EN 60335-1:2002/A2:2006
(Amendment)Household and similar electrical appliances - Safety - Part 1: General requirements
Household and similar electrical appliances - Safety - Part 1: General requirements
Gives safety of electrical appliances for hausehold and similar use such as appliances intended to be used by laymen in shops, in light industry and on farm, the rated voltage of the appliances being not more than 250 V for single-phase appliances, 480 V for other appliances. This standard does not deal appliances intended exclusively for industrial purposes, used in locations where special conditions prevail, appliances for medical purposes, electronic equipment, personal computers, blankets, pads and similar flexible heating appliances.
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 1: Allgemeine Anforderungen
Appareils électrodomestiques et analogues - Sécurité - Partie 1: Prescriptions générales
Gospodinjski in podobni električni aparati - Varnost - 1. del: Splošne zahteve (IEC 60335-1:2001/A2:2006 + popravek avg. 2006)
Obravnava varnost električnih aparatov, za gospodinjstva in podobne namene, katerih napetost je manjša od 250 V za enofazne aparate in od 480 V za ostale aparate.
General Information
Relations
Standards Content (Sample)
61/2869/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJET DE COMITÉ POUR VOTE (CDV)
Project number IEC 60335-1-A2 Ed 4.0
Numéro de projet
IEC/TC or SC: Date of circulation Closing date for voting (Voting
TC 61
Date de diffusion mandatory for P-members)
CEI/CE ou SC:
Date de clôture du vote (Vote
2005-04-22
obligatoire pour les membres (P))
2005-09-23
Titre du CE/SC: Sécurité des appareils Safety of household and similar
TC/SC Title:
électrodomestiques et analogues electrical appliances
Secretary: Mr A. P. Brazauski, U.S.A.
Secrétaire:
Also of interest to the following committees Supersedes document
Intéresse également les comités suivants Remplace le document
61B, 61C, 61D, 61E, 61F, 61H, 61J 61/2821/MCR
Functions concerned
Fonctions concernées
Safety EMC Environment Quality assurance
Sécurité
CEM Environnement Assurance qualité
CE DOCUMENT EST TOUJOURS À L'ÉTUDE ET SUSCEPTIBLE DE THIS DOCUMENT IS STILL UNDER STUDY AND SUBJECT TO CHANGE. IT
MODIFICATION. IL NE PEUT SERVIR DE RÉFÉRENCE. SHOULD NOT BE USED FOR REFERENCE PURPOSES.
LES RÉCIPIENDAIRES DU PRÉSENT DOCUMENT SONT INVITÉS À RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT, WITH THEIR
PRÉSENTER, AVEC LEURS OBSERVATIONS, LA NOTIFICATION DES COMMENTS, NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF
DROITS DE PROPRIÉTÉ DONT ILS AURAIENT ÉVENTUELLEMENT WHICH THEY ARE AWARE AND TO PROVIDE SUPPORTING
CONNAISSANCE ET À FOURNIR UNE DOCUMENTATION EXPLICATIVE. DOCUMENTATION.
Titre : CEI 60335-1-A2 Ed 4.0: Partie 1:
Title : IEC 60335-1-A2 Ed 4.0: Household and
Prescriptions générales
similar electrical appliances - Safety - Part 1:
General requirements
Introductory note
Note d'introduction
This document is circulated according to the decisions
Ce document est diffusé conformément à la décision prise
taken at the meetings of TC 61in:
à la réunion du TC 61 de
Durban – see 61/2454/RM
Durban – voir 61/2454/RM
Toulouse – see 61/2568/RM
Toulouse – voir 61/2568/RM
Kuala Lumpur – see 61/2712A/RM
Kuala Lumpur – voir 61/2712A/RM
Brisbane – see 61/2800A/RM
Brisbane – voir 61/2800A/RM
History:
Historique:
61/2236/DC 61/2350A/INF
61/2265/DC 61/2351A/INF
61/2313/DC 61/2356A/INF
61/2331/DC 61/2365A/INF
61/2321/DC 61/2363A/INF
61/2394/DC 61/2478A/INF
61/2395/DC 61/2479A/INF
61/2452/DC 61/2482A/INF
61/2461/DC 61/2650A/INF
61/2560/DC 61/2655A/INF
61/2561/DC 61/2651A/INF
61/2685/DC 61/2761A/INF
61/2703/DC 61/2756A/INF
61/2714/DC 61/2760A/INF
Plus MT 4, MT22, MT23 and Chairman reports from
Brisbane
ATTENTION ATTENTION
CDV soumis en parallèle au vote (CEI) Parallel IEC CDV/CENELEC Enquiry
et à l’enquête (CENELEC)
permitted to download this electronic file, to make a copy and to print out the content for the sole
purpose of preparing National Committee positions. You may not copy or "mirror" the file or
printed version of the document, or any part of it, for any other purpose without permission in
writing from IEC.
