EN 50440:2015/A2:2026
(Amendment)Efficiency of domestic electrical storage water heaters and testing methods
- Abstract
This European Standard specifies methods for measuring the performance of electric storage water heaters for the production of sanitary hot water for household and similar use. The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics. NOTE 1 This standard does not apply to; − storage water heaters that use electricity as a secondary source of heating the water; − storage water heaters that do not use a tank to store hot water; − electric storage water heaters that do not meet the minimum (or maximum) output performance of the smallest (or biggest) load profile, as defined in Table 4. NOTE 2 This standard does not specify performance or safety requirements. For safety requirements see EN 60335-1:2020 in conjunction with EN 60335-2-21:2023
- Status
- Published
- Publication Date
- 08-Oct-2026
- Technical Committee
- CLC/TC 59X - Performance of household and similar electrical appliances
- Drafting Committee
- CLC/TC 59X/WG 04 - Water heaters
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 09-Oct-2026
- Due Date
- 28-Jan-2027
- Completion Date
- 28-Jan-2027
EN 50440:2015/A2:2026 is a CLC amendment to EN 50440:2015 for domestic electric storage water heaters. It updates the methods used to measure performance, verify declared load profiles, and calculate efficiency and annual electricity consumption for household and similar sanitary hot water use. It is aimed at manufacturers, test laboratories, certification bodies, and buyers who need a common basis for comparing declared performance.
What does EN 50440:2015/A2:2026 specify?
EN 50440:2015/A2:2026 modifies the European Standard for measuring the performance of electric storage water heaters. The amendment is read together with EN 50440:2015 and focuses on how the water heater is tested, how the load profile is checked, and what data are reported.
It covers these parts of the document:
| Part | What it covers |
|---|---|
| Clause 1 | Scope |
| Clause 3 | Terms and definitions |
| Clause 4 | Symbols and units |
| Clause 7 | General conditions for measurements |
| Clause 8 | General test conditions |
| Clause 9 | Test procedures |
| Clause 10 | Data report |
| Annex A | Calculation of the specific energy efficiency and annual consumption of electric energy |
| Bibliography | Reference update |
The scope still excludes storage water heaters that use electricity only as a secondary heating source, water heaters without a tank, and heaters outside the smallest or biggest load profile limits. The document also states that it does not set performance or safety requirements, and points safety readers to EN IEC 60335-1 with EN IEC 60335-2-21.
What are the key requirements of EN 50440:2015/A2:2026?
The amendment mainly tightens how declared performance is checked and how the test results are turned into reported values.
Clause 7 updates measurement conditions and tolerances. It sets the test conditions for time, sanitary water temperature, pressure, ambient air temperature, and measurement uncertainty. In practice, this tells the lab how closely the test rig must control the water and air conditions so results can be compared across products.
Clause 8 introduces a structured load-profile verification. The declared load profile is checked against the maximum load profile, or the next lower one, using the measured heat-up energy and the operating-point tables. In practice, the manufacturer must declare a profile the product can actually meet under the defined draw-off pattern.
Clause 8 separates energized storage water heater and off-peak storage water heater checks. For energized storage water heater, the largest load profile is the one where all stated conditions are met. For off-peak storage water heater, the declared load profile is assumed to be M or higher and is verified with two energy-based conditions. This matters because the two product types are judged with different assumptions.
Clause 8 and Table 6 define the operating points used for verification. The tables link reference energy, maximum draw-off, equivalent 40 °C water, and the temperature criterion after the largest one-hour-and-half sum of draw-offs. In practice, the test laboratory uses these values to decide which load profile is justified.
Clause 9 adds the rated heat output. Rated heat output is defined from electrical energy efficiency and nominal power input, and the electricity consumption during the heat-up period is measured in STEP 2. This gives a consistent reported output value for comparison.
Clause 9 adds a default sound power level for units without moving parts. A value of 15 dB is set for electric storage water heaters without moving parts such as a pump. This gives report users a default acoustic value where no moving parts are present.
Clause 10 expands the data report. The report now includes rated heat output. In practice, this makes the declared technical data more complete for procurement and conformity documentation.
