Abstract

This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment.
This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems.
The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or
voltage variations on DC input power ports.
This document defines:
– the range of test levels;
– the test generator;
– the test set-up;
– the test procedure.
The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6.
The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17.
This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.

Status
Published
Publication Date
10-Sep-2026
Current Stage
6060 - Document made available - Publishing
Start Date
11-Sep-2026
Due Date
31-Oct-2025
Completion Date
31-Oct-2025

Buy Documents

Standard

EN IEC 61000-4-29:2026 - BARVE

English language (27 pages)
Preview
Preview
e-Library read for
×1 day

EN IEC 61000-4-29:2026 is a CLC and IEC standard for EMC immunity testing on d.c. input power ports. It specifies how to test electrical and electronic equipment, systems, modules and subsystems for voltage dips, short interruptions and voltage variations on low-voltage DC networks, including the test levels, generator performance, test set-up, procedure and report content.

What does EN IEC 61000-4-29:2026 specify?

EN IEC 61000-4-29:2026 defines a common method for checking immunity at the d.c. input power port of electrical and electronic equipment. It is aimed at equipment connected to low-voltage DC networks external to the equipment, so users can compare test results from different laboratories on the same basis.

Clause 1 sets the scope and says the document covers the range of test levels, the test generator, the test set-up and the test procedure. It also states that ripple on the d.c. input power port is covered by IEC 61000-4-17, and that the standard is a general basic reference for IEC product committees, which decide what severity level and which tests fit their equipment.

AnnexWhat it covers
Annex AInformative examples of test generators and test set-up
Annex BNormative inrush current measurement
Annex CInformative description of the DC network

The document is organized into clauses for scope, references, terms, general considerations, test levels, test generator, test set-up, test procedure, evaluation of results and test report.

What are the key requirements of EN IEC 61000-4-29:2026?

Scope and reference voltage

EN IEC 61000-4-29:2026 applies to equipment and systems whose DC input power ports are intended for low voltage DC networks. It also applies to modules or subsystems when the EUT (Equipment Under Test, EUT) has a rated power above the test generator capacity given in Clause 6.

Clause 5 uses the rated voltage of the equipment as the reference for the test level. If the EUT has a rated voltage range, the standard gives a practical rule for choosing one reference voltage or for testing both limits of the range. In practice, this matters because the same product family may need different test conditions depending on its voltage window.

Preferred test levels and timing

Clause 5 points to three tables of preferred levels and durations: Table 1 for voltage dips, Table 2 for short interruptions, and Table 3 for voltage variations. Product standards may choose one or more combinations from those tables, and the text says the shortest duration should be tested because some equipment is sensitive even to brief events.

For short interruptions, the document distinguishes high impedance and low impedance conditions at the generator output. That matters because a short interruption can behave very differently depending on whether the source blocks reverse current or absorbs inrush current from the load.

Test generator performance

Clause 6 sets the generator characteristics. The generator must provide the intended dips, interruptions and variations without adding disturbances that affect the EUT, and its output voltage range can go up to 120% of the maximum rated output voltage.

The standard also sets performance targets for practical testing: output voltage tolerance, low ripple, fast rise and fall times, limited overshoot and undershoot, and enough steady-state current capability for the EUT. For short interruptions, the generator must work in either low impedance or high impedance mode; for dips and voltage variations, it operates in low impedance mode.

Clause 6.2.3 requires a high output impedance of at least 100 kΩ during a short interruption, measured up to 1.2 times Uo and not above 1100 V. In practice, this is what lets the test reproduce the intended interruption without unwanted current flow.

Verification of the generator

Clause 6.3 requires verification of generator characteristics with measurement uncertainty better than ±2%. It includes checks of output voltage in no-load and load conditions, switching characteristics with a 100 Ω resistive load, peak inrush current drive capability, output impedance and test level duration.

Annex B supports this by defining how to measure peak inrush current drive capability and, when needed, the EUT peak inrush current. This matters when the generator is not strong enough for all loads, because the EUT inrush current must stay within the allowed margin if a reduced-capability generator is used.

