Amendment 1 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 15: Flickermeter - Functional and design specifications

Amendement 1 - Compatibilité électromagnétique (CEM) - Partie 4: Techniques d'essai et de mesure - Section 15: Flickermètre - Spécifications fonctionnelles et de conception

General Information

Status
Published
Publication Date
12-Jan-2003
Current Stage
DELPUB - Deleted Publication
Completion Date
24-Aug-2010
Ref Project

Relations

Buy Standard

Standard
IEC 61000-4-15:1997/AMD1:2003 - Amendment 1 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 15: Flickermeter - Functional and design specifications Released:1/13/2003 Isbn:2831867754
English and French language
21 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
61000-4-15
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
2003-01
PUBLICATION FONDAMENTALE EN CEM
BASIC EMC PUBLICATION
Amendement 1
Compatibilité électromagnétique (CEM) –
Partie 4-15:
Techniques d'essai et de mesure –
Flickermètre – Spécifications fonctionnelles
et de conception
Amendment 1
Electromagnetic compatibility (EMC) –
Part 4-15:
Testing and measurement techniques –
Flickermeter – Functional and design
specifications
 IEC 2003 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch  Web: www.iec.ch
CODE PRIX
L
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61000-4-15 Amend.1 © CEI:2003

AVANT-PROPOS
Cet amendement a été préparé par le sous-comité 77A: Phénomènes basse fréquence, du

comité technique 77 de la CEI: Compatibilité électromagnétique.

Le texte de cet amendement est issu des documents suivants:

FDIS Rapport de vote
77A/389/FDIS 77A/399/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2006. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.

Page 2
SOMMAIRE
Remplacer le titre de la figure 1 et ajouter le titre de la figure B.1 comme suit:
Figure 1 – Schéma fonctionnel du flickermètre de la CEI
Figure B.1 – Variation de tension rectangulaire ΔV/V = 40 %, 8,8 Hz, 17,6 variations/seconde
Ajouter, après les figures, les titres des tableaux suivants:
Tableau 1 – Réponse normalisée d’un flickermètre pour des fluctuations sinusoïdales
de la tension
Tableau 2 – Réponse normalisée d’un flickermètre pour des fluctuations rectangulaires
de la tension
Tableau 3 – Plage des tensions d’entrée assignées
Tableau 4 – Relation entre les valeurs du sélecteur de gammes et les niveaux de sensation
Tableau 5 – Spécifications d’essais pour la classification du flickermètre
Tableau 6 – Essais d’isolement pour l’entrée et les raccordements à la source
d’alimentation
Tableau 7 – Essais pour l’évaluation de l’immunité aux perturbations électromagnétiques
Tableau 8 – Valeurs indicatives des paramètres de lampes
Ajouter, après le titre de l’annexe A, les nouveaux éléments suivants:
Annexe B – Signification du ΔV/V et du nombre de variations de tension
Bibliographie
61000-4-15 Amend. 1  IEC:2003 – 3 –

FOREWORD
This amendment has been prepared by subcommittee 77A: Low-frequency phenomena, of IEC

technical committee 77: Electromagnetic compatibility.

The text of this amendment is based on the following documents:

FDIS Report on voting
77A/389/FDIS 77A/399/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Replace the title of Figure 1 and add the title of Figure B.1 as follows:
Figure 1 – Functional diagram of IEC flickermeter
Figure B.1 − Rectangular voltage change ΔV/V = 40 %, 8,8 Hz, 17,6 changes/second
Add, after the figures, the following table titles:
Table 1 – Normalized flickermeter response for sinusoidal voltage fluctuations
Table 2 – Normalized flickermeter response for rectangular voltage fluctuations
Table 3 – Ranges of rated input voltage
Table 4 – Relationship between the range selector values and sensation levels
Table 5 – Test specifications for flickermeter classifier
Table 6 – Insulation tests for input and power supply connection
Table 7 – Immunity assessment tests to electromagnetic interference
Table 8 – Indicative values for the parameters of lamps
Add, after the title of Annex A, the following new elements:
Annex B – Meaning of ΔV/V and number of voltage changes
Bibliography
– 4 – 61000-4-15 Amend.1 © CEI:2003

Page 8
1 Domaine d’application et objet

Remplacer le second alinéa par ce qui suit:

