ISO/DPAS 25565
(Main)Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
- Status
- Not Published
- Technical Committee
- ISO/TC 67/SC 5 - Casing, tubing and drill pipe
- Drafting Committee
- ISO/TC 67/SC 5/WG 5 - Lined casing and tubing
- Current Stage
- 5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
- Start Date
- 05-Nov-2026
- Due Date
- 05-Nov-2026
- Completion Date
- 05-Nov-2026
Buy Documents
ISO/DPAS 25565 - Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
REDLINE ISO/DPAS 25565 - Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
ISO/DPAS 25565 is an ISO document for the oil and gas industries including lower carbon energy. It specifies requirements for non-metallic composite coiled tubing with embedded cables (CCT) used in downhole environments, including how it is configured, made, tested, documented, marked, transported, stored and installed.
What does ISO/DPAS 25565 specify?
ISO/DPAS 25565 specifies requirements for CCT used in petroleum and natural gas downhole service, including vertical, directional and horizontal wells. It focuses on the pipe and the end fittings, so it is the standard to use when the product itself, its embedded cables, and its qualification and handling need to be defined.
The document is organized into clauses on scope, normative references, terms, abbreviations, configuration, materials, technical requirements, inspection and testing, documentation, marking, packaging, transportation, storage, and installation.
| Annex | What it covers |
|---|---|
| Annex A | Test method for gas permeability of polymer materials |
| Annex B | Typical wellhead suspension |
| Annex C | Test method for collapse strength |
| Annex D | Test method for axial elongation under internal pressure |
| Annex E | Cables sealing test of downhole end fitting |
| Annex F | Considerations for installation |
What are the key requirements of ISO/DPAS 25565?
ISO/DPAS 25565 defines the product structure, the service ratings that must be established, the tests used to qualify the tubing, and the information needed to buy, identify and install it. In practice, it gives the manufacturer and purchaser a common basis for design, qualification and acceptance.
Configuration and identification
ISO/DPAS 25565 covers both bonded and unbonded CCT. Both are built from a liner, reinforcement layer, tensile layer and cover, and they can embed power cables, signal cables, heating cables or optical fibres. This matters because the internal build-up and the cable package affect pressure capacity, flexibility, electrical performance and the way the tubing is handled in the field.
Clause 5 also requires an end-fitting arrangement that allows cables to be drawn out from the end fitting and connector. The designation system in Clause 5.3 ties together the pipe type, application, nominal diameter, NPR, MAOT, TLR and cable type, which helps procurement and operations teams specify exactly what is being supplied.
Materials and service suitability
Clause 6 makes the manufacturer responsible for selecting and supplying materials that suit the service and installation conditions. For the CCT body, the document points to API Spec 15S:2022 for the liner, reinforcement and cover materials. For sour service end fittings, material selection follows NACE MR0175 and/or ISO 15156-1, ISO 15156-2 and ISO 15156-3, with qualification testing by NACE TM0177 when needed.
The document also ties embedded components to external cable standards. Power, signal and heating cables follow API RP 11S5, IEC 62893-1 or an applicable industry standard, while optical fibres follow ITU-T G.652 for single-mode fibres or IEC 60793-2-10 for multimode fibres. If the liner is intended for acidic gases, Annex A can be used to evaluate gas permeability, which helps confirm whether the polymer layer is suitable for the fluid environment.
Pressure, load and dimensional ratings
Clause 7 requires the manufacturer to establish the main operating limits. The maximum pressure rating (MPR) is determined by long-term hydrostatic testing, and the nominal pressure rating (NPR) is determined by the API Spec 15S method and cannot exceed MPR. The maximum operating pressure (MOP) is derived from NPR using fluid service factors, so the same tubing may have different usable pressure limits depending on whether the service is gas, hydrocarbon liquid, water or another fluid.
The tensile load rating (TLR) must be set for the actual application, and it must cover the suspended tubing, lower-end suspension components and pump pull forces. The minimum bending radius (MBR) must also be determined and documented for storage, handling and operation. For dimensions, the document sets nominal diameter and minimum inside diameter rules and requires the manufacturer to document internal and outer diameter, plus outside-diameter and layer-thickness tolerances. That is important because field fit, reel handling and installation depend on size control as much as on strength.
Inspection, testing and acceptance
Clause 8 is the core qualification and acceptance section. Specimens are conditioned before testing, and surface quality, dimensions and length are checked on each roll. The quality assurance tests include crack resistance under radial compression, short-term burst pressure, tensile testing, collapse strength, axial elongation under internal pressure, 1 000 hour constant pressure testing, rapid decompression, short-term cyclic internal pressure, whole-coiled-length pressure testing, and the cables sealing test of the downhole end fitting.
The electrical checks are equally important because the tubing is intended to carry embedded cables. Clause 8 requires conductor resistance, insulation resistance and AC voltage testing, and it also requires electrical performance to remain acceptable after mechanical and pressure tests such as tensile loading, long-duration pressure exposure and end-fitting sealing. If the CCT includes heating cables, the heating test must raise the internal water temperature by at least 15 °C while keeping the outer surface temperature within MAOT. In practice, this verifies that the tubing still performs its downhole function after being mechanically and hydraulically stressed.
Clause 8 also defines the inspection lot, sampling plan, batch release test and type test. The lot structure and sampling method are important for production control, while the type test rules tell the manufacturer when a full requalification is needed after design, material or process changes.
What terms does ISO/DPAS 25565 define?
- Composite coiled tubing with embedded cables (CCT) - non-metallic multilayer coiled tubing with embedded power, signal, heating or fibre optic cables.
- Bonded CCT - CCT in which the non-metallic reinforcement is integrated and bonded to the liner.
- Unbonded CCT - CCT with separate unbonded polymeric and helical reinforcement layers that can move relative to each other.