60335-1/Amend. 2/Ed 4.0/CDV © IEC 2
FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
61/XXXX/FDIS 61/XXXX/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
1)
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
___________
1 Scope
Replace the two dashed items in the third paragraph by the following:
– persons (including children) whose physical, sensory or mental capabilities or lack of
experience and knowledge prevents them from using the appliance safely without initial
supervision or instruction;
– children playing with the appliance.
2 Normative references
Delete from the existing list the following normative references:
IEC 60249-2-4
IEC 20249-2-5
Replace reference to IEC 60085 by the following new reference:
IEC 60085:2004, Electrical insulation – Thermal classification
Replace reference to IEC 60664-3 by the following new reference:
IEC 60664-3:2003, Insulation coordination for equipment within low-voltage systems - Part 3:
Use of coating, potting or moulding for protection against pollution
———————
1)
The National Committees are requested to note that for this publication the maintenance result date is 2006.
60335-1 Amend. 2/Ed 4.0/CDV © IEC 3
Replace reference to IEC 60695-2-2 by the following new reference:
IEC 60695-11-5:2004, Fire hazard testing – Part 11-5: Test flames – Needle-flame test method
– Apparatus, confirmatory test arrangement and guidance
Replace reference to IEC 61000-4-11 by the following new reference:
IEC 61000-4-11:2004, Electromagnetic compatibility (EMC) - Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity
tests
Replace reference to IEC 60384-14:1993 by the following reference:
IEC 60384-14 1993 Fixed capacitors for use in electronic equipment – Part 14:
Amendment 1 (1995) Sectional specification: Fixed capacitors for electromagnetic
interference suppression and connection to the supply mains
Replace reference to IEC 60730-1:1999 by the following reference:
IEC 60730-1 1999 Automatic electrical controls for household and similar use – Part
1)
Amendment 1 1: General requirements
(2003)
Replace reference to IEC 60730-2-8:2000 by the following reference:
IEC 60730-2-8 2000 Automatic electrical controls for household and similar use – Part
2)
Amendment 1 2-8: Particular requirements for electrically operated water valves,
(2002)
including mechanical requirements
Replace reference to IEC 61558-1:1997 by the following reference:
IEC 61558-1 1997 Safety of power transformers, power supply units and similar –
3)
Amendment 1 Part 1: General requirements and tests
(1998)
Replace reference to ISO 9772:2001 by the following reference:
ISO 9772 2001 Cellular plastics – Determination of horizontal burning
Amendment 1 (2003) characteristics of small specimens subjected to a small flame
Add the following new references:
IEC 60691:2002, Thermal-links - Requirements and application guide
IEC 61810-1:2003, Electromechanical elementary relays - Part 1: General and safety
requirements
IEC 62151, Safety of equipment electrically connected to a telecommunication network
———————
1)
There exists a consolidated edition 3.1 (2003) that includes edition 3 and its amendment 1.
2)
There exists a consolidated edition 2.1 (2003) that includes edition 2 and its amendment 1.
3)
There exists a consolidated edition 1.1 (1998) that includes edition 1 and its amendment 1.
60335-1 Amend. 2/Ed 4.0/CDV © IEC 4
3 Definitions
Add the following new definition:
3.1.12
remote operation
control of an appliance by a command that can be initiated out of sight of the appliance using
means such as telecommunications, sound controls or bus systems
7 Marking and instructions
7.5 In the first paragraph of the requirement, replace (in two places) “mean value” by
“arithmetic mean value”.
7.6 Replace the third and fourth symbols by the following:
3 [symbol 5032-1 of IEC 60417] three-phase alternating current
3N [symbol 5032-2 of IEC 60417] three-phase alternating current with neutral
Replace the symbol 1641 of ISO 7000 by the following:
[symbol 1641 of ISO 7000] Operator’s manual; operating instructions
Add the following symbol:
[symbol 0790 of ISO 7000] Read operator's manual
7.12 Add the following:
The instructions shall state the substance of the following:
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge unless they have been
given initial supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
8 Protection against access to live parts
8.1.1 Renumber the existing note as Note 1.
Add the following note after the third paragraph of the test specification.
