DRAFT INTERNATIONAL STANDARD
ISO/DIS 15192
ISO/TC 190/SC 3 Secretariat: DIN
Voting begins on: Voting terminates on:
2020-04-17 2020-07-10
Characterization of soil and waste — Determination of
Chromium(VI) in solid material by alkaline digestion and
ion chromatography with spectrophotometric detection
ICS: 13.080.10
THIS DOCUMENT IS A DRAFT CIRCULATED
This document is circulated as received from the committee secretariat.
FOR COMMENT AND APPROVAL. IT IS
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
ISO/CEN PARALLEL PROCESSING
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 15192:2020(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION. ISO 2020
---------------------- Page: 1 ----------------------
ISO/DIS 15192:2020(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2020
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2020 – All rights reserved
---------------------- Page: 2 ----------------------
ISO/DIS 15192:2020(E)
Contents Page
Foreword ........................................................................................................................................................................................................................................iv
Introduction ..................................................................................................................................................................................................................................v
1 Scope ................................................................................................................................................................................................................................. 1
2 Normative references ...................................................................................................................................................................................... 1
3 Terms and definitions ..................................................................................................................................................................................... 1
4 Safety remarks ........................................................................................................................................................................................................ 2
5 Principle ........................................................................................................................................................................................................................ 2
5.1 Digestion....................................................................................................................................................................................................... 2
5.2 Determination ......................................................................................................................................................................................... 2
5.3 Interferences and sources of error ........................................................................................................................................ 2
6 Apparatus ..................................................................................................................................................................................................................... 3
6.1 Digestion equipment .......................................................................................................................................................................... 3
6.2 Filtration equipment .......................................................................................................................................................................... 3
6.3 Membrane filters ................................................................................................................................................................................... 3
6.4 Ion chromatographic system ...................................................................................................................................................... 3
6.5 Ion chromatographic column ..................................................................................................................................................... 3
6.6 Detection system ................................................................................................................................................................................... 3
7 Reagents ........................................................................................................................................................................................................................ 3
8 Sample pretreatment ....................................................................................................................................................................................... 5
9 Alkaline digestion procedure .................................................................................................................................................................. 6
10 Analytical procedure ........................................................................................................................................................................................ 6
10.1 General information ........................................................................................................................................................................... 6
10.2 Instrumental set-up ............................................................................................................................................................................ 7
10.3 Calibration .................................................................................................................................................................................................. 7
10.4 Test solution measurement .......................................................................................................................................................... 7
10.5 Quality Control ........................................................................................................................................................................................ 7
10.5.1 General...................................................................................................................................................................................... 7
10.5.2 Blank test solution .......................................................................................................................................................... 8
10.5.3 Verification of method ........................................................................................................................................... ...... 8
10.5.4 Duplicate samples ........................................................................................................................................................... 8
10.5.5 Cr(VI) spiked samples ................................................................................................................................................. 8
10.5.6 Cr(III) spiked samples ................................................................................................................................................. 8
10.5.7 Interpretation of quality control data............................................................................................................ 9
11 Calculation .................................................................................................................................................................................................................. 9
12 Expression of results ........................................................................................................................................................................................ 9
13 Test report ................................................................................................................................................................................................................... 9
Annex A (informative) Alternative methods for direct determination of Cr(VI) in the
alkaline digestion solution .....................................................................................................................................................................11
Annex B (informative) Ion chromatographic system........................................................................................................................12
Annex C (informative) Requirements for test portion preparation ..................................................................................13
Annex D (informative) Validation .........................................................................................................................................................................14
Bibliography .............................................................................................................................................................................................................................18
© ISO 2020 – All rights reserved iii---------------------- Page: 3 ----------------------
ISO/DIS 15192:2020(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.This document was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3,
Chemical and physical characterization.This second edition cancels and replaces the first edition (ISO 15192:2010), which has been technically
revised.The main changes compared to the previous edition are as follows:
— The text has been editorially revised, including updating of references;
— Annex D has been deleted.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.iv © ISO 2020 – All rights reserved
---------------------- Page: 4 ----------------------
ISO/DIS 15192:2020(E)
Introduction
Under environmental conditions chromium in compounds exists in the trivalent, Cr(III), or the
hexavalent, Cr(VI) state. Cr(III) is an essential trace element for mammals, including man, whereas it is
presumed that Cr(VI) compounds are genotoxic and potentially carcinogenic in humans. Interconversion
of trivalent and hexavalent chromium species can occur during sample preparation and analysis, but
these processes are minimised, to the extent possible, by the sample preparation methods prescribed
by this standard.© ISO 2020 – All rights reserved v
---------------------- Page: 5 ----------------------
DRAFT INTERNATIONAL STANDARD ISO/DIS 15192:2020(E)
Characterization of soil and waste — Determination of
Chromium(VI) in solid material by alkaline digestion and
ion chromatography with spectrophotometric detection
1 Scope
This document describes the determination of Cr(VI) in solid waste material and soil by alkaline
digestion and ion chromatography with spectrophotometric detection. This method can be used to
determine Cr(VI)-mass fractions in solids higher than 0,1 mg/kg.NOTE In case of reducing or oxidising waste matrix no valid Cr(VI) content can be reported.
