Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers

This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage
of which is not more than 250 V and by means of which fence wires in agricultural, domestic
or feral animal control fences and security fences may be electrified or monitored.
NOTE 101 Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers;
– battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101
and Figure 102;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not in general take into account
– the use of appliances by young children or infirm persons without supervision;
– the playing with appliances by young children.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
NOTE 103 This standard does not apply to
– electromagnetically coupled animal trainer collars;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601

Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-76: Besondere Anforderungen für Elektrozaungeräte

Applicable to the safety of electric fence energizers, the rated voltage of which is not more than 250 V.

Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Règles particulières pour les électrificateurs de clôtures

Gospodinjski in podobni električni aparati - Varnost - 2-76. del: Posebne zahteve za generatorje impulzov za električne ograje

To točko 1. dela nadomešča naslednje besedilo. Ta del standarda IEC 60335 obravnava varnost generatorjev impulzov za električne ograje, katerih nazivna napetost ne presega 250 V in s pomočjo katerih so lahko žice ograje v kmetijskih ograjah, ograjah za odganjanje domačih ali divjih živali in varnostnih ograjah elektrificirane ali nadzorovane.
OPOMBA 101: Primeri generatorjev impulzov za električne ograje, ki spadajo na področje uporabe tega standarda so: – električni generatorji impulzov; – baterijski generatorji impulzov, primerni za priključitev na električno omrežje, kot je prikazano na slikah 101 in 102; – generatorji impulzov za električne ograje, ki delujejo na nepolnljive baterije (vgrajene ali na voljo ločeno). Ta standard na splošno ne vključuje primerov: – ko aparate brez nadzora uporabljajo majhni otroci ali onemogle osebe; – ko se majhni otroci igrajo z aparati.
OPOMBA 102: Opozoriti je treba, da: – so za aparate, ki so namenjeni za uporabo na krovu ladij ali letal, morda potrebne dodatne zahteve; – v številnih državah nacionalni zdravstveni organi, nacionalni organi, odgovorni za varstvo pri delu, nacionalni organi za oskrbo z vodo ter drugi podobni organi določajo dodatne zahteve.
OPOMBA 103: Ta standard se ne uporablja za: – električne ovratnice za usposabljanje živali; – aparate, ki so namenjeni za uporabo na lokacijah, kjer veljajo posebne razmere, kot je prisotnost korozivne ali eksplozivne atmosfere (prah, hlapi ali plin); – polnilnike baterij, ki so na voljo ločeno (IEC 60335-2-29); – električne ribiške stroje (IEC 60335-2-86); – električno opremo za omamljanje živali (IEC 60335-2-87); – aparate za medicinsko uporabo (IEC 60601).

General Information

Status
Published
Publication Date
12-Jan-2022
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
13-Dec-2021
Due Date
17-Feb-2022
Completion Date
13-Jan-2022

Relations

Buy Standard

Standard
EN IEC 60335-2-76:2022 - BARVE
English language
63 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 60335-2-76:2022
01-februar-2022
Nadomešča:
SIST EN 60335-2-76:2005
SIST EN 60335-2-76:2005/A1:2006
SIST EN 60335-2-76:2005/A11:2008
SIST EN 60335-2-76:2005/A12:2011
SIST EN 60335-2-76:2005/A2:2015
Gospodinjski in podobni električni aparati - Varnost - 2-76. del: Posebne zahteve
za generatorje impulzov za električne ograje
Household and similar electrical appliances - Safety - Part 2-76: Particular requirements
for electric fence energizers
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-76:
Besondere Anforderungen für Elektrozaungeräte
Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Règles particulières
pour les électrificateurs de clôtures
Ta slovenski standard je istoveten z: EN IEC 60335-2-76:2021
ICS:
65.040.10 Poslopja, naprave in oprema Livestock buildings,
za živino installations and equipment
SIST EN IEC 60335-2-76:2022 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 60335-2-76:2022

---------------------- Page: 2 ----------------------
SIST EN IEC 60335-2-76:2022


EUROPEAN STANDARD EN IEC 60335-2-76

NORME EUROPÉENNE

EUROPÄISCHE NORM
October 2021
ICS 65.040.99 Supersedes EN 60335-2-76:2005 and all of its
amendments and corrigenda (if any)
English Version
Household and similar electrical appliances - Safety - Part 2-76:
Particular requirements for electric fence energizers
(IEC 60335-2-76:2018 + COR1:2018)
Appareils électrodomestiques et analogues - Sécurité - Sicherheit elektrischer Geräte für den Hausgebrauch und
Partie 2-76: Règles particulières pour les électrificateurs de ähnliche Zwecke - Teil 2-76: Besondere Anforderungen für
clôtures Elektrozaungeräte
(IEC 60335-2-76:2018 + COR1:2018) (IEC 60335-2-76:2018 + COR1:2018)
This European Standard was approved by CENELEC on 2021-09-20. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 60335-2-76:2021 E

---------------------- Page: 3 ----------------------
SIST EN IEC 60335-2-76:2022
EN IEC 60335-2-76:2021 (E)
European foreword
This document EN IEC 60335-2-76:2021 consists of the text of IEC 60335-2-76:2018 prepared by
IEC/TC 61 "Safety of household and similar electrical appliances".
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2022-09-20
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-09-20
document have to be withdrawn
This document supersedes EN 60335-2-76:2005 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document is read in conjunction with EN IEC 60335-2-76:2021/A11:2021.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 60335-2-76:2018 was approved by CENELEC as a
European Standard.

