Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables

EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); • 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2-1: Leitungen mit vernetzter elastomerer Isolierung - Einadrige Leitungen

EN 50264-2-1 legt Anforderungen an und Aufbauten und Abmessungen von einadrigen Leitungen für folgende Bauarten und Nennspannungen fest: • 0,6/1 kV ohne Schirm, ohne Mantel (1 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, ohne Mantel (1,5 mm² bis 400 mm²); • 1,8/3 kV ohne Schirm, mit Mantel (1,5 mm² bis 400 mm²); • 3,6/6 kV ohne Schirm, mit Mantel (2,5 mm² bis 400 mm²). Alle Leitungen haben einen verzinnten Kupferleiter Klasse 5 nach EN 60228, eine halogenfreie Isolierung und gegebenenfalls einen halogenfreien Mantel. Sie sind für feste Verlegung im Schienenfahrzeug bestimmt oder für Verdrahtungen, bei denen im Betrieb begrenzt mit Bewegungen gerechnet werden muss. Die Anforderungen berücksichtigen eine dauernde Leitertemperatur von nicht mehr als 90 °C und eine maximale Kurzschlusstemperatur von 200 °C bei einer Dauer von 5 s. Unter Brandbedingungen zeigen die Leitungen besondere Leistungsmerkmale hinsichtlich der maximal zulässigen Weiterleitung der Flammen (Ausbreitung der Flammen) und der höchsten zulässigen Emission von Rauch und giftigen Gasen. EN 50264-2-1 sollte in Verbindung mit Teil 1 „Allgemeine Anforderungen“ gelesen werden.

Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu spécifié pour matériel roulant ferroviaire - Partie 2-1: Câbles à enveloppe isolante réticulée - Câbles monoconducteurs

La EN 50264-2-1 spécifie les prescriptions, les constructions et les dimensions des câbles monoconducteurs des types et tensions assignées suivants: • 0,6/1 kV sans blindage ni gaine (de 1 mm² à 400 mm²); • 1,8/3 kV sans blindage ni gaine (de 1,5 mm² à 400 mm²); • 1,8/3 kV gainé sans blindage (de 1,5 mm² à 400 mm²); • 3,6/6 kV gainé sans blindage (de 2,5 mm² à 400 mm²). Tous les câbles monoconducteurs possèdent une âme en cuivre étamé de classe 5 selon la EN 60228, une isolation et une gaine sans halogènes. Ils sont destinés aux installations fixes ou soumis à de faibles flexions en service des matériels roulants ferroviaires. Les prescriptions sont basées pour une température permanente à l’âme ne dépassant pas 90 °C et à une température maximale de 200 °C pour une durée de 5 s en cas de court-circuit. Les câbles monoconducteurs présentent, en cas d’incendie, des performances particulières de propagation maximale admissible de la flamme (longueur brûlée) et d’émission de fumées et de gaz toxiques. Il est recommandé de lire la EN 50264-2-1 conjointement avec la Partie 1 “Prescriptions générales”.

Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno izolacijo - Enožilni kabli

General Information

Status
Published
Publication Date
26-Jun-2008
Withdrawal Date
28-Feb-2011
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
29-Sep-2021
Completion Date
23-Sep-2025

Relations

Overview

EN 50264-2-1:2008 specifies requirements, constructions and dimensions for single-core power and control cables with crosslinked elastomeric insulation for railway rolling stock. Part of the EN 50264 series, this CENELEC standard covers halogen‑free insulated and sheathed single‑core cables designed for improved fire performance (limited flame propagation, low smoke and toxic gas emission) used as fixed wiring or where only limited flexing occurs.

Key facts:

  • Title: Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2‑1: Cables with crosslinked elastomeric insulation - Single core cables (EN 50264-2-1:2008)
  • Conductors: Class 5 tinned copper (EN 60228)
  • Materials: Halogen‑free insulation and sheath
  • Continuous conductor temperature: ≤ 90 °C
  • Short‑circuit max temperature: 200 °C (based on 5 s duration)