2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 3696, Water for analytical laboratory use — Specification and test methodsISO 11464, Soil quality — Pretreatment of samples for physico-chemical analysis
ISO 11465, Soil quality — Determination of dry matter and water content on a mass basis —
Gravimetric methodISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
EN 15002, Characterization of waste — Preparation of test portions from the laboratory sample
EN 15934, Sludge, treated biowaste, soil and waste — Calculation of dry matter fraction after determination
of dry residue or water content3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http:// www .electropedia .org/— ISO Online browsing platform: available at http:// www .iso .org/ obp
3.1
alkaline digestion
process of obtaining a solution containing the analyte of interest from a sample under alkaline
conditions. Alkaline digestion may or may not involve complete dissolution of the sample
3.2speciation analysis
activities of measuring the quantity of one or more individual chemical species in a sample, e. g. Cr(VI)
in a particular sample or matrix© ISO 2020 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO/DIS 15192:2020(E)
4 Safety remarks
Anyone dealing with waste and soil analysis has to be aware of the typical risks of the material
irrespective of the parameters determined. Waste and soil samples may contain hazardous (e. g. toxic,
reactive, flammable, infectious) substances, which can be liable to biological and/or chemical reaction.
Consequently, it is recommended that these samples should be handled with special care. The gases
which may be produced by microbiological or chemical activity are potentially flammable and can
pressurise sealed bottles. Bursting bottles are likely to result in hazardous shrapnel, dust and/or aerosol.
National regulations should be followed with respect to all hazards associated with this method.
Avoid any contact with the skin, ingestion or inhalation of Cr(VI) compounds. Cr(VI) compounds are
genotoxic and potentially carcinogenic to humans.5 Principle
5.1 Digestion
This document describes an alkaline digestion procedure for extracting Cr(VI) from soluble, adsorbed
and precipitated forms of chromium compounds in solid waste materials and soil. To quantify the
content of Cr(VI) in a solid matrix, three criteria shall be satisfied:1) digestion solution shall solubilize all species of Cr(VI);
2) conditions of the digestion shall not induce reduction of native Cr(VI) to Cr(III);
3) method shall not cause oxidation of native Cr(III) contained in the sample to Cr(VI).
The alkaline digestion described in this document meets these criteria for a wide spectrum of solid
matrices. Under the alkaline conditions of the digestion, neglectable reduction of Cr(VI) or oxidation of
native Cr(III) is expected. The additon of Mg in a phosphate buffer to the alkaline solution prevents
air oxidation of trivalent chromium [1], [5], [8].NOTE Background on methods for the determination of Cr(VI) in solid samples is given in [3], [4], [5].
5.2 DeterminationQuantification of Cr(VI) in the alkaline digestion solution should be performed using a suitable
technique with appropriate accuracy. For this purpose ion chromatography is used to separate
Cr(VI) from interferences. Following this ion chromatographic separation, Cr(VI) is measured
spectrophotometrically either at 365 nm (direct UV detection) or after post-column derivatisation
with 1,5-diphenylcarbazide in acid solution at 540 nm. Post-column derivatisation involves reaction
of 1,5-diphenylcarbazide with Cr(VI) to produce trivalent chromium and diphenylcarbazone. These
then combine to form a trivalent chromium-diphenylcarbazone complex containing the characteristic
magenta chromagen (λ = 540 nm).max
NOTE The choice of detection method is based upon the required sensitivity. Direct UV detection is less
sensitive than detection after post-column derivatisation with 1,5-diphenylcarbazide.
Hyphenated methods with ion chromatographic separation and detection techniques, such as
inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic
emission spectroscopy (ICP-AES), may be used once validation of the chosen analytical method has
been performed.5.3 Interferences and sources of error
— Use of ion chromatography is necessary for the separation of Cr(VI) from possible interferences in
the alkaline digestion solution from solid material [6].2 © ISO 2020 – All rights reserved
---------------------- Page: 7 ----------------------
ISO/DIS 15192:2020(E)
— For waste materials or soils, where the Cr(III)/Cr(VI) ratio is expected to be high, Cr(VI) results
may be biased due to method induced oxidation. This can be particularly expected in soils high in
Mn content and amended with soluble Cr(III) salts or freshly precipitated Cr(OH) [3].
— Cr(VI) can be reduced to Cr(III) during digestion from the sample due to reaction with reducing
agents such as e.g. divalent iron. This problem is minimised in the described procedure using
alkaline digestion solution [5].— Cr(III) can be oxidised to Cr(VI) in hot alkaline solutions. This problem is minimised in the described
procedure by adding magnesium to the alkaline digestion solution [2], [3], [5], [8].
— Overloading the analytical column capacity with high concentrations of anionic species (e. g.
chloride) may cause underestimation of Cr(VI) [9].6 Apparatus
6.1 Digestion equipment
— hotplate with a magnetic stirrer, thermostatically controlled with a digestion vessel of 250 ml
covered with a watch glass; or— heating block with a magnetic stirrer, thermostatically controlled with a digestion vessel of 250 ml
covered with a watch glassNOTE Other thermostatically controlled digestion equipment with a magnetic stirrer can be used once
validation has been performed.6.2 Filtration equipment
suitable for using 0,45-µm membrane filters.