- End fitting - the connecting and sealing device at the CCT end that includes the cable-crossing function.
- Maximum allowable operating temperature (MAOT) - the highest continuous working temperature that can be applied with a high degree of certainty against failure.
- Maximum operating pressure (MOP) - the maximum normal operating pressure obtained from NPR using application-related service factors.
- Maximum pressure rating (MPR) - the highest continuous internal hydrostatic pressure that can be applied with a high degree of certainty against failure.
- Tensile load rating (TLR) - the maximum continuous tensile load that can be applied with a high degree of certainty against failure.
Who uses ISO/DPAS 25565?
ISO/DPAS 25565 is used by CCT manufacturers, cable suppliers, end-fitting makers, and oil and gas operators that use downhole artificial lift, water injection and gas recovery by water drainage. It is also relevant to engineering, QA/QC, inspection and procurement teams that need to specify product ratings, verify test evidence, and agree on acceptance criteria.
The installation guidance in Annex F makes it useful for field crews and service companies that plan wellsite layout, reel handling, lifting and lowering operations, electrical checks and pressure testing. Buyers use it to compare offers on a like-for-like technical basis.
Which standards are used with ISO/DPAS 25565?
The document relies on several companion standards for materials, testing and qualification. ISO 291 sets conditioning atmospheres for test specimens, ISO 472 provides plastics vocabulary, and ISO 3126 is used for dimensional measurement.
For pressure and mechanical qualification, ISO 1167-1, ISO 13628-11, ASTM D1598 and ASTM D1599 are used. For inspection planning, ISO 2859-1 provides the sampling approach. For sour service, the document refers to ISO 15156-1, ISO 15156-2, ISO 15156-3, NACE MR0175 and NACE TM0177. For embedded cables and fibres, it uses IEC 60060-1, IEC 60228, IEC 60512-3-1, IEC 60793-2-10, IEC 60794-1-1, IEC 62893-1, API RP 11S5 and ITU-T G.652. API Spec 15S:2022 is the main companion reference for CCT pressure ratings, qualification and rapid decompression behavior.
What does the ISO/DPAS 25565 document contain?
The document includes configuration figures for bonded and unbonded CCT, an end-fitting figure, a designation figure, a sizing table, an AC voltage test table and an inspection sampling table. It also contains test methods and procedures for gas permeability, collapse strength, axial elongation and cable sealing, together with a typical wellhead suspension arrangement and installation considerations.
Those annexes support design review, product qualification, factory acceptance testing, and field installation planning. In practical terms, they give the user the setup, sequence and reporting basis for verifying mechanical integrity, hydraulic performance, cable integrity and safe handling.
Buy Documents
ISO/DPAS 25565 - Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
REDLINE ISO/DPAS 25565 - Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.
ABS Group Brazil
ABS Group certification services in Brazil.

ABS Quality Evaluations Inc.
American Bureau of Shipping quality certification.
Sponsored listings
Frequently Asked Questions
ISO/DPAS 25565 is a draft published by the International Organization for Standardization (ISO). Its full title is "Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables". This standard covers: Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
ISO/DPAS 25565 is classified under the following ICS (International Classification for Standards) categories: 75.180.10 - Exploratory, drilling and extraction equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/DPAS 25565 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 batch release test
- 3.2 bonded CCT
- 3.3 composite coiled tubing with embedded cables
- 3.4 connector
- 3.5 cover
- 3.6 crack resistance under radial compression
- 3.7 downhole end fitting
- 3.8 end fitting
- 3.9 hanger end fitting
- 3.10 heating cable
- 3.11 insulation resistance
- 3.12 insulation resistance
- 3.13 liner
- 3.14 maximum allowable operating temperature
- 3.15 maximum operating pressure
- 3.16 maximum pressure rating
- 3.17 minimum bending radius
- 3.18 nominal diameter
- 3.19 nominal pressure rating
- 3.20 power cable
- 3.21 reinforcement layer
- 3.22 short-term burst pressure
- 3.23 signal cable
- 3.24 tensile failure load
- 3.25 tensile layer
- 3.26 tensile load rating
- 3.27 tape
- 3.28 type test
- 3.29 unbonded composite coiled tubing with embedded cables
- 4 Abbreviated terms and symbols
- 4.1 Symbols
- 4.2 Abbreviated terms
- 5 CCT configuration
- 5.1 Configuration
- 5.2 End fitting
- 1 CCT
- 5.3 Designation
- 6 Materials
- 6.1 General
- 6.2 Materials of the CCT body
- 6.3 End fitting
- 6.4 Power cable, signal cable and heating cable
- 6.5 Optical fibre
- 7 Technical requirements
- 7.1 General
- 7.2 Determination of MPR and NPR
- 7.3 Determination of MOP
- 7.4 Determination of TLR
- 7.5 Determination of MBR
- 7.6 Dimensions
- 8 Inspection and testing
- 8.1 Conditioning
- 8.2 Surface quality
- 8.3 Dimensions
- 8.4 Quality assurance tests
- 8.5 Electrical performance
- 8.6 Heating performance
- 8.7 Inspection frequency and acceptance criteria
- 9 Documentation
- 9.1 Documents provided by the purchaser
- 9.2 Documents provided by the manufacturer
- 10 Marking, packaging, transportation and storage
- 10.1 Marking
- 10.2 Packaging
- 10.3 Transportation
- 10.4 Storage
- 11 Installation
- Annex A
- Annex B
- 1 BPV
- 6 CCT
- 8 CCT cables
- 9 CCT power cable lead-out
- 10 CCT heating cable lead-out
- 11 CCT signal and control cable lead-out
- Annex C
Introduction
Users of this document should be aware that further or differing requirements can be needed for individual applications. This document is not intended to inhibit a manufacturer from offering, or the purchaser from accepting, alternative equipment or engineering solutions for the individual application. This can be particularly applicable where there is innovative or developing technology. Where an alternative is offered, it is the responsibility of the manufacturer to identify and provide details of any variations from this document.