Key topics and requirements

  • Voltage ratings & conductor sizes
    • 0.6/1 kV unsheathed: 1 mm² to 400 mm²
    • 1.8/3 kV unsheathed: 1.5 mm² to 400 mm²
    • 1.8/3 kV sheathed: 1.5 mm² to 400 mm²
    • 3.6/6 kV sheathed: 2.5 mm² to 400 mm²
  • Fire performance
    • Limits on flame propagation (flame spread)
    • Limits on smoke density and toxic gas emission (reaction‑to‑fire requirements per referenced test standards)
  • Construction & marking
    • Tinned, annealed copper conductors (class 5)
    • Black core insulation and sheath by default (other colours per HD 308 if specified)
    • Mandatory marking: manufacturer, EN reference, voltage rating, conductor size and code designation (Annex A)
  • Mechanical & material tests
    • Tests for conductor resistance, voltage, insulation resistance, dielectric strength, ageing, low temperature bending/impact, ozone, oil/fuel/chemical resistance, and reaction‑to‑fire
  • Temperature limits and testing
    • Continuous and short‑circuit temperatures specified; conformity verified by inspection and test schedule in the standard

Applications and users

Who uses EN 50264-2-1:

  • Cable manufacturers designing and certifying single‑core railway cables
  • Rolling stock designers and OEMs specifying fixed wiring and power/control cabling
  • Procurement and compliance teams ensuring cables meet fire‑safety and electrical requirements
  • Test laboratories performing electrical, mechanical and fire tests
  • Maintenance and installation engineers selecting suitable halogen‑free cables for passenger and freight vehicles

Practical uses:

  • Fixed wiring in trains, trams and metros
  • Limited‑flex harness runs and feeder lines in rolling stock
  • Building blocks for multicore sheathed assemblies (used in conjunction with Part 2‑2)

Related standards

  • EN 50264‑1:2008 - General requirements (read in conjunction)
  • EN 50264‑2‑2 - Multicore cables with crosslinked elastomeric insulation
  • EN 50305 - Special test methods referenced by EN 50264
  • EN 50355, EN 50343 - Cable selection and installation guidance
  • EN 60228 - Conductors of insulated cables
  • EN 60332‑1‑2, EN 50266, EN 61034‑2 - Fire and smoke test methods

Keywords: EN 50264-2-1, railway rolling stock cables, crosslinked elastomeric insulation, single core cables, halogen‑free, fire performance, tinned copper conductors, voltage ratings, cable testing.

Standard
EN 50264-2-1:2008
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 50264-2-1:2008 is a standard published by CLC. Its full title is "Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables". This standard covers: EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); • 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); • 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

EN 50264-2-1:2008 is classified under the following ICS (International Classification for Standards) categories: 13.220.20 - Fire protection; 29.060.20 - Cables; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50264-2-1:2008 has the following relationships with other standards: It is inter standard links to EN 50264-2:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 50264-2-1:2008 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2008
1DGRPHãþD
SIST EN 50264-2:2003
Železniške naprave - Energetski in krmilni kabli za železniška vozna sredstva, ki
imajo posebne ognjevarne lastnosti - 2-1. del: Kabli z zamreženo elastomerno
izolacijo - Enožilni kabli
Railway applications - Railway rolling stock power and control cables having special fire
performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core
cables
Bahnanwendungen - Starkstrom- und Steuerleitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall -- Teil 2-1: Leitungen mit vernetzter elastomerer
Isolierung - Einadrige Leitungen
Applications ferroviaires - Câbles de puissance et de contrôle à comportement au feu
spécifié pour matériel roulant ferroviaire -- Partie 2-1: Câbles à enveloppe isolante
réticulée - Câbles monoconducteurs
Ta slovenski standard je istoveten z: EN 50264-2-1:2008
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50264-2-1
NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM
ICS 13.220.20; 29.060.20; 45.060.01 Supersedes EN 50264-2:2002

English version
Railway applications -
Railway rolling stock power and control cables
having special fire performance -
Part 2-1: Cables with crosslinked elastomeric insulation -
Single core cables
Applications ferroviaires - Bahnanwendungen -
Câbles de puissance et de contrôle Starkstrom- und Steuerleitungen
à comportement au feu spécifié für Schienenfahrzeuge
pour matériel roulant ferroviaire - mit verbessertem Verhalten im Brandfall -
Partie 2-1: Câbles à enveloppe Teil 2-1: Leitungen mit vernetzter
isolante réticulée - elastomerer Isolierung -
Câbles monoconducteurs Einadrige Leitungen

