Appliance couplers for household and similar general purposes - Part 3: Standard sheets and gauges

lEC 60320-3:2014 sets the dimensions for appliance couplers for two poles and two poles with earth contact: - for the connection of electrical devices for household and similar onto the mains supply and - for the interconnection of the electrical supply to appliance or equipment - and dimensions for gauges.

Gerätesteckvorrichtungen für den Hausgebrauch und ähnliche allgemeine Zwecke - Teil 3: Normblätter und Lehren

Connecteurs pour usages domestiques et usages généraux analogues - Partie 3: Feuilles de norme et calibres

L'IEC 60320-3:2014 établit les dimensions applicables aux connecteurs bipolaires et bipolaires avec contact de terre : - pour raccordement des dispositifs électriques pour usages domestiques et analogues à l'alimentation électrique et - pour raccordement de l'alimentation électrique aux appareils d'utilisation ou autres matériels électriques - et les dimensions des calibres.

Aparatne spojke za hišno rabo in podobne splošne namene - 3. del: Standardni merilni lističi (IEC 60320-3:2014)

Ta del standarda lEC 60320 določa dimenzije aparatnih spojk za dva pola in dva pola z ozemljitvijo
– za priključitev električnih naprav za hišno rabo in podobnih na omrežno napetost,
– za povezovanje električne oskrbe z aparati ali opremo in
– dimenzije merilnikov.

General Information

Status
Published
Publication Date
11-Dec-2014
Withdrawal Date
27-Nov-2017
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
12-Dec-2014
Completion Date
12-Dec-2014

Relations

Standard
EN 60320-3:2015
English language
82 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2015
$SDUDWQHVSRMNH]DKLãQRUDERLQSRGREQHVSORãQHQDPHQHGHO6WDQGDUGQL
PHULOQLOLVWLþL ,(&
Appliance couplers for household and similar general purposes - Part 3: Standard sheets
and gauges (IEC 60320-3:2014)
*HUlWHVWHFNYRUULFKWXQJHQIUGHQ+DXVJHEUDXFKXQGlKQOLFKHDOOJHPHLQH=ZHFNH7HLO
1RUPEOlWWHUXQG/HKUHQ
,(&
Connecteurs pour usages domestiques et usages généraux analogues - Partie 3:
Feuilles de norme et calibres (CEI 60320-3:2014)
Ta slovenski standard je istoveten z: EN 60320-3:2014
ICS:
29.120.30 9WLþLYWLþQLFHVSRMNH Plugs, socket-outlets,
couplers
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60320-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2014
ICS 29.120.30
English Version
Appliance couplers for household and similar general purposes -
Part 3: Standard sheets and gauges
(IEC 60320-3:2014)
Connecteurs pour usages domestiques et usages généraux Gerätesteckvorrichtungen für den Hausgebrauch und
analogues - Partie 3: Feuilles de norme et calibres ähnliche allgemeine Zwecke - Teil 3: Normblätter und
(CEI 60320-3:2014) Lehren
(IEC 60320-3:2014)
This European Standard was approved by CENELEC on 2014-11-28. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60320-3:2014 E
Foreword
The text of document 23G/336/FDIS, future edition 1 of IEC 60320-3, prepared by SC 23G "Appliance
couplers", of IEC/TC 23 "Electrical accessories" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 60320-3:2014.
The following dates are fixed:
(dop) 2015-08-28
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2017-11-28
• latest date by which the national standards conflicting with
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 60320-3:2014 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
ISO 286-1:2010 NOTE Harmonized as EN ISO 286-1:2010 (not modified).
ISO 1101:2004 NOTE Harmonized as EN ISO 1101:2005 (not modified).

