HD 624.3 S1:1994/A2:1994
(Amendment)Materials used in communication cables - Part 3: PE insulation
- BACK
- 24-Nov-1994
- 29.060.20
- CLC/TC 46X
Materials used in communication cables - Part 3: PE insulation
Superseded by EN 50290-2-23:2001
Werkstoffe für Kommunikationskabel - Teil 3: PE-Isoliermischungen
Matériaux utilisés dans les câbles de communication - Partie 3: Polyéthylène pour enveloppes isolantes
Materials used in communication cables - Part 3: PE solid insulation
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST HD 624.3 S1:1996/A2:1996
01-maj-1996
Materials used in communication cables - Part 3: PE solid insulation
Materials used in communication cables -- Part 3: PE insulation
Werkstoffe für Kommunikationskabel -- Teil 3: PE-Isoliermischungen
Matériaux utilisés dans les câbles de communication -- Partie 3: Polyéthylène pour
enveloppes isolantes
Ta slovenski standard je istoveten z: HD 624.3 S1:1994/A2:1994
ICS:
29.035.20 3ODVWLþQLLQJXPHQLL]RODFLMVNL Plastics and rubber insulating
PDWHULDOL materials
SIST HD 624.3 S1:1996/A2:1996 en
2003-01.Slovenski inštitut
...
This May Also Interest You
IEC Corrigendum
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for×1 day
- 18-Aug-2016
- 29.060.20
- CLC/TC 46X
Is intended to define polyolefin insulated cables for insertion into local outdoor networks.is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors,includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand)
- Standard30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Nov-2005
- 30-Sep-2008
- 29.060.20
- CLC/TC 46X
- Amendment5 pagesEnglish languagesale 10% offe-Library read for×1 day
HD 620 applies to cables with extruded insulation and for rated voltages Uo/U(Um) from 3,6/6 (7,2) kV up to 20,8/36(42) kV used in power distribution systems of voltages not exceeding the maximum r.m.s. value of the system voltage Um. This Part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD. Test methods specified are given EN 60228, EN 60229, EN 60332-1-2, EN 60811, EN 60885-3, HD 605 and HD 632. Attention should be drawn to the fact that a significant number of sections include references to long term tests which are collected in HD 605. These long-term tests are considered as necessary and reflect the best available knowledge for the existing cable design. They are related to specific designs and different philosophies concerning adequate measures against the influence of water. However, it is the firm intention to reduce this large number of different tests, but more experience should be gained before starting to rationalise this important matter. The particular types of cables are specified in Parts 9 to 12. NOTE Parts 3, 4, 5, 6, 7 and 8 were withdrawn in HD 620 S2.
- Standardization document854 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft872 pagesEnglish languagesale 10% offe-Library read for×1 day
This document describes the procedure and rules for extended application of results of tests carried out according to the test methods described in EN 50399, EN 60332 1 2 and EN 61034 2. The EXAP rules described apply to EN 50399 test results used for classification according to EN 13501 6 in classes B2ca, Cca and Dca, additional smoke production classes s1, s2 and s3 and flaming droplets/particles, to EN 60332 1 2 test results used for classification in classes B2ca, Cca, Dca and Eca and to EN 61034 2 test results used for classification in classes s1a and s1b. No EXAP procedure and rules have been developed in respect to the results of tests carried out according to the test method described in EN 60754 2. As the parameters (pH and conductivity) for each cable in a family are determined based upon calculation using material test results, this is considered as a matter of direct application. Material test results taken from any one sample of finished cable from a family are sufficient to calculate the parameters for each cable in the family. Cables with a diameter of 5,0 mm or less are expected to be tested as bundles according to EN 50399. Cables with a diameter of less than or equal to 5,0 mm are included in the specific and general EXAP rules for single core unsheathed power cables only. The rules apply to circular and non-circular cables provided that they fall within the scope of the relevant test method. A specific EXAP rule has been developed for any of the types of electric cable families as defined in this document. A general EXAP rule has been developed for all electric cable families unless otherwise stated elsewhere in this document. NOTE 1 Multicore power cables are sometimes referred to as control cables with a rated voltage but for the purposes of this document are considered as power cables. For multipair, multitriple and multiquad control cables, either the general EXAP rule or the specific EXAP rule for power cables or the specific EXAP rule for communication cables can be applied. The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range of cable constructions (product family). An EXAP is only possible when cables belong to a family as defined in this document. NOTE 2 For the purposes of this document, the term "electric cables" also covers optical fibre cables.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft27 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard gives the general requirements for rigid and flexible energy cables of rated voltages U0/U up to and including 450/750 V AC, used in power installations and with domestic and industrial appliances and equipment. NOTE 1 For some types of flexible cables, the term "cord" is used. NOTE 2 Rated voltages are given by reference to alternating current systems. Use of the cables in direct current systems is permitted. NOTE 3 National regulations may prescribe additional performance requirements for cables that are not given in the particular requirements. For example for buildings with high levels of public access, additional fire performance requirements may be applicable, The test methods for checking conformity with the requirements are given in other standards (see Introduction). The particular types of cables are specified in EN 50525-2 (series) and EN 50525-3 (series). The individual parts within those two series are collectively referred to hereafter as "the particular specifications". Only the sizes (conductor class, cross-sectional area), number of cores, other constructional features and rated voltages given in the particular specification apply to the individual cable type. The code designations of these types of cables are in accordance with HD 361.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft7 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the apparatus and methods of test for the assessment of vertical flame spread, heat release, smoke production and occurrence of flaming droplets/particles of vertically mounted electric cables under defined conditions. NOTE For the purpose of this document, the term “electric cable” covers all power, control and communication cables, including optical fibre cables and hybrid cables used for the conveyance of energy and/or signals. This document details the apparatus for the fire propagation testing and the arrangement and calibration of the instrumentation to be installed to measure the heat release and the smoke production during the test. The combustion gases are collected in a hood above the test chamber and conveyed through an exhaust system, which allows the measurement of heat release rate and smoke production. Test procedures to be used for type approval testing for classification of cables in classes [2, 7] B1ca, B2ca, Cca and Dca are given. Cable installation on the test ladder and the volume of air passing through the chamber are in accordance with the Commission Decision 2006/751/EC [6], which is reflected in the requirements of this document.
- Standard85 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft79 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies test methods for cable management systems intended (CMS) to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions. This document establishes a non-hierarchical classification for this ability. Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document. CMS intended to provide support and fire protection for cables are tested according to EN 1366 11. This document does not apply to powertrack systems. NOTE Rules for testing CMS-support for fibre optic cables and communication cables are under consideration.
- Technical report49 pagesEnglish languagesale 10% offe-Library read for×1 day
NEW!IEC 60799:2018 is available as IEC 60799:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60799:2018 specifies requirements for cord sets and interconnection cord sets for household and similar general purpose equipment. It does not apply to cord sets for industrial purposes (with plugs and connectors according to IEC 60309) nor to cord extension sets. This third edition cancels and replaces the second edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with IEC 60320-1:2015; - extension to include appliance couplers in accordance with IEC 60320-2-3:- (Under preparation. Stage at the time of publication: IEC/FDIS 60320-2-3:2018).
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
This standard specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.