Cette section s’appuie en partie sur les travaux du Groupe de Travail « Perturbations » de

l’Union Internationale de l’Electrothermie (UIÉ), en partie sur les travaux d’IEEE et en partie

sur les travaux effectués au sein de la CEI. Dans cette section, les spécifications du

flickermètre ne concernent que des mesures effectuées sous 230 V, 50 Hz et des mesures

effectuées sous 120 V, 60 Hz; les spécifications concernant d’autres tensions et d’autres
fréquences sont à l’étude.
2 Références normatives
Supprimer, de la liste existante, la norme suivante:
CEI 61000-3-3:1994, Compatibilité électromagnétique (CEM) – Partie 3: Limites – Section 3:
Limitation des fluctuations de tension et du flicker dans les réseaux basse tension pour les
équipements ayant un courant appelé ≤ 16 A
Page 12
3.2 Bloc 1 – Adaptateur de tension d’entrée et circuit de vérification d’étalonnage
Supprimer la note existante.
3.4 Blocs 3 et 4 – Filtres de pondération, élévation au carré et lissage
Modifier la première phrase du troisième alinéa comme suit:
Le second filtre est un filtre de pondération qui simule la combinaison de la réponse spectrale
d’une lampe à remplissage de gaz inerte à filament bi-spirale (60 W – 230 V et/ou 60 W –
120 V) avec la réponse de l’œil humain pour des fluctuations sinusoïdales de tension.
Modifier la première phrase de la note à la suite du troisième alinéa comme suit:
NOTE Une lampe à filament servant de référence pour les réseaux 100 V aurait une réponse en fréquence

différente et nécessiterait donc un réglage du filtre de pondération.
Page 16
4.1 Réponse analogique
Ajouter, à la fin du premier alinéa, la phrase suivante:
Les tableaux 1 et 2 donnent des valeurs pour les réseaux 120 V/60 Hz et 230 V/50 Hz.

61000-4-15 Amend. 1  IEC:2003 – 5 –

Page 9
1 Scope and object
Replace the second paragraph by the following:

This section is based partly on work by the “Disturbances” Working Group of the International

Union for Electroheat (UIE), partly on work of the IEEE, and partly on work within IEC itself.

The flickermeter specifications in this section relate only to measurements of 230 V, 50 Hz

inputs and 120 V, 60 Hz inputs; specifications for other voltages and other frequencies are

under consideration.
2 Normative references
Delete, from the existing list, the following standard:
IEC 61000-3-3:1994, Electromagnetic compatibility (EMC) – Part 3: Limits – Section 3:
Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with
rated current ≤ 16 A
Page 13
3.2 Block 1 – Input voltage adaptor and calibration checking circuit
Delete the existing note.
3.4 Blocks 3 and 4 – Weighting filters, squaring and smoothing
Change the first sentence of the third paragraph to read as follows:
The second filter is a weighting filter block that simulates the frequency response to sinusoidal
voltage fluctuations of a coiled filament gas-filled lamp (60 W – 230 V and/or 60 W – 120 V)
combined with the human visual system.
Change the first sentence of the note following the third paragraph to read:

NOTE A reference filament lamp for 100 V systems would have a different frequency response and would require
a corresponding adjustment of the weighting filter.
Page 17
4.1 Analogue response
Add to the end of the first paragraph the following new sentence:
Tables 1 and 2 give values for 120 V/60 Hz and 230 V /50 Hz systems.

– 6 – 61000-4-15 Amend.1 © CEI:2003

Remplacer, à la page 18, les tableaux 1 et 2 existants par les suivants:

Tableau 1 – Réponse normalisée d’un flickermètre pour des fluctuations

sinusoïdales de la tension
(amplitude relative de la fluctuation de tension d’entrée ΔV/V

pour une unité de perceptibilité en sortie 5)