2

---------------------- Page: 4 ----------------------
SIST EN IEC 60335-2-76:2022




IEC 60335-2-76

®


Edition 3.0 2018-06




INTERNATIONAL



STANDARD








colour

inside










Household and similar electrical appliances – Safety –

Part 2-76: Particular requirements for electric fence energizers



























INTERNATIONAL

ELECTROTECHNICAL

COMMISSION





ICS 65.040.99 ISBN 978-2-8322-5808-8




  Warning! Make sure that you obtained this publication from an authorized distributor.


® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 5 ----------------------
SIST EN IEC 60335-2-76:2022
– 2 – IEC 60335-2-76:2018 © IEC 2018
CONTENTS
FOREWORD . 4
INTRODUCTION . 7
1 Scope . 8
2 Normative references. 8
3 Terms and definitions . 9
4 General requirement . 13
5 General conditions for the tests . 13
6 Classification . 14
7 Marking and instructions . 15
8 Protection against access to live parts . 18
9 Starting of motor-operated appliances . 18
10 Power input and current . 18
11 Heating . 18
12 Void . 20
13 Leakage current and electric strength at operating temperature . 20
14 Transient overvoltages. 21
15 Moisture resistance . 22
16 Leakage current and electric strength . 22
17 Overload protection of transformers and associated circuits . 23
18 Endurance . 23
19 Abnormal operation . 24
20 Stability and mechanical hazards . 26
21 Mechanical strength . 26
22 Construction . 27
23 Internal wiring . 31
24 Components . 32
25 Supply connection and external flexible cords . 32
26 Terminals for external conductors . 32
27 Provision for earthing . 33
28 Screws and connections . 33
29 Clearances, creepage distances and solid insulation . 33
30 Resistance to heat and fire . 33
31 Resistance to rusting . 34
32 Radiation, toxicity and similar hazards . 34
Annexes . 40
Annex A (informative) Routine tests . 40
Annex B (normative) Appliances powered by rechargeable batteries that are
recharged in the appliance . 41
Annex S (normative) Battery-operated appliances powered by batteries that are non-
rechargeable or not recharged in the appliance . 43
Annex AA (informative) Circuit for the independent control of the switching speed of
the major impulse-switching device . 47

---------------------- Page: 6 ----------------------
SIST EN IEC 60335-2-76:2022
IEC 60335-2-76:2018 © IEC 2018 – 3 –
Annex BB (normative) Instructions for installation and connection of electric fences . 48
BB.1 Instructions for electric animal fences . 48
BB.2 Instructions for electric security fences not supplied from a security
energizer group . 50
BB.3 Instructions for electric security fences supplied from a security energizer
group . 52
Annex CC (informative) Installation of electric security fences . 56
CC.1 General . 56
CC.2 Location of electric security fence . 56
CC.3 Prohibited zone for pulsed conductors . 56
CC.4 Separation between electric fence and physical barrier . 56
CC.5 Prohibited mounting . 57
CC.6 Operation of electric security fence . 57
Bibliography . 60

Figure 101 – Schematic examples of type A energizers, type B energizers
and type C energizers . 35
Figure 102 – Schematic examples of the different types of type D energizers . 36
Figure 103 – Current limited energizer characteristic limit line . 37
Figure 104 – Type R security energizer group test configurations . 38
Figure 105 – Type S security energizer group test configurations . 39
Figure AA.1 – Circuit for the independent control of the switching speed of the major
impulse-switching device . 47
Figure BB.1 – Symbol for warning sign . 55
Figure CC.1 – Prohibited area for pulse conductors . 57
Figure CC.2 – Typical constructions where an electric security fence is exposed
to the public . 58
Figure CC.3 – Typical fence constructions where the electric security fence is installed
in windows and skylights . 59

Table 101 – Battery source impedance . 19
Table 102 – Rated supply voltage maximum and minimum value multiplier factors . 19
Table 103 – Supply voltage value test settings . 20
Table 104 – Test supply sequence for different supply type . 20
Table 105 – Additional test voltages . 23
Table BB.1 – Minimum clearances from power lines for electric animal fences . 49
Table BB.2 – Minimum clearances from power lines for electric security fences not
supplied from a security energizer group . 51
Table BB.3 – Minimum clearances from power lines for electric security fences

supplied from a security energizer group . 54

---------------------- Page: 7 ----------------------
SIST EN IEC 60335-2-76:2022
– 4 – IEC 60335-2-76:2018 © IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –

Part 2-76: Particular requirements for electric fence energizers

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61H:
Safety of electrically-operated farm appliances, of IEC technical committee 61: Safety of
household and similar electrical appliances.
This third edition cancels and replaces the second edition published in 2002,
Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
• the text has been aligned with Edition 5.2 of Part 1;
• additional requirements for security fence energizers have been introduced (Clauses 3, 7,
19, 22, Figures and Annex BB);
• specific requirements for battery operated energizers have been moved to Annex S.

