Materials and articles in contact with foodstuffs - Certain epoxy derivatives subject to limitation - Determination of NOGE and its hydroxy and chlorinated derivatives

This European standard describes the determination of NOGE components with more than two aromatic rings (the two-ring NOGE is equal to BFDGE = Bis(2-hydroxyphenyl)methane bis(2,3-epoxypropyl)ether) and at least one epoxy group as well as their derivatives containing chlorohydrin functions and having a molecular mass less than 1000 Daltons in can coatings.
A high performance liquid chromatography (HPLC) method is employed based on reversed phase HPLC and fluorescence detection.
The method is capable of determining NOGE and its derivatives at a minimum level of 1 mg/ml in solution.
Direct HPLC analysis of the can coating extract may result in chromatograms difficult to interpret, due to interference from other components or the instability of the monomer resulting in a complex mixture of derivatives and/or reaction products. By forced hydrolysis of all epoxy groups and their reaction products, the quantification of the NOGE is simplified and the identities of the substances are indicatively confirmed.
NOTE   In this European standard the term “NOGE and its derivatives” refers to the requirements of Directive 2002/16/EC [1]. This includes NOGE components with more than two aromatic rings and at least one epoxy group as well as their derivatives containing chlorohydrin functions and having a molecular mass less than 1000 Daltons.

Werkstoffe und Gegenstände in Kontakt mit Lebensmitteln - Bestimmte Epoxyderivate, die Beschränkungen unterliegen - Bestimmung von NOGE und dessen Hydroxy- und Chlorderivaten

Diese Europäische Norm beschreibt die Bestimmung von NOGE-Bestandteilen mit mehr als zwei aromatischen Ringen (NOGE mit zwei Ringen entspricht BFDGE = Bis(2 hydroxyphenyl)methan-bis-(2,3-epoxypropyl)ether) und mindestens einer Epoxygruppe sowie von deren Derivaten mit Chlorhydrinfunktionen und einer relativen Molmasse von weniger als 1 000 Dalton in Beschichtungen von Dosen.
Angewendet wird ein Verfahren der Hochleistungs-Flüssigkeitschromatographie (HPLC), das auf Umkehrphasen-HPLC und Fluoreszenzdetektion beruht.
Das Verfahren ist für die Bestimmung von NOGE und dessen Derivaten bei einem Mindestgehalt von 1 mg/ml Lösung geeignet.
Die direkte HPLC-Analyse des Extraktes von Dosenbeschichtungen kann zu Chromatogrammen führen, die auf Grund von Interferenzen durch andere Bestandteile oder der Instabilität des Monomers, die zu einer komplexen Mischung von Derivaten und/oder Reaktionsprodukten führt, schwer auszuwerten sind. Durch beschleunigte Hydrolyse aller Epoxygruppen und von deren Reaktionsprodukten wird die quantitative Bestimmung von NOGE vereinfacht und die Identitäten der Substanzen werden nachweislich bestätigt.
ANMERKUNG   In dieser Europäischen Norm bezieht sich der Ausdruck „NOGE und dessen Derivate“ auf die Anforderungen in der Richtlinie 2002/16/EG [1] und ihrer Änderung, Richtlinie 2004/13/EG [2]. Dazu gehören NOGE-Bestandteile mit mehr als zwei aromatischen Ringen und mindestens einer Epoxygruppe sowie deren Derivate mit Chlorhydrinfunktionen und einer Molekülmasse von weniger als 1 000 Dalton.

Matériaux et objets en contact avec des denrées alimentaires - Dérivés époxy soumis a des limitations - Détermination des NOGE et de leurs dérivés hydroxylés et chlorés

La présente Norme européenne décrit une méthode de détermination des composants NOGE ayant plus de deux
noyaux aromatiques (les NOGE a deux noyaux sont égaux au BFDGE (éthers bis(2,3-époxypropyliques) du
bis(hydroxyphényl)méthane) et au moins un groupe époxy et de leurs dérivés chlorés de masse moléculaire
inférieure a 1 000 daltons dans les revetements de boîtes de conserve.
La détermination est effectuée par chromatographie liquide haute performance (CLHP) en phase inverse et
détection par fluorescence.
Cette méthode permet de déterminer les NOGE ainsi que leurs dérivés a une concentration minimale de 1 mg/ml
de solution.
Une analyse CLHP directe de l’extrait du revetement de boîte de conserve peut donner des chromatogrammes
difficiles a interpréter en raison d'une interférence avec d'autres composants ou de l'instabilité du monomere
engendrant un mélange complexe de dérivés et/ou de produits de réaction. L'hydrolyse forcée de tous les groupes
époxy et de leurs produits de réaction permet de simplifier la quantification des NOGE et de confirmer l'identité des
substances.
NOTE Dans la présente Norme européenne, l’expression - NOGE et leurs dérivés - fait référence aux exigences de la
Directive 2002/16/CE [1] et de son amendement, la Directive 2004/13/CE [2]. Elle inclut les composants NOGE a plus de deux
noyaux aromatiques et au moins un groupe époxy ainsi que leurs dérivés chlorés et présentant une masse moléculaire
inférieure a 1 000 daltons.