- 3 - EN 60320-3:2014
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60320-1 -  Appliance couplers for household and EN 60320-1 -
similar general purposes -
Part 1: General requirements
IEC 60320-3 ®
Edition 1.0 2014-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Appliance couplers for household and similar general purposes –

Part 3: Standard sheets and gauges

Connecteurs pour usages domestiques et usages généraux analogues –

Partie 3: Feuilles de norme et calibres

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XC
ICS 29.120.30 ISBN 978-2-8322-1875-4

– 2 – IEC 60320-3:2014 © IEC 2014
CONTENTS
FOREWORD . 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 General requirements . 7
5 Standard sheets for appliance couplers . 10
5.1 General . 10
5.2 Position of switch cams . 11
6 Gauges . 11
6.1 General . 11
6.2 Distance to the point of first contact . 11
6.3 "GO" gauge for connectors to standard sheet C1 . 12
6.4 "GO" gauge for connectors to standard sheet C5 . 13
6.5 "GO" -gauge for connectors to standard sheet C7 . 14
6.6 "GO" -gauge for side-entry connectors to standard sheet C7. 15
6.7 "NOT-GO" gauge for connectors to standard sheets C1 . 16
6.8 "NOT-GO" gauge for connectors to standard sheets C1, C5 and C7 . 17
6.9 "NOT-GO" gauge for connectors to standard sheets C1 and C7 . 18
6.10 Blades for checking the resistance against deformation of the front part of
the connector to standard sheet C7 . 19
6.11 "NOT-GO" gauge for appliance inlets to standard sheets C8, C8A and C8B . 19
6.12 "GO" gauge for connectors to standard sheet C9 . 20
6.13 "NOT-GO" gauge for connectors to standard sheet C9 . 21
6.14 "GO" gauge for appliance inlets to standard sheets C10 . 21
6.15 "GO" gauge for connectors to standard sheet C13 . 23
6.16 "NOT-GO" gauge for connectors to standard sheets C13 and C17 . 24
6.17 "GO" gauge for appliance inlets to standard sheets C14, C16 and C18 . 24
6.18 "GO" gauge for connectors to standard sheet C15 . 26
6.19 "GO" gauge for connectors to standard sheet C17 . 27
6.20 "GO" gauge for connectors to standard sheet C19 . 28
6.21 "GO" gauge for appliance inlets to standard sheets C20 and C24 . 29
6.22 "GO" gauge for connectors to standard sheet C21 . 30
6.23 "GO" gauge for appliance inlets to standard sheet C22 . 31
6.24 "GO" gauge for connectors to standard sheet C23 . 32
6.25 "NOT-GO" gauge for connectors to standard sheets C13, C15 and C17 . 33
6.26 "GO" gauge for connectors to standard sheet C15A . 34
6.27 "GO" gauge for appliance inlets to standard sheet C16A . 34
6.28 "GO" gauge for appliance outlets to standard sheet F . 36
6.29 "GO" gauge for appliance outlets to standard sheet H . 37
6.30 "GO" gauge for appliance outlets to standard sheet J . 38
6.31 "GO" gauge for appliance outlets to standard sheet L . 39
6.32 Gauges for checking the distance from the engagement face of connectors
and appliance outlets to the point of first contact . 40
Standard sheet C1 . 41
Standard sheet C2 . 42
Standard sheet C5 . 43

IEC 60320-3:2014 © IEC 2014 – 3 –
Standard sheet C6 . 44
Standard sheet C7 . 45
Standard sheet C8 . 46
Standard sheet C8A . 47
Standard sheet C8B . 48
Standard sheet C9 . 49
Standard sheet C10 . 50
Standard sheet C13 . 51
Standard sheet C14 . 52
Standard sheet C15 . 53
Standard sheet C15A . 54
Standard sheet C16 . 55
Standard sheet C16A . 57
Standard sheet C17 . 58
Standard sheet C18 . 59
Standard sheet C19 . 60
Standard sheet C20 . 61
Standard sheet C21 . 62
Standard sheet C22 . 63
Standard sheet C23 . 64
Standard sheet C24 . 65
Standard sheet C25 . 66
Standard sheet A . 67
Standard sheet C . 69
Standard sheet D . 70
Standard sheet E . 71
Standard sheet G . 73
Standard sheet H . 74
Standard sheet I . 75
Standard sheet J . 76
Standard sheet K . 77
Standard sheet L . 78
Bibliography . 79