FINAL DRAFT Publicly Available Specification ISO/DPAS 25565:2026(en) Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
1 Scope
This document specifies requirements for non-metallic composite coiled tubing with embedded cables (CCT) used for downhole environments in the petroleum and natural gas industries downhole environments, including configuration, materials, technical requirements, inspection and testing, documentation, marking, packaging, transportation, storage, and installation.
This document is applicable to CCT used for downhole artificial lift, water injection and gas recovery by water drainage in vertical wells, directional wells, and horizontal wells. This document is limited to pipe and end fittings and does not relate to other system components and appurtenances. Where other system components (e.g., electric submersible pump, elbows, tees, valves) are of conventional construction, they are governed by other applicable codes and practices.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 291, Plastics — Standard atmospheres for conditioning and testing ISO 472, Plastics — Vocabulary ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method ISO 2859-1, Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions ISO 13628-11, Petroleum and natural gas industries — Design and operation of subsea production systems — Part 11: Flexible pipe systems for subsea and marine applications ISO 15156-1, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 1: General principles for selection of cracking-resistant materials ISO 15156-2, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 2: Cracking-resistant carbon and low-alloy steels, and the use of cast irons ISO 15156-3, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 3: Cracking-resistant CRAs (corrosion-resistant alloys) and other alloys IEC 60060-1, High-voltage test techniques - Part 1: General terminology and test requirements IEC 60228, Conductors of insulated cables IEC 60512-3-1, Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance
ISO/DPAS 25565:2026(en) IEC 60793-2-10, Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres IEC 62893-1, Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requirements API RP 11S5, Recommended Practice for Application of Electric Submersible Cable Systems API Spec 15S:2022, Spoolable Reinforced Plastic Line Pipe ASTM D1598, Test Method for Time-To-Failure of Plastic Pipe under Constant Internal Pressure ASTM D1599, Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings ITU-T G.652, Characteristics of a single-mode optical fibre cable NACE MR0175, Petroleum and natural gas industries-Materials for use in H2S-containing environments in oil and gas production NACE TM0177, Laboratory Testing of Metals for Resistance to Sulfide Stress Cracking and Stress Corrosion Cracking in H2S Environments
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 472 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 batch release test
test performed by or on behalf of the manufacturer on a batch of products, which must be satisfactorily completed before the batch can be released [1] [SOURCE: ISO/PAS 16846:2025 , 3.1.2]
3.2 bonded CCT
bonded composite coiled tubing with embedded cables composite coiled tubing with embedded cables (3.3) in which the non-metallic reinforcement is integrated and bonded to the liner
3.3 composite coiled tubing with embedded cables
CCT non-metallic multi-layer coiled tubing embedded with a power cable (3.20), heating cable (3.10), signal cable (3.23), or fibre optic cables, etc.
3.4 connector
device used to provide a leak-tight structural connection between the end fitting (3.8) and adjacent piping
3.5 cover
protective outer sheath of composite coiled tubing with embedded cables
ISO/DPAS 25565:2026(en)
3.6 crack resistance under radial compression
integrity of pipe structure when flattened under radial compression
3.7 downhole end fitting
end fitting (3.8) at the lower end of the composite coiled tubing with embedded cables (3.3) that connects to downhole tools or electrical submersible pump
3.8 end fitting
connecting and sealing device equipped at the composite coiled tubing with embedded cables (3.3) end with cable crossing function
3.9 hanger end fitting
end fitting at the upper end of the composite coiled tubing with embedded cables (3.3) that connects to the wellhead suspension assembly
3.10 heating cable
cable used to heat the composite coiled tubing with embedded cables
3.11 insulation resistance
resistance of insulation material between two conductors under specified conditions
3.12 insulation resistance
resistance of insulation material between two conductors under specified conditions
3.13 liner
continuous polymeric layer that is in contact with the conveyed fluid
3.14 maximum allowable operating temperature
maximum working temperature that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur
3.15 maximum operating pressure
maximum pressure permitted for normal pipeline operation which is obtained by multiplying the nominal pressure rating (3.19) by application-related service factors
3.16 maximum pressure rating
maximum internal hydrostatic pressure that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur
3.17 minimum bending radius
minimum allowable bend radius the composite coiled tubing with embedded cables is subjected to during storage, handling or operation
3.18 nominal diameter
specified inside diameter
ISO/DPAS 25565:2026(en)
3.19 nominal pressure rating
pressure rating of the pipe as defined by the manufacturer and that does not exceed the maximum pressure rating
3.20 power cable
cable used to provide power for downhole tools
3.21 reinforcement layer
structural layer that increases the resistance of composite coiled tubing with embedded cables (3.3) to internal and external pressure and mechanical damage loads
3.22 short-term burst pressure
burst pressure measured in a short-term test, where pressure is increased at a prescribed rate within a prescribed temperature range
3.23 signal cable
cable used to transmit signals from underground sensors
3.24 tensile failure load
load value corresponding to the yield point of the tensile curve of the composite coiled tubing with embedded cables (3.3)
3.25 tensile layer
structural layer which consists of helically wound non-metallic reinforcement and is used to sustain, totally or partially, tensile loads and internal pressure Note 1 to entry: Tensile layers are typically counter-wound in pairs
3.26 tensile load rating
TLR maximum tensile load that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur
3.27 tape
reinforcement type in which the strength elements are consolidated in a matrix material and provided as a flat, flexible, ribbon
3.28 type test
test performed to prove that the product is capable of conforming to the requirements given in the relevant standard Note 1 to entry: The type test results remain valid until there is a change in the product provided that the process verification tests are done regularly.