Materiali in predmeti v stiku z živili – Nekateri epoksi derivati, katerih koncentracija je omejena - Določevanje NOGE in njihovih hidroksi in kloriranih derivatov

General Information

Status
Published
Publication Date
31-Aug-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Sep-2006
Due Date
01-Sep-2006
Completion Date
01-Sep-2006

Buy Standard

Standard
EN 15137:2006
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Materials and articles in contact with foodstuffs - Certain epoxy derivatives subject to limitation - Determination of NOGE and its hydroxy and chlorinated derivativesGHULYDWRYMatériaux et objets en contact avec des denrées alimentaires - Dérivés époxy soumis a des limitations - Détermination des NOGE et de leurs dérivés hydroxylés et chlorésWerkstoffe und Gegenstände in Kontakt mit Lebensmitteln - Bestimmte Epoxyderivate, die Beschränkungen unterliegen - Bestimmung von NOGE und dessen Hydroxy- und ChlorderivatenTa slovenski standard je istoveten z:EN 15137:2006SIST EN 15137:2006en,fr,de67.250ICS:SLOVENSKI
STANDARDSIST EN 15137:200601-september-2006







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15137March 2006ICS 67.250; 71.040.40 English VersionMaterials and articles in contact with foodstuffs - Certain epoxyderivatives subject to limitation - Determination of NOGE and itshydroxy and chlorinated derivativesMatériaux et objets en contact avec des denréesalimentaires - Dérivés époxy soumis à des limitations -Détermination des NOGE et de leurs dérivés hydroxylés etchlorésWerkstoffe und Gegenstände in Kontakt mit Lebensmitteln- Bestimmte Epoxyderivate, die Beschränkungenunterliegen - Bestimmung von NOGE und dessen Hydroxy-und ChlorderivatenThis European Standard was approved by CEN on 23 January 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15137:2006: E



EN 15137:2006 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.5 2 Normative references.5 3 Principle.5 4 Reagents.6 5 Apparatus.8 6 Samples.9 7 Procedure.11 8 Precision.14 9 Confirmation.14 10 Test report.15 Annex A (informative)
The 7 positional 3-ring NOGE isomers.16 Annex B (informative)
Substances that may occur in an HPLC chromatogram of a can coating.18 Annex C (informative)
Principle of the determination of the content of NOGE and its hydroxy and chlorinated derivatives in can coatings.20 Annex D (informative)
Typical chromatogram of NOGE standard, before and after hydrolysis.21 Annex ZA (informative)
Relationship between this
European
Standard and the Essential Requirements
of EU Directives.23 Bibliography.24



EN 15137:2006 (E) 3 Foreword This document (EN 15137:2006) has been prepared by Technical Committee CEN/TC 194 “Utensils in contact with food”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2006, and conflicting national standards shall be withdrawn at the latest by September 2006. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document should be read in conjunction with EN 13130-1. WARNING:
All chemicals are hazardous to health to a greater or lesser extent.
It is beyond the scope of this European standard to give instructions for the safe handling of all chemicals, that meet, in full, the legal obligations in all countries in which this European standard may be followed.
Therefore, specific warnings are not given and users of this European standard should ensure that they meet all the necessary safety requirements in their own country. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 15137:2006 (E) 4 Introduction NOGE (Novolac glycidyl ethers) is used as a monomer in the manufacture of certain polymeric food contact materials and articles.
The main application of NOGE is in epoxy coatings for cans and ends. The substance may also be used in organosol coatings. After the manufacture, residues of NOGE or its reaction products can remain in the finished product and may migrate into foodstuffs coming into contact with that product.
The analytical method described allows for the determination NOGE and its reaction products in can coatings.