Figure 1 – Position of switch cams . 11
Figure 2 – "GO" gauge for connectors to standard sheet C1 . 12
Figure 3 – "GO" gauge for connectors to standard sheet C5 . 13
Figure 4 – "GO" -gauge for connectors to standard sheet C7 . 14
Figure 5 – "Go" -gauge for side-entry connectors to standard sheet C7 . 15
Figure 6 – "NOT-GO" gauge for connectors to standard sheets C1 . 16
Figure 7 – "NOT-GO" gauge for connectors to standard sheets C1, C5 and C7 . 17
Figure 8 – "NOT-GO" gauge for connectors to standard sheets C1 and C7 . 18
Figure 9 – Blades for checking the resistance against deformation . 19

– 4 – IEC 60320-3:2014 © IEC 2014
Figure 10 – "NOT-GO" gauge for appliance inlets to standard sheets C8, C8A and C8B . 19
Figure 11 – "GO" gauge for connectors to standard sheet C9 . 20
Figure 12 – "NOT-GO" gauge for connectors to standard sheet C9 . 21
Figure 13 – "GO" gauge for appliance inlets to standard sheets C10 . 22
Figure 14 – "GO" gauge for connectors to standard sheet C13 . 23
Figure 15 – "NOT-GO" gauge for connectors to standard sheets C13 and C17 . 24
Figure 16 – "GO" gauge for appliance inlets to standard sheets C14, C16 and C18 . 25
Figure 17 – "GO" gauge for connectors to standard sheet C15 . 26
Figure 18 – "GO" gauge for connectors to standard sheet C17 . 27
Figure 19 – "GO" gauge for connectors to standard sheet C19 . 28
Figure 20 – "GO" gauge for appliance inlets to standard sheets C20 and C24. 29
Figure 21 – "GO" gauge for connectors to standard sheet C21 . 30
Figure 22 – "GO" gauge for appliance inlets to standard sheet C22 . 31
Figure 23 – "GO" gauge for connectors to standard sheet C23 . 32
Figure 24 – "NOT-GO" gauge for connectors to standard sheets C13, C15 and C17 . 33
Figure 25 – "GO" gauge for connectors to standard sheet C15A . 34
Figure 26 – "GO" gauge for appliance inlets to standard sheet C16A . 35
Figure 27 – "GO" gauge for appliance outlets to standard sheet F . 36
Figure 28 – "GO" gauge for appliance outlets to standard sheet H . 37
Figure 29 – "GO" gauge for appliance outlets to standard sheet J . 38
Figure 30 – "GO" gauge for appliance outlets to standard sheet L. 39
Figure 31 – Gauges for checking point of first contact . 40

Table 1 – Appliance couplers C1 up to C24 – Standard sheets . 8
Table 2 – Appliance couplers A up to L – Standard sheets . 10
Table 3 – Dimensions of contact gauge . 40

IEC 60320-3:2014 © IEC 2014 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
APPLIANCE COUPLERS FOR HOUSEHOLD
AND SIMILAR GENERAL PURPOSES –

Part 3: Standard sheets and gauges

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60320-3 has been prepared by subcommittee 23G: Appliance
couplers, of IEC technical committee 23: Electrical accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
23G/336/FDIS 23G/338/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

– 6 – IEC 60320-3:2014 © IEC 2014
A list of all the parts in the IEC 60320 series, under the general title Appliance couplers for
household and similar general purposes, can be found on the IEC website.
This part is to be used in conjunction with IEC 60320-1.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IEC 60320-3:2014 © IEC 2014 – 7 –
APPLIANCE COUPLERS FOR HOUSEHOLD
AND SIMILAR GENERAL PURPOSES –