6.3 Membrane filters
0,45-µm pore size, chemically inert.
6.4 Ion chromatographic system
All components which come into contact with the sample or eluent stream shall be comprised of inert
materials, e. g. polyetherether ketone (PEEK), as shall all connecting tubing (see Annex B).
6.5 Ion chromatographic columnsuitable for chromate separation with a sufficient ion exchange capacity.
6.6 Detection system
— UV-VIS spectrophotometer at 365 nm; or
— VIS spectrophotometer at 540 nm after post column derivatisation.
7 Reagents
During the analysis, only use reagents of recognised analytical grade, and water as specified in 7.1.
© ISO 2020 – All rights reserved 3---------------------- Page: 8 ----------------------
ISO/DIS 15192:2020(E)
7.1 Water
Water complying with the requirements for ISO 3696 grade 2 water (electrical conductivity less than
0,1 mS m equivalent to resistivity greater than 0,01 MΩ m at 25 °C). It is recommended that the water
used is obtained from a purification system that delivers ultrapure water having a resistivity greater
than 0,18 MΩ m (usually expressed by manufacturers of water purification systems as 18 MΩ cm).
7.2 Sulphuric acid (H SO ),2 4
concentrated, ρ(H SO ) ~ 1,84 g/ml, w(H SO ) ~ 98 %
2 4 2 4
7.3 Sodium carbonate (Na CO ),
2 3
anhydrous, w(Na CO ) > 99,9 %
2 3
7.4 1,5-Diphenylcarbazide ((C H .NH.NH) CO),
6 5 2
w((C H .NH.NH) CO) > 98 %
6 5 2
7.5 Propanone (acetone) (C H O)
3 6
7.6 Methanol (CH O)
7.7 Potassium dichromate (K Cr O ), w(K Cr O ) > 99,9 %
2 2 7 2 2 7
Dry to constant weight at 110 °C, cool and store in a dessiccator.
7.8 Sodium hydroxide (NaOH), w(NaOH) > 99 %
7.9 Magnesium chloride hexahydrate (MgCl .6H O), w(MgCl .6H O) > 99 %
2 2 2 2
7.10 Dipotassium hydrogenphosphate (K HPO ), w(K HPO ) > 99 %
2 4 2 4
7.11 Potassium dihydrogenphosphate (KH PO ), w(KH PO ) > 99 %
2 4 2 4
7.12 Lead chromate (PbCrO ), w(PbCrO ) > 99 %
4 4
7.13 Diphenylcarbazide reagent solution
Dissolve 0,125 g of 1,5-diphenylcarbazide (7.4) in 25 ml of propanone (7.5) or methanol (7.6) in a
250 ml volumetric flask. Fill 125 ml of water into a separate container, slowly add 7 ml of concentrated
sulphuric acid (7.2), swirl to mix and allow to cool. Degass with e. g. helium or argon for 5 min to 10 min
prior to adding to the 1,5-diphenylcarbazide solution. After combining the solutions, fill up to the mark
with water and degass additionally for 5 min to 10 min. The reagent solution is stable for 5 days.
7.14 Eluent solutionUse an eluent solution appropriate to separate chromate over the ion chromatographic column (6.5).
7.15 Alkaline digestion solution, 0,5 mol/l sodium hydroxide (NaOH) / 0,28 mol/l sodium carbonate
(Na CO )2 3
Dissolve 20,0 g of sodium hydroxide (7.8) in approximately 500 ml of water (7.1). Add 30,0 g of sodium
carbonate (7.3) and swirl to mix. Quantitatively transfer the solution into a 1 l volumetric flask. Dilute
to the mark with water. The pH of the digestion solution must be checked before use. The pH shall be
11,5 or higher. Store in a polyethylene bottle at room temperature and prepare fresh monthly.
4 © ISO 2020 – All rights reserved---------------------- Page: 9 ----------------------
ISO/DIS 15192:2020(E)
7.16 Calibration solutions of Cr(VI)
7.16.1 Cr(VI) standard stock solution, 1 000 mg/l Cr(VI)
Dissolve 0,282 9 g of potassium dichromate (7.7) in 75 ml of water (7.1) in a 100 ml volumetric flask.
Dilute to the mark with water (7.1), close and mix thoroughly. Store the solution in a polypropylene
bottle for a maximum period of 1 year.Alternatively a commercial standard solution with a certified Cr(VI) concentration traceable to national
standards can be used. Observe the manufacturer's expiration date or recommended shelf life.
7.16.2 Cr(VI) working standard solution, 10 mg/l Cr(VI)Accurately pipette 10,0 ml of the Cr(VI) standard stock solution (7.16.1) into a 1 l volumetric flask,
dilute to the mark with water (7.1), close and mix thoroughly. Prepare this solution fresh monthly.