3.29 unbonded composite coiled tubing with embedded cables
unbonded CCT composite coiled tubing with embedded cables (3.3) that consists of separate unbonded polymeric and helical reinforcement layers (3.21), which allows relative movement between layers
ISO/DPAS 25565:2026(en)
4 Abbreviated terms and symbols
4.1 Symbols
F other factor f F fluid service factor sn
4.2 Abbreviated terms
AC alternating current BPV back pressure valve CCT composite coiled tubing with embedded cables DCR direct current resistance EMS environment management system ESP electric submersible pump ID inside diameter MAOT maximum allowable operating temperature MBR minimum bending radius MOP maximum operating pressure MPR maximum pressure rating NPR nominal pressure rating TLR tensile load rating
5 CCT configuration
5.1 Configuration
Both bonded and unbonded CCT are mainly composed of liner, reinforcement layer, tensile layer and cover, and embedded with power cables, signal cables, heating cables or optical fibres, etc. The two typical pipe body structures are shown in Figure 1 and Figure 2, respectively. NOTE 1 Figure 1 and Figure 2 are schematic diagrams of CCT structure, which do not represent the actual stacking sequence and stacking quantity of each layer in a final product. The type and quantity of cables can be designed according to the actual application needs.
Bonded CCT is a type of composite pipe that consists of a thermoplastic liner on which the structural layer is wound, consisting of an even number of balanced helical windings of reinforcement tape. NOTE 2 Reinforcement layer and tensile layer in Figure 1 are the reinforcement tape with thermoplastic resins but with different winding angle.
Unbonded CCT is a type of composite pipe in which the structural layer consists of an even number of balanced helical windings of continuous glass fibers in an epoxy thermoset resin matrix. NOTE 3 Reinforcement layer and tensile layer in Figure 2 are the same materials but with different winding angle.
ISO/DPAS 25565:2026(en) Key 1 liner 2 power cable 3 heating cable 4 signal cable or optical fibre 5 tensile layer 6 reinforcement layer 7 cover Figure 1 — Configuration of bonded CCT (type I) Key 1 liner 2 reinforcement layer 3 signal cable or optical fibre 4 heating cable 5 power cable 6 tensile layer 7 cover Figure 2 — Configuration of unbonded CCT (type II)
ISO/DPAS 25565:2026(en)
5.2 End fitting
Typical configuration of the end fitting is shown in Figure 3. All the cables shall be able to be drawn out from the end fitting and connector. Other assemblies of the end fitting can be acceptable if been agreed upon between the manufacturer and the purchaser.
Key
1 CCT
2 end fitting 3 connector 4 cables Figure 3 — Configuration of end fitting
5.3 Designation
The designation of CCT shall be in accordance with Figure 4 :
Figure 4 — Designation of CCT EXAMPLE A bonded type CCT embedded with signal cable for water injection with nominal diameter of 2 in., NPR of 30 MPa, MAOT of 80 °C, and TLR of 125 kN, the designation is represented as: CCT-I-WI-2in.-30 MPa -80 °C-125 kN-S.
ISO/DPAS 25565:2026(en)
6 Materials
6.1 General
The manufacturer shall be responsible for the selection and supply of all materials so that the materials meet the specified service and installation requirements.
6.2 Materials of the CCT body
Materials requirements for the liner, the reinforcing elements such as fiber, thermosetting resin, thermoplastic resin in reinforcement layer and tensile layer and the cover used in manufacturing CCT shall conform to the requirements specified in API Spec 15S:2022.
When the liner intends to be used in environments containing acidic gases (H S, CO , etc.), the gas 2 2 permeability of the liner should be evaluated in accordance with Annex A to support material selection.
6.3 End fitting
The end fitting shall sustain its integrity under the given service conditions. Fittings shall be fabricated from materials in accordance with either a written specification or an applicable industry standard. The fitting material shall sustain its function for the manufacturer-specified service conditions. Metallic material selection shall consider corrosive attack in the environment to which the fitting is exposed. Materials for fitting components for sour service applications in contact with conveyed fluids shall be selected in accordance with NACE MR0175 and/or ISO 15156-1, ISO 15156-2 and ISO 15156-3. Where qualification testing of materials is required, it shall be conducted according to the test procedure in NACE TM0177.
All end-fitting connectors and connector components shall be in accordance with a recognized industry standard, or as specified by the purchaser.
6.4 Power cable, signal cable and heating cable
When using polyimide film wrapped round copper wire as power cable, the basic performance shall conform to the requirements specified in API RP 11S5.
When fluoroplastic cables are used as power cables, signal cables, or heating cables, their basic performance shall conform to the requirements specified in IEC 62893-1.
When using other types of cables for power cable, signal cable, and heating cable, they shall conform to the requirements given in the applicable industry standard.
6.5 Optical fibre
When using single-mode optical fibres, the basic performance shall conform to the requirements specified in ITU-T G.652. When using multimode optical fibres, the basic performance shall conform to the requirements specified in IEC 60793-2-10.
When laid in the form of optical cable, the basic performance should refer to the requirements specified in [2] IEC 60794-1-1 .
7 Technical requirements
7.1 General
Manufacturers shall ensure that CCTs have structural integrity under the expected working conditions, and conform to the requirements for installation and use under the given service conditions. Typical CCT connections with the wellhead suspension device are listed in Annex B. Manufacturers and/or users should
ISO/DPAS 25565:2026(en) establish a program to verify the reliability of CCTs and their systems. For example, the manufacturer shall establish a test program to verify the fatigue performance of CCT under fixed or alternating axial load based on the type of electric submersible centrifugal pump connected to the CCT. At the same time, manufacturers and/or users shall verify whether the torsion resistance of the CCT can meet the working torque requirements of the electric submersible centrifugal pump.
