Information technology - Generic cabling systems - Part 2: Office premises

2013: Originator of XML version: first setup pilot of CCMC in 2012

Informationstechnik - Anwendungsneutrale Kommunikationskabelanlagen - Teil 2: Bürogebäude

Technologies de l'information - Systèmes de câblage générique - Partie 2: Locaux du secteur tertiaire

Informacijska tehnologija - Univerzalni sistemi polaganja kablov - 2. del: Pisarne - Dodatek A1

Ta evropski standard določa univerzalno polaganje kablov, ki podpira širok razpon komunikacijskih storitev za uporabo v pisarnah ali pisarniških prostorih v drugih vrstah prostorov, ki so sestavljeni iz ene ali več stavb na kampusu. Zahteve tega standarda lahko veljajo za druge prostore, ki niso izrecno določeni v drugih delih serije standardov EN 50173. Zajema uravnoteženo polaganje kablov in polaganje optičnih kablov. Ta evropski standard temelji na sklicih in zahtevah EN 50173-1. Ta evropski standard vsebuje dodatne zahteve, ki so primerne za pisarne, v katerih je največja razdalja, na kateri je treba distribuirati komunikacijske storitve, 2000 m. Načela tega mednarodnega standarda prav tako lahko veljajo za postavitve, ki niso v tem razponu.

General Information

Status
Withdrawn
Publication Date
09-Dec-2010
Withdrawal Date
30-Nov-2013
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
19-Mar-2021
Completion Date
19-Mar-2021

Relations

Buy Standard

Amendment
EN 50173-2:2008/A1:2011
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50173-2:2008/A1:2011
01-marec-2011
Informacijska tehnologija - Univerzalni sistemi polaganja kablov - 2. del: Pisarne -
Dodatek A1
Information technology - Generic cabling systems -- Part 2: Office premises
Informationstechnik - Anwendungsneutrale Kommunikationskabelanlagen -- Teil 2:
Bürogebäude
Technologies de l'information - Systèmes de câblage générique -- Partie 2: Locaux du
secteur tertiaire
Ta slovenski standard je istoveten z: EN 50173-2:2007/A1:2010
ICS:
33.040.50 Vodi, zveze in tokokrogi Lines, connections and
circuits
35.110 Omreževanje Networking
SIST EN 50173-2:2008/A1:2011 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50173-2:2008/A1:2011

---------------------- Page: 2 ----------------------

SIST EN 50173-2:2008/A1:2011

EUROPEAN STANDARD
EN 50173-2/A1

NORME EUROPÉENNE
December 2010
EUROPÄISCHE NORM

ICS 33.040.50


English version


Information technology -
Generic cabling systems -
Part 2: Office premises



Technologies de l'information -  Informationstechnik -
Systèmes de câblage générique - Anwendungsneutrale
Partie 2: Locaux du secteur tertiaire Kommunikationskabelanlagen -
Teil 2: Bürogebäude





This amendment A1 modifies the European Standard EN 50173-2:2007; it was approved by CENELEC on
2010-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia,
Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50173-2:2007/A1:2010 E

---------------------- Page: 3 ----------------------

SIST EN 50173-2:2008/A1:2011
EN 50173-2:2007/A1:2010 – 2 –
Foreword
This amendment was prepared by the Technical Committee CENELEC TC 215, Electrotechnical aspects of
telecommunication equipment.
The text of the draft was submitted to the formal vote and was approved by CENELEC as amendment A1 to
EN 50173-2:2007 on 2010-12-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.
The following dates were fixed:
– latest date by which the amendment has to be implemented

at national level by publication of an identical

national standard or by endorsement
(dop) 2011-12-01

– latest date by which the national standards conflicting

with the amendment have to be withdrawn
(dow) 2013-12-01
This standard introduces several changes in order to align the standard with the changes resulting mainly
from the introduction of new Channel classes and component Categories in EN 50173-1:201X.
For the convenience of the reader of this standard, the pertinent tables are reproduced in total, with grey
shading of new table cells. Where modifications to text apply to single expressions or a few words only, this
is indicated by underlining.

---------------------- Page: 4 ----------------------

SIST EN 50173-2:2008/A1:2011
– 3 – EN 50173-2:2007/A1:2010
Text of A1 to EN 50173-2:2007
General change
Replace all occurrences of “EN 50173-1:2007” with “EN 50173-1:201X” (in addition to the changes
indicated below).
Introduction
Replace Figure 1 with:
In addition, a number of Technical Reports have been developed to support or extend the application of
these standards, including:
- CLC/TR 50173-99-1, Cabling guidelines in support of 10 GBASE-T;
- CLC/TR 50173-99-2, Information technology – Implementation of BCT applications using cabling in
accordance with EN 50173-4.