathed extensible leads. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for the connection of domestic appliances to the fixed supply. Circular cables and flat cables are included. The maximum conductor operating temperature for each of the cables in this standard is 70 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-12 should be read in conjunction with EN 50525-1, which specifies general requirements.

EN 50525-2-12:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50525-2-12:2011 has the following relationships with other standards: It is inter standard links to HD 21.10 S2:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50525-2-12:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 2014/53/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 50525-2-12:2011 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.