Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables

EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40); • 0,6/1 kV screened or unscreened (1,5 mm² to 50 mm², 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.

Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2-2: Leitungen mit vernetzter elastomerer Isolierung - Mehr- und vieladrige Leitungen

EN 50264-2-2 legt Anforderungen an und Aufbauten und Abmessungen von mehr- und vieladrigen Leitungen für folgende Bauarten und Nennspannungen fest: • 300 V/500 V mit oder ohne Schirm (1 mm², 1,5 mm² und 2,5 mm², Aderzahlen von 2 bis 40); • 0,6 kV/1 kV mit oder ohne Schirm (1,5 mm² bis 50 mm², 2, 3 und 4 Adern). ANMERKUNG Nicht alle Leiterquerschnitte oder Aderzahlen sind für jede Bauart festgelegt. Alle Leitungen haben einen verzinnten Kupferleiter Klasse 5 nach EN 60228, eine halogenfreie Isolierung und gegebenenfalls einen halogenfreien Mantel. Sie sind für feste Verlegung im Schienenfahrzeug bestimmt oder für Verdrahtungen, bei denen im Betrieb begrenzt mit Bewegungen gerechnet werden muss. Die Anforderungen berücksichtigen eine dauernde Leitertemperatur von nicht mehr als 90 °C und eine maximale Kurzschlusstemperatur von 200 °C bei einer Dauer von 5 Sekunden. Unter Brandbedingungen zeigen die Leitungen besondere Leistungsmerkmale hinsichtlich der maximal zulässigen Weiterleitung der Flammen (Ausbreitung der Flammen) und der höchsten zulässigen Emission von Rauch und giftigen Gasen. EN 50264-2-2 sollte in Verbindung mit Teil 1 „Allgemeine Anforderungen“ gelesen werden.

Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu spécifié pour matériel roulant ferroviaire - Partie 2-2: Câbles à enveloppe isolante réticulée - Câbles multiconducteurs

La EN 50264-2-2 spécifie les prescriptions, la construction et les dimensions des câbles multiconducteurs des types et tensions assignées suivants: • 300/500 V avec ou sans blindage (de 1 mm², 1,5 mm² et 2,5 mm²; de 2 à 40 conducteurs); • 0,6/1 kV avec ou sans blindage (de 1,5 mm² à 50 mm²; de 2, 3 et 4 conducteurs). NOTE Les combinaisons des sections et des nombres de conducteurs ne sont pas toutes spécifiées pour chaque type. Tous les câbles possèdent une âme en cuivre étamé de classe 5 selon la EN 60228, une enveloppe isolante et une gaine sans halogènes. Ils sont destinés aux installations fixes ou soumis à de faibles flexions en service des matériels roulants ferroviaires. Les prescriptions sont basées pour une température permanente de l’âme ne dépassant pas 90 °C et à une température maximale de 200 °C pour une durée de 5 s en cas de court-circuit. Les câbles présentent, en cas d’incendie, des performances particulières de propagation maximale admissible de la flamme (longueur brûlée) et d’émission de fumées et de gaz toxiques. Il est recommandé de lire la EN 50264-2-2 conjointement avec la Partie 1 "Prescriptions générales".

Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki imajo posebne ognjevarne lastnosti - 2-2. del: Kabli z zamreženo elastomerno izolacijo - Večžilni kabli

General Information

Status
Published
Publication Date
26-Jun-2008
Withdrawal Date
28-Feb-2011
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
29-Sep-2021

Relations

Buy Standard

Standard
EN 50264-2-2:2008
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2008
1DGRPHãþD
SIST EN 50264-3:2003
äHOH]QLãNHQDSUDYH(QHUJHWVNLLQNUPLOQLNDEOL]DåHOH]QLãNDYR]QDVUHGVWYDNL
LPDMRSRVHEQHRJQMHYDUQHODVWQRVWLGHO.DEOL]]DPUHåHQRHODVWRPHUQR
L]RODFLMR9HþåLOQLNDEOL
Railway applications - Railway rolling stock power and control cables having special fire
performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall -- Teil 2-2: Leitungen mit vernetzter elastomerer
Isolierung - Mehr- und vieladrige Leitungen
Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu
spécifié pour matériel roulant ferroviaire -- Partie 2-2: Câbles à enveloppe isolante
réticulée - Câbles multiconducteurs
Ta slovenski standard je istoveten z: EN 50264-2-2:2008
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50264-2-2
NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM
ICS 13.220.20; 29.060.20; 45.060.01 Supersedes EN 50264-3:2002