NOTE 2 ”Without appreciable force” is considered to be a force not exceeding 1 N.
60335-1 Amend. 2/Ed 4.0/CDV © IEC 5
8.1.2 Renumber the existing note as Note 1.
Add the following note after the first paragraph of the test specification.
NOTE 2 ”Without appreciable force” is considered to be a force not exceeding 1 N.
8.1.3 Add the following note after the first paragraph of the test specification.
NOTE 1 ”Without appreciable force” is considered to be a force not exceeding 1 N.
Renumber the existing note as Note 2.
8.1.4 Add the following dashed item to the second paragraph of the requirement.
– for voltages having a peak value over 15 kV, the energy in the discharge shall not exceed
350 mJ.
Replace the third sentence of the second paragraph of the test specification by the following.
The quantity of electricity and energy in the discharge is measured using a resistor having a
nominal non-inductive resistance of 2 000 Ω.
10 Power input and current
10.1 Add the following to the requirement.
The permissible deviations apply for both limits of the range for appliances marked with a
rated voltage range having limits differing by more than 10 % of the arithmetic mean value of
the range.
In the second paragraph of the test specification, replace “mean value” by “arithmetic mean
value”.
Delete Notes 2 and 3.
Add the following to the test specification.
The test is carried out at both the upper and lower limits of the ranges for appliances marked
with one or more rated voltage ranges, unless the marking of the rated power input is
related to the arithmetic mean value of the relevant voltage range, in which case the test is
carried out at a voltage equal to the arithmetic mean value of that range.
10.2 Add the following to the requirement.
The permissible deviations apply for both limits of the range for appliances marked with a
rated voltage range having limits differing by more than 10 % of the arithmetic mean value of
the range.
In the second paragraph of the test specification, replace “mean value” by “arithmetic mean
value”.
Delete Notes 2 and 3.
60335-1 Amend. 2/Ed 4.0/CDV © IEC 6
Add the following to the test specification.
The test is carried out at both the upper and lower limits of the ranges for appliances marked
with one or more rated voltage ranges, unless the marking of the rated current is related to
the arithmetic mean value of the relevant voltage range, in which case the test is carried out
at a voltage equal to the arithmetic mean value of that range.
11 Heating
Table 3
In the first entry, replace the terms “class A, class E, class B, class F and class H” by the terms “class
105, class 120, class 130, class 155 and class 180” respectively.
Replace the fifth entry by the following:
Rubber, polychloroprene or polyvinyl chloride insulation of internal and external wiring,
including supply cords:
– without temperature rating 50
j T-25
– with temperature rating (T)
Add the following footnote:
j
IEC 60245 Types 53, 57 and 87 supply cords have a T rating of 60 °C;
IEC 60227 Types 52 and 53 supply cords have a T rating of 70 °C;
IEC 60227 Types 56 and 57 supply cords have a T rating of 90 °C.
14 Transient overvoltages
Replace the second paragraph of the test specification by the following:
The impulse test voltage has a no-load waveshape corresponding to the 1,2/50 µs standard
impulse specified in IEC 61180-1. It is supplied from a generator having a conventional
impedance not exceeding 42 Ω. The impulse test voltage is applied three times for each
polarity with intervals of at least 1 s.
Delete Note 3.
16 Leakage current and electric strength
16.3 Replace the first paragraph of the test specification by the following.
Immediately after the test of 16.2, the insulation is subjected to a voltage having a frequency
of 50 Hz or 60 Hz for 1 min, in accordance with IEC 61180-1. The values of the test voltage
for different types of insulation are given in Table 7.
Delete the penultimate paragraph of the test specification.
19 Abnormal operation
19.11.2 In the first paragraph of the test specification, add the following after Note 2:
60335-1 Amend. 2/Ed 4.0/CDV © IEC 7
g) failure of an electronic power switching device in a partial turn-on mode with loss of
gate control. During this test, winding temperatures shall not exceed the values given in
19.7.
NOTE 3 This mode may be simulated by disconnecting the electronic power switching device gate terminal and
connecting an external adjustable power supply between the gate and source terminal of the electronic power
switching device. The power supply is then varied so as to achieve a current that will not damage the electronic
power switching device but give the most onerous conditions of test.