This European Standard was approved by CENELEC on 2008-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50264-2-1:2008 E
Foreword
This European Standard was prepared by Working Group 12, Railway cables, of the Technical Committee
CENELEC TC 20, Electric cables, as part of the overall programme of work in the Technical Committee
CENELEC TC 9X, Electrical and electronic applications for railways.
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50264-2-1 on
2008-03-01.
This European Standard supersedes EN 50264-2:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2009-03-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2011-03-01
with the EN have to be withdrawn
__________
– 3 – EN 50264-2-1:2008
Contents
Page
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Definitions . 7
4 Rated voltage . 7
5 Marking and identification . 7
5.1 Marking of cable . 7
5.2 Core identification. 8
5.3 Sheath . 8
6 Construction of cables . 8
6.1 General . 8
6.2 Conductor . 8
6.3 Conductor screening . 8
6.4 Separator . 8
6.5 Insulation system. 8
6.6 Sheath . 9
6.7 Constructional components . 9
7 Tests . 15
7.1 Definitions relating to tests . 15
7.2 Conductor resistance . 15
7.3 Voltage test . 15
7.4 Insulation resistance . 15
7.5 Dielectric strength. 15
7.6 Spark test . 16
7.7 DC stability . 16
7.8 Surface resistance. 16
7.9 Ageing test . 16
7.10 Hot set test . 17
7.11 Compatibility . 17
7.12 Water absorption on sheath . 17
7.13 Ozone resistance . 17
7.14 Mineral oil resistance . 18
7.15 Fuel resistance . 18
7.16 Acid and alkali resistance . 19
7.17 Bending test at low temperature (cables with OD ≤ 12,5 mm) . 19
7.18 Cold elongation test (cables with OD > 12,5 mm) . 19
7.19 Impact test at low temperature . 20
7.20 Reaction to fire – Cable . 20
7.21 Reaction to fire – Components . 20
Annex A (normative) Code designation . 24
Bibliography . 25

Tables
Table 1 – General data – Cable type (0,6/1 kV unsheathed) . 11
Table 2 – General data – Cable type (1,8/3 kV unsheathed) . 12
Table 3 – General data – Cable type (1,8/3 kV sheathed) . 13
Table 4 – General data – Cable type (3,6/6 kV sheathed) . 14
Table 5 – Schedule of tests for cables . 21

– 5 – EN 50264-2-1:2008
Introduction
The EN 50264 series covers a range of cables, based upon halogen free materials, for use in railway rolling
stock. It is divided into 5 parts under the generic title “Railway applications - Railway rolling stock power and
control cables having special fire performance”:
– Part 1 General requirements;
– Part 2-1 Cables with crosslinked elastomeric insulation – Single core cables;
– Part 2-2 Cables with crosslinked elastomeric insulation – Multicore cables;
– Part 3-1 Cables with crosslinked elastomeric insulation with reduced dimensions – Single core
cables;
– Part 3-2 Cables with crosslinked elastomeric insulation with reduced dimensions – Multicore cables.
Information regarding selection and installation of cables, including current ratings can be found in EN 50355
and EN 50343. The procedure for selection of cable cross-sectional area, including reduction factors for
ambient temperature and installation type, is described in EN 50343.
Special test methods referred to in EN 50264 are given in EN 50305.
The cables in EN 50264-2-1 may also be used in EN 50264-2-2 to build up multicore sheathed cables.
Part 1, “General requirements”, contains a more extensive introduction to EN 50264, and should be read in
conjunction with this Part 2-1.

1 Scope
EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the
following types and voltage ratings:
• 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²);
• 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²);
• 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²);
• 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²).
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free
sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is
encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a
maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.
EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 10002-1 Metallic materials – Tensile testing – Methods of test at ambient temperature
EN 50264-1:2008 Railway applications – Railway rolling stock power and control cables having
special fire performance – Part 1: General requirements
EN 50266-2-4 Common test methods for cables under fire conditions – Test for vertical flame
spread of vertically-mounted bunched wires or cables –
Part 2-4: Procedures – Category C
EN 50266-2-5 Common test methods for cables under fire conditions – Test for vertical flame
spread of vertically-mounted bunched wires or cables –
Part 2-5: Procedures – Small cables – Category D
EN 50305:2002 Railway applications – Railway rolling stock cables having special fire performance
– Test methods
EN 60228 Conductors of insulated cables (IEC 60228)
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions –
Part 1-2: Test for vertical flame propagation for a single insulated wire or cable –
Procedure for 1 kW pre-mixed flame (IEC 60332-1-2)
EN 60811-1-1:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-1: General application – Measurement of thickness and overall
dimensions – Tests for determining the mechanical properties
(IEC 60811-1-1:1993)
– 7 – EN 50264-2-1:2008
EN 60811-1-2:1995 Insulating and sheathing materials of electric cables – Common test methods –
Part 1-2: General application – Thermal ageing methods
(IEC 60811-1-2:1985 + A1:1989 + corr. May 1986)
EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-3: General application – Methods for determining the density –
Water absorption tests – Shrinkage test (IEC 60811-1-3:1993)
EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 1-4: General application – Tests at low temperature
(IEC 60811-1-4:1985 + A1:1993 + corr. May 1986)
EN 60811-2-1:1998 Insulating and sheathing materials of electric and optical cables – Common test
methods – Part 2-1: Methods specific to elastomeric compounds – Ozone
resistance, hot set and mineral oil immersion tests
(IEC 60811-2-1:1998)
EN 61034-2 Measurement of smoke density of cables burning under defined conditions –
Part 2: Procedure and requirements (IEC 61034-2)
HD 308 Identification of cores in cables and flexible cords
3 Definitions
For the purposes of this document, the terms and definitions given in EN 50264-1 apply.
4 Rated voltage
The rated voltage for single-core insulated cables shall be as follows:
a) unsheathed: 0,6/1 kV; 1,8/3 kV;
b) sheathed: 1,8/3 kV; 3,6/6 kV.
5 Marking and identification
5.1 Marking of cable
Cables shall be marked with the following:
• manufacturer’s name;
• EN reference;
• voltage rating (U );
o
• conductor size;
• a code designation according to Annex A.
An example of a complete mark is:
XYZ  EN 50264-2-1  1800 V  400  FF
The marking shall conform to the requirements of EN 50264-1, Clause 5.

