Acoustics — Determination of sound immission from sound sources placed close to the ear — Part 1: Technique using a microphone in a real ear (MIRE technique)

ISO 11904-1:2002 specifies basic framework measurement methods for sound immissions from sound sources placed close to the ear. These measurements are carried out with miniature or probe microphones inserted in the ear canals of human subjects. The measured values are subsequently converted into corresponding free-field or diffuse-field levels. The results can be given as free-field related or diffuse-field related equivalent continuous A-weighted sound pressure levels. The technique is denoted the microphone-in-real-ear technique (MIRE technique). ISO 11904-1:2002 is applicable to exposure from sources close to the ear, for example during equipment tests or at the workplace by earphones or hearing protectors with audio communication facilities. ISO 11904-1:2002 is applicable in the frequency range from 20 Hz to 16 000 Hz.

Acoustique — Détermination de l'exposition sonore due à des sources placées à proximité de l'oreille — Partie 1: Technique du microphone placé dans une oreille réelle (technique MIRE)

L'ISO 11904-1:2002 spécifie des méthodes de mesure générales d'émissions sonores des sources de bruit placées à proximité de l'oreille. Ces mesurages sont effectués au moyen de microphones miniatures ou de sondes microphoniques insérés dans les conduits auditifs de sujets humains. Les valeurs mesurées sont ensuite converties en niveaux ramenés au champ libre ou au champ diffus correspondants. Les résultats sont donnés sous forme de niveaux de pression acoustique continus équivalents pondérés A relatifs au champ libre ou au champ diffus. La technique est appelée technique du microphone dans l'oreille réelle (technique MIRE). L'ISO 11904-1:2002 peut s'appliquer à l'exposition à des sources placées à proximité de l'oreille, par exemple, au cours d'essais d'équipements ou au poste de travail, avec par exemple des écouteurs ou des protecteurs individuels contre le bruit munis de moyens de communication audio. L'ISO 11904-1:2002 s'applique dans la gamme de fréquences comprises entre 20 Hz et 16 000 Hz.

General Information

Status
Published
Publication Date
09-Oct-2002
Technical Committee
Drafting Committee
Current Stage
9093 - International Standard confirmed
Completion Date
25-Mar-2024
Ref Project

Relations

Buy Standard

Standard
ISO 11904-1:2002 - Acoustics -- Determination of sound immission from sound sources placed close to the ear
English language
20 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11904-1:2002 - Acoustique -- Détermination de l'exposition sonore due a des sources placées a proximité de l'oreille
French language
21 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 11904-1
First edition
2002-10-01
Acoustics — Determination of sound
immission from sound sources placed
close to the ear —
Part 1:
Technique using a microphone in a real ear
(MIRE technique)
Acoustique — Détermination de l'exposition sonore due à des sources
sonores placées à proximité de l'oreille —
Partie 1: Technique du microphone placé dans une oreille réelle (technique
MIRE)
Reference number
©
ISO 2002
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not
be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this
file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this
area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2002
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body
in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
ii © ISO 2002 – All rights reserved

Contents Page
Foreword . iv
Introduction. v
1 Scope. 1
2 Normative references. 1
3 Terms and definitions. 2
4 Measurement principle. 3
5 Instrumentation. 3
5.1 Ear canal microphone. 3
5.2 Reference field microphone. 4
5.3 Check of calibration. 4
5.4 Filters. 4
6 Subjects. 4
7 Use of ear canal microphone . 4
7.1 Choice of ear canal measurement position. 4
7.2 Mounting of microphones . 6
7.3 Safety. 6
8 Determination of free-field or diffuse-field related equivalent continuous A-weighted sound
pressure level . 6
8.1 Measurement of ear canal sound pressure level. 6
8.2 Conversion to free-field or diffuse-field related sound pressure level. 7
8.3 A-weighting and summation. 7
9 Free-field and diffuse-field frequency responses for selected ear canal measurement positions . 7
10 Determination of free-field or diffuse-field frequency responses. 7
10.1 General. 7
10.2 Measurement principle. 9
10.3 Establishment of a free reference sound field . 9
10.4 Establishment of a quasi-free reference sound field . 9
10.5 Establishment of a diffuse reference sound field. 9
10.6 Measurement of the reference sound field. 9
10.7 Measurement of ear canal sound pressure level in reference sound field . 9
10.8 Determination of free-field or diffuse-field frequency response.10
10.9 Simplifications in specific cases . 10
10.10 Optional check of the measurement arrangement . 10
11 Test report. 10
Annex A (informative) Example of sources of measurement uncertainty . 11
Annex B (informative) Example of an uncertainty analysis . 17
Bibliography. 19