---------------------- Page: 8 ----------------------
SIST EN IEC 60335-2-76:2022
IEC 60335-2-76:2018 © IEC 2018 – 5 –
The text of this International Standard is based on the following documents:
FDIS Report on voting
61H/366/FDIS 61H/367/RVD

Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60335 series, published under the general title Household and
similar electrical appliances – Safety, can be found on the IEC website.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fifth edition (2010) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This Part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for electric fence
energizers.
When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies
as far as is reasonable. When this standard states “addition”, “modification” or “replacement”,
the relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional Annexes are lettered AA, BB, etc.
NOTE 3 The following print types are used:
– requirements: in roman type
– test specifications: in italic type
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and
associated noun are also in bold.
NOTE 4 The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation
nationally not earlier than 12 months or later than 36 months from the date of publication.
The following differences exist in the countries indicated below:
6.101: Only energy limited energizers are allowed (All EU and EFTA counties).

---------------------- Page: 9 ----------------------
SIST EN IEC 60335-2-76:2022
– 6 – IEC 60335-2-76:2018 © IEC 2018
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
 reconfirmed,
 withdrawn,
 replaced by a revised edition, or
 amended.
A bilingual version of this publication may be issued at a later date.
The contents of the corrigendum of November 2018 have been included in this copy.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 10 ----------------------
SIST EN IEC 60335-2-76:2022
IEC 60335-2-76:2018 © IEC 2018 – 7 –
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in
normal use taking into account the manufacturer's instructions. It also covers abnormal
situations that can be expected in practice and takes into account the way in which
electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply
mains. However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
NOTE 1 Throughout this publication, when “Part 1” is mentioned, it refers to IEC 60335-1.
When a part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.
NOTE 2 This means that the technical committees responsible for the part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 3 Horizontal and generic standards covering a hazard are not applicable since they have been taken into
consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as
ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.

---------------------- Page: 11 ----------------------
SIST EN IEC 60335-2-76:2022
– 8 – IEC 60335-2-76:2018 © IEC 2018
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –

Part 2-76: Particular requirements for electric fence energizers



1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage
of which is not more than 250 V and by means of which fence wires in agricultural, domestic
or feral animal control fences and security fences may be electrified or monitored.
NOTE 101 Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers;
– battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101
and Figure 102;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not in general take into account
– the use of appliances by young children or infirm persons without supervision;
– the playing with appliances by young children.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
NOTE 103 This standard does not apply to
– electromagnetically coupled animal trainer collars;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601).
2 Normative references
This clause of Part 1 is applicable except as follows.
Addition:
IEC 60068-2-52:2017, Environmental testing – Part 2: Tests – Test Kb: Salt mist, cyclic
(sodium chloride solution)
IEC 60320-3, Appliance couplers for household and similar general purposes – Part 3:
Standard sheets and gauges
ISO 3864-1, Graphical symbols – Safety colours and safety signs – Part 1: Design principles
for safety signs and safety markings

---------------------- Page: 12 ----------------------
SIST EN IEC 60335-2-76:2022
IEC 60335-2-76:2018 © IEC 2018 – 9 –
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1 Definitions relating to physical characteristics
3.1.1 Addition:
Note 1 to entry: For type D energizers, the rated voltage of the energizer is the rated voltage for battery
supply.
Replacement:
3.1.9
normal operation
operation of the appliance under the following conditions: the electric fence energizer is
operated as in normal use when connected to the supply, with no load connected to the
output terminals
3.1.101
prospective peak voltage
peak output voltage of the impulse generator specified in Clause 14 that would be obtained
with the energizer not connected to the test circuit
3.1.102
rated voltage for battery supply
voltage for battery supply, for type A energizers, type B energizers, type C energizers and
type D energizers assigned to the energizer by the manufacturer
3.1.103
rated voltage range for battery supply
voltage range for battery supply, for type A energizers, type B energizers, type C
energizers and type D energizers assigned to the energizer by the manufacturer, expressed
by its lower and upper limits
3.1.104
impulse duration
duration of that part of the impulse that contains 95 % of the overall energy and is the shortest
2 2
interval of integration of I (t) that gives 95 % of the integration of I (t) over the total impulse
Note 1 to entry: I(t) is the impulse current as a function of time.
3.1.105
output current
RMS value of the output current per impulse calculated over the impulse duration
3.5 Definitions relating to types of appliances
3.5.101
electric fence energizer
appliance that is intended to deliver periodically voltage impulses to a fence connected to it
Note 1 to entry: Electric fence energizers are hereinafter also referred to as energizers.
3.5.102
mains-operated energizer
energizer designed for direct connection to the mains

---------------------- Page: 13 ----------------------
SIST EN IEC 60335-2-76:2022
– 10 – IEC 60335-2-76:2018 © IEC 2018
3.5.103
battery-operated energizer suitable for connection to the mains
energizer
– operated by batteries and having, or being designed
...

Questions, Comments and Discussion