ISO 19232-5:2018
(Main)Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators
Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators
This document specifies a method of determining the total image unsharpness and basic spatial resolution of radiographs and radioscopic images. The IQI with up to 13 wire pairs can be used effectively with tube voltages up to 600 kV. The IQI with more than 13 wire pairs can be used effectively at tube voltages lower than 225 kV. When using source voltages in the megavolt range, it is possible that the results are not be completely satisfactory.
Essais non destructifs — Qualité d'image des radiogrammes — Partie 5: Détermination de l'indice de flou de l'image et de la résolution spatiale de base à l'aide d'indicateurs de qualité d'image duplex à fils
Le présent document spécifie une méthode de détermination de l'indice de flou total de l'image et de la résolution spatiale de base des radiogrammes et des images radioscopiques. L'IQI avec jusqu'à 13 paires de fils peut être utilisé efficacement avec des tensions de tube pouvant atteindre 600 kV. L'IQI avec plus de 13 paires de fils peut être utilisé efficacement avec des tensions de tube inférieures à 225 kV. En cas d'utilisation de tensions de source dans la plage des mégavolts, les résultats peuvent ne pas être entièrement satisfaisants.
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 19232-5
Third edition
2018-08
Non-destructive testing — Image
quality of radiographs —
Part 5:
Determination of the image
unsharpness and basic spatial
resolution value using duplex wire-
type image quality indicators
Essais non destructifs — Qualité d'image des radiogrammes —
Partie 5: Détermination de l'indice de flou de l'image et de la
résolution spatiale de base à l'aide d'indicateurs de qualité d'image
duplex à fils
Reference number
ISO 19232-5:2018(E)
©
ISO 2018
---------------------- Page: 1 ----------------------
ISO 19232-5:2018(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2018
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2018 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 19232-5:2018(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Specification of duplex wire-type IQI . 3
4.1 Dimensions, manufacture, and marking . 3
4.1.1 Dimensions and material . 3
4.1.2 Manufacture . 4
4.1.3 Marking . 4
4.2 Declaration of conformity. 4
5 Use of duplex wire . 4
5.1 General . 4
5.2 Visual evaluation . 5
5.3 Evaluation of digital images with profile function . 5
5.4 Evaluation of digital images with profile function by interpolation . 5
5.5 Image quality classes . 6
5.6 Application of duplex wire IQI . 6
6 High resolution IQI with increased measurement range . 8
7 Documentation .
...
NORME ISO
INTERNATIONALE 19232-5
Troisième édition
2018-08
Essais non destructifs — Qualité
d'image des radiogrammes —
Partie 5:
Détermination de l'indice de flou de
l'image et de la résolution spatiale de
base à l'aide d'indicateurs de qualité
d'image duplex à fils
Non-destructive testing — Image quality of radiographs —
Part 5: Determination of the image unsharpness and basic spatial
resolution value using duplex wire-type image quality indicators
Numéro de référence
ISO 19232-5:2018(F)
©
ISO 2018
---------------------- Page: 1 ----------------------
ISO 19232-5:2018(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2018
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2018 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 19232-5:2018(F)
Sommaire Page
Avant-propos .iv
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Spécification de l'IQI duplex à fils . 3
4.1 Dimensions, fabrication et marquage . 3
4.1.1 Dimensions et matériau. 3
4.1.2 Fabrication . 4
4.1.3 Marquage . 4
4.2 Déclaration de conformité . 4
5 Utilisation de l’IQI duplex à fils . 5
5.1 Généralités . 5
5.2 Évaluation visuelle . 5
5.3 Évaluation d’images numériques avec une fonction de profil . 6
5.4 Évaluation d’images numériques avec une fonction de profil par interpolation. 6
5.5 Classes de qualité d’image . 7
5.6 Application de l’IQI duplex à fils . 7
6 IQI à haute résolution avec plage de mesure élargie . 9
7 Documentation .
...