EN 15137:2006 (E) 5 1 Scope
This European standard describes the determination of NOGE components with more than two aromatic rings (the two-ring NOGE is equal to BFDGE = Bis(2-hydroxyphenyl)methane bis(2,3-epoxypropyl)ether) and at least one epoxy group as well as their derivatives containing chlorohydrin functions and having a molecular mass less than 1000 Daltons in can coatings. A high performance liquid chromatography (HPLC) method is employed based on reversed phase HPLC and fluorescence detection.
The method is capable of determining NOGE and its derivatives at a minimum level of 1 µg/ml in solution. Direct HPLC analysis of the can coating extract may result in chromatograms difficult to interpret, due to interference from other components or the instability of the monomer resulting in a complex mixture of derivatives and/or reaction products. By forced hydrolysis of all epoxy groups and their reaction products, the quantification of the NOGE is simplified and the identities of the substances are indicatively confirmed.
NOTE In this European standard the term “NOGE and its derivatives” refers to the requirements of Directive 2002/16/EC [1] and its amendment, Directive 2004/13/EC [2]. This includes NOGE components with more than two aromatic rings and at least one epoxy group as well as their derivatives containing chlorohydrin functions and having a molecular mass less than 1000 Daltons. 2 Normative references The following referenced documents are indispensable for the application of this European standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13130-1:2004, Materials and articles in contact with foodstuffs – Plastics substances subject to limitation – Part 1: Guide to the test methods for the specific migration of substances from plastics to foods and food simulants and the determination of substances in plastics and the selection of conditions of exposure to food simulants 3 Principle
3.1 Determination of NOGE and derivatives in a can coating Can coatings are extracted with acetonitrile for 24 h at room temperature. Then the extraction solvent is injected into a reverse phase HPLC column. The substances are separated using a gradient elution profile. Detection is performed by means of fluorescence detection. Identification is based on retention time and comparison with reference substances, fluorescence and UV detection response. For confirmation and quantification of NOGE and derivatives the epoxy and the chlorohydrin containing components are fully hydrolysed in alkaline medium at elevated temperature to form the diol components. The hydrolysed components (NOGE per H2O) are separated by HPLC using fluorescence detection. The NOGE per H2O components will appear early in the chromatogram due to the increased polarity of the hydrolysed components. Compared to the HPLC chromatogram prior to hydrolysis a simpler HPLC chromatogram is obtained after hydrolysis, containing fewer peaks because all epoxy components and chlorohydrin derivatives disappear; if a peak remains then this substance shall be considered an interfering substance originating from the matrix. To establish compliance with the restrictions set the total amount of diol substances is determined. If relevant, the total amount of NOGE per H2O derivatives is reduced with the amount of NOGE per H2O derivatives present initially, prior to hydrolysis.



EN 15137:2006 (E) 6 3.2 Hydrolysis NOGE and its partly hydrolysed adducts hydrolyse in aqueous neutral and acid conditions. The chlorinated adducts are stable in acid conditions and hydrolyse only slowly in neutral aqueous media. However, in slightly alkaline conditions all adducts (excepting ether derivatives) hydrolyse to the NOGE per H2O components. To force complete hydrolysis of the epoxy and HCl adducts, the sample solutions are buffered at pH 8.5 and subsequently stored for a minimum of 20 h at 100 °C. After that period the NOGE per H2O substances are determined. NOTE 1 Some structures of NOGE and derivatives are shown in Annex A and B.
NOTE 2 A flow chart showing the principle of the determination of NOGE and derivatives in can coatings is given in Annex C. 4 Reagents
4.1 Analytes 4.1.1 Poly(phenyl glycidyl ether)-co-formaldehyde CAS no 28064-14-4
The analyte substance contains approximately 40% of NOGE with 3 – 6 aromatic rings, but batch and supplier variations may occur. Average Mn approximately 345; Average epoxy groups per molecule, 2.2. 4.1.2 BFDGE.2H2O
CAS no 72406-26-9
4.1.3 BFDGE
CAS no 2095-03-6
NOTE 1 NOGE and its derivatives consist of a mixture of isomers (see Annexes A and D). The ratio of the various isomers may differ, depending on the supply source. Also the composition of the reference material may vary, depending on supply source and Lot number. NOTE 2 The substances of interest are those with more than two aromatic rings and at least one epoxy group as well as their derivatives containing chlorohydrin functions and having a molecular mass less than 1000 Dalton.
4.2 Reagents NOTE During the analysis, unless otherwise stated, only reagents of recognized analytical grade and distilled water of equivalent purity should be used. 4.2.1 Acetonitrile, HPLC grade 4.2.2 Boric acid 4.2.3 Methanol, HPLC grade 4.2.4 Sodium hydroxide 4.2.5 Water deionised, HPLC grade 4.3 Solutions 4.3.1 Borate buffer: 0,6 M
Dissolve 9,28 g of boric acid in 220 ml of water. Add 4,5 M sodium hydroxide solution to a pH of 8,5. Fill the volume to 250 ml with water.