Part 3: Standard sheets and gauges

1 Scope
This part of the lEC 60320 sets the dimensions for appliance couplers for two poles and two
poles with earth contact
– for the connection of electrical devices for household and similar onto the mains supply
and
– for the interconnection of the electrical supply to appliance or equipment
– and dimensions for gauges.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60320-1:—, Appliance couplers for household and similar general purposes – Part 1:
General requirements
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60320-1 apply.
4 General requirements
The general requirements for connecting appliance couplers to the electrical mains supply are
detailed in Table 1.
– 8 – IEC 60320-3:2014 © IEC 2014
Table 1 – Appliance couplers C1 up to C24 – Standard sheets
Rated Class of Maximum APPLIANCE COUPLER Type of cord
current equipment pin
Number of standard sheet for: Rewirable Lightest Minimum
of appliance temperature
construction type allowed cross-
coupler of appliance
allowed section
inlet
appliance inlet connector 2
mm
A °C
a
0,2 II 70 No –
IEC 41
C2     C1
2,5 I 70 No 0,75
IEC 52
C6    C5
b
2,5 II 70 No 0,75
IEC 52
C8    C7
6 II 70 No 0,75
IEC 52
C10     C9
IEC 53
c
10 I 70 Yes or 0,75
IEC 53
C14    C13
IEC 53 or
c
10 I 120 Yes 0,75
60245 IEC
C16    C15
IEC 53
c
10 I 155 Yes or 0,75
60245 IEC
C16A    C15A
IEC 53
c
10 II 70 No or 0,75
IEC 53
C18    C17
IEC 60320-3:2014 © IEC 2014 – 9 –
Rated Class of Maximum APPLIANCE COUPLER Type of cord
current equipment pin
Rewirable Lightest Minimum
Number of standard sheet for:
of appliance temperature
construction type allowed cross-
coupler of appliance
allowed section
inlet
appliance inlet connector 2
mm
A °C
IEC 53
c
16 I 70 Yes or 1
IEC 53
C20    C19
IEC 53 or
c
16 I 155 Yes 1
60245 IEC
C22    C21
IEC 53
c
16 II 70 No or 1
IEC 53
C24    C23
a
Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.
b 2
0,5 mm is allowed for lengths not exceeding 2 m.
c
If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
– 1 mm for 10 A connectors
– 1,5 mm for 16 A connectors.
Table 2 gives the general requirements for appliance couplers for the interconnection of the
electrical supply to appliance or equipment.

– 10 – IEC 60320-3:2014 © IEC 2014
Table 2 – Appliance couplers A up to L – Standard sheets
Rated Class of Maximum Appliance coupler Type of cord
current equipment contact
Number of standard sheet for: Rewirable Lightest Minimum
A temperature
version type cross
of
allowed allowed section
appliance
Plug connector Appliance outlet mm
outlet
°C
2,5 I 70 No 0,75
IEC 52
A B
b
2,5 II 70 No 0,75
IEC 52
C D
IEC 53
c
10 I 70 Yes or 0,75
IEC 53
E F
IEC 53
c
10 II 70 No or 0,75
G H IEC 53
IEC 53
c
16 I 70 Yes or 1,0
IEC 53
I J
IEC 53
c
16 II 70 No or 1,0
IEC 53
K L
a
VOID
b 2
0,5 mm is allowed for lengths not exceeding 2 m
c
If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be
– 1 mm for 10 A plug connectors
– 1,5 mm for 16 A plug connectors

5 Standard sheets for appliance couplers
5.1 General
The appliance couplers shall comply with the requirements of IEC 60320-1.
Appliance couplers shall comply with the appropriate standard sheets as specified in this
standard.
NOTE 1 The sketches are not intended to govern design, except as regards the dimensions shown.