NOTE 4 Examples of electronic power switching devices are IGBT’s and FET’s.
19.11.4 In the first paragraph, replace “switch” by “device” in three places.
Add the following paragraph before the last paragraph:
Appliances incorporating a protective electronic circuit that relies upon a programmable
component to function correctly are subjected to the test 19.11.4.8. The test is carried out
after removal of all batteries and other components intended to maintain the programmable
component supply voltage during mains supply voltage dips, interruptions and variations.
In the last paragraph, replace "arresters" by "protective devices“.
Add the following new subclause:
19.11.4.8 The appliance is supplied at rated voltage and operated under normal operation.
After approximately 60 s, the power supply voltage is reduced to a level such that the
appliance ceases to respond to user inputs or parts controlled by the programmable
component cease to operate, whichever occurs first. This value of supply voltage is recorded.
The appliance is supplied at rated voltage and operated under normal operation. The
voltage is then reduced to a value of approximately 10 % less than the recorded voltage. It is
held at this value for approxim
...
6/29(16., 6,67(1$
67$1'$5'
QRYHPEHU
*RVSRGLQMVNLLQSRGREQLHOHNWULþQLDSDUDWL±9DUQRVWGHO6SORãQH]DKWHYH
,(&$SRSUDYHNDYJ
+RXVHKROGDQGVLPLODUHOHFWULFDODSSOLDQFHV6DIHW\3DUW*HQHUDOUHTXLUHPHQWV
,(&$FRUULJHQGXP
,&6 5HIHUHQþQDãWHYLOND
6,67(1$HQ
!"#$%&’( )&!*+,%- .
EUROPEAN STANDARD
EN 60335-1/A2
NORME EUROPÉENNE
August 2006
EUROPÄISCHE NORM
ICS 13.120; 97.030
English version
Household and similar electrical appliances -
Safety
Part 1: General requirements
(IEC 60335-1:2001/A2:2006 + corrigendum 2006)
Appareils électrodomestiques Sicherheit elektrischer Geräte
et analogues - für den Hausgebrauch
Sécurité und ähnliche Zwecke
Partie 1: Prescriptions générales Teil 1: Allgemeine Anforderungen
(CEI 60335-1:2001/A2:2006 + (IEC 60335-1:2001/A2:2006 +
corrigendum 2006) corrigendum 2006)
This amendment A2 modifies the European Standard EN 60335-1:2002; it was approved by CENELEC on
2006-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60335-1:2002/A2:2006 E
Foreword
The text of document 61/2996/FDIS, future amendment 2 to IEC 60335-1:2001, prepared by the IEC
Technical Committee 61, Safety of household and similar electrical appliances, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 60335-1:2002
on 2006-07-01.
The following dates are applicable:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2007-04-01
– date on which national standards conflicting
with the amendment have to be withdrawn (dow) 2009-07-01
This amendment supplements or modifies the corresponding clauses of EN 60335-1:2002.
There are no special national conditions causing a deviation from this amendment.
There are no national deviations from this amendment.
p NOTE In this document, p is used in the margin to indicate instructions for preparing the printed version.
____________
Endorsement notice
The text of amendment 2:2006 to the International Standard IEC 60335-1:2001 and its corrigendum
August 2006 was approved by CENELEC as an amendment to the European Standard without any
modification.
p Replace Annex ZC (of EN 60335-1:2002/A1:2004) by the new Annex ZC.
p In Annex ZD (of EN 60335-1:2002), correct the IEC reference for Ordinary polyvinyl chloride sheathed
flexible cord to read "60227 IEC 53".