7.2 Determination of MPR and NPR
The MPR of CCT shall be determined through long-term hydrostatic testing as required in API Spec 15S:2022, 5.3.2. The NPR of the CCT shall be determined referring to the requirements in API Spec 15S:2022, Annex E, and the NPR shall not exceed the MPR.
7.3 Determination of MOP
The MOP may be obtained by multiplying the NPR by application related fluid service factors (F ) as shown Sn in Formula (1):
(1) Guidelines for fluid, F are as follows:
Sn a) Use an F of 0,67 or less for all gas services; Sn b) Use an F of 0,80 or less for all hydrocarbon liquid services; Sn c) Use an F of 1,0 or less for all water services.
Sn d) Multiphase services and other fluids require individual evaluation to assess consequence of failure prior to assigning a fluid service factor.
F is the other factors, including but not limited to cyclic load, chemical aging, installation factor, selected f reliability, etc.
7.4 Determination of TLR
The TLR of CCT shall be designed by the manufacturer based on the actual application conditions, for example based on different well depth. The TLR shall not be less than the total weight of the CCT below the wellhead and the suspension components at the lower end of the pipe, as well as the axial pulling force of the pump.
7.5 Determination of MBR
The manufacturer shall determine and document the storage, handling and operating MBR of CCT as described in API Spec 15S.
7.6 Dimensions
The nominal diameter for sizes 76,2 mm (3 in.) and greater shall be in 12,7 mm (0,5 in.) increments and the minimum allowable ID shall not be less than the nominal diameter minus 12,7 mm (0,5 in.); For nominal diameter smaller than 76,2 mm (3 in.), the minimum allowable ID shall not be less than the nominal diameter minus 6,35 mm (0,25 in.); see the example in Table 1. The manufacturer shall document both the internal and outer diameter of the CCT.
Other sizes and dimensions of CCTs shall be agreed upon between the manufacturer and the purchaser. The manufacturer shall specify and document the tolerances to be used for the outside diameter of the pipe and for the thickness of each layer of the pipe. These tolerances shall be verified in the design process to be acceptable such that the performance of the individual layers and pipe are unaffected by variations within the specified tolerances.
ISO/DPAS 25565:2026(en) Table 1 — Sizing in accordance with nominal diameter Nominal Diameter Minimum ID mm (in.) mm (in.) 38,1 (1,5) 31,75 (1,25) 50,8 (2,0) 44,45 (1,75) 63,5 (2,5) 57,15 (2,25) 76,2 (3,0) 63,5 (2,5) 88,9 (3,5) 76,2 (3,0) 101,6 (4,0) 88,9 (3,5)
8 Inspection and testing
8.1 Conditioning
Unless otherwise specified, CCT test specimens shall be taken at least 24 h after the production, and the test specimens shall be conditioned at a temperature of (23 ± 2) °C for at least 24 h before testing in accordance with the requirements specified in ISO 291.
8.2 Surface quality
The appearance quality shall be visually inspected. The colour of the CCT shall be uniform and consistent, and the inner and outer surfaces shall be clean and smooth, without bubbles, obvious scratches, dents or impurities.
The outer surface of the CCT shall have clear and visible markings, and the designation identification shall meet the requirements in 5.3.
8.3 Dimensions
8.3.1 Length
Measure the length using a measuring tool (instrument) with a graduation value no greater than 1 mm. The length of the CCT to be supplied is determined through negotiation between the manufacturer and the purchaser. The length error of the supplied CCT should not exceed ±0.5 % of the value agreed upon by both parties. The outer surface of the CCT shall have markings indicating the continuous length, and the spacing between the marks shall not be greater than 5 m.
8.3.2 Outer diameter
The outer diameter shall be measured according to the method specified in ISO 3126. The outer diameter of CCT shall conform to the document provided by manufacturer.
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, symbols and abbreviations
- 43 Terms and definitions
- 4.23.2 bonded CCT
- 4.43.4 connector
- 4.53.5 cover
- 4.63.6 crack resistance under radial compression
- 4.73.7 downhole end fitting
- 4.83.8 end fitting
- 4.93.9 hanger end fitting
- 3.11 insulation resistance
- 3.29 unbonded composite coiled tubing with embedded cables
- 4 Abbreviated terms and symbols
- 4.29 Abbreviations
- 4.2 Abbreviated terms
- 5 CCT configuration
- 5.1 Configuration
- 5.2 End fitting
- 1 CCT
- 5.3 Designation
- 6 Materials
- 6.1 General
- 6.2 Materials of the CCT body
- 6.3 End fitting
- 6.4 Power cable, signal cable and heating cable
- 6.5 Optical fibre
- 7 Technical requirements
- 7.1 General
- 7.2 Determination of MPR and NPR
- 7.3 Determination of MOP
- 7.4 Determination of TLR
- 7.5 Determination of MBR
- 7.6 Dimensions
- 8 Inspection and testing
- 8.1 Conditioning
- 8.2 Surface quality
- 8.3 Dimensions
- 8.4 Quality assurance tests
- 8.5 Electrical performance
- 8.6 Heating performance
- 8.7 Inspection frequency and acceptance criteria
- 9 Documentation
- 9.1 Documents provided by the purchaser
- 9.2 Documents provided by the manufacturer
- 10 Marking, packaging, transportation and storage
- 10.1 Marking
- 10.2 Packaging
- 10.3 Transportation
- 10.4 Storage
- 11 Installation
- Annex A
- Annex B
- 1 BPV
- 6 CCT
- 8 CCT cables
- 9 CCT power cable lead-out
- 10 CCT heating cable lead-out
- 11 CCT signal and control cable lead-out
- Annex C
- Annex D
- 3 V-groove test platform
- Annex E
- Annex F
- 1 Vehicle driving Drive tired other General and management
- 2 Falling objects Porters Minor
- 4 Minor
- 5 Electric shock Electricians Minor
- 8 Workers Minor
- 10 Falling objects General conduct regular
- 13 Fall off Minor
- 15 Topple and fall Minor
- 18 Equipment Minor
- 19 Fall off Workers Minor
- 20 Tool polishing Bruise Workers Minor and wear protective
- 21 Repair vehicle Injury Drivers Minor operation
- 22 Night driving General
- 23 Ice-snow road other General regulations, early
- Bibliography
Introduction
Users of this document should be aware that further or differing requirements can be needed for individual applications. This document is not intended to inhibit a manufacturer from offering, or the purchaser from accepting, alternative equipment or engineering solutions for the individual application. This can be particularly applicable where there is innovative or developing technology. Where an alternative is offered, it is the responsibility of the manufacturer to identify and provide details of any variations from this document. In this document, the following verbal forms are used:
- “shall” indicates a requirement;
- “should” indicates a recommendation;
- “can” indicates a possibility or a capability;
- “may” indicates a permission.