7.16.3 Cr(VI) calibration solutionsPrepare a set of at least 5 calibration solutions by diluting the Cr(VI) working standard solution with a
1 + 1 diluted alkaline digestion solution (7.15). Add 25 ml of the alkaline digestion solution (7.15) into a
50 ml volumetric flask, pipette accurately the appropriate volume of Cr(VI) working standard solution
(7.16.2) into the volumetric flask and dilute to the mark with water (7.1), close and mix thoroughly.
Prepare these calibration solutions fresh daily.7.16.4 Cr(VI) spiking solutions
The Cr(VI) working standard solution (7.16.2) can be used to spike samples.
7.17 Phosphate buffer solution,
0,5 mol/l dipotassiumhydrogenphosphate (K HPO )/0,5 mol/l potassiumdihydrogenphosphate
2 4(KH PO ), pH 7.
2 4
Dissolve 87,09 g K HPO (7.10) and 68,04 g of KH PO (7.11) in approximately 700 ml of water and swirl
2 4 2 4to mix. Transfer the solution into a 1 l volumetric flask. Dilute to the mark with water.
7.18 Magnesium chloride solutionDissolve 85,4 g MgCl .6H O (7.9) in a 100 ml volumetric flask, dilute to the mark with water (7.1), close
2 2and mix thoroughly.
7.19 Chromium chloride hexahydrate (CrCl .6H O), w(CrCl .6H O) > 96 %
3 2 3 2
7.20 Cr(III) spiking solution
Use a commercial standard solution with a certified Cr(III) concentration, e. g 1 000 mg/l Cr(III)
traceable to national standards. Observe the manufacturer's expiration date or recommended shelf life.
Alternatively dissolve an appropriate known amount of chromium chloride hexahydrate (7.19) in water
(7.1) in a 100 ml volumetric flask, dilute to the mark with water (7.1), close and mix thoroughly. Store
the solution in a polypropylene bottle for a maximum period of 1 year. Before using, determine the Cr
concentration of the spiking solution.8 Sample pretreatment
Samples shall be collected using appropriate devices and placed in containers that do not contain
stainless steel (e. g. plastic, glass).© ISO 2020 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO/DIS 15192:2020(E)
Samples shall be stored field moist at (4 ± 2) °C until analysis. Waste samples shall be homogenised
according to EN 15002, soil samples according to ISO 11464. Soil samples shall preferably be air-dried
before digestion.Particle size reduction below 250 µm is necessary for solid waste and soil especially when Cr(VI) is
suspected to be included in the matrix, whereby heating and contact with stainless steel have to be
avoided.After digestion the sample shall be analysed as soon as possible.
NOTE Cr(VI) has been shown to be quantitatively stable in field moist soil samples for 30 d from the time
of sample collection. In addition, Cr(VI) has also been shown to be stable in the alkaline digest for up to 7 d after
digestion from soil [2].9 Alkaline digestion procedure
9.1 General
Use either the hotplate or heating block method prescribed in 9.2 to prepare test solutions for
determination of Cr(VI) in solid waste materials and soil.9.2 Preparation of test solutions using a hotplate or heating block
9.2.1 Adjust the temperature setting by preparing and monitoring a temperature blank (a 250 ml
vessel filled with 50 ml digestion solution). Maintain a digestion solution temperature of (92,5 ± 2,5) °C.
Do not allow the solution to boil or evaporate to dryness.9.2.2 Transfer (2,5 ± 0,1) g of the test portion weighed to the nearest 0,1 mg into a clean 250 ml
digestion vessel.NOTE For very high expected concentrations of Cr(VI) a smaller representative test portion can be used.
9.2.3 Add (50 ± 1) ml of the alkaline digestion solution (7.15) to each sample using a graduated
cylinder, and also add 1 ml of magnesium chloride solution (7.18) containing approximately 400 mg of
MgCl and 0,5 ml of phosphate buffer solution (7.17). Cover all digestion vessels. If using a heating block,
reflux condensers can be used.9.2.4 Heat the samples to (92,5 ± 2,5) °C with continuous stirring, then maintain the samples at
(92,5 ± 2,5) °C for at least 60 min with stirring continuously.9.2.5 Cool each solution to room temperature. Transfer the contents quantitatively to the filtration
equipment (6.2), rinsing the digestion vessel three times with small portions of water (7.1). Filter through
a 0,45 µm membrane filter (6.3). Rinse the filtration equipment (6.2) with water (7.1) and transfer the
filtrate to a 100 ml volumetric flask and fill up to the mark with water (7.1).NOTE Alternatively the sample may be centrifuged or allowed to settle.
10 Analytical procedure
10.1 General information
The standard method for the determination of Cr(VI) in the alkaline digestion solution is the ion
chromatographic method with spectrophotometric detection as described in this clause.
NOTE In certain cases direct determination of Cr(VI) in the alkaline digestion solution may be possible (see
Annex A).6 © ISO 2020 – All rights reserved
---------------------- Page: 11 ----------------------
ISO/DIS 15192:2020(E)
10.2 Instrumental set-up
10.2.1 Set up the ion chromatograph in accor
...
