Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers

This International Standard deals with the safety of electric fence energizers, the rated voltage of which is not more than 250 V and by means of which fence wires in agricultural, domestic or feral animal control fences and security fences may be electrified or monitored.

Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-76: Besondere Anforderungen für Elektrozaungeräte

Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Règles particulières pour les électrificateurs de clôtures

Gospodinjski in podobni električni aparati - Varnost - 2-76. del: Posebne zahteve za generatorje impulzov za električne ograje - Dodatek A12

Ta mednarodni standard obravnava varnost generatorjev impulzov za električne ograje, katerih ocenjena napetost je manjša od 250 V, in načine, kako so lahko žice ograje v kmetijskih, gospodinjskih ali ograjah za divje živali ter varnostnih ograjah elektrificirane ali nadzorovane.

General Information

Status
Published
Publication Date
23-Sep-2010
Withdrawal Date
31-Aug-2013
Current Stage
6060 - Document made available - Publishing
Start Date
24-Sep-2010
Completion Date
24-Sep-2010

Relations

Buy Standard

Amendment
EN 60335-2-76:2005/A12:2011
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60335-2-76:2005/A12:2011
01-maj-2011
*RVSRGLQMVNLLQSRGREQLHOHNWULþQLDSDUDWL9DUQRVWGHO3RVHEQH]DKWHYH
]DJHQHUDWRUMHLPSXO]RY]DHOHNWULþQHRJUDMH'RGDWHN$
Household and similar electrical appliances - Safety - Part 2-76: Particular requirements
for electric fence energizers
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-76:
Besondere Anforderungen für Elektrozaungeräte
Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Règles particulières
pour les électrificateurs de clôtures
Ta slovenski standard je istoveten z: EN 60335-2-76:2005/A12:2010
ICS:
65.040.10 Poslopja, naprave in oprema Livestock buildings,
za živino installations and equipment
SIST EN 60335-2-76:2005/A12:2011 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60335-2-76:2005/A12:2011

---------------------- Page: 2 ----------------------

SIST EN 60335-2-76:2005/A12:2011

EUROPEAN STANDARD
EN 60335-2-76/A12

NORME EUROPÉENNE
September 2010
EUROPÄISCHE NORM

ICS 65.040.99


English version


Household and similar electrical appliances -
Safety -
Part 2-76: Particular requirements for electric fence energizers



Appareils électrodomestiques  Sicherheit elektrischer Geräte für den
et analogues - Sécurité - Hausgebrauch und ähnliche Zwecke -
Partie 2-76: Règles particulières pour Teil 2-76: Besondere Anforderungen
les électrificateurs de clôtures für Elektrozaungeräte





This amendment A12 modifies the European Standard EN 60335-2-76:2005; it was approved by CENELEC on
2010-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60335-2-76:2005/A12:2010 E

---------------------- Page: 3 ----------------------

SIST EN 60335-2-76:2005/A12:2011
EN 60335-2-76:2005/A12:2010 – 2 –
Foreword
A proposal to amend EN 60335-2-76:2005 was discussed during the London meeting of CENELEC
TC 61 in December 2008, when it was decided to submit a draft for an amendment to the CENELEC
Enquiry.
The results were discussed at the Sofia meeting in November 2009, when it was decided to submit a
revised draft to the formal vote.
The text was circulated in March 2010 and was approved by CENELEC as amendment A12 to
EN 60335-2-76:2005 on 2010-09-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the amendment has to be implemented

at national level by publication of an identical

national standard or by endorsement
(dop) 2011-09-01

– latest date by which the national standards conflicting

with the amendment have to be withdrawn
(dow) 2013-09-01
__________

---------------------- Page: 4 ----------------------

SIST EN 60335-2-76:2005/A12:2011
– 3 – EN 60335-2-76:2005/A12:2010
19 Abnormal operation
19.1 Replace the modification by:
19.1 Addition:
Energizers are also subjected to the tests of 19.101, 19.102, 19.103, 19.104 and 19.105.
Add:
Annex ZAA
(normative)

Time delayed electric fence energizers
The following modifications to this standard are applicable for time delayed electric fence
energizers.
3 Definitions
3.ZAA.1
time delayed electric fence energizer
electric fence energizer that when a very low load impedance is detected at the output terminals, has
its maximum output impulses limited for th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.