IEC 60320-3:2014 © IEC 2014 – 11 –
NOTE 2 For the symbols indicating the tolerance of form or of position, see ISO 1101.
NOTE 3 If limits and fits according to ISO 286-1 are used in the standard sheets and figures, the envelope
principle is used.
5.2 Position of switch cams
The operation of the switch shall be effected 1,5 mm before full engagement of the connector
for appliance inlets according standard sheets C8, C8A and C8B the switch cams shall be
positioned as shown in Figure 1.
IEC
For appliance inlets to For appliance inlets to
standard sheets C8 and C8A standard sheet C8B
1)
Minimum dimensions of the switch cams. A key is not required where a switch cam is situated.
Figure 1 – Position of switch cams
6 Gauges
6.1 General
The gauges are used with the force as mentioned in the relevant standard sheet of the gauge.
NOTE For the purpose of verifying whether or not the appliance coupler is fully inserted, it is recommended that
the gauge be provided with an aperture.
Gauges and pins shall be made of hardened steel.
6.2 Distance to the point of first contact
The distance from the engagement face of connectors / appliance outlets to the point of first
contact of socket contacts shall be checked by means of the relevant gauge shown in Figure
31 and Table 3.
– 12 – IEC 60320-3:2014 © IEC 2014
6.3 "GO" gauge for connectors to standard sheet C1
It shall be possible to insert the connector fully into the gauge shown in Figure 2 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 2 – "GO" gauge for connectors to standard sheet C1

IEC 60320-3:2014 © IEC 2014 – 13 –
6.4 "GO" gauge for connectors to standard sheet C5
It shall be possible to insert the connector fully into the gauge shown in Figure 3 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 3 – "GO" gauge for connectors to standard sheet C5

– 14 – IEC 60320-3:2014 © IEC 2014
6.5 "GO" -gauge for connectors to standard sheet C7
It shall be possible to insert the connector fully into the gauge shown in Figure 4 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 4 – "GO" -gauge for connectors to standard sheet C7

IEC 60320-3:2014 © IEC 2014 – 15 –
6.6 "GO" -gauge for side-entry connectors to standard sheet C7
It shall be possible to insert the connector fully into the gauge shown in Figure 5 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 5 – "Go" -gauge for side-entry connectors to standard sheet C7

– 16 – IEC 60320-3:2014 © IEC 2014
6.7 "NOT-GO" gauge for connectors to standard sheets C1
It shall not be possible to insert the connector into the gauge shown in Figure 6 with a force of
60 N.
Dimensions in millimetres
IEC
Figure 6 – "NOT-GO" gauge for connectors to standard sheets C1

IEC 60320-3:2014 © IEC 2014 – 17 –
6.8 "NOT-GO" gauge for connectors to standard sheets C1, C5 and C7
It shall not be possible to insert the connector into the gauge shown in Figure 7 with a force of
60 N.
Dimensions in millimetres
IEC
Figure 7 – "NOT-GO" gauge for connectors to standard sheets C1, C5 and C7

– 18 – IEC 60320-3:2014 © IEC 2014
6.9 "NOT-GO" gauge for connectors to standard sheets C1 and C7
It shall not be possible to insert the connector into the gauge shown in Figure 8 with a force of
60 N.
Dimensions in millimetres
IEC
Figure 8 – "NOT-GO" gauge for connectors to standard sheets C1 and C7

IEC 60320-3:2014 © IEC 2014 – 19 –
6.10 Blades for checking the resistance against deformation of the front part of the
connector to standard sheet C7
For 2,5 A connectors for class II equipment according to standard sheet C7 shall be
sufficiently resistant to deformation. The blades shown in Figure 9 is used for compliance test.
Dimensions in millimetres
IEC
Figure 9 – Blades for checking the resistance against deformation
6.11 "NOT-GO" gauge for appliance inlets to standard sheets C8, C8A and C8B
When the gauge shown in Figure 10 is inserted between the ridges of the appliance inlet with
a force of 30 N, it shall not touch the bottom of the inlet.
Dimensions in millimetres
IEC
Figure 10 – "NOT-GO" gauge for appliance inlets
to standard sheets C8, C8A and C8B

– 20 – IEC 60320-3:2014 © IEC 2014
6.12 "GO" gauge for connectors to standard sheet C9
It shall be possible to insert the connector fully into the gauge shown in Figure 11 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 11 – "GO" gauge for connectors to standard sheet C9