ISO/DPAS 25565:2026(en) Oil and gas industries including lower carbon energy — Composite coiled tubing with embedded cables
1 Scope
This document specifies requirements for non-metallic composite coiled tubing with embedded cables (CCT) used for downhole environments in the petroleum and natural gas industries downhole environments, including configuration, materials, technical requirements, inspection and testing, documentation, marking, packaging, transportation, storage, and installation.
This document is applicable to CCT used for downhole artificial lift, water injection and gas recovery by water drainage in vertical wells, directional wells, and horizontal wells. This document is limited to pipe and end fittings and does not relate to other system components and appurtenances. Where other system components (e.g., electric submersible pump, elbows, tees, valves) are of conventional construction, they will beare governed by other applicable codes and practices.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 291, Plastics — Standard atmospheres for conditioning and testing ISO 472, Plastics — Vocabulary ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method ISO 2859-1, Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions ISO 13628-11, Petroleum and natural gas industries — Design and operation of subsea production systems — Part 11: Flexible pipe systems for subsea and marine applications ISO 15156-1, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 1: General principles for selection of cracking-resistant materials ISO 15156-2, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 2: Cracking-resistant carbon and low-alloy steels, and the use of cast irons ISO 15156-3, Petroleum and natural gas industries — Materials for use in H2S-containing environments in oil and gas production — Part 3: Cracking-resistant CRAs (corrosion-resistant alloys) and other alloys IEC 60060-1, High-voltage test techniques - Part 1: General terminology and test requirements IEC 60228, Conductors of insulated cables IEC 60512-3-1, Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance
ISO/DPAS 25565:2026(en) IEC 60793-2-10, Optical fibres - Part 2-10: Product specifications - Sectional specification for category A1 multimode fibres IEC 60794-1-1, Optical fibre cables - Part 1-1: Generic specification - General IEC 62893-1, Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requirements API RP 11S5, Recommended Practice for Application of Electric Submersible Cable Systems API Spec 15S:2022, Spoolable Reinforced Plastic Line Pipe ASTM D1598, Test Method for Time-To-Failure of Plastic Pipe under Constant Internal Pressure ASTM D1599, Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings ITU-T G.652, Characteristics of a single-mode optical fibre cable NACE MR0175, Petroleum and natural gas industries-Materials for use in H2S-containing environments in oil and gas production NACE TM0177, Laboratory Testing of Metals for Resistance to Sulfide Stress Cracking and Stress Corrosion Cracking in H2S Environments
3 Terms, definitions, symbols and abbreviations
43 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 472 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- — ISO Online browsing platform: available at https://www.iso.org/obp
- — IEC Electropedia: available at https://www.electropedia.org/ 4.13.1 https://www.electropedia.org/ batch release test test performed by or on behalf of the manufacturer on a batch of products, which must be satisfactorily completed before the batch can be released [1] [SOURCE: ISO/PAS 16846:2025 , 3.1.2]
4.23.2 bonded CCT
bonded composite coiled tubing with embedded cables composite coiled tubing with embedded cables (3.3CCT (3.1.3)) in which the non-metallic reinforcement is integrated and bonded to the liner 4.33.3 (3.1.12) composite coiled tubing with embedded cables CCT non-metallic multi-layer coiled tubing embedded with a power cable (3.20(3.1.19),), heating cable (3.10(3.1.10),), signal cable (3.23(3.1.22),), or fibre optic cables, etc.