____________
- 3 - EN 60335-1:2002/A2:2006
Annex ZC
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
1) 2)
IEC 60061-1 - Lamp caps and holders together with EN 60061-1 1993
(mod) gauges for the control of interchangeability
and safety
Part 1: Lamp caps
1) 2)
IEC 60068-2-2 - Environmental testing EN 60068-2-2 1993
Part 2: Tests - Tests B: Dry heat
1) 2)
IEC 60068-2-32 - Basic environmental testing procedures EN 60068-2-32 1993
Part 2: Tests - Test Ed: Free fall
1) 2)
IEC 60068-2-75 - Environmental testing EN 60068-2-75 1997
Part 2-75: Tests - Test Eh: Hammer tests
1)
IEC 60083 - Plugs and socket-outlets for domestic and - -
similar general use standardized in member
countries of IEC
IEC 60085 2004 Electrical insulation - Thermal classification EN 60085 2004
IEC 60112 2003 Method for the determination of the proof EN 60112 2003
and the comparative tracking indices of solid
insulating materials
IEC 60127 Series Miniature fuses EN 60127 Series
3)
IEC 60227 Series Polyvinyl chloride insulated cables of rated
voltages up to and including 450/750 V
1) 2)
IEC 60238 - Edison screw lampholders EN 60238 2004
+ corr. January 2005
4)
IEC 60245 Series Rubber insulated cables - Rated voltages up
to and including 450/750 V
1) 2)
IEC 60252-1 - AC motor capacitors EN 60252-1 2001
Part 1: General - Performance, testing and
rating - Safety requirements - Guide for
installation and operation
1)
Undated reference.
2)
Valid edition at date of issue.
3)
The HD 21 series, which is related to, but not directly equivalent with the IEC 60227 series, applies instead.
4)
The HD 22 series, which is related to, but not directly equivalent with the IEC 60245 series, applies instead.
Publication Year Title EN/HD Year
1) 2)
IEC 60320-1 - Appliance couplers for household and EN 60320-1 2001
similar general purposes
Part 1: General requirements
1) 2)
IEC 60320-2-2 - Appliance couplers for household and EN 60320-2-2 1998
similar general purposes
Part 2-2: Interconnection couplers for
household and similar equipment
1) 2)
IEC 60320-2-3 - Appliance couplers for household and EN 60320-2-3 1998
similar general purposes
Part 2-3: Appliance coupler with a degree of
protection higher than IPX0
IEC 60384-14 2005 Fixed capacitors for use in electronic EN 60384-14 2005
equipment
Part 14: Sectional specification - Fixed
capacitors for electromagnetic interference
suppression and connection to the supply
mains
IEC 60417 Data- Graphical symbols for use on equipment - -
base
1) 2)
IEC 60529 - Degrees of protection provided by EN 60529 1991
enclosures (IP Code) + corr. May 1993
IEC 60598-1 (mod) 2003 Luminaires EN 60598-1 2004
Part 1: General requirements and tests
IEC 60664-1 (mod) 1992 Insulation coordination for equipment within
+ A1 2000 low-voltage systems
+ A2 2002 Part 1: Principles, requirements and tests EN 60664-1 2003
IEC 60664-3 2003 Insulation coordination for equipment within EN 60664-3 2003
low-voltage systems
Part 3: Use of coating, potting or moulding
for protection against pollution
IEC 60691 2002 Thermal-links - Requirements and EN 60691 2003
application guide
1) 2)
IEC 60695-2-11 - Fire hazard testing EN 60695-2-11 2001
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test
method for end-products
1) 2)
IEC 60695-2-12 - Fire hazard testing EN 60695-2-12 2001
Part 2-12: Glowing/hot-wire based test
methods - Glow-wire flammability test
method for materials
1) 2)
IEC 60695-2-13 - Fire hazard testing EN 60695-2-13 2001
Part 2-13: Glowing/hot-wire based test
methods - Glow-wire ignitability test method
for materials
1) 2)
IEC 60695-10-2 - Fire hazard testing EN 60695-10-2 2003
Part 10-2: Abnormal heat - Ball pressure
test
- 5 - EN 60335-1:2002/A2:2006
Publication Year Title EN/HD Year
IEC 60695-11-5 2004 Fire hazard testing EN 60695-11-5 2005
Part 11-5: Test flames - Needle-flame test
method - Apparatus, confirmatory test
arrangement and guidance
1) 2)
IEC 60695-11-10 - Fire hazard testing EN 60695-11-10 1999
Part 11-10: Test flames - 50 W horizontal
and vertical flame test methods
IEC 60730-1 (mod) 1999 Automatic electrical controls for household EN 60730-1 2000
A1 (mod) 2003 and similar use A1 2004
Part 1: General requirements A11 2002
A12 2003
A13 2004
A14 2005
5)
A15 200X
IEC 60730-2-8 2000 Automatic electrical controls for household EN 60730-2-8 2002
(mod) and similar use
A1 (mod) 2002 Part 2-8: Particular requirements for A1 2003
electrically operated water valves, including
mechanical requirements
1) 2)
IEC 60738-1 - Directly heated positive temperature EN 60738-1 2006
coefficient thermistors
Part 1: Generic specification
1)
IEC 60906-1 - IEC system of plugs and socket-outlets for - -
household and similar purposes
Part 1: Plugs and socket-outlets 16 A 250 V
a.c.
