Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

applies to electrical and electronic apparatus intended for use in industrial environments, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard, but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.

Elektromagnetische Verträglichkeit (EMV) - Teil 6-2: Fachgrundnormen - Störfestigkeit für Industriebereiche

Compatibilité électromagnétique (CEM) - Partie 6-2: Normes génériques - Immunité pour les environnements industriels

S'applique aux appareils électriques et électroniques destinés à être utilisés dans des environnements industriels, tels qu'ils sont décrits ci-dessous. Cette partie couvre les exigences d'immunité dans la gamme de fréquences de 0 kHz à 400 GHz. Il n'est pas nécessaire de réaliser des essais aux fréquences pour lesquelles aucune exigence n'est spécifiée. Cette norme générique d'immunité CEM s'applique en l'absence de norme d'immunité CEM applicable spécifique à un produit ou à une famille de produits. Les appareils couverts par cette norme sont destinés à être raccordés à un réseau d'énergie alimenté par un transformateur haute tension ou moyenne tension réservé à l'alimentation d'une l'installation alimentant un site industriel ou analogue, et destinés à fonctionner à l'intérieur ou à proximité des sites industriels, comme défini ci-dessous. Cette norme s'applique également aux appareils qui sont alimentés par piles ou accumulateurs et qui sont destinés à être utilisés dans des sites industriels. Les environnements couverts par cette norme sont les environnements industriels, intérieurs et extérieurs. Les exigences d'immunité ont été choisies pour assurer un niveau adéquat d'immunité pour les appareils utilisés sur des sites industriels. Ces niveaux ne couvrent pas cependant les cas extrêmes qui peuvent apparaître, mais avec une très faible probabilité, sur un site quelconque. Cette norme ne comporte pas, pour les besoins des essais, tous les phénomènes perturbateurs mais uniquement ceux considérés comme applicables pour les appareils couverts par la norme. Ces exigences d'essais représentent les exigences essentielles de compatibilité électromagnétique concernant l'immunité.

Elektromagnetna združljivost (EMC) – 6-2. del: Osnovni standardi – Odpornost za industrijska okolja (IEC 61000-6-2:2005) (vsebuje popravek AC:2005)

General Information

Status
Withdrawn
Publication Date
25-Aug-2005
Withdrawal Date
31-May-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-Feb-2022
Completion Date
22-Feb-2022

Relations

Buy Standard

Standard
EN 61000-6-2:2005
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61000-6-2:2005
01-november-2005
1DGRPHãþD
SIST EN 61000-6-2:2002
SIST EN 61000-6-2:2002/IS1:2006
Elektromagnetna združljivost (EMC) – 6-2. del: Osnovni standardi – Odpornost za
industrijska okolja (IEC 61000-6-2:2005) (vsebuje popravek AC:2005)
Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for
industrial environments
Elektromagnetische Verträglichkeit (EMV) -- Teil 6-2: Fachgrundnormen - Störfestigkeit
für Industriebereiche
Compatibilité électromagnétique (CEM) -- Partie 6-2: Normes génériques - Immunité
pour les environnements industriels
Ta slovenski standard je istoveten z: EN 61000-6-2:2005
ICS:
33.100.20 Imunost Immunity
SIST EN 61000-6-2:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61000-6-2:2005

---------------------- Page: 2 ----------------------

SIST EN 61000-6-2:2005
EUROPEAN STANDARD EN 61000-6-2
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2005

ICS 33.100.20 Supersedes EN 61000-6-2:2001
Incorporates Corrigendum September 2005


English version


Electromagnetic compatibility (EMC)
Part 6-2: Generic standards –
Immunity for industrial environments
(IEC 61000-6-2:2005)


Compatibilité électromagnétique (CEM) Elektromagnetische Verträglichkeit (EMV)
Partie 6-2: Normes génériques – Teil 6-2: Fachgrundnormen –
Immunité pour les environnements Störfestigkeit für Industriebereiche
industriels (IEC 61000-6-2:2005)
(CEI 61000-6-2:2005)



This European Standard was approved by CENELEC on 2005-06-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 61000-6-2:2005 E

---------------------- Page: 3 ----------------------

SIST EN 61000-6-2:2005
EN 61000-6-2:2005 - 2 -
Foreword
The text of document 77/295/FDIS, future edition 2 of IEC 61000-6-2, prepared by IEC TC 77,
Electromagnetic compatibility, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 61000-6-2 on 2005-06-01.
This European Standard supersedes EN 61000-6-2:2001.

Specific technical changes have been introduced to Tables 1 to 4. The frequency range for tests
according to EN 61000-4-3 has been extended above 1 GHz according to technologies used in this
frequency area. The use of TEM waveguide testing according to EN 61000-4-20 has been introduced
for certain products and the testing requirements according to EN 61000-4-11 have been amended
significantly.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-03-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-06-01
This European Standard was prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and supports the essential requirements of
Directives 89/336/EEC and 1999/5/EC. See Annex ZZ.
Annexes ZA and ZZ have been added by CENELEC.
The contents of the corrigendum of September 2005 have been included in this copy.
__________
Endorsement notice
The text of the International Standard IEC 61000-6-2:2005 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 61000-4-1 NOTE Harmonized as EN 61000-4-1:2000 (not modified).
IEC 61000-4-20 NOTE Harmonized as EN 61000-4-20:2003 (not modified).
CISPR 11 NOTE Harmonized as EN 55011:1998 (modi
...