Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 5: Measurement of conducted emissions - Workbench Faraday Cage method

Describes a method to measure the conducted electromagnetic emission of integrated circuits either applied on a standardised test-board or on a final printed circuit board (PCB). Has a high repeatability and a good relationship to the measured RF emission of final applications with the integrated circuits used.

Integrierte Schaltungen - Messung von elektromagnetischen Aussendungen im Frequenzbereich von 150 kHz bis 1 GHz - Teil 5: Messung der leitungsgeführten Aussendungen - Verfahren mit Faradayschem Käfig für Messtische

Circuits intégrés - Mesure des émissions électromagnétiques, 150 kHz à 1 GHz - Partie 5: Mesure des émissions conduites - Méthode de la cage de Faraday sur banc de travail

Décrit une méthode de mesure de l'émission électro-magnétique conduite des circuits intégrés, qu'ils soient utilisés avec une carte électronique de test normalisée ou avec une carte à circuit imprimé finale. Présente une répétabilité élevée et convient à l'émission mesurée RF des applications finales avec ces circuits intégrés.

Integrirana vezja – Meritve elektromagnetnega sevanja, od 150 kHz do 1 GHz – 5. del: Meritve prevajanega sevanja – Metoda z namizno Faradayevo kletko (IEC 61967-5:2003)

General Information

Status
Published
Publication Date
22-Apr-2003
Withdrawal Date
31-Mar-2006
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
23-Apr-2003
Completion Date
23-Apr-2003

Buy Standard

Standard
EN 61967-5:2005
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 61967-5:2005

STANDARD
december 2005
Integrirana vezja – Meritve elektromagnetnega sevanja, od 150 kHz do 1 GHz –
5. del: Meritve prevajanega sevanja – Metoda z namizno Faradayevo kletko
(IEC 61967-5:2003)
Integrated circuits – Measurement of electromagnetic emissions, 150 kHz to 1 GHz
– Part 5: Measurement of conducted emissions – Workbench Faraday Cage
method (IEC 61967-5:2003)
ICS 31.200 Referenčna številka
SIST EN 61967-5:2005(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 61967-5
NORME EUROPÉENNE
EUROPÄISCHE NORM April 2003

ICS 31.200


English version


Integrated circuits –
Measurement of electromagnetic emissions, 150 kHz to 1 GHz
Part 5: Measurement of conducted emissions –
Workbench Faraday Cage method
(IEC 61967-5:2003)


Circuits intégrés -  Integrierte Schaltungen –
Mesure des émissions électromagnétiques, Messung von elektromagnetischen
150 kHz à 1 GHz Aussendungen im Frequenzbereich
Partie 5: Mesure des émissions conduites - von 150 kHz bis 1 GHz
Méthode de la cage de Faraday Teil 5: Messung der leitungsgeführten
sur banc de travail Aussendungen –
(CEI 61967-5:2003) Verfahren mit Faradayschem Käfig
für Messtische
(IEC 61967-5:2003)


This European Standard was approved by CENELEC on 2003-04-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 61967-5:2003 E

---------------------- Page: 2 ----------------------

EN 61967-5:2003 - 2 -
Foreword
The text of document 47A/661/FDIS, future edition 1 of IEC 61967-5, prepared by SC 47A, Integrated
circuits, of IEC TC 47, Semiconductor devices, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61967-5 on 2003-04-01.
This part of EN 61967 is to be read in conjunction with EN 61967-1:2002.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2004-01-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2006-04-01

Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annexes A and ZA are normative and annexes B, C and D are informative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61967-5:2003 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 61967-4 NOTE Harmonized as EN 61967-4:2002 (not modified).
IEC 61967-6 NOTE Harmonized as EN 61967-6:2002 (not modified).
__________

---------------------- Page: 3 ----------------------

- 3 - EN 61967-5:2003
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international publication has been modified by co
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.