PROJET DE NORME INTERNATIONALE
ISO/DIS 15192
ISO/TC 190/SC 3 Secrétariat: DIN
Début de vote: Vote clos le:
2020-04-17 2020-07-10
Caractérisation des déchets et des sols — Dosage du
chrome(VI) dans les matériaux solides par digestion
alcaline et chromatographie ionique avec détection
spectrophotométrique
Characterization of soil and waste — Determination of Chromium(VI) in solid material by alkaline
digestion and ion chromatography with spectrophotometric detectionICS: 13.080.10
CE DOCUMENT EST UN PROJET DIFFUSÉ POUR
OBSERVATIONS ET APPROBATION. IL EST DONC
SUSCEPTIBLE DE MODIFICATION ET NE PEUT
Le présent document est distribué tel qu’il est parvenu du secrétariat du comité.
ÊTRE CITÉ COMME NORME INTERNATIONALEAVANT SA PUBLICATION EN TANT QUE TELLE.
OUTRE LE FAIT D’ÊTRE EXAMINÉS POUR
ÉTABLIR S’ILS SONT ACCEPTABLES À DES
FINS INDUSTRIELLES, TECHNOLOGIQUES ET
COMMERCIALES, AINSI QUE DU POINT DE VUE TRAITEMENT PARALLÈLE ISO/CEN
DES UTILISATEURS, LES PROJETS DE NORMES
INTERNATIONALES DOIVENT PARFOIS ÊTRE
CONSIDÉRÉS DU POINT DE VUE DE LEUR
POSSIBILITÉ DE DEVENIR DES NORMES
POUVANT SERVIR DE RÉFÉRENCE DANS LA
RÉGLEMENTATION NATIONALE.
Numéro de référence
LES DESTINATAIRES DU PRÉSENT PROJET
ISO/DIS 15192:2020(F)
SONT INVITÉS À PRÉSENTER, AVEC LEURS
OBSERVATIONS, NOTIFICATION DES DROITS
DE PROPRIÉTÉ DONT ILS AURAIENT
ÉVENTUELLEMENT CONNAISSANCE ET À
FOURNIR UNE DOCUMENTATION EXPLICATIVE. ISO 2020
---------------------- Page: 1 ----------------------
ISO/DIS 15192:2020(F)
ISO/DIS 15192:2020(F)
Sommaire Page
Avant-propos ................................................................................................................................................................... v
Introduction.................................................................................................................................................................... vi
1 Domaine d’application .................................................................................................................................. 7
2 Références normatives .................................................................................................................................. 7
3 Termes et définitions ..................................................................................................................................... 7
4 Consignes de sécurité..................................................................................................................................... 8
5 Principe ............................................................................................................................................................... 8
5.1 Digestion ............................................................................................................................................................. 8
5.2 Dosage ................................................................................................................................................................. 9
5.3 Interférences et sources d’erreur.............................................................................................................. 9
6 Appareillage ...................................................................................................................................................... 9
6.1 Équipement de digestion .............................................................................................................................. 9
6.2 Équipement de filtration ........................................................................................................................... 10
6.3 Membranes filtrantes ................................................................................................................................. 10
6.4 Système de chromatographie ionique .................................................................................................. 10
6.5 Colonne de chromatographie ionique .................................................................................................. 10
6.6 Système de détection .................................................................................................................................. 10
7 Réactifs ............................................................................................................................................................. 10
8 Prétraitement des échantillons ............................................................................................................... 12
9 Mode opératoire de digestion alcaline ................................................................................................. 13
10 Mode opératoire analytique ..................................................................................................................... 13
10.1 Informations générales .............................................................................................................................. 13
10.2 Paramétrage des instruments ................................................................................................................. 14
10.3 Étalonnage ...................................................................................................................................................... 14
10.4 Mesurage des solutions d’essai ............................................................................................................... 14
10.5 Contrôle de la qualité .................................................................................................................................. 15
10.5.1 Généralités ...................................................................................................................................................... 15
10.5.2 Solution d’essai à blanc .............................................................................................................................. 15
10.5.3 Vérification de la méthode ........................................................................................................................ 15
10.5.4 Échantillons en double ............................................................................................................................... 15
10.5.5 Échantillons dopés au Cr(VI) .................................................................................................................... 15
10.5.6 Échantillons dopés au Cr(III) ................................................................................................................... 16
10.5.7 Interprétation des données de contrôle de la qualité ..................................................................... 16
11 Calcul ................................................................................................................................................................. 17
DOCUMENT PROTÉGÉ PAR COPYRIGHT12 Expression des résultats ............................................................................................................................ 17
© ISO 202013 Rapport d’essai .............................................................................................................................................. 17
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en oeuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
Annexe A (informative) Autres méthodes pour le dosage direct du Cr(VI) dans la solution de
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
digestion alcaline.......................................................................................................................................... 18
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright officeAnnexe B (informative) Système de chromatographie ionique ................................................................. 20
Case postale 401 • Ch. de Blandonnet 8CH-1214 Vernier, Geneva
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
© ISO 2020 – Tous droits réservés
iii
E-mail: copyright@iso.org
Website: www.iso.org
Publié en Suisse
ii © ISO 2020 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/DIS 15192:2020(F)
Sommaire Page
Avant-propos ................................................................................................................................................................... v
Introduction.................................................................................................................................................................... vi