IEC 60320-3:2014 © IEC 2014 – 21 –
6.13 "NOT-GO" gauge for connectors to standard sheet C9
It shall not be possible to insert the connector into the gauge shown in Figure 12 with a force
of 60 N.
Dimensions in millimetres
IEC
Figure 12 – "NOT-GO" gauge for connectors to standard sheet C9
6.14 "GO" gauge for appliance inlets to standard sheets C10
It shall be possible to insert the connector fully into the gauge shown in Figure 13 with a force
not exceeding 60 N.
The thickness of the gauge plate K, as well as the nominal values of the dimensions s and t of
the handle and of the hole in the gauge plate, are left free, but the tolerances h7 and F8 shall
be respected.
The plane A-A of the inlet shall lie between planes B-B and C-C of the gauge.
Then the gauge plate K shall be pushed over the handle to check the free area around the
inlet opening.
– 22 – IEC 60320-3:2014 © IEC 2014
Dimensions in millimetres
IEC
Figure 13 – "GO" gauge for appliance inlets to standard sheets C10

IEC 60320-3:2014 © IEC 2014 – 23 –
6.15 "GO" gauge for connectors to standard sheet C13
It shall be possible to insert the connector fully into the gauge shown in Figure 14 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 14 – "GO" gauge for connectors to standard sheet C13

– 24 – IEC 60320-3:2014 © IEC 2014
6.16 "NOT-GO" gauge for connectors to standard sheets C13 and C17
It shall not be possible to insert the connector into the gauge shown in Figure 15 with a force
of 60 N.
Dimensions in millimetres
IEC
Figure 15 – "NOT-GO" gauge for connectors to standard sheets C13 and C17

6.17 "GO" gauge for appliance inlets to standard sheets C14, C16 and C18
It shall be possible to insert the gauge in 16 fully into the appliance inlet with a force not
exceeding 60 N.
The thickness of the gauge plate K, as well as the nominal values of the dimensions s and t of
the handle and of the hole in the gauge plate, are left free, but the tolerances h7 and F8 shall
be respected.
The plane A-A of the inlet shall lie between planes B-B and C-C of the gauge.
Then the gauge plate K shall be pushed over the handle to check the free area around the
inlet opening.
IEC 60320-3:2014 © IEC 2014 – 25 –
Dimensions in millimetres
IEC
Figure 16 – "GO" gauge for appliance inlets to standard sheets C14, C16 and C18

– 26 – IEC 60320-3:2014 © IEC 2014
6.18 "GO" gauge for connectors to standard sheet C15
It shall be possible to insert the connector fully into the gauge shown in Figure 17 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 17 – "GO" gauge for connectors to standard sheet C15

IEC 60320-3:2014 © IEC 2014 – 27 –
6.19 "GO" gauge for connectors to standard sheet C17
It shall be possible to insert the connector fully into the gauge shown in Figure 18 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 18 – "GO" gauge for connectors to standard sheet C17

– 28 – IEC 60320-3:2014 © IEC 2014
6.20 "GO" gauge for connectors to standard sheet C19
It shall be possible to insert the connector fully into the gauge shown in Figure 19 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 19 – "GO" gauge for connectors to standard sheet C19

IEC 60320-3:2014 © IEC 2014 – 29 –
6.21 "GO" gauge for appliance inlets to standard sheets C20 and C24
It shall be possible to insert the gauge shown in Figure 20 fully into the appliance inlet with a
force not exceeding 60 N.
The thickness of the gauge plate K, as well as the nominal values of the dimensions s and t of
the handle and of the hole in the gauge plate, are left free, but the tolerances h7 and F8 shall
be respected.
The plane A-A of the inlet shall lie between planes B-B and C-C of the gauge.
Then the gauge plate K shall be pushed over the handle to check the free area around the
inlet opening.
Dimensions in millimetres
IEC
Figure 20 – "GO" gauge for appliance inlets to standard sheets C20 and C24

– 30 – IEC 60320-3:2014 © IEC 2014
6.22 "GO" gauge for connectors to standard sheet C21
It shall be possible to insert the connector fully into the gauge shown in Figure 21 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 21 – "GO" gauge for connectors to standard sheet C21

