Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 216: Heat-shrinkable, flame-retarded, limited-fire hazard sleeving

Gives the requirements for four types of heat-shrinkable, flame- retarded, limited-fire-hazard sleeving with a thermal endurance rating of 105 °C as shown below: Class A: thin wall, shrink ratio 2:1, internal diameter up to 102,0 mm Class B: medium wall, shrink ratio 2:1, internal diameter up to 60,0 mm Class C: thick wall, shrink ratio 2:1, internal diameter up to 51,0 mm Class D: medium wall, shrink ratio 3:1, internal diameter up to 40,0 mm Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.

Isolierschläuche - Teil 3: Anforderungen für einzelne Schlauchtypen - Blatt 216: Wärmeschrumpfende, flammhemmende Schläuche mit begrenztem Brandrisiko

Gaines isolantes souples - Partie 3: Spécifications pour types particuliers de gaines - Feuille 216: Gaines thermorétractables, retardées à la flamme, au risque de feu limité

Donne les prescriptions relatives à quatre types de gaines thermorétractables, retardées à la flamme, au risque de feu limité, ayant un indice de température de 105 °C, comme cela est indiqué ci-dessous. Classe A: paroi mince, rapport de rétreint 2:1, diamètre intérieur allant jusqu'à 102,0 mm Classe B: paroi moyenne, rapport de rétreint 2:1, diamètre intérieur allant jusqu'à 60,0 mm Classe C paroi épaisse, rapport de rétreint 2:1, diamètre intérieur allant jusqu'à 51,0 mm Classe D: paroi moyenne, rapport de rétreint 3:1, diamètre intérieur allant jusqu'à 40,0 mm Les matériaux qui sont conformes à cette spécification satisfont à des niveaux de performances établis. Cependant, il convient que le choix d'un matériau par un utilisateur et pour une application particulière soit fondé sur les prescriptions réelles nécessaires pour obtenir les performances satisfaisantes pour cette application, et non sur cette seule spécification.

Gibke izolacijske cevi – 3. del: Specifikacije za posamezne tipe cevi – 216. list: Toplotno skrčljive, ognjevarne cevi z majhno požarno nevarnostjo (IEC 60684-3-216:2001 + popravek 2003 + A1:2005)

General Information

Status
Withdrawn
Publication Date
30-Jun-2005
Withdrawal Date
31-Mar-2008
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
12-Sep-2022
Completion Date
12-Sep-2022

Relations

Buy Standard

Standard
EN 60684-3-216:2006
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 60684-3-216:2006
STANDARD
januar 2006
Gibke izolacijske cevi – 3. del: Specifikacije za posamezne tipe cevi – 216.
list: Toplotno skrčljive, ognjevarne cevi z majhno požarno nevarnostjo (IEC
60684-3-216:2001 + popravek 2003 + A1:2005)
(istoveten EN 60684-3-216:2005)

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving -

Sheet 216: Heat-shrinkable, flame-retarded, limited fire hazard sleeving (IEC
60684-3-216:2001 + Corrigendum 2003 + A1:2005)
ICS 29.035.20 Referenčna številka
SIST EN 60684-3-216:2006(en)

© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 60684-3-216
NORME EUROPÉENNE
EUROPÄISCHE NORM July 2005
ICS 29.035.20
English version
Flexible insulating sleeving
Part 3: Specifications for individual types of sleeving
Sheet 216: Heat-shrinkable, flame-retarded,
limited-fire hazard sleeving
(IEC 60684-3-216:2001 + corrigendum 2003 + A1:2005)
Gaines isolantes souples Isolierschläuche
Partie 3: Spécifications pour types Teil 3: Anforderungen für einzelne
particuliers de gaines Schlauchtypen
Feuille 216: Gaines thermorétractables, Blatt 216: Wärmeschrumpfende,
retardées à la flamme, au risque flammwidrige Schläuche mit begrenztem
de feu limité Brandrisiko
(CEI 60684-3-216:2001 + (IEC 60684-3-216:2001 +
corrigendum 2003 + A1:2005) Corrigendum 2003 + A1:2005)

This European Standard was approved by CENELEC on 2005-04-12. CENELEC members are bound to

comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European

Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CENELEC member into its own language and

notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech

Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,

Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60684-3-216:2005 E
---------------------- Page: 2 ----------------------
EN 60684-3-216:2005 - 2 -
Foreword

The texts of documents 15C/1140/FDIS and 15C/1664/FDIS, future edition 1 of IEC 60684-3-216 and

its amendment 1, prepared by SC 15C, Specifications, of IEC TC 15, Insulating materials, were

submitted to the IEC-CENELEC parallel vote and were approved by CENELEC as EN 60684-3-216 on