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
The main task of technical committees is to prepare International Standards. Draft International Standards adopted
by the technical committees are circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11904-1 was prepared by Technical Committee ISO/TC 43, Acoustics.
ISO 11904 consists of the following parts, under the general title Acoustics — Determination of sound immission
from sound sources placed close to the ear:
 Part 1: Technique using a microphone in a real ear (MIRE technique)
 Part 2: Technique using a manikin (manikin technique)
Annexes A and B of this part of ISO 11904 are for information only.
iv © ISO 2002 – All rights reserved

Introduction
ISO 11904 is a series of standards which specify methods for the determination of sound immissions from sources
located close to the ear, in which situations the sound pressure level measured at the position of the exposed
person (but with the person absent) does not adequately represent the sound exposure.
In order to make it possible to assess the exposure by means of well established criteria, the exposure of the ear is
measured and subsequently converted into a corresponding free-field or diffuse-field level. The result is given as
free-field related or diffuse-field related equivalent continuous A-weighted sound pressure level, L or
,
FF H,Aeq
L when ISO 11904-1 is used, or L or L when ISO 11904-2 is used.
DF,H,Aeq FF,M,Aeq DF,M,Aeq
ISO 11904-1 describes measurements carried out using miniature or probe microphones inserted in the ears of
human subjects (microphone in real ear, MIRE technique). ISO 11904-2 describes measurements carried out using
a manikin equipped with ear simulators including microphones (manikin technique).
ISO 11904 may, for instance, be applied to equipment tests and the determination of noise exposure at the
workplace where, in the case of exposure from sources close to the ears, the sound pressure level measured at
the position of the exposed person (but with the person absent) does not adequately represent the sound
exposure. Examples of applications are head- and earphones used to reproduce music or speech, whether at the
workplace or during leisure, nailguns used close to the head, and combined exposure from a close-to-ear sound
source and an external sound field.
When specific types of equipment are to be tested (e.g. portable cassette players or hearing protectors provided
with radio receivers), test signals suitable for this particular type of equipment have to be used. Neither such test
signals nor the operating conditions of the equipment are included in ISO 11904 but might be specified in other
standards.
When workplace situations are measured, the various noise sources contributing to the immission should be
identified. Operating conditions for machinery and equipment used might be specified in other standards.
Both parts of ISO 11904 strive for the same result: a mean value for a population of the free-field or the diffuse-field
related level. ISO 11904-1 does this by specifying the mean of measurements on a number of human subjects;
ISO 11904-2 does this by using a manikin, which aims at reproducing the acoustical effects of an average human
adult. However, the two methods yield different measurement uncertainties which can influence the choice of
method. Only the method described in ISO 11904-1 gives results which indicate the variance in a human
population. Information on the uncertainties is given in annexes A and B.
When using the MIRE technique for measurement of sound from earphones of insert and stethoscopic types,
practical problems can occur with the positioning of microphones in the ear canal. When using the manikin
technique, the head- or earphone has to be coupled to the pinna simulator and ear canal extension as far as
possible in the way it is coupled to the human ear. In cases where head- or earphones or other objects touch the
pinna, a possible deviation in stiffness or shape of the artificial pinna from human pinnae has a significant impact
on the result and can even make the results invalid.
An overview of the differences of the two parts of ISO 11904 is given in Table 0.1.
Table 0.1 — Overview of differences between MIRE and manikin techniques
Parameter ISO 11904-1 ISO 11904-2
Type of method Microphone in real ear technique Manikin technique
Limitation of the With earphones of insert and stethoscopic A proper coupling may not always be obtained
method type, practical problems can occur with if the artificial pinna deviates from human
positioning of microphones in the ear canal. pinnae in stiffness or shape.
In some cases the exposed person cannot be
replaced by a manikin, e.g. if the person has
to operate equipment.
Main issues — Number of subjects — Similarity of manikin to human subjects
affecting accuracy
When tabulated values are used for ∆L or — Calibration of manikin
FF,H
∆L :
DF,H
 calibration of ear canal microphone
 accuracy in positioning of microphones in
the ear canal
When individual values are used for ∆L or
FF,H
∆L :
DF,H
 quality of reference sound field
 stability of sensitivity and frequency
response as well as position of ear canal
microphone
Frequency range 20 Hz to 16 kHz 20 Hz to 10 kHz

vi © ISO 2002 – All rights reserved

INTERNATIONAL STANDARD ISO 11904-1:2002(E)

Acoustics — Determination of sound immission from sound
sources placed close to the ear —
Part 1:
Technique using a microphone in a real ear (MIRE technique)
1 Scope
This part of ISO 11904 specifies basic framework measurement methods for sound immission from sound sources
placed close to the ear. These measurements are carried out with miniature or probe microphones inserted in the
ear canals of human subjects. The measured values are subsequently converted in
...