Test set-up, procedure, results and report

Clause 7 says to use the shortest power supply cable specified by the EUT operating instructions, or the shortest possible suitable cable if no length is specified. Clause 8 requires the EUT to run in normal operating conditions, under a test plan that records the selected levels, durations, operating modes and auxiliary equipment.

The procedure includes laboratory reference conditions, three repeated dips or interruptions with at least 10 s between events, and three repeated voltage variations at 10 s intervals. The laboratory conditions must support correct operation of the EUT, and the output voltage of the generator must be monitored with accuracy better than ±2%.

Clause 9 classifies results from normal operation through temporary loss of function to unrecoverable damage or data loss. Clause 10 requires the report to contain the tests carried out, the identification of the EUT and test equipment, environmental conditions, performance criteria, observed effects, the pass/fail rationale and any special use conditions such as cable length, shielding or grounding.

What terms does EN IEC 61000-4-29:2026 define?

  • Immunity - the ability of a device, equipment or system to keep working without degradation when an electromagnetic disturbance is present.
  • Voltage dip - a sudden reduction of voltage in a low voltage DC distribution system, followed by recovery after a short time.
  • Short interruption - a supply voltage drop below 20% of nominal voltage for a period that typically does not exceed 1 min.
  • Voltage variation - a gradual change of supply voltage down from rated voltage and then back up again.
  • Malfunction - the loss of intended function, or the execution of unintended functions by the equipment.
  • DC - Direct Current.
  • EUT - Equipment Under Test.

Who uses EN IEC 61000-4-29:2026?

EN IEC 61000-4-29:2026 is used by IEC product committees, test laboratories, manufacturers and EMC engineers who need a repeatable immunity test for DC-powered equipment. It is especially relevant for equipment and systems connected to low voltage DC networks, including industrial DC network applications described in Annex C.

Quality and procurement teams use it when they need to specify which test levels, durations and performance criteria apply to a product. Design teams use it to choose power input architectures, verify generator compatibility and define pass/fail criteria before formal testing.

What changed in EN IEC 61000-4-29:2026 from the previous edition?

EN IEC 61000-4-29:2026 is the second edition and it replaces the first edition published in 2000. The foreword lists these main technical changes:

  • higher test generator output voltage to reflect newer DC network voltages
  • tolerances added for the duration of voltage changes
  • current limiting for short interruptions in low impedance condition
  • broader technical clarification of generator specifications and their verification
  • clarification of the loads used for switching characteristics and peak inrush current drive capability
  • clarification of evaluation of test results and test reports
  • description of the DC environment

Which standards are used with EN IEC 61000-4-29:2026?

The document points readers to these related standards and publications:

StandardContribution
IEC 61000-4-17Covers ripple on d.c. input power ports, which is outside the scope of this part
IEC 61000-4-11Gives a similar circuit for inrush-current measurement
IEC 60038:2021Provides standard voltages
IEC 60050(161)Provides EMC terminology used for definitions
IEC SRD 63317:2025Describes LVDC industry applications and the industrial DC network context

What does the EN IEC 61000-4-29:2026 document contain?

EN IEC 61000-4-29:2026 contains preferred test levels in Tables 1 to 3, generator performance requirements in Clause 6, and procedures for verifying output voltage, switching characteristics, inrush current drive capability, output impedance and duration accuracy. It also includes figures for example dips, interruptions and voltage variations, plus generator examples in Annex A and measurement circuits in Annex B.

For practice, that means the document gives users the concrete test set-up and measurement approach needed to reproduce immunity testing in the laboratory, document the results and compare them against product-specific acceptance criteria.

Relations

Effective Date
23-Jan-2023
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026

Buy Documents

Standard

EN IEC 61000-4-29:2026 - BARVE

English language (27 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

EN IEC 61000-4-29:2026 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests". This standard covers: This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports. This document defines: – the range of test levels; – the test generator; – the test set-up; – the test procedure. The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17. This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.