1 Domaine d’application .................................................................................................................................. 7
2 Références normatives .................................................................................................................................. 7
3 Termes et définitions ..................................................................................................................................... 7
4 Consignes de sécurité..................................................................................................................................... 8
5 Principe ............................................................................................................................................................... 8
5.1 Digestion ............................................................................................................................................................. 8
5.2 Dosage ................................................................................................................................................................. 9
5.3 Interférences et sources d’erreur.............................................................................................................. 9
6 Appareillage ...................................................................................................................................................... 9
6.1 Équipement de digestion .............................................................................................................................. 9
6.2 Équipement de filtration ........................................................................................................................... 10
6.3 Membranes filtrantes ................................................................................................................................. 10
6.4 Système de chromatographie ionique .................................................................................................. 10
6.5 Colonne de chromatographie ionique .................................................................................................. 10
6.6 Système de détection .................................................................................................................................. 10
7 Réactifs ............................................................................................................................................................. 10
8 Prétraitement des échantillons ............................................................................................................... 12
9 Mode opératoire de digestion alcaline ................................................................................................. 13
10 Mode opératoire analytique ..................................................................................................................... 13
10.1 Informations générales .............................................................................................................................. 13
10.2 Paramétrage des instruments ................................................................................................................. 14
10.3 Étalonnage ...................................................................................................................................................... 14
10.4 Mesurage des solutions d’essai ............................................................................................................... 14
10.5 Contrôle de la qualité .................................................................................................................................. 15
10.5.1 Généralités ...................................................................................................................................................... 15
10.5.2 Solution d’essai à blanc .............................................................................................................................. 15
10.5.3 Vérification de la méthode ........................................................................................................................ 15
10.5.4 Échantillons en double ............................................................................................................................... 15
10.5.5 Échantillons dopés au Cr(VI) .................................................................................................................... 15
10.5.6 Échantillons dopés au Cr(III) ................................................................................................................... 16
10.5.7 Interprétation des données de contrôle de la qualité ..................................................................... 16
11 Calcul ................................................................................................................................................................. 17
12 Expression des résultats ............................................................................................................................ 17
13 Rapport d’essai .............................................................................................................................................. 17
Annexe A (informative) Autres méthodes pour le dosage direct du Cr(VI) dans la solution de
digestion alcaline.......................................................................................................................................... 18
Annexe B (informative) Système de chromatographie ionique ................................................................. 20
© ISO 2020 – Tous droits réservésiii
---------------------- Page: 3 ----------------------
ISO/DIS 15192:2020(F)
Annexe C (informative) Exigences pour la préparation de la prise d’essai ............................................ 21
Annexe D (informative) Validation ....................................................................................................................... 22
Bibliographie ................................................................................................................................................................ 26
© ISO 2020 – Tous droits réservés---------------------- Page: 4 ----------------------
ISO/DIS 15192:2020(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le
droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2
(voir www.iso.org/directives).L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant les
références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www.iso.org/iso/fr/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 190, Qualité du sol, sous-comité SC 3,
Caractérisation chimique et physique.Cette deuxième édition annule et remplace la première édition (ISO 15192:2010), qui a fait l’objet d’une
révision technique.Les principales modifications par rapport à l’édition précédente sont les suivantes :
— révision éditoriale du texte, notamment mise à jour des références ;— suppression de l’Annexe D.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html.© ISO 2020 – Tous droits réservés
---------------------- Page: 5 ----------------------
ISO/DIS 15192:2020(F)
Introduction
Dans les conditions environnementales, le chrome présent dans des composés existe à l’état trivalent,
Cr(III), ou hexavalent, Cr(VI). Le Cr(III) est un élément trace indispensable aux mammifères, y compris à
l’Homme, tandis que les composés du Cr(VI) sont présumés génotoxiques et potentiellement
cancérogènes pour l’être humain. La conversion des espèces de chrome trivalent et hexavalent peut se
produire pendant la préparation des échantillons et l’analyse des échantillons, mais ces processus sont
réduits au minimum, dans la mesure du possible, par les méthodes de préparation des échantillons
spécifiées dans la présente norme.© ISO 2020 – Tous droits réservés
---------------------- Page: 6 ----------------------
PROJET DE NORME INTERNATIONALE ISO/DIS 15192:2020(F)
Caractérisation des déchets et des sols — Dosage du
chrome(VI) dans les matériaux solides par digestion alcaline
et chromatographie ionique avec détection
spectrophotométrique
1 Domaine d’application
Le présent document décrit le dosage du Cr(VI) dans les déchets solides et les sols par digestion alcaline
et chromatographie ionique avec détection spectrophotométrique. Cette méthode peut être utilisée
pour déterminer les fractions massiques de Cr(VI) dans les solides supérieures à 0,1 mg/kg.