5.2 Core identification
The core insulation of all cables shall be black unless otherwise specified. If a colour other than black is
specified it shall be a colour in accordance with HD 308. The colour shall be on the surface or throughout the
insulation.
The colour shall be clearly identifiable and durable. Durability shall be checked by the test given in
EN 50305, 10.1.
Conformity with these requirements shall be verified by visual examination.
5.3 Sheath
The sheath shall be black unless otherwise specified.
6 Construction of cables
6.1 General
The cable shall conform to the applicable general requirements given in EN 50264-1 and to the specific
requirements of this part.
Conformity with the requirements shall be checked by inspection and by the tests given in Table 5.
The cable dimensions shall be as given in Tables 1 to 4 as appropriate to the cable type.
6.2 Conductor
Conductors shall be tin-coated annealed copper, class 5, according to EN 60228.
When tested in accordance with EN 10002-1 the minimum average elongation of the wires from the
conductor shall be 15 %, with a minimum value of 10 % for any individual wire.
NOTE It is not necessary to test every individual wire. 5 % of wires or 10 wires, whichever is the least number, should be selected at
random.
6.3 Conductor screening
For cables in Table 4 conductor screening shall be as given in EN 50264-1, 6.1.6.
6.4 Separator
6.4.1 A separator may be used over the conductor if the cable construction does not include a conductor
screen.
6.4.2 A separator may be included between the insulation and the sheath.
6.5 Insulation system
The insulation shall be one or more extruded materials as defined in EN 50264-1 applied so as to meet the
requirements of EI 101 to EI 105.

– 9 – EN 50264-2-1:2008
For single-core unsheathed and sheathed cable:
EI 101 low temperature resistant, oil resistant;
EI 102 extra low temperature resistant, oil resistant;
EI 103 low temperature resistant, extra oil and fuel resistant;
EI 104 extra low temperature resistant, extra oil and fuel resistant.
For sheathed cables:
EI 105 extra low temperature resistant, non oil resistant.
EI 105 may be used as the inner layer of a multilayer insulation system.
To claim extra low temperature performance both insulation and sheath shall be extra low temperature
resistant.
The insulation shall be applied to meet the requirements of EN 50264-1, 6.2.
The insulation thickness shall conform to the specified value g
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

