IEC 62366-1:2015/COR1:2016
(Corrigendum)Corrigendum 1 - Medical devices - Part 1: Application of usability engineering to medical devices
Corrigendum 1 - Medical devices - Part 1: Application of usability engineering to medical devices
Corrigendum 1 - Dispositifs médicaux - Partie 1: Application de l'ingénierie de l'aptitude à l'utilisation aux dispositifs médicaux
General Information
Relations
Standards Content (Sample)
IEC 2016
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 62366-1 IEC 62366-1
Edition 1.0 2015-02 Édition 1.0 2015-02
Medical devices – Dispositifs médicaux –
Part 1: Application of usability engineering to Partie 1: Application de l'ingénierie de l'aptitude
medical devices à l'utilisation aux dispositifs médicaux
CO RRI G ENDU M 1
C.1 General C.1 Généralités
Replace, in the existing
...
This May Also Interest You
IEC 60601-2-76:2018 applies to the basic safety and essential performance of low energy ionized gas haemostasis equipment.
Hazards inherent in the intended physiological function of ME Equipment or ME Systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard.
This particular standard amends and supplements IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.
- Standard53 pagesEnglish and French languagesale 15% off
- Standard107 pagesEnglish and French languagesale 15% off
- Standard8 pagesEnglish and French languagesale 15% off
IEC 60364-7-721:2017 lays down particular requirements applying to electrical circuits and equipment intended for the use of the caravan for habitation purposes. This new edition includes the following significant technical changes with respect to the previous edition:
- a minimum height of not less than 500 mm above the base of the cylinders is now required for cables passing through the gas cylinder compartment;
- it is now required that each independent installation shall be provided with its own main isolating switch which shall disconnect all live conductors and which shall be suitably placed in a readily accessible location in the caravan.
- Standard25 pagesEnglish languagesale 15% off
- Standard51 pagesEnglish and French languagesale 15% off
IEC TS 62965:2016 which is a Technical Specification, specifies a minimum set of dimensional requirements for fusion splice on connectors (FSOCs) ferrule assemblies and the interface dimensions of splicing tools to ensure that a compliant ferrule assembly is compatible with a compliant fusion splicer. This fusion splicer interface also provides an example of the dimensional requirements for a universal holder, into which an FSOC can be mounted. This fusion splicer interface applies to FSOCs with a cylindrical ferrule of 2,5 mm diameter or 1,25 mm diameter. Keywords: FSOC, fusion splicer interface
- Technical specification22 pagesEnglish and French languagesale 15% off
IEC/IEEE 62582-1:2024 is available as IEC/IEEE 62582-1:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC/IEEE 62582-1:2024 contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring.
IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible.
- Standard21 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish languagesale 15% off
IEC/IEEE 63332-387:2024 defines the criteria for the application and testing of diesel generator (DG) units used as safety class standby power supplies in nuclear facilities. In general, the standard applies to new nuclear facilities as well as for upgrading or back-fitting of existing facilities. Existing facilities can voluntarily adopt the requirements to enhance the performance capabilities and reliability of the installed DG units. The standard can be used in applications where highly reliable onsite alternating current (AC) power source is required to maintain plant safety following an event with potential loss of offsite power for an extended duration.
This document provides the principal design criteria, the design features, testing, and qualification requirements for the individual DG units that enable them to meet their functional requirements as a part of the standby power supply under the conditions produced by the design basis events catalogued in the plant safety analysis.
- Standard139 pagesEnglish and French languagesale 15% off
IEC TR 63368:2024 provides guidance on off-site real-time simulation tests of control and protection (C&P) systems for HVDC power transmission systems. The off-site real-time simulation tests are carried out after the testing of C&P devices and prior to on-site system tests.
This document covers point-to-point, back-to-back, and multi-terminal HVDC systems of line commutated converters (LCC), voltage-sourced converters (VSC) and hybrid HVDC technologies.
In order to provide practical guidance for the functional performance tests of HVDC power transmission systems, this document covers the test environment, the contents and methods of functional performance tests, and the test report.
- Technical report30 pagesEnglish languagesale 15% off
IEC 62899-301-3:2024 defines measurement terms and methods related to the shape errors of printing plate rollers. Measurement terms include radius, total run-out, and three kinds of shape errors of printing plate rollers that are axial deviation, radial deviation, and cross-sectional deviation. The remaining shape error excluding the three errors mentioned above is defined as a residual shape error.
This document applies to printing plate rollers with or without patterns while excluding the pattern area for the measurement.
- Standard24 pagesEnglish languagesale 15% off
IEC TR 63484:2024 information about fungal growth on the outer sheath of optical fibre cables and on the inner components of the cable. It also provides guidance for specifying fungus resistance performance of optical cable outer sheath and internal cable components, including recommendations for fungus resistance test method as well as evaluation after test.
This document applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to hybrid telecommunication cables having a combination of both optical fibres and electrical conductors.
Since conditions suitable for fungal growth include high relative humidity and a warm atmosphere, the document is applicable to optical cables intended for transportation, storage and use under such environment over certain period, for instance, some days at least.
- Technical report15 pagesEnglish languagesale 15% off
IEC TS 63331:2024 applies to electric dishwashers for household and similar use that are supplied with hot and/or cold water.
This document deals with measurement procedures regarding the reduction of microbial contamination resulting from the use of electric dishwashers for household and similar use.
This document specifies methods that enable reproducible measurements. These derived measurement results can only be used for a relative statement. Absolute statements, i.e. health-related claims or conclusions about prevention or treatment of a disease or health improvement, are reserved for explicit regulatory action after a medical assessment.
This document does not apply to appliances intended to be used in medical, veterinary, or pharmaceutical applications.
This document does not address sanitization, disinfection or sterilization measures.
The dishwashing process is a complex operation consisting of cleaning dish items and cleaning the dishwasher itself. This document only focusses on the dish items to be cleaned.
- Technical specification32 pagesEnglish languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.