This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports. This document defines: – the range of test levels; – the test generator; – the test set-up; – the test procedure. The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17. This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.

EN IEC 61000-4-29:2026 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN IEC 61000-4-29:2026 has the following relationships with other standards: It is inter standard links to EN 61000-4-29:2000, EN 1776:2015, EN 61000-6-7:2015, EN 12405-1:2005+A2:2010, EN 62488-2:2017, EN 12405-1:2018, EN IEC 62984-1:2020, EN 13611:2007+A2:2011, EN 60987:2009, CLC/TS 50729:2025, EN IEC 60143-4:2024, EN IEC 62003:2020, EN 267:2020, EN 62271-1:2017, EN 1776:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN IEC 61000-4-29:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN IEC 61000-4-29:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviated terms
  • 3.1 Terms and definitions
  • 3.1.1 immunity (to a disturbance)
  • 3.1.2 voltage dip
  • 3.1.3 short interruption
  • 3.1.4 voltage variation
  • 3.1.5 malfunction
  • 3.2 Abbreviated terms
  • 4 General
  • 5 Test levels
  • 6 Test generator
  • 6.1 General
  • 6.2 Characteristics and performances of the generator
  • 6.3 Verification of the characteristics of the generator
  • 7 Test set-up
  • 8 Test procedure
  • 8.1 General
  • 8.2 Laboratory reference conditions
  • 8.3 Execution of the test
  • 9 Evaluation of test results
  • 10 Test report
  • Annex A
  • Annex B
  • Annex C
  • Bibliography

INTRODUCTION IEC 61000 is published in separate parts according to the following structure:

Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as international standards or as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-6-1).

This part is an international standard which gives immunity requirements for testing DC equipment and systems with voltage dips, interruptions and variations on the DC input power port.

SIST EN IEC 61000-4-29:2026

1 Scope

This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports.

This document defines:

  • the range of test levels;
  • the test generator;
  • the test set-up;
  • the test procedure.

The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17.

This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.

2 Normative references

There are no normative references in this document.

3 Terms, definitions and abbreviated terms

3.1 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

3.1.1 immunity (to a disturbance)

ability of a device, equipment or system to perform without degradation in the presence of an electromagnetic disturbance [SOURCE: IEC 60050-161:1990, 161-01-20]

SIST EN IEC 61000-4-29:2026

3.1.2 voltage dip

sudden reduction of the voltage at a point in the low voltage DC distribution system, followed by voltage recovery after a short period of time, from a few milliseconds up to a few seconds

3.1.3 short interruption

change of the supply voltage at a point of the low voltage DC distributed system below 20 % of the nominal voltage for a time interval which typically does not exceed 1 min Note 1 to entry: A short interruption does not necessarily result in a complete disappearance of the supply voltage.

3.1.4 voltage variation

gradual change of the supply voltage from the rated voltage to a lower voltage or from the rated voltage to a higher voltage

3.1.5 malfunction

termination of the ability of an equipment to carry out intended functions, or the execution of unintended functions by the equipment

3.2 Abbreviated terms

DC Direct current ESR Equivalent series resistance EUT Equipment under test LVDC Low-voltage direct current

4 General

The operation of electrical or electronic equipment can be affected by voltage dips, short interruptions or voltage variations of the power supply.

Voltage dips and short interruptions are mainly caused by faults in the DC distribution system, or by sudden large changes of load. Two or more consecutive dips or interruptions can also occur.

Faults in the DC distribution system can inject transient overvoltages into the distribution network; this particular phenomenon is not covered by this document. Voltage interruptions are primarily caused by the switching of mechanical relays when changing from one source to another (e.g. from generator set to battery). During a short interruption, the DC supply network can present either a "high impedance" or "low impedance" condition. The first condition can be due to switching from one source to another; the second condition can be due to the clearing of an overload or fault condition on the supply bus. The latter can cause reverse current (negative peak inrush current) from the load.