2005-04-12.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-02-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-04-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice

The text of the International Standard IEC 60684-3-216:2001 + corrigendum 1:2003 + A1:2005 was

approved by CENELEC as a European Standard without any modification.
__________
---------------------- Page: 3 ----------------------
- 3 - EN 60684-3-216:2005
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

NOTE Where an international publication has been modified by common modifications, indicated by (mod), the relevant

EN/HD applies.
Publication Year Title EN/HD Year
IEC 60684-1 1980 Specification for flexible insulating EN 60684-1 1995
sleeving
Part 1: Definitions and general
requirements
IEC 60684-2 1997 Part 2: Methods of test EN 60684-2 1997
IEC 60757 1983 Code for designation of colours HD 457 S1 1985
ISO 846 1997 Plastics - Evaluation of the action of EN ISO 846 1997
microorganisms
ISO 1817 1999 Rubber, vulcanized - Determination of the - -
effect of liquids

EN 60684-1 is superseded by EN 60684-1:2003, which is based on IEC 60684-1:2003.

---------------------- Page: 4 ----------------------
NORME CEI
INTERNATIONALE IEC
60684-3-216
INTERNATIONAL
Edition 1.1
STANDARD
2005-03
Edition 1:2001 consolidée par l'amendement 1:2005
Edition 1:2001 consolidated with amendment 1:2005
Gaines isolantes souples –
Partie 3:
Spécifications pour types particuliers
de gaines –
Feuille 216: Gaines thermorétractables,
retardées à la flamme, au risque de feu limité
Flexible insulating sleeving –
Part 3:
Specifications for individual types of sleeving –
Sheet 216: Heat-shrinkable, flame-retarded,
limited-fire-harzard sleeving
 IEC 2005 Droits de reproduction réservés  Copyright - all rights reserved

Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any

utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including

électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from

microfilms, sans l'accord écrit de l'éditeur. the publisher.

International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland

Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

CODE PRIX
Commission Electrotechnique Internationale CB
PRICE CODE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 5 ----------------------
60684-3-216 © IEC:2001+A1:2005 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FLEXIBLE INSULATING SLEEVING –
Part 3: Specifications for individual types of sleeving –
Sheet 216: Heat-shrinkable, flame-retarded,
limited-fire-hazard sleeving
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

the latter.

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any

equipment declared to be in conformity with an IEC Publication.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 60684-3-216 has been prepared by subcommittee 15C: Specifi-

cations, of IEC technical committee 15: Insulating materials.

This consolidated version of IEC 60684-3-216 consists of the first edition (2001) [documents

15C/1140/FDIS and 15C/1164/RVD], its amendment 1 (2005) [documents 15C/1664/FDIS and

15C/1676/RVD] and its corrigendum of February 2003.

The technical content is therefore identical to the base edition and its amendment and has

been prepared for user convenience.
It bears the edition number 1.1.

A vertical line in the margin shows where the base publication has been modified by

amendment 1.
---------------------- Page: 6 ----------------------
60684-3-216  IEC:2001+A1:2005 – 5 –

The committee has decided that the contents of this publication will remain unchanged until

the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in

the data related to the specific publication. At this date, the publication will be

• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 7 ----------------------
60684-3-216  IEC:2001+A1:2005 – 7 –
INTRODUCTION

This International Standard is one of a series which deals with flexible insulating sleeving for

electrical purposes.
The series consists of three parts:
Part 1: Definitions and general requirements (IEC 60684-1);
Part 2: Methods of test (IEC 60684-2);
Part 3: Specifications for individual types of sleeving (IEC 60684-3).
This standard is one of the sheets comprising Part 3.
---------------------- Page: 8 ----------------------
60684-3-216  IEC:2001+A1:2005 – 9 –
FLEXIBLE INSULATING SLEEVING –
Part 3: Specifications for individual types of sleeving –
Sheet 216: Heat-shrinkable, flame-retarded,
limited-fire-hazard sleeving
1 Scope

This sheet of IEC 60684-3 gives the requirements for four types of heat-shrinkable, flame-

retarded, limited-fire-hazard sleeving with a thermal endurance rating of 105 °C as shown

below:
Class A: thin wall shrink ratio 2:1 internal diameter up to 102,0 mm
Class B: medium wall shrink ratio 2:1 internal diameter up to 60,0 mm
Class C: thick wall shrink ratio 2:1 internal diameter up to 51,0 mm
Class D: medium wall shrink ratio 3:1 internal diameter up to 40,0 mm

These sleevings are normally supplied in the following colours: black, red, green, blue, white,

yellow and green/yellow.

Sizes or colours other than those listed in this standard may be available as custom items.