IEC 60320-3:2014 © IEC 2014 – 31 –
6.23 "GO" gauge for appliance inlets to standard sheet C22
It shall be possible to insert the gauge shown in Figure 22 fully into the appliance inlet with a
force not exceeding 60 N.
The thickness of the gauge plate K, as well as the nominal values of the dimensions s and t of
the handle and of the hole in the gauge plate, are left free, but the tolerances h7 and F8 shall
be respected.
The plane A-A of the inlet shall lie between planes B-B and C-C of the gauge.
Then the gauge plate K shall be pushed over the handle to check the free area around the
inlet opening.
Dimensions in millimetres
IEC
Figure 22 – "GO" gauge for appliance inlets to standard sheet C22

– 32 – IEC 60320-3:2014 © IEC 2014
6.24 "GO" gauge for connectors to standard sheet C23
It shall be possible to insert the connector fully into the gauge shown in Figure 23 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 23 – "GO" gauge for connectors to standard sheet C23

IEC 60320-3:2014 © IEC 2014 – 33 –
6.25 "NOT-GO" gauge for connectors to standard sheets C13, C15 and C17
It shall not be possible to insert the connector into the gauge shown in Figure 24 with a force
of 60 N.
Dimensions in millimetres
IEC
Figure 24 – "NOT-GO" gauge for connectors to standard sheets C13, C15 and C17

– 34 – IEC 60320-3:2014 © IEC 2014
6.26 "GO" gauge for connectors to standard sheet C15A
It shall be possible to insert the connector fully into the gauge shown in Figure 25 with a force
not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 25 – "GO" gauge for connectors to standard sheet C15A
6.27 "GO" gauge for appliance inlets to standard sheet C16A
It shall be possible to insert the gauge shown in Figure 26 fully into the appliance inlet with a
force not exceeding 60 N.
The thickness of the gauge plate K, as well as the nominal values of the dimensions s and t of
the handle and of the hole in the gauge plate, are left free, but the tolerances h7 and F8 shall
be respected.
The plane A-A of the inlet shall lie between planes B-B and C-C of the gauge.
Then the gauge plate K shall be pushed over the handle to check the free area around the
inlet opening.
IEC 60320-3:2014 © IEC 2014 – 35 –
Dimensions in millimetres
IEC
Figure 26 – "GO" gauge for appliance inlets to standard sheet C16A

– 36 – IEC 60320-3:2014 © IEC 2014
6.28 "GO" gauge for appliance outlets to standard sheet F
It shall be possible to insert the appliance outlet fully into the gauge shown in Figure 27 with a
force not exceeding 60 N.
Dimensions in millimeters
IEC
Figure 27 – "GO" gauge for appliance outlets to standard sheet F

IEC 60320-3:2014 © IEC 2014 – 37 –
6.29 "GO" gauge for appliance outlets to standard sheet H
It shall be possible to insert the appliance outlet fully into the gauge shown in Figure 28 with a
force not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 28 – "GO" gauge for appliance outlets to standard sheet H

– 38 – IEC 60320-3:2014 © IEC 2014
6.30 "GO" gauge for appliance outlets to standard sheet J
It shall be possible to insert the appliance outlet fully into the gauge shown in Figure 29 with a
force not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 29 – "GO" gauge for appliance outlets to standard sheet J

IEC 60320-3:2014 © IEC 2014 – 39 –
6.31 "GO" gauge for appliance outlets to standard sheet L
It shall be possible to insert the appliance outlet fully into the gauge shown in Figure 30 with a
force not exceeding 60 N.
Dimensions in millimetres
IEC
Figure 30 – "GO" gauge for appliance outlets to standard sheet L

– 40 – IEC 60320-3:2014 © IEC 2014
6.32 Gauges for checking the distance from the engagement face of connectors and
appliance outlets to the point of first contact
The appropriate gauge shall be applied to the entry hole of each socket contact of the
connector with a force not exceeding 5 N. When the gauge is fully inserted, the longer pin of
the gauge ("contact gauge") shall make contact and the shorter pin ("no contact gauge") shall
not make contact (see Figure 31). See Table 3 for dimensions of contact gauge.
An electrical indicator with a voltage between 24 V and 50 V is used to show contact with the
relevant socket contact.
...

Questions, Comments and Discussion