NORME ISO
INTERNATIONALE 11904-1
Première édition
2002-10-01
Acoustique — Détermination de
l'exposition sonore due à des émissions
sonores placées à proximité de
l'oreille —
Partie 1:
Technique du microphone placé dans
une oreille réelle (technique MIRE)
Acoustics — Determination of sound immission from sound sources
placed close to the ear —
Part 1: Technique using a microphone in a real ear (MIRE technique)

Numéro de référence
©
ISO 2002
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.

©  ISO 2002
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Version française parue en 2003
Publié en Suisse
ii © ISO 2002 — Tous droits réservés

Sommaire Page
Avant-propos. iv
Introduction . v
1 Domaine d'application. 1
2 Références normatives. 1
3 Termes et définitions . 2
4 Principe de mesurage. 3
5 Appareillage. 4
5.1 Microphone de conduit auditif. 4
5.2 Microphone de référence . 4
5.3 Vérification de l'étalonnage . 4
5.4 Filtres. 4
6 Sujets. 4
7 Utilisation du microphone de conduit auditif. 4
7.1 Choix du point de mesure du conduit auditif.4
7.2 Fixation du microphone . 5
7.3 Sécurité . 5
8 Détermination du niveau de pression acoustique continu équivalent pondéré A relatif au
champ libre ou au champ diffus. 7
8.1 Mesurage du niveau de pression acoustique dans le conduit auditif. 7
8.2 Conversion en niveau de pression acoustique relatif au champ libre ou au champ diffus. 7
8.3 Pondération A et sommation . 7
9 Réponses en fréquence en champ libre et en champ diffus pour les points de mesure du
conduit auditif sélectionnés. 8
10 Détermination des réponses en fréquence en champ libre ou en champ diffus . 8
10.1 Généralités. 8
10.2 Principe de mesurage. 8
10.3 Établissement d'un champ acoustique de référence libre . 8
10.4 Établissement d'un champ acoustique de référence quasi libre. 8
10.5 Établissement d'un champ acoustique de référence diffus . 8
10.6 Mesurage du champ acoustique de référence. 9
10.7 Mesurage du niveau de pression acoustique dans le conduit auditif dans le champ
acoustique de référence. 10
10.8 Détermination de la réponse en fréquence du champ libre ou du champ diffus. 10
10.9 Simplifications dans des cas particuliers . 10
10.10 Vérification facultative du dispositif de mesure . 10
11 Rapport d'essai . 11
Annexe A (informative) Exemple de sources d'incertitude de mesure. 12
Annexe B (informative) Exemple d'analyse de l'incertitude. 18
Bibliographie . 20

Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 3.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments de la présente partie de l'ISO 11904 peuvent faire
l'objet de droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 11904-1 a été élaborée par le comité technique ISO/TC 43, Acoustique.
L'ISO 11904 comprend les parties suivantes, présentées sous le titre général Acoustique — Détermination de
l'exposition sonore due à des émissions sonores placées à proximité de l'oreille:
— Partie 1: Technique du microphone placé dans une oreille réelle (technique MIRE)
— Partie 2: Technique utilisant un mannequin (technique du mannequin)
Les Annexes A et B de la présente partie de l'ISO 11904 sont données uniquement à titre d'information.
iv © ISO 2002 — Tous droits réservés