EN 15137:2006 (E) 7 4.3.2 Reference solutions of NOGE in acetonitrile (4 mg/ml) Weigh to the nearest 0,1 mg approximately 100 mg of NOGE (4.1) in a 25 ml volumetric flask. Fill the volumetric flask up to the mark with acetonitrile and mix carefully. Calculate the concentration of the substance in milligrams per millilitre solution. 4.3.3 Intermediate reference solution of NOGE in acetonitrile (160 µg/ml)
Pipette 1,0 ml of the stock solution (4.3.2) into a 25 ml volumetric flask and fill the flask up to the mark with acetonitrile to give a solution containing approximately 160 µg/ml of NOGE. NOTE 1 The solutions prepared contain approximately 40 % of the components of interest (NOGE with 3 to 6 aromatic rings).
NOTE 2 The solutions may be stored for up to 6 months in a refrigerator at a temperature between 4 ºC and 10 ºC. 4.3.4 Standard stock solutions of BFDGE in acetonitrile (500 µg/ml) Weigh to the nearest 0,1 mg approximately 50 mg of BFGDE (4.1.3) in a 100 ml volumetric flask and add 80 ml acetonitrile (4.2.1), and mix thoroughly to dissolve the BFDGE. Fill the volumetric flask up to the mark with acetonitrile and mix carefully. Calculate the actual concentration of BFDGE in micrograms per millilitre of solution. Repeat the procedure to obtain a second standard stock solution. Check the two primary standard solutions of analyte against one another. Check that the response factor, i.e. detector response divided by concentration of analyte solution, of the two primary standard solutions (or dilutions of that) does not differ by more than 5 %. If there is agreement within 5 %, make subsequent diluted standard solutions from only one of the primary standard solutions.
If the levels of the two independently prepared stock solutions do not correspond to within ± 5 %, discard both stock solutions and prepare new solutions. 4.3.5 Intermediate standard solution of BFDGE in acetonitrile (10 µg/ml)
Into a 50 ml volumetric flask pipette 1,0 ml of the BFDGE stock solution (4.3.4) and fill the volumetric flask up to the mark with acetonitrile and mix carefully. Calculate the actual concentration of BFDGE in µg/ml solution. NOTE The solutions may be stored for up to 6 months in a refrigerator at a temperature between 4 ºC and 10 ºC.
4.3.6 Sodium hydroxide solution in water; 4,5 M Dissolve 18 g of NaOH in 100 ml of water.



EN 15137:2006 (E) 8 5 Apparatus 5.1 Analytical balance, capable of weighing accurately to 0,1 mg.
5.2 HPLC vials. 5.3 Headspace vials of suitable volume, with inert gas-tight closure capable of sustaining the build-up of pressure during the heating period. 5.4 Micro pipette. 5.5 Oven, capable of being maintained at 100 ºC ± 5 °C. 5.6 pH meter, accurate to within ± pH 0,1. 5.7 Mixer of vortex type. 5.8 Reaction-therm heating module with nitrogen gas flow supply and the temperature set to between 40 °C to 50 °C. 5.9 HPLC apparatus 5.9.1 High performance liquid chromatograph provided with an injector, 20 µl to 50 µl, a UV detector at 225 nm, and a variable fluorescence detector, set to λex =275 nm and λem =305 nm, detectors should be connected to an integrator.
NOTE For the determination of NOGE the use of the prescribed fluorescence wavelengths is essential. Alternative wavelengths may provide better sensitivity but the response factor for the various isomers is different, making correct quantification impossible. 5.9.2 HPLC column, capable of producing symmetric peaks of NOGE, and capable of separating NOGE from the hydrolysis products of NOGE, as well as from peaks originating from the matrix/or solvents used. For the determination of NOGE and adducts a reverse phase HPLC procedure with a gradient profile is applied, using an analytical column and a pre-column packed with C18 coated silica.
NOTE For guidance, the parameters which are found suitable for the analysis, using the column selected are given below. Other columns and dimensions have also been found to be suitable.
HPLC SYSTEM Analytical