These phenomena are random in nature and can be characterised in terms of their duration and the deviation from the nominal voltage. Voltage dips and short interruptions are not always abrupt.

The primary cause of voltage variations is the discharging and recharging of battery systems; however, they are also created when there are significant changes to the load condition of the DC network.

SIST EN IEC 61000-4-29:2026

5 Test levels

The rated voltage for the equipment (U ) shall be used as a reference for the specification of T the voltage test level.

If the EUT has a rated voltage range, the rated voltage U to be used as reference voltage shall T be determined as follows:

  • if the upper limit of the voltage range does not exceed by more than 20 % the lower limit of the voltage range, a single voltage within the voltage range may be used as rated voltage U ; T
  • in all other cases, the test procedure shall be applied for both the lower and upper limits of the rated voltage range.

The preferred voltage test levels (in % of U ) and durations are given in Table 1, Table 2 and T Table 3 as follows:

- Table 1 corresponding to voltage dips; - Table 2 corresponding to short voltage interruptions; - Table 3 corresponding to voltage variations; The change of the voltage for dips and interruptions is abrupt, in the range of microseconds (see the test generator specifications in Clause 6, Figure 1 and Figure 2). The test conditions of high impedance (see 6.2.3) and low impedance (see 6.2.2) reported in Table 2 refer to the output impedance of the test generator as seen by the EUT during the voltage interruption.

Table 1 – Preferred test levels and durations for voltage dips Test Test level Duration % U s T 0,01 0,03 40 and 70 0,1 Voltage dips or 0,3

SIST EN IEC 61000-4-29:2026

Table 2 – Preferred test levels and durations for short voltage interruptions Test Test condition Test level Duration % U s T 0,001 0,003 0,01 High impedance 0,03 Short interruptions or 0 0,1 low impedance, 0,3

NOTE For certain types of equipment it is appropriate to repeat the test in high impedance and low impedance condition.

Table 3 – Preferred test levels and durations for voltage variations Test Test level Duration % U s T 0,1 85 and 120 0,3 or

Voltage variations 80 and 120

or

The decrease and increase time (see Figure 3) shall be specified by the product standard based on the specific application.

Product standards may choose from each table one or more of the test levels and associated durations. In each table, “x” is an open value that may be chosen to test a special application. The EUT can be sensitive to voltage changes of any duration specified in the tables. In particular, the shortest duration should be tested.

If the EUT is immune to short interruptions in low impedance condition of a specific duration, it is unnecessary to test for other test levels of the same duration (e.g. 40 % or 70 % U ). T

SIST EN IEC 61000-4-29:2026

Key t fall time of the voltage change f t rise time of the voltage change r t time at the reduced voltage s NOTE The percentage values refer to the amplitude of the voltage dip. Figure 1 – Example of voltage dip

SIST EN IEC 61000-4-29:2026

Key t fall time of the voltage change f t rise time of the voltage change r t time at 0 % s NOTE The percentage values refer to the amplitude of the voltage interruption. Figure 2 – Example of short voltage interruption

SIST EN IEC 61000-4-29:2026

Key t time for increasing voltage

t time for decreasing voltage d t time at increased voltage

t time at reduced voltage s NOTE The percentage values refer to the rated voltage U .

T Figure 3 – Examples of voltage variations

6 Test generator

6.1 General

The following features are common to the generator for voltage dips, short interruptions and voltage variations, except where otherwise indicated.

Apart from the generation of the intended dips and interruptions, the test generator shall not emit disturbances which can influence the performance of the EUT. Examples of generators are given in Figure A.1 (test generator based on two power sources with switches) and Figure A.2 (test generator based on a single programmable power source).

SIST EN IEC 61000-4-29:2026

6.2 Characteristics and performances of the generator

6.2.1 General

The test generator shall be able to operate in continuous mode with the following main specifications:

  • Output voltage range (U ): up to 120 % of the maximum U o T
  • Short interruptions, dips, and variations of the as given in Table 1, Table 2 and Table 3 output voltage:

...