EN 60255-24:2001
(Main)Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
- BACK
- 03-Jul-2001
- 31-Jan-2002
- 29.120.70
- CLC/TC 95X
Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
Defines a format for files containing transient waveform and event data collected from power systems or power system models. Applies to files stored on physical media such as digital hard drives and diskettes.
Elektrische Relais - Teil 24: Standardformat für den Austausch von transienten Daten elektrischer Energieversorgungsnetze (COMTRADE)
Relais électriques - Partie 24: Format commun pour l'échange de données transitoires (CONTRADE) dans les réseaux électriques
Etablit un format pour les fichiers contenant des données sur les événements et les formes d'ondes des transitoires obtenus à partir des réseaux électriques ou de leur modélisation. S'applique à des fichiers destinés à être stockés sur des supports physiques, tels que des disques durs ou des disquettes.
Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
General Information
This May Also Interest You
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Apr-2023
- 29.120.70
- CLC/TC 95X
IEC 60255-1:2022 specifies common rules and requirements applicable to measuring relays and protection equipment, including any combination of equipment to form a distributed protection scheme for power system protection such as control, monitoring and process interface equipment, to obtain uniformity of requirements and tests. This document covers the main technologies in use today; other emerging technologies present specific EMC and safety issues but the philosophy in this document will be applied. This second edition cancels and replaces the first edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition: a. scope of document clarified; b. merging units and communications as an integral part of the protection added; c. binary output clarification expanded; d. environmental operating conditions added (Annex B); e. test reference conditions added; f. multiple changes to improve understanding across most clauses; g. derating by manufacturer added; h. safety and EMC tests removed from document and referenced only; i. relay setting and type test guidelines modified (Annex A) j. battery monitor port and low power instrument transformers added.
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Jan-2023
- 29.120.70
- CLC/TC 95X
IEC 60255-187-1:2021 specifies the minimum requirements for functional and performance evaluation of (longitudinal) differential protection designed for the detection of faults in ac motors, generators and transformers. This document also defines how to document and publish performance test results. This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document. This document, together with IEC 60255-187-2 and IEC 60255-187-3, cancels and replaces IEC 60255-13. This document includes the following significant technical changes with respect to IEC 60255-13: a) IEC 60255-13 has been significantly revised to follow the common structure of the functional standards for protection relays (IEC 60255-1xx series). IEC 60255-187-1 has been developed to address the restrained and unrestrained differential protection of motors, generators and transformers. The revisions include detailed description of the functions including the performance specification, testing and documentation requirements.
- Standard208 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard208 pagesEnglish languagesale 10% offe-Library read for×1 day
- 16-Sep-2021
- 29.120.70
- CLC/TC 95X
IEC 60255-181:2019 specifies the minimum requirements for functional and performance evaluation of frequency protection. This document also defines how to document and publish performance test results. This document covers the functions based on frequency measurement or rate of change of frequency measurements. This document also covers frequency protection where additional blocking elements are used. This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document.
- Standard93 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Apr-2019
- 02-Apr-2022
- 29.120.70
- CLC/TC 95X
IEC 60255-121:2014 specifies minimum requirements for functional and performance evaluation of distance protection function typically used in, but not limited to, line applications for effectively earthed, three-phase power systems. This standard also defines how to document and publish performance tests. This standard covers distance protection function whose operating characteristic can be defined on an impedance plane and includes specification of the protection function, measurement characteristics, phase selection, directionality, starting and time delay characteristics. The test methodologies for verifying performance characteristics and accuracy are included in this standard. The standard defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. It also includes the instrument transformer requirements for the protection function. The general requirements for measuring relays and protection equipment are defined in IEC 60255-1.
- Standard150 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Jul-2014
- 10-Apr-2017
- 29.120.70
- CLC/TC 95X
IEC 60255-27:2013 describes the product safety requirements for measuring relays and protection equipment having a rated a.c. voltage up to 1 000 V with a rated frequency up to 65 Hz, or a rated d.c. voltage up to 1 500 V. Above these limits, IEC 60664-1 is applicable for the determination of clearance, creepage distance and withstand test voltage. This standard details essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user. This new edition includes the following significant technical changes with respect to the previous edition: - the removal of tables and diagrams which are from other standards and referring instead directly to the source standard; - all aspects of IEC 60255-5 have been covered and this standard will be withdrawn.
- Standard99 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2014
- 18-Nov-2016
- 29.120.70
- 2006/95/EC
- 2014/35/EU
- 2014/53/EU
- CLC/TC 95X
IEC 60255-127:2010 specifies minimum requirements for over/under voltage relays. The standard includes specification of the protection function, measurement characteristics and time delay characteristics.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Jan-2014
- 18-Sep-2016
- 29.120.70
- CLC/TC 95X
This part of the IEC 60255 series is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. Tests specified in this standard are not required for equipment not incorporating electronic circuits, for example electromechanical relays. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only.
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for×1 day
IEC 60255-149:2013 specifies minimum requirements for thermal protection relays. This standard includes specification of the protection function, measurement characteristics and test methodologies. The object is to establish a common and reproducible reference for evaluating dependent time relays which protect equipment from thermal damage by measuring a.c. current flowing through the equipment. Complementary input energizing quantities such as ambient, coolant, top oil and winding temperature may be applicable for the thermal protection specification set forth in this standard. This standard covers protection relays based on a thermal model with memory function.
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Oct-2013
- 02-Sep-2016
- 29.120.70
- CLC/TC 95X
IEC 60255-26:2013 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. This new edition includes the following significant technical changes with respect to the previous edition: - definition of test specifications, test procedures and acceptance criteria per phenomena and port under test in one document; - extension of radiated emission measurement for frequencies above 1 GHz; - limitation of radiated emission measurement at 3 m distance for small equipment only; - addition of zone A and zone B test level on surge test; - extension of tests on the auxiliary power supply port by a.c. and d.c. voltage dips, a.c. component in d.c. (ripple) and gradual shut-down/start-up; - harmonization of acceptance criteria for immunity tests.
- Standard51 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Sep-2013
- 27-Jun-2016
- 29.120.70
- 2004/108/EC
- 2004/108/EU
- 2014/30/EU
- CLC/TC 95X
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.