ISO/DPAS 25565:2026(en)
4.43.4 connector
device used to provide a leak-tight structural connection between the end fitting (3.8( 3.1.8)) and adjacent piping
4.53.5 cover
protective outer sheath of CCT (3.1.3)composite coiled tubing with embedded cables
4.63.6 crack resistance under radial compression
integrity of pipe structure when flattened under radial compression
4.73.7 downhole end fitting
the end fitting (3.8(3.1.8)) at the lower end of the composite coiled tubing with embedded cables (3.3CCT) that connects to downhole tools or electrical submersible pump
4.83.8 end fitting
connecting and sealing device equipped at the composite coiled tubing with embedded cables (3.3CCT (3.1.3)) end with cable crossing function
4.93.9 hanger end fitting
the end fitting (3.1.8) at the upper end of the composite coiled tubing with embedded cables (3.3CCT) that connects to the wellhead suspension assembly 4.103.10 heating cable cable used to heat the CCT (3.1.3)composite coiled tubing with embedded cables
3.11 insulation resistance
resistance of insulation material between two conductors under specified conditions 4.113.12 insulation resistance resistance of insulation material between two conductors under specified conditions 4.123.13 liner continuous polymeric layer that is in contact with the conveyed fluid 4.133.14 maximum allowable operating temperature MAOT maximum working temperature that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur 4.143.15 maximum operating pressure MOP
ISO/DPAS 25565:2026(en) the maximum pressure permitted for normal pipeline operation which is obtained by multiplying the nominal pressure rating (3.19NPR (3.1.18)) by application-related service factors 4.153.16 maximum pressure rating MPR maximum internal hydrostatic pressure that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur 4.163.17 minimum bending radius MBR minimum allowable bend radius the CCT (3.1.3)composite coiled tubing with embedded cables is subjected to during storage, handling or operation 4.173.18 nominal diameter specified inside diameter 4.183.19 nominal pressure rating NPR pressure rating of the pipe as defined by the manufacturer and that does not exceed the MPR (3.1.15)maximum pressure rating 4.193.20 power cable cable used to provide power for downhole tools 4.203.21 reinforcement layer structural layer that increases the resistance of composite coiled tubing with embedded cables (3.3CCT (3.1.3)) to internal and external pressure and mechanical damage loads 4.213.22 short-term burst pressure burst pressure measured in a short-term test, where pressure is increased at a prescribed rate within a prescribed temperature range 4.223.23 signal cable cable used to transmit signals from underground sensors 4.233.24 tensile failure load load value corresponding to the yield point of the tensile curve of the composite coiled tubing with embedded cables (3.3CCT (3.1.3)) 4.243.25 tensile layer structural layer which consists of helically wound non-metallic reinforcement and is used to sustain, totally or partially, tensile loads and internal pressure
ISO/DPAS 25565:2026(en) Note 1 to entry: Tensile layers are typically counter-wound in pairs 4.253.26 .
tensile load rating TLR maximum tensile load that can be applied continuously to a pipe with a high degree of certainty that failure of the component will not occur 4.263.27 tape reinforcement type in which the strength elements are consolidated in a matrix material and provided as a flat, flexible, ribbon 4.273.28 type test test performed to prove that the product is capable of conforming to the requirements given in the relevant standard Note 1 to entry: The type test results remain valid until there is a change in the product provided that the process verification tests are done regularly.
3.29 unbonded composite coiled tubing with embedded cables
unbonded CCT composite coiled tubing with embedded cables (3.3CCT (3.1.3)) that consists of separate unbonded polymeric and helical reinforcement layers (3.21(3.1.20),), which allows relative movement between layers
4 Abbreviated terms and symbols
4.284.1 Symbols F other factor f F fluid service factor sn F other factor f F fluid service factor sn
4.29 Abbreviations
4.2 Abbreviated terms
AC alternating current BPV back pressure valve CCT composite coiled tubing with embedded cables DCR direct current resistance EMS environment management system ESP electric submersible pump
ISO/DPAS 25565:2026(en) ID inside diameter MAOT maximum allowable operating temperature MBR minimum bending radius MOP maximum operating pressure MPR maximum pressure rating NPR nominal pressure rating TLR tensile load rating
5 CCT configuration
5.1 Configuration
Both bonded and unbonded CCT are mainly composed of liner, reinforcement layer, tensile layer and cover, and embedded with power cables, signal cables, heating cables or optical fibres, etc. The two typical pipe body structures are shown in Figure 1 and Figure 2, respectively.
NOTE 1 Figure 1Figures 1 and Figure 2Figure 2 are schematic diagrams of CCT structure, which do not represent the actual stacking sequence and stacking quantity of each layer in a final product. The type and quantity of cables can be designed according to the actual application needs.
Bonded CCT is a type of composite pipe that consists of a thermoplastic liner on which the structural layer is wound, consisting of an even number of balanced helical windings of reinforcement tape. NOTE 2 Reinforcement layer and tensile layer in Figure 1Figure 1 are the reinforcement tape with thermoplastic resins but with different winding angle.
Unbonded CCT is a type of composite pipe in which the structural layer consists of an even number of balanced helical windings of continuous glass fibers in an epoxy thermoset resin matrix. NOTE 3 Reinforcement layer and tensile layer in Figure 2Figure 2 are the same materials but with different winding angle.
ISO/DPAS 25565:2026(en)
ISO/DPAS 25565:2026(en)
Key 1 liner 2 power cable 3 heating cable 4 signal cable or optical fibre 5 tensile layer 6 reinforcement layer 7 cover Figure 1 — Configuration of bonded CCT (type I)
ISO/DPAS 25565:2026(en)
ISO/DPAS 25565:2026(en)
Key 1 liner 2 reinforcement layer 3 signal cable or optical fibre 4 heating cable 5 power cable 6 tensile layer 7 cover Figure 2 — Configuration of unbonded CCT (type II)
5.2 End fitting
Typical configuration of the end fitting is shown in Figure 3Figure 3.. All the cables shall be able to be drawn out from the end fitting and connector. Other assemblies of the end fitting can be acceptable if been agreed upon between the manufacturer and the purchaser.
ISO/DPAS 25565:2026(en)
Key
1 CCT
2 end fitting 3 connector 4 cables Figure 3 — Configuration of end fitting
5.3 Designation
The designation of CCT shall be as followsin accordance with Figure 4 :
ISO/DPAS 25565:2026(en)
Figure 4 — Designation of CCT EXAMPLE A bonded type CCT embedded with signal cable for water injection with nominal diameter of 2 in., NPR of 30 MPa, MAOT of 80 °C, and TLR of 125 kN, the designation is represented as: CCT-I-WI-2in.-30 MPa -80 °C-125 kN-S.
6 Materials
6.1 General
The manufacturer shall be responsible for the selection and supply of all materials so that the materials meet the specified service and installation requirements.
6.2 Materials of the CCT body
Materials requirements for the liner, the reinforcing elements such as fiber, thermosetting resin, thermoplastic resin in reinforcement layer and tensile layer and the cover used in manufacturing CCT shall be conform to the requirements specified in API Spec 15S:2022.