Introduction
L'ISO 11904 est une série de normes spécifiant les méthodes de détermination des émissions sonores des
sources placées à proximité de l'oreille, situations dans lesquelles le niveau de pression acoustique mesuré à
la position de la personne exposée, mais en l'absence de cette dernière, ne représente pas de manière
appropriée l'exposition sonore.
Pour pouvoir évaluer l'exposition selon des critères communément établis, l'exposition de l'oreille est mesurée
puis convertie en un niveau ramené au champ libre ou au champ diffus correspondant. Le résultat est indiqué
comme le niveau de pression acoustique continu équivalent pondéré A relatif au champ libre ou au champ
diffus, L ou L lorsque l'ISO 11904-1 est utilisée ou L ou L lorsque l'ISO 11904-2
FF,H,Aeq DF,H,Aeq FF,M,Aeq DF,M,Aeq
est utilisée.
L'ISO 11904-1 décrit les mesurages effectués au moyen de microphones miniatures ou de sondes
microphoniques inséré(e)s dans les conduits auditifs de sujets humains (microphones placés dans l'oreille
réelle, technique MIRE). L'ISO 11904-2 décrit les mesurages effectués à l'aide d'un mannequin équipé de
simulateurs d'oreille comprenant des microphones (technique du mannequin).
L'ISO 11904 peut, par exemple, s'appliquer aux essais d'appareillages et à la détermination de l'exposition au
bruit au poste de travail, où, dans le cas d'une exposition à des sources placées à proximité des oreilles, le
niveau de pression acoustique mesuré à la position de la personne exposée, mais en l'absence de cette
dernière, ne représente pas de manière appropriée l'exposition sonore. Les casques et les écouteurs utilisés
pour reproduire un son (musique) ou la parole au poste de travail ou pendant les activités de loisirs, les
cloueuses utilisées à proximité de la tête du sujet et l'exposition combinée à une source sonore proche de
l'oreille et un champ acoustique extérieur constituent autant d'exemples d'application.
Lorsque des types d'appareils spécifiques doivent être soumis à essai (par exemple baladeurs ou protecteurs
individuels contre le bruit fournis avec des postes radio) des signaux de mesure appropriés à ce type
particulier d'appareil doivent être utilisés. Les signaux de mesure de cette nature ainsi que les conditions de
fonctionnement de l'appareil ne sont pas inclus dans l'ISO 11904 mais peuvent être l'objet d'une spécification
dans d'autres normes.
Lorsque les mesurages sont effectués au poste de travail, il convient d'identifier les diverses sources de bruit
contribuant à l'émission de bruit. Les conditions de fonctionnement de la machine et de l'équipement utilisés
peuvent être l'objet d'une spécification dans d'autres normes.
Pour ces raisons, les deux parties de l'ISO 11904 tentent de parvenir au même résultat, à savoir pour une
population donnée la valeur moyenne du niveau relatif au champ libre ou au champ diffus. L'ISO 11904-1
précise la moyenne des mesures sur un certain nombre de sujets humains et l'ISO 11904-2 utilise un
mannequin, dont le but est de reproduire les effets acoustiques d'un être humain adulte moyen. Les deux
méthodes produisent toutefois des incertitudes de mesure différentes susceptibles d'influer sur le choix de la
méthode. Seule la méthode décrite dans l'ISO 11904-1 donne les résultats qui indiquent la variance d'une
population humaine. Les informations relatives aux incertitudes sont données dans les Annexes A et B.
Lorsque l'on utilise la technique MIRE pour mesurer le son émis par les écouteurs de type intra-aural ou
stéthoscopique, des problèmes pratiques de positionnement du microphone dans le conduit auditif peuvent se
poser. L'utilisation de la technique du mannequin requiert le couplage du casque ou de l'écouteur à l'oreille de
simulation (pavillon et conduit auditif) d'une manière similaire au couplage avec l'oreille humaine. Lorsque les
casques, les écouteurs ou autres objets sont en contact avec le pavillon auriculaire, toute différence
potentielle de rigidité ou de forme du pavillon artificiel par rapport au pavillon auriculaire humain a un impact
significatif sur le résultat et peut même rendre les résultats non valables.
Le Tableau 0.1 donne un aperçu des différences entre les deux parties de l'ISO 11904.
Tableau 0.1 — Aperçu des différences entre la technique MIRE et la technique du mannequin
Paramètre ISO 11904-1 ISO 11904-2
Type de méthode Technique du microphone dans l'oreille réelle Technique du mannequin
Limites de la méthode Avec les écouteurs de type intra-aural ou Un couplage approprié peut ne pas
stéthoscopique, des problèmes pratiques de toujours être obtenu si la rigidité ou la
positionnement des microphones dans le conduit forme du pavillon artificiel est
auditif peuvent se poser. différente de celle du pavillon
humain.
Dans certains cas, la personne
exposée ne peut pas être remplac
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.