NOTE Il n’est pas possible de consigner une teneur en Cr(VI) valable dans un rapport lorsque la matrice de
déchets est réductrice ou oxydante.2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s’applique (y compris les
éventuels amendements).ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d’essai.
ISO 11464, Qualité du sol — Prétraitement des échantillons pour analyses physico-chimiques.
ISO 11465, Qualité du sol — Détermination de la teneur pondérale en matière sèche et en eau — Méthode
gravimétrique.ISO/IEC 17025, Exigences générales concernant la compétence des laboratoires d’étalonnages et d’essais.
EN 15002, Caractérisation des déchets — Préparation de prises d’essai à partir de l’échantillon pour
laboratoire.EN 15934, Boues, bio-déchets traités, sols et déchets — Calcul de la teneur en matière sèche par
détermination du résidu sec ou de la teneur en eau.3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes :— IEC Electropedia : disponible à l’adresse http://www.electropedia.org/ ;
— ISO Online browsing platform : disponible à l’adresse http://www.iso.org/obp.
© ISO 2020 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO/DIS 15192:2020(F)
3.1
digestion alcaline
procédé consistant à obtenir une solution contenant l’analyte recherché, à partir d’un échantillon placé
dans des conditions alcalines. La digestion alcaline peut, ou non, impliquer la dissolution totale de
l’échantillon3.2
analyse de spéciation
activités consistant à mesurer la quantité d’une ou de plusieurs espèces chimiques individuelles dans
un échantillon, par exemple le Cr(VI) dans un échantillon particulier ou une matrice particulière
4 Consignes de sécuritéToute personne intervenant dans le cadre de l’analyse des sols et des déchets doit connaître les risques
types liés à ce matériau, quels que soient les paramètres déterminés. Les échantillons de sols et de
déchets peuvent contenir des substances dangereuses (par exemple toxiques, réactives, inflammables,
infectieuses), qui peuvent donner lieu à une réaction biologique et/ou chimique. Il est, par conséquent,
recommandé de manipuler ces échantillons avec un soin particulier. Les gaz qui peuvent être produits
par une activité microbiologique ou chimique sont potentiellement inflammables et peuvent mettre
sous pression les flacons fermés. L’éclatement des flacons peut produire des éclats, de la poussière
et/ou des aérosols dangereux. Il convient de respecter la réglementation nationale en ce qui concerne
l’ensemble des risques associés à la présente méthode.Éviter tout contact avec la peau et toute ingestion ou inhalation de composés du Cr(VI). Les composés
du Cr(VI) sont génotoxiques et potentiellement cancérogènes pour l’Homme.5 Principe
5.1 Digestion
Le présent document décrit un mode opératoire de digestion alcaline pour l’extraction du Cr(VI) à
partir des formes solubles, adsorbées et précipitées des composés du chrome présents dans les déchets
solides et les sols. Pour quantifier la teneur en Cr(VI) dans une matrice solide, trois critères doivent être
remplis :1) la solution de digestion doit solubiliser tous les composés contenant du Cr(VI) ;
2) les conditions de la digestion ne doivent induire aucune réduction du Cr(VI) natif en Cr(III) ;
3) la méthode ne doit pas provoquer l’oxydation en Cr(VI) du Cr(III) natif contenu dans l’échantillon.
La digestion alcaline décrite dans le présent document remplit ces critères pour un large éventail de
matrices solides. Dans les conditions alcalines de la digestion, la réduction du Cr(VI) ou l’oxydation du
Cr(III) natif sont attendues dans des proportions négligeables. L’ajout, à la solution alcaline, de Mg en
solution tampon de phosphate empêche l’oxydation à l’air du chrome trivalent [1], [5], [8].
NOTE Des informations théoriques relatives aux méthodes de dosage du Cr(VI) dans les échantillons solides
sont données en [3], [4], [5].© ISO 2020 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO/DIS 15192:2020(F)
5.2 Dosage
Il convient de réaliser la quantification du Cr(VI) dans la solution de digestion alcaline en utilisant une
méthode adéquate, d’une exactitude appropriée. La chromatographie ionique est utilisée dans ce but
pour séparer le Cr(VI) des interférences. À la suite de cette séparation par chromatographie ionique, le
Cr(VI) est mesuré par spectrophotométrie à 365 nm (détection UV directe) ou bien à 540 nm après
dérivation post-colonne par la 1,5-diphénylcarbazide en solution acide. La dérivation post-colonne
entraîne une réaction de la 1,5-diphénylcarbazide avec le Cr(VI), qui produit du chrome trivalent et de
la diphénylcarbazone. Tous deux se combinent ensuite pour former un complexe chrome
trivalent-diphénylcarbazone contenant le chromophore magenta caractéristique (λ = 540 nm).
maxNOTE Le choix de la méthode de détection s’effectue en fonction de la sensibilité requise. La détection UV
directe est moins sensible que la détection après dérivation post-colonne par la 1,5-diphénylcarbazide.