ISO/DPAS 25565:2026(en) When the liner intends to be used in environments containing acidic gases (H S, CO , etc.), the gas permeability 2 2 of the liner should be evaluated in accordance with Annex AAnnex A to support material selection.
6.3 End fitting
The end fitting shall sustain its integrity under the given service conditions. Fittings shall be fabricated from materials in accordance with either a written specification or an applicable industry standard. The fitting material shall sustain its function for the manufacturer-specified service conditions. Metallic material selection shall consider corrosive attack in the environment to which the fitting is exposed. Materials for fitting components for sour service applications in contact with conveyed fluids shall be selected in accordance with NACE MR0175andMR0175 and/or ISO 15156-1, ISO 15156-2 and ISO 15156-3. Where qualification testing of materials is required, it shall be conducted according to the test procedure in NACE TM0177.
All end-fitting connectors and connector components shall be in accordance with a recognized industry standard, or as specified by the purchaser.
6.4 Power cable, signal cable and heating cable
When using polyimide film wrapped round copper wire as power cable, the basic performance shall conform to the requirements specified in API RP 11S5.
When fluoroplastic cables are used as power cables, signal cables, or heating cables, their basic performance shall conform to the requirements specified in IEC 62893-1.
When using other types of cables for power cable, signal cable, and heating cable, they shall conform to the requirements given in the applicable industry standard.
6.5 Optical fibre
When using single-mode optical fibres, the basic performance shall conform to the requirements specified in ITU-T G.652. When using multimode optical fibres, the basic performance shall conform to the requirements specified in IEC 60793-2-10.
When laid in the form of optical cable, the basic performance should refer to the requirements specified in IEC [2] 60794-1-1 IEC 60794-1-1..
7 Technical requirements
7.1 General
Manufacturers shall ensure that CCTs have structural integrity under the expected working conditions, and conform to the requirements for installation and use under the given service conditions. Typical CCT connections with the wellhead suspension device are listed in Annex BAnnex B.. Manufacturers and/or users should establish a program to verify the reliability of CCTs and their systems. For example, the manufacturer shall establish a test program to verify the fatigue performance of CCT under fixed or alternating axial load based on the type of electric submersible centrifugal pump connected to the CCT. At the same time, manufacturers and/or users shall verify whether the torsion resistance of the CCT can meet the working torque requirements of the electric submersible centrifugal pump.
ISO/DPAS 25565:2026(en)
7.2 Determination of MPR and NPR
The MPR of CCT shall be determined through long-term hydrostatic testing as required in API Spec 15S:2022, 5.3.2. The NPR of the CCT shall be determined referring to the requirements in API Spec 15S:2022, Annex E, and the NPR shall not exceed the MPR.
7.3 Determination of MOP
The MOP may be obtained by multiplying the NPR by application related fluid service factors (F ) as shown Sn in Formula (1)(1)::
𝑀𝑀𝑀𝑀𝑀𝑀 =𝑁𝑁𝑀𝑀𝑁𝑁 ×𝐹𝐹 ×𝐹𝐹 (1) 𝑆𝑆𝑆𝑆 𝑓𝑓 Guidelines for fluid, F are as follows:
Sn a) a) Use an FSn of 0,67 or less for all gas services; b) b) Use an F of 0,80 or less for all hydrocarbon liquid services; Sn c) c) Use an F of 1,0 or less for all water services.
Sn d) d) Multiphase services and other fluids require individual evaluation to assess consequence of failure prior to assigning a fluid service factor.
F is the other factors, including but not limited to cyclic load, chemical aging, installation factor, selected f reliability, etc.
7.4 Determination of TLR
The TLR of CCT shall be designed by the manufacturer based on the actual application conditions, for example based on different well depth. The TLR shall not be less than the total weight of the CCT below the wellhead and the suspension components at the lower end of the pipe, as well as the axial pulling force of the pump.
7.5 Determination of MBR
The manufacturer shall determine and document the storage, handling and operating MBR of CCT as described in API Spec 15S.
7.6 Dimensions
The nominal diameter for sizes 76,2 mm (3 in..) and greater shall be in half-inch12,7 mm (0,5 in.) increments and the minimum allowable ID shall not be less than the nominal diameter minus 1/212,7 mm (0,5 in.;.); For nominal diameter smaller than 76,2 mm (3 in.,.), the minimum allowable ID shall not be less than the nominal diameter minus 1/46,35 mm (0,25 in.;.); see the example in Table 1Table 1.. The manufacturer shall document both the internal and outer diameter of the CCT.
Other sizes and dimensions of CCTs shall be agreed upon between the manufacturer and the purchaser. The manufacturer shall specify and document the tolerances to be used for the outside diameter of the pipe and for the thickness of each layer of the pipe. These tolerances shall be verified in the design process to be acceptable such that the performance of the individual layers and pipe are unaffected by variations within the specified tolerances.
ISO/DPAS 25565:2026(en) Table 1 — Sizing in accordance with nominal diameter Nominal Diameter Minimum ID mm (in.) mm (in.) 38,1 (1,5) 31,75 (1,25) 50,8 (2,0) 44,45 (1,75) 63,5 (2,5) 57,15 (2,25) 76,2 (3,0) 63,5 (2,5) 88,9 (3,5) 76,2 (3,0) 101,6 (4,0) 88,9 (3,5)
8 Inspection and testing
8.1 Conditioning
Unless otherwise specified, CCT test specimens shall be taken at least 24 h after the production, and the test specimens shall be conditioned at a temperature of (23± ± 2) °C for at least 24 h before testing in accordance with the requirements specified in ISO 291.
8.2 Surface quality
The appearance quality shall be visually inspected. The colour of the CCT shall be uniform and consistent, and the inner and outer surfaces shall be clean and smooth, without bubbles, obvious scratches, dents or impurities.
...