English version
Railway applications -
Railway rolling stock power and control cables
having special fire performance -
Part 2-2: Cables with crosslinked elastomeric insulation -
Multicore cables
Applications ferroviaires - Bahnanwendungen -
Câbles de puissance et de contrôle Starkstrom- und Steuerleitungen
à comportement au feu spécifié für Schienenfahrzeuge mit verbessertem
pour matériel roulant ferroviaire - Verhalten im Brandfall -
Partie 2-2: Câbles à enveloppe Teil 2-2: Leitungen mit vernetzter
isolante réticulée - elastomerer Isolierung -
Câbles multiconducteurs Mehr- und vieladrige Leitungen

This European Standard was approved by CENELEC on 2008-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50264-2-2:2008 E
Foreword
This European Standard was prepared by Working Group 12, Railway cables, of the Technical Committee
CENELEC TC 20, Electric cables, as part of the overall programme of work in the Technical Committee
CENELEC TC 9X, Electrical and electronic applications for railways.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50264-2-2 on
2008-03-01.
This European Standard supersedes EN 50264-3:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-03-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-03-01
__________
– 3 – EN 50264-2-2:2008
Contents
Page
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Definitions . 7
4 Rated voltage . 7
5 Marking and identification . 7
5.1 Marking of cable . 7
5.2 Core identification. 8
5.3 Sheath . 8
6 Construction of cables . 8
6.1 General . 8
6.2 Conductor . 8
6.3 Insulation system. 9
6.4 Laying up of cores and fillers . 9
6.5 Metallic screen . 9
6.6 Sheath . 9
6.7 Construction . 10
7 Tests . 18
7.1 Definitions relating to tests . 18
7.2 Conductor resistance. . 18
7.3 Voltage test . 18
7.4 Insulation resistance . 19
7.5 Dielectric strength on sample . 19
7.6 Spark test . 19
7.7 Surface resistance. 20
7.8 Ageing test . 20
7.9 Hot set test . 20
7.10 Compatibility . 20
7.11 Water absorption of sheath . 21
7.12 Ozone resistance . 21
7.13 Mineral oil resistance . 21
7.14 Fuel resistance . 22
7.15 Acid and alkali resistance . 22
7.16 Bending test at low temperature (cores or cables with OD ≤ 12,5 mm) . 23
7.17 Cold elongation test (cores or cables with OD > 12,5 mm) . 23
7.18 Impact test at low temperature . 23
7.19 Reaction to fire – Cable . 23
7.20 Reaction to fire – Components . 23
Annex A (normative) Code designation . 27
Bibliography . 28

Tables
Table 1 – Multicore cables – unscreened (300/500 V) . 11
Table 2 – Multicore cables – screened (300/500 V) . 13
Table 3 – Dimensions of core (0,6/1 kV) . 15
Table 4 – Two cores – (0,6/1 kV) unscreened. 15
Table 5 – Two cores – (0,6/1 kV) screened. 16
Table 6 – Three cores – (0,6/1 kV) unscreened . 16
Table 7 – Three cores – (0,6/1 kV) screened . 17
Table 8 – Four cores – (0,6/1 kV) unscreened . 17
Table 9 – Four cores – (0,6/1 kV) screened . 18
Table 10 – Schedule of tests for cables . 24

– 5 – EN 50264-2-2:2008
Introduction
The EN 50264 series covers a range of cables, based upon halogen free materials, for use in railway rolling
stock. It is divided into 5 parts under the generic title “Railway applications - Railway rolling stock power and
control cables having special fire performance”:
– Part 1 General requirements;
– Part 2-1 Cables with crosslinked elastomeric insulation – Single core cables;
– Part 2-2 Cables with crosslinked elastomeric insulation – Multicore cables;
– Part 3-1 Cables with crosslinked elastomeric insulation with reduced dimensions – Single core
cables;
– Part 3-2 Cables with crosslinked elastomeric insulation with reduced dimensions – Multicore cables.
Information regarding selection and installation of cables, including current ratings can be found in EN 50355
and EN 50343. The procedure for selection of cable cross-sectional area, including reduction factors for
ambient temperature and installation type, is described in EN 50343.
Special test methods referred to in EN 50264 are given in EN 50305.
Part 1, “General requirements”, contains a more extensive introduction to EN 50264, and should be read in
conjunction with this Part 2-2.

1 Scope
EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the
following types and voltage ratings:
• 300/500 V screened or unscreened (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40);
• 0,6/1 kV screened or unscreened (1,5 mm² to 50 mm², 2, 3 and 4 cores).
NOTE  Not all conductor sizes or number of cores are specified for every type.
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free
sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is
encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a
maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.
EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.
2 Normative references
The following referenced documents are indispensable for the application
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.