Annex A updates the efficiency and annual-consumption calculation. The amendment adjusts the notation and the electricity conversion coefficient. This affects the final efficiency figures and annual energy calculations used in documentation.
What terms does EN 50440:2015/A2:2026 define?
- Rated heat output (P) - The heat output of the water heater under standard rating conditions, expressed in kW.
- Electricity consumption during the heat-up period (Qheat-up) - The electricity used during STEP 2 of the test, which is used as the energy basis for several calculations.
- Nominal power input (Pnom) - The power input assigned to the appliance by the manufacturer and used in the rated heat output formula.
- Rated capacity (C) - The manufacturer-assigned capacity of the water heater, used in load-profile verification.
- Declared load profile (LPdec) - The load profile claimed by the manufacturer and checked against the test results.
- Maximum load profile (LPmax) - The largest load profile the product can meet under the stated verification rules.
- Equivalent energy of the minimum quantity of water delivered at 40 °C (Qequiv40) - The energy equivalent used to check whether the heater can deliver the required usable hot water.
Who uses EN 50440:2015/A2:2026?
EN 50440:2015/A2:2026 is used by manufacturers of domestic electric storage water heaters, test laboratories, certification bodies, and technical teams that prepare product declarations. It is also useful for quality managers, specifiers, and buyers who need to compare reported efficiency, load profile, and annual consumption on a common test basis.
What changed in EN 50440:2015/A2:2026 from the previous edition?
This amendment updates EN 50440:2015 by revising the scope note for safety references, adding the term rated heat output, expanding symbols and units, tightening test conditions, and replacing the general test conditions section with load-profile verification rules. It also adds the rated heat output calculation, a default sound power level for units without moving parts, a new data-report item, revised Annex A calculations, and an updated bibliography reference to EN IEC 60335-2-21.
Which standards are used with EN 50440:2015/A2:2026?
- EN IEC 60335-1 - gives the general safety requirements for household and similar electrical appliances.
- EN IEC 60335-2-21 - gives the particular safety requirements for storage water heaters and is the companion safety standard named alongside EN IEC 60335-1.
What does the EN 50440:2015/A2:2026 document contain?
The document contains updated tables for measurement conditions, test tolerances, load-profile schedules, operating points, and data reporting. It also contains formulas for load-profile verification, rated heat output, and the calculation of specific energy efficiency and annual consumption. These methods are used in testing, conformity assessment, and product documentation so that the declared performance can be checked in a repeatable way.
Relations
- Effective Date
- 13-Aug-2024
Get Certified
Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 50440:2015/A2:2026 is a amendment published by CLC. Its full title is "Efficiency of domestic electrical storage water heaters and testing methods". This standard covers: This European Standard specifies methods for measuring the performance of electric storage water heaters for the production of sanitary hot water for household and similar use. The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics. NOTE 1 This standard does not apply to; − storage water heaters that use electricity as a secondary source of heating the water; − storage water heaters that do not use a tank to store hot water; − electric storage water heaters that do not meet the minimum (or maximum) output performance of the smallest (or biggest) load profile, as defined in Table 4. NOTE 2 This standard does not specify performance or safety requirements. For safety requirements see EN 60335-1:2020 in conjunction with EN 60335-2-21:2023
This European Standard specifies methods for measuring the performance of electric storage water heaters for the production of sanitary hot water for household and similar use. The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics. NOTE 1 This standard does not apply to; − storage water heaters that use electricity as a secondary source of heating the water; − storage water heaters that do not use a tank to store hot water; − electric storage water heaters that do not meet the minimum (or maximum) output performance of the smallest (or biggest) load profile, as defined in Table 4. NOTE 2 This standard does not specify performance or safety requirements. For safety requirements see EN 60335-1:2020 in conjunction with EN 60335-2-21:2023
EN 50440:2015/A2:2026 is classified under the following ICS (International Classification for Standards) categories: 91.140.65 - Water heating equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50440:2015/A2:2026 has the following relationships with other standards: It is inter standard links to EN 50440:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50440:2015/A2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- European foreword
- 1 Modification to Clause 1, Scope
- 2 Modification to Clause 3, “Terms and definitions”
- 3 Modification to Clause 4, “Symbols and Units”
- 4 Modification to Clause 7, “General conditions for measurements”
- 5 Modification to Clause 8, “Reference conditions”
- 8.1 Load profile
- 8.2 Verification of the declared load profile
- 6 Modification to Clause 9, “Test procedures”
- 9.3 Sound Power Level
- 7 Modification to Clause 10, Data Report
- 12 Rated heat output, in kW (P ) N,N
- 8 Modification to Annex A, “Calculation of the specific energy efficiency and of the
- 9 Modification to the Bibliography
European foreword
This document (EN 50440:2015/A2:2026) has been prepared by CLC/TC 59X “Performance of household and similar electrical appliances”.