Des méthodes combinées associant une séparation par chromatographie ionique avec des techniques
de détection telles que la spectrométrie de masse avec plasma à couplage inductif (ICP/MS) ou la
spectroscopie d’émission atomique avec plasma à couplage inductif (ICP/AES) peuvent être utilisées
une fois que la méthode analytique choisie a été validée.5.3 Interférences et sources d’erreur
— L’utilisation de la chromatographie ionique est nécessaire pour séparer le Cr(VI) d’interférences
possibles dans la solution de digestion alcaline du matériau solide [6].— Pour les déchets ou les sols dans lesquels on attend un rapport Cr(III)/Cr(VI) élevé, les résultats
relatifs à Cr(VI) peuvent être faussés en raison d’une oxydation induite par la méthode. Ceci est
particulièrement le cas dans les sols ayant une teneur élevée en Mn et amendés avec des sels
solubles de Cr(III) ou du Cr(OH) fraîchement précipité [3].— Le Cr(VI) peut être réduit en Cr(III) pendant la digestion de l’échantillon, en raison d’une réaction
avec des agents réducteurs, le fer divalent par exemple. Ce problème est réduit au minimum dans le
mode opératoire décrit du fait de l’utilisation d’une solution de digestion alcaline [5].
— Le Cr(III) peut être oxydé en Cr(VI) dans les solutions alcalines chaudes. Le problème est réduit au
minimum dans le mode opératoire décrit du fait de l’ajout de magnésium à la solution de digestion
alcaline [2], [3], [5], [8].— Une surcharge de la capacité de la colonne analytique avec des concentrations élevées d’espèces
anioniques (chlorure par exemple) peut causer une sous-estimation du Cr(VI) [9].6 Appareillage
6.1 Équipement de digestion
— Plaque chauffante avec agitateur magnétique, contrôlée par thermostat, avec un récipient de
digestion de 250 ml recouvert d’un verre de montre ; ou— Bloc chauffant avec agitateur magnétique, contrôlé par thermostat, avec un récipient de digestion
de 250 ml recouvert d’un verre de montre.NOTE D’autres équipements de digestion contrôlés par thermostat et à agitateur magnétique peuvent être
utilisés après validation.© ISO 2020 – Tous droits réservés
---------------------- Page: 9 ----------------------
ISO/DIS 15192:2020(F)
6.2 Équipement de filtration
Compatible avec les membranes filtrantes de porosité 0,45 µm.
6.3 Membranes filtrantes
Porosité 0,45 µm, inertes chimiquement.
6.4 Système de chromatographie ionique
Toutes les tubulures de raccordement et tous les éléments amenés à être en contact avec l’échantillon
ou le flux d’élution doivent être composés de matériaux inertes, par exemple le polyétheréthercétone
(PEEK) (voir l’Annexe B).6.5 Colonne de chromatographie ionique
Prévue pour la séparation des chromates et possédant une capacité d’échange ionique suffisante.
6.6 Système de détection— Spectrophotomètre UV-VIS à 365 nm ; ou
— Spectrophotomètre pour rayonnement visible à 540 nm après dérivation post-colonne.
7 RéactifsAu cours de l’analyse, utiliser uniquement des réactifs de qualité analytique reconnue et de l’eau comme
spécifié en 7.1.7.1 Eau
Eau satisfaisant aux exigences de l’ISO 3696 pour l’eau de qualité 2 (conductivité électrique inférieure à
0,1 mS m , équivalente à une résistivité supérieure à 0,01 MΩ m à 25 °C). Il est recommandé que l’eau
utilisée provienne d’un système de purification qui délivre de l’eau ultra-pure ayant une résistivité
supérieure à 0,18 MΩ m (soit 18 MΩ cm selon la désignation habituelle des fabricants de systèmes de
purification d’eau).7.2 Acide sulfurique concentré (H SO )
2 4
Concentré, ρ(H SO ) ~ 1,84 g/ml, w(H SO ) ~ 98 %
2 4 2 4
7.3 Carbonate de sodium (Na CO )
2 3
Anhydre, w(Na CO ) > 99,9 %
2 3
7.4 1,5-Diphénylcarbazide ((C H .NH.NH) CO)
6 5 2
w((C H .NH.NH) CO) > 98 %
6 5 2
7.5 Propanone (acétone) (C H O)
3 6
7.6 Méthanol (CH O)
© ISO 2020 – Tous droits réservés
---------------------- Page: 10 ----------------------
ISO/DIS 15192:2020(F)
7.7 Dichromate de potassium (K2Cr2O7), w(K2Cr2O7) > 99,9 %
Déshydrater jusqu’à masse constante à 110 °C, refroidir et conserver dans un dessiccateur.
7.8 Hydroxyde de sodium (NaOH), w(NaOH) > 99 %7.9 Chlorure de magnésium hexahydraté (MgCl .6H O), w(MgCl .6H O) > 99 %
2 2 2 2
7.10 Hydrogénophosphate de dipotassium (K HPO ), w(K HPO ) > 99 %
2 4 2 4
7.11 Dihydrogénophosphate de potassium (KH PO ), w(KH PO ) > 99 %
2 4 2 4
7.12 Chromate de plomb (PbCrO ), w(PbCrO ) > 99 %
4 4
7.13 Solution de réactif
...