The EN 50264-2-1:2008 standard provides comprehensive guidelines for the specification of single core cables utilized in railway applications, specifically focusing on those designed for power and control with enhanced fire performance characteristics. This standard outlines critical aspects such as cable construction, dimensions, and performance requirements for various voltage ratings, including 0.6/1 kV and 1.8/3 kV configurations. One of the key strengths of EN 50264-2-1 is its emphasis on safety under fire conditions. The requirement for cables to exhibit limited flame propagation and reduced emission of smoke and toxic gases is particularly pertinent in the railway industry, where the safety of passengers and crew is paramount. This focus ensures that the cables not only function reliably under normal operating conditions, with a continuous conductor temperature not exceeding 90 °C, but also perform adequately in emergency situations. Additionally, the standard specifies tinned copper conductors classified under EN 60228, which enhances conductivity and resistance to corrosion. The halogen-free insulation and sheath materials are another significant strength, aligning with modern environmental standards by minimizing the release of harmful substances in the event of a fire. The standard's comprehensive coverage of cable types (including unscreened and sheathed options) and cross-sectional areas ranging from 1 mm² to 400 mm² also makes it highly relevant for a variety of railway applications. This ensures versatility while maintaining strict compliance with safety and performance specifications. Moreover, EN 50264-2-1 is crucially articulated as a supplementary document to Part 1 “General requirements,” ensuring that users have access to a cohesive framework that encompasses both general and specific requirements for railway rolling stock cables. This holistic approach not only simplifies the implementation of the standard but also enhances its usability and applicability in real-world scenarios. Overall, EN 50264-2-1:2008 stands out as an essential reference document for manufacturers, engineers, and safety regulators involved in the production and application of railway rolling stock cables, effectively balancing performance, safety, and environmental considerations within the industry.

SIST EN 50264-2-1:2008は、特に鉄道用アプリケーションにおける重要な標準であり、特別な火性能を持った鉄道車両の電力および制御ケーブルに関する要件を定めています。この標準は、様々な電圧等級の単心ケーブルに対する構造や寸法を明確に示しており、0,6/1 kV、1,8/3 kV、3,6/6 kVの範囲で、無遮蔽・未被覆および被覆されたケーブルが含まれています。 強みとして、この標準はハロゲンフリーの絶縁体とハロゲンフリーの被覆を使用したクラス5の錫メッキ銅導体を特徴とし、鉄道車両内での固定配線や、運用中に限られた可動が発生する配線において使用するために設計されています。これにより、環境に配慮した安全性の高い配線が提供されます。 また、EN 50264-2-1は、ケーブルが90 °Cの連続導体温度を超えないことや、短絡条件下での最大温度が200 °C(5秒間の持続時間基準)であることを求めており、これにより高温環境での安定性が保障されます。さらに、火災条件における特別性能として、最大許容炎拡散速度や煙および有毒ガスの最大許容放出量についても基準が設けられており、鉄道車両の安全性を向上させることに寄与しています。 この標準は、一般的な要件を規定したパート1と併せて読むことが推奨されており、全体的な理解を深めるのに役立ちます。鉄道産業における適用範囲が広く、特に安全性と環境への配慮が求められる今日の状況において、その関連性はますます重要性を増しています。

Die Norm EN 50264-2-1:2008 ist von entscheidender Bedeutung für die Eisenbahnanwendungen, da sie spezifische Anforderungen an Kabel für den Schienenverkehr definiert, die besondere Brandschutzeigenschaften aufweisen. Besonders hervorzuheben ist der Geltungsbereich dieser Norm, die sich mit einadrigen Kabeln mit vernetztem elastomerischem Isoliermaterial befasst, die in verschiedenen Nennspannungen erhältlich sind, darunter 0,6/1 kV und 1,8/3 kV, sowohl ungeschirmt als auch ungeschützt. Ein wesentlicher Vorteil der EN 50264-2-1 liegt in den konstruktiven Anforderungen und Abmessungen, die für Kabel von 1 mm² bis 400 mm² festgelegt sind. Die Norm legt fest, dass alle Kabel mit klassen 5 zinnüberzogenen Kupferleitern gemäß EN 60228 ausgestattet sind und über halogenfreie Isolierungen sowie halogenfreie Ummantelungen verfügen. Diese Merkmale sind besonders Relevant in dem Kontext, in dem sie in Schienenfahrzeugen als feste Verkabelung oder bei begrenztem Flexiblen Einsatz zum Einsatz kommen. Die Norm definiert auch kritische Temperatureigenschaften, die eine kontinuierliche Temperatur des Leiters von maximal 90 °C und eine Höchsttemperatur bei Kurzschlussbedingungen von 200 °C (für maximal 5 Sekunden) vorsehen. Diese Anforderungen gewährleisten die Sicherheit und Zuverlässigkeit der Kabel unter verschiedenen Betriebsbedingungen. Ein herausragendes Merkmal der EN 50264-2-1 ist die Sicherstellung, dass die Kabel unter Brandbedingungen spezielle Leistungseigenschaften aufweisen. Die Norm gibt klare Richtlinien zur maximal zulässigen Flammbereitung und zur maximalen Emission von Rauch und giftigen Gasen vor, was zu einer signifikanten Erhöhung der Sicherheit in den Bahnanwendungen beiträgt. Insgesamt stellt die EN 50264-2-1:2008 eine essenzielle Richtlinie für die Herstellung und Verwendung von Leistungskabeln in Schienenfahrzeugen dar, deren Standards nicht nur die Funktionalität, sondern auch die Sicherheit der Einsätze im Eisenbahnsektor garantieren.

