Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol

General Information

Status
Published
Publication Date
11-Dec-2006
Current Stage
PPUB - Publication issued
Start Date
15-Feb-2007
Completion Date
12-Dec-2006
Ref Project

Relations

Buy Standard

Standard
IEC 62056-46:2002/AMD1:2006 - Amendment 1 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL IEC


STANDARD 62056-46


  2002



AMENDMENT 1

2006-12

Amendment 1
Electricity metering –
Data exchange for meter reading,
tariff and load control –
Part 46:
Data link layer using HDLC protocol
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale H

International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 1 ----------------------
– 2 – 62056-46 Amend. 1 © IEC:2006(E)
FOREWORD
This amendment has been prepared by IEC technical committee 13: Equipment for electrical
energy measurement and load control.
The text of this amendment is based on the following documents:
CDV Report on voting
13/1376/FDIS 13/1401/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

_____________
INTRODUCTION
This Amendment takes into account that in the third edition of ISO/IEC 13239, frame type 3
has been added as Annex H.4, as requested by IEC TC 13 WG 14, and that second editions
of some parts of the IEC 62056 series are under preparation.
It specifies now that a secondary station may use more than one addressing scheme.
It contains some changes concerning the negotiation of the maximum information length field
HDLC parameter for better efficiency.
References have been updated and some editorial errors have also been corrected.
Page 6
2 Normative references
Add the following reference:
IEC 62051-1:2004, Electricity metering – Data exchange for meter reading, tariff and load
control – Glossary of Terms – Part 1, Terms related to data exchange with metering
equipment using DLMS/COSEM

---------------------- Page: 2 ----------------------
62056-46 Amend. 1 © IEC:2006(E) – 3 –
Amend the following references:
IEC 62056-53:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 53: COSEM Application layer
IEC 62056-61:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 61: OBIS Object identification system
IEC 62056-62:2006, Electricity metering – Data exchange for meter reading, tariff and load
control – Part 62: Interface classes
ISO/IEC 13239:2002, Information technology – Telecommunications and information
exchange between systems – High-level data link control (HDLC) procedures

Page 7
3 Terms, definitions and abbreviations
Replace the sentence by the following:
For the purposes of this document, the definitions given in IEC 60050-300, IEC 62051 and
IEC 62051-1 apply.

Page 8
4.3 Specification method
Delete, on page 9,in the fourth bullet point “(e.g. Physical_Connection_Type)”.
Add a line break, below the Note, before the second sentence “The protocol specification….”
so that this sentence belongs to the three bullet points following.
Replace, in the ninth bullet point ”(User data subfield)” by ”(Information field, User data
subfield)”.
Page 14
5.2.2.2 DL-DISCONNECT.request
Replace, in the service primitive definition ”User information” by ”User_Information”.
Replace, in the paragraph following the service primitive definition, ”User_information” by
”User_Information”.
5.2.2.3 DL-DISCONNECT.indication
Replace, in the service primitive definition, ”User Information” by ”User_Information”.
Replace, on page 15, in the paragraph above ”Use”, ”User Information” by “User_Information”.
5.2.2.4 DL-DISCONNECT.response
Replace, on page 15, in the paragraph following the service primitive definition,

---------------------- Page: 3 ----------------------
– 4 – 62056-46 Amend. 1 © IEC:2006(E)
”The Destination_MSAP and Source_MSAP parameters specify the local and remote…”
by
”The Destination_MSAP and Source_MSAP parameters specify the remote and local…”

Page 17
DL-DATA.request
Replace, on page 18, in the first paragraph,
“The Source_LSAP and Destination_LSAP parameters specify the referenced data link…”
by
“The Destination_LSAP and Source_LSAP parameters specify the referenced data link…”
Replace, in the second paragraph,
“The Source_MSAP and Destination_MSAP parameters specify the local and remote…”
by
“The Destination_MSAP and Source_MSAP parameters specify the remote and local …”
Page 18
5.2.3.3 DL-DATA.indication
Replace,
...

Questions, Comments and Discussion