Fluctuation de tension Fluctuation de tension

Hz % Hz %
Lampe 120 V Lampe 230 V Lampe 120 V Lampe 230 V

réseau 60 Hz réseau 50 Hz réseau 60 Hz réseau 50 Hz

0,5 2,457 2,340 10,0 0,339 0,260
1,0 1,463 1,432 10,5 0,355 0,270
1,5 1,124 1,080 11,0 0,374 0,282
2,0 0,940 0,882 11,5 0,394 0,296
2,5 0,814 0,754 12,0 0,420 0,312
3,0 0,716 0,654 13,0 0,470 0,348
3,5 0,636 0,568 14,0 0,530 0,388
4,0 0,569 0,500 15,0 0,593 0,432
4,5 0,514 0,446 16,0 0,662 0,480
5,0 0,465 0,398 17,0 0,737 0,530
5,5 0,426 0,360 18,0 0,815 0,584
6,0 0,393 0,328 19,0 0,897 0,640
6,5 0,366 0,300 20,0 0,981 0,700
7,0 0,346 0,280 21,0 1,071 0,760
7,5 0,332 0,266 22,0 1,164 0,824
8,0 0,323 0,256 23,0 1,262 0,890
8,8 0,321 0,250 24,0 1,365 0,962
9,5 0,330 0,254 25,0 1,472 1,042
33,33 Essai non 2,130
prescrit
40,0 4,424 Essai non
prescrit
61000-4-15 Amend. 1  IEC:2003 – 7 –

Replace, on page 19, the existing Tables 1 and 2 by the following new tables:

Table 1 – Normalized flickermeter response for sinusoidal

voltage fluctuations
(input relative voltage fluctuation ΔV/V for one unit of perceptibility at output 5)

Voltage fluctuation Voltage fluctuation

Hz % Hz %
120-V lamp 230-V lamp 120-V lamp 230-V lamp

60 Hz system 50 Hz system 60 Hz system 50 Hz system

0,5 2,457 2,340 10,0 0,339 0,260
1,0 1,463 1,432 10,5 0,355 0,270
1,5 1,124 1,080 11,0 0,374 0,282
2,0 0,940 0,882 11,5 0,394 0,296
2,5 0,814 0,754 12,0 0,420 0,312
3,0 0,716 0,654 13,0 0,470 0,348
3,5 0,636 0,568 14,0 0,530 0,388
4,0 0,569 0,500 15,0 0,593 0,432
4,5 0,514 0,446 16,0 0,662 0,480
5,0 0,465 0,398 17,0 0,737 0,530
5,5 0,426 0,360 18,0 0,815 0,584
6,0 0,393 0,328 19,0 0,897 0,640
6,5 0,366 0,300 20,0 0,981 0,700
7,0 0,346 0,280 21,0 1,071 0,760
7,5 0,332 0,266 22,0 1,164 0,824
8,0 0,323 0,256 23,0 1,262 0,890
8,8 0,321 0,250 24,0 1,365 0,962
9,5 0,330 0,254 25,0 1,472 1,042
33,33 Test not required 2,130
40,0 4,424 Test not
required
– 8 – 61000-4-15 Amend.1 © CEI:2003

Tableau 2 – Réponse normalisée d’un flickermètre
pour des fluctuations rectangulaires de la tension
(amplitude relative de la fluctuation de tension d’entrée ΔV/V

pour une unité de perceptibilité en sortie 5)

Fluctuation de tension Fluctuation de tension

Hz % Hz %
Lampe 120 V Lampe 230 V Lampe 120 V Lampe 230 V

réseau 60 Hz réseau 50 Hz réseau 60 Hz réseau 50 Hz

0,5 0,600 0,514 10,0 0,264 0,205

1,0 0,547 0,471 10,5 0,280 0,213
1,5 0,504 0,432 11,0 0,297 0,223
2,0 0,471 0,401 11,5 0,309 0,234
2,5 0,439 0,374 12,0 0,323 0,246
3,0 0,421 0,355 13,0 0,369 0,275
3,5 0,407 0,345 14,0 0,411 0,308
4,0 0,394 0,333 15,0 0,459 0,344
4,5 0,371 0,316 16,0 0,513 0,376
5,0 0,349 0,293 17,0 0,580 0,413
5,5 0,323 0,269 18,0 0,632 0,452
6,0 0,302 0,249 19,0 0,692 0,498
6,5 0,282 0,231 20,0 0,752 0,546
7,0 0,269 0,217 21,0 0,818 0,586
7,5 0,258 0,207 22,0 0,853 0,604
8,0 0,255 0,201 23,0 0,946 0,680
8,8 0,253 0,199 24,0 1,072 0,743
9,5 0,257 0,200 33,33 Essai non 1,67
prescrit
40,0 3,46 Essai non
prescrit
61000-4-15 Amend. 1  IEC:2003 – 9 –