La norme EN 50264-2-1:2008 établit des exigences précises concernant les câbles d'alimentation et de contrôle utilisés dans le matériel roulant ferroviaire, et se concentre spécifiquement sur les câbles à isolation élastomère réticulée à cœur unique. Son champ d'application est crucial pour garantir la sécurité et l'efficacité des systèmes électriques dans les applications ferroviaires. L'un des principaux points forts de cette norme est son attention méticuleuse à la performance de feu. Les câbles spécifiés montrent des caractéristiques exceptionnelles en matière de propagation des flammes et d'émission de fumées toxiques, répondant ainsi aux exigences strictes de sécurité dans les environnements ferroviaires. Cela est particulièrement pertinent compte tenu des conditions d'exploitation souvent difficiles rencontrées par le matériel roulant. De plus, la norme couvre une gamme de types de câbles avec des tensions différentes, allant de 0,6/1 kV à 3,6/6 kV, ainsi que des dimensions de conducteurs variées de 1 mm² à 400 mm². Cela permet une grande flexibilité d'application tout en maintenant une uniformité dans la construction, ce qui est un atout pour les fabricants et les exploitants de matériel roulant. La spécification de conducteurs en cuivre étamé selon la norme EN 60228 assure également une bonne conductivité électrique, ainsi qu'une protection contre la corrosion, renforçant ainsi la durabilité des câbles dans des conditions variables. En intégrant des isolants et des gaines sans halogène, la norme EN 50264-2-1:2008 contribue à minimiser les risques environnementaux et de santé en cas d'incendie. Enfin, pour une utilisation adéquate et conforme, il est essentiel de lire EN 50264-2-1 en conjonction avec la Partie 1 « Exigences générales », ce qui non seulement renforce la compréhension des exigences, mais garantit également l'application correcte dans la conception et l'installation des câbles. En somme, la EN 50264-2-1:2008 représente une norme fondamentale dans le domaine des applications ferroviaires, combinant rigueur technique et sécurité incendie, et s'avère être un guide indispensable pour l'industrie.

SIST EN 50264-2-1:2008 표준은 철도 응용 분야에서 사용되는 전력 및 제어 케이블에 대한 중요하고 구체적인 요구 사항을 제공합니다. 본 표준은 단일 코어 케이블의 다양한 유형과 전압 등급에 대한 구체적인 기준을 정의하고 있으며, 0,6/1 kV 및 1,8/3 kV, 3,6/6 kV 등 다양한 전압 등급의 케이블을 포함합니다. 이 케이블들은 비차폐형 및 비피복형, 피복형 케이블로 구분되어 있으며, 기계적 특성과 전기적 성능을 충분히 확보하고 있습니다. EN 50264-2-1의 강점 중 하나는 모든 케이블이 EN 60228에 따라 제조된 클래스 5 주석 도금 구리를 도체로 사용하고 halogen-free 절연체와 sheath를 적용하여 안전성을 높인 점입니다. 이는 철도 차량의 고정 배선 또는 제한된 비틀림이 발생하는 배선에 적합하도록 설계되었습니다. 이러한 특성은 철도 운영 환경에서의 안정성과 내구성을 고려한 결과로, 신뢰성 있는 전류 전송과 안전한 작동을 보장합니다. 또한, 본 표준은 케이블의 지속적인 도체 온도가 90 °C 이하로 유지되어야 하며, 단시간의 단락 상태에서는 최대 200 °C까지 견딜 수 있는 조건을 제공하여, 안전한 전기 설비 운영을 지원합니다. 특히 화재 상황에서는 최대 허용 화염 전파 속도와 최대 허용 연기 및 독성 가스 배출량에 대한 특수 성능 특성을 갖추고 있어, 철도차량의 화재 안전성 향상에 기여합니다. EN 50264-2-1은 '일반 요구 사항'을 다루는 파트 1과 함께 읽혀야 하며, 이는 표준을 완전하게 이해하고 적용하는 데 중요한 역할을 합니다. 철도 분야에서의 전력 및 제어 케이블의 특수한 요구 사항을 충족시키기 위해 이 표준은 매우 높은 관련성을 갖추고 있으며, 최신 기술의 발전과 함께 발전하는 철도 안전 기준에 발맞추어 나가고 있습니다.