IEC 60990 1999 Methods of measurement of touch current EN 60990 1999
and protective conductor current
IEC 60999-1 1999 Connecting devices - Electrical copper EN 60999-1 2000
conductors - Safety requirements for screw-
type and screwless-type clamping units
Part 1: General requirements and particular
requirements for clamping units for
conductors from 0,2 mm² up to 35 mm²
(included)
1) 2)
IEC 61000-4-2 - Electromagnetic compatibility (EMC) EN 61000-4-2 1995
Part 4-2: Testing and measurement
techniques - Electrostatic discharge
immunity test
1) 2)
IEC 61000-4-3 - Electromagnetic compatibility (EMC) EN 61000-4-3 2006
Part 4-3 : Testing and measurement
techniques - Radiated, radio-frequency,
electromagnetic field immunity test
1) 2)
IEC 61000-4-4 - Electromagnetic compatibility (EMC) EN 61000-4-4 2004
Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst
immunity test
5)
To be published
Publication Year Title EN/HD Year
1) 6)
IEC 61000-4-5 - Electromagnetic compatibility (EMC) EN 61000-4-5 200X
Part 4-5: Testing and measurement
techniques - Surge immunity test
1) 2)
IEC 61000-4-6 - Electromagnetic compatibility (EMC) EN 61000-4-6 1996
Part 4-6: Testing and measurement
techniques - Immunity to conducted
disturbances, induced by radio-frequency
fields
IEC 61000-4-11 2004 Electromagnetic compatibility (EMC) EN 61000-4-11 2004
Part 4-11: Testing and measurement
techniques - Voltage dips, short
interruptions and voltage variations
immunity tests
1) 2)
IEC 61000-4-13 - Electromagnetic compatibility (EMC) EN 61000-4-13 2002
Part 4-13: Testing and measurement
techniques - Harmonics and interharmonics
including mains signalling at a.c. power port,
low frequency immunity tests
IEC 61032 1997 Protection of persons and equipment by EN 61032 1998
enclosures - Probes for verification
IEC 61058-1 (mod) 2000 Switches for appliances
+ A1 2001 Part 1: General requirements EN 61058-1 2002
1) 2)
IEC 61180-1 - High-voltage test techniques for low-voltage EN 61180-1 1994
equipment
Part 1: Definitions, test and procedure
requirements
1) 2)
IEC 61180-2 - High-voltage test techniques for low-voltage EN 61180-2 1994
equipment
Part 2: Test equipment
7)
EN 61558-1
IEC 61558-1 (mod) 1997 Safety of power transformers, power supply 1997
units and similar + corr. April 2003
A1 1998 Part 1: General requirements and tests A1 1998
A11 2003
IEC 61558-2-6 1997 Safety of power transformers, power supply EN 61558-2-6 1997
units and similar
Part 2-6: Particular requirements for safety
isolating transformers for general use
1) 2)
IEC 61770 - Electric appliances connected to the water EN 61770 1999
mains - Avoidance of backsiphonage and
failure of hose-sets
IEC 62151 2000 Safety of equipment electrically connected - -
to a telecommunication network
6)
To be ratified.
7)
EN 61558-1 is superseded by EN 61558-1:2005, which is based on IEC 61558-1:2005.
- 7 - EN 60335-1:2002/A2:2006
Publication Year Title EN/HD Year
1) 2)
ISO 2768-1 - General tolerances EN 22768-1 1993
Part 1: Tolerances for linear and angular
dimensions without individual tolerance
indications
ISO 7000 Data- Graphical symbols for use on equipment - - -
base Index and synopsis
ISO 9772 2001 Cellular plastics - Determination of - -
A1 2003 horizontal burning characteristics of small
specimens subjected to a small flame
- -
INTERNATIONAL IEC
STANDARD 60335-1
AMENDMENT 2
2006-05
Amendment 2
Household and similar electrical appliances –
Safety –
Part 1:
General requirements
This English-language version is derived from the original
bilingual publication by leaving out all French-language
pages. Missing page numbers correspond to the French-
language pages.
IEC 2006 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,
including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
S
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
60335-1 Amend. 2 IEC:2006 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances.
The text of this amendment is based on the following docume
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.