Table 2 – Normalized flickermeter response for rectangular
voltage fluctuations
(input relative voltage fluctuation ΔV/V for one unit of perceptibility at output 5)

Voltage fluctuation Voltage fluctuation

Hz % Hz %
120 V lamp 230 V lamp 120 V lamp 230 V lamp

60 Hz system 50 Hz System 60 Hz system 50 Hz system

0,5 0,600 0,514 10,0 0,264 0,205

1,0 0,547 0,471 10,5 0,280 0,213

1,5 0,504 0,432 11,0 0,297 0,223
2,0 0,471 0,401 11,5 0,309 0,234
2,5 0,439 0,374 12,0 0,323 0,246
3,0 0,421 0,355 13,0 0,369 0,275
3,5 0,407 0,345 14,0 0,411 0,308
4,0 0,394 0,333 15,0 0,459 0,344
4,5 0,371 0,316 16,0 0,513 0,376
5,0 0,349 0,293 17,0 0,580 0,413
5,5 0,323 0,269 18,0 0,632 0,452
6,0 0,302 0,249 19,0 0,692 0,498
6,5 0,282 0,231 20,0 0,752 0,546
7,0 0,269 0,217 21,0 0,818 0,586
7,5 0,258 0,207 22,0 0,853 0,604
8,0 0,255 0,201 23,0 0,946 0,680
8,8 0,253 0,199 24,0 1,072 0,743
9,5 0,257 0,200 33,33 Test not 1,67
required
40,0 3,46 Test
not required
– 10 – 61000-4-15 Amend.1 © CEI:2003

Page 18
4.2 Transformateur d’entrée
Remplacer, à la page 20, le tableau 3 existant par le tableau suivant:

Tableau 3 – Plage des tensions d’entrée assignées

Tension d’entrée assignée +20 %
−−−−30 %
V eff. V eff. V eff.
57,7 40 68
100 70 120
115 80,5 130
120 84 144
127 89 152
160 112 192
220 154 264
230 161 276
240 168 288
380 266 456
400 280 480
420 294 504
Page 20
4.3 Adaptateur de tension
Modifier la première phrase pour supprimer la référence à la valeur de 50 Hz comme suit:
A l’entrée du bloc 2, ce circuit doit maintenir la valeur efficace de tension modulée à un niveau
constant…
4.4 Générateur interne de vérification de l’étalonnage
Modifier la première phrase comme suit:

Le générateur interne doit fournir une onde sinusoïdal à la fréquence du réseau, modulée par
une onde rectangulaire de (50/17) Hz = 2,94 Hz pour les réseaux à 50 Hz et par une onde
rectangulaire de (60/17) Hz = 3,53 Hz pour les réseaux à 60 Hz.
Page 22
4.6 Filtres de pondération
Remplacer le deuxième alinéa par l’alinéa et la note suivants:
Le filtre suppresseur des éléments indésirables comprend une section passe-haut du premier
ordre (la fréquence de coupure recommandée à 3 dB est environ 0,05 Hz) et une section
ème
passe-bas, pour laquelle on suggère d’employer un filtre Butterworth de 6 ordre avec une
fréquence de coupure de 35 Hz à 3 dB pour les réseaux 230 V/50 Hz et un filtre Butterworth de
ème
6 ordre avec une fréquence de coupure de 42 Hz à 3 dB pour les réseaux 120 V/ 60 Hz.

61000-4-15 Amend. 1  IEC:2003 – 11 –

Page 19
4.2 Input transfer
Replace, on page 21, the existing table 3 by the following table:

Table 3 – Ranges of rated input voltage

Rated input voltage –30 % +20 %

V r.m.s. V r.m.s. V r.m.s.
57,7 40 68
100 70 120
115 80,5 130
120 84 144
127 89 152
160 112 192
220 154 264
230 161 276
240 168 288
380 266 456
400 280 480
420 294 504
Page 21
4.3 Voltage adaptor
Change the first sentence to delete the 50 Hz reference as shown:
This circuit shall keep the r.m.s. level
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.