The following dates are fixed:
- latest date by which this document has to be (dop) 2027-10-31 implemented at national level by publication of an identical national standard or by endorsement
- latest date by which the national standards (dow) 2029-10-31 conflicting with this document have to be withdrawn Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. This document is read in conjunction with EN 50440:2015.
Any feedback and questions on this document should be directed to the users’ national committee. A complete listing of these bodies can be found on the CENELEC website.
SIST EN 50440:2016/A2:2026 EN 50440:2015/A2:2026 (E)
1 Modification to Clause 1, Scope
Replace the second dash item in the NOTE 1 with the following:
“- storage water heaters that do not use a tank to store hot water;” Replace NOTE 2 with the following:
NOTE 2 This standard does not specify performance or safety requirements. For safety requirements see EN IEC 60335-1 in conjunction with EN IEC 60335-2-21.
2 Modification to Clause 3, “Terms and definitions”
Add the following term entry:
”3.10 rated heat output P rated heat output of the water heater when providing water heating at standard rating conditions, expressed in kW”
3 Modification to Clause 4, “Symbols and Units”
Add the following lines in Table 1:
Table 1 — Symbols Symbol Unit Description Q kWh Electricity consumption during the heat-up period (step 2) heat-up P kW Rated power output in kW rated P kW Nominal power input assigned to the appliance by the manufacturer nom C l Rated capacity of Water Heater, assigned to the appliance by the manufacturer rated
4 Modification to Clause 7, “General conditions for measurements”
Replace Table 3 with the following:
SIST EN 50440:2016/A2:2026 EN 50440:2015/A2:2026 (E)
Table 3 — Test conditions and outputs. Set values and tolerances Permissible Permissible Uncertainty of deviation deviations of Measured quantity Unit Value measurement Notes (average over test individual (accuracy) period) measured values Time Time s ±0,1 Maximum interval between samples (during the deliver s 3 of hot water) Maximum interval between samples (during the no- s 60 deliver of hot water) Sanitary water °C/ cold water temperature 10 ±1 ±1 ±0,5 K 0,3 cold water pressure MPa ±5 %
°C/ a, b hot water temperature pattern ±0,5 K l / volume flowrate pattern ±1 % min volume measurements l ±0,5 % ±2 % ±2 %
thermal energy kWh pattern ±2 % (overall) (or ± 10 Wh) (or ± 10 Wh) Ambient air °C/ Temperature 20 ±1 ±1 K a To be measured by “rapid response thermometer”, meaning an instrument that registers within 1 s. at least 90 % of the final temperature rise from 15 to 100 °C when the sensor is plunged in still water. b Thermocouple with a maximum diameter of 0,5 mm, centred in stream, directly at outlet
Apart from the maximum deviation a correction factor Qref/QH2O is applied, whereby Qref is taken from Table 4 and QH2O is the energy content of the useful water actually delivered during the test. “Useful water” is water with a temperature higher than a threshold value Tm for tappings in a profile specified in Table 4.
5 Modification to Clause 8, “Reference conditions”
Replace the title of the clause as follows: “General test conditions” Add at the beginning of the clause, the title of sub clause:
8.1 Load profile
Add the following Note before the sentence beginning with “For all tests, a cold water temperature …”,
SIST EN 50440:2016/A2:2026 EN 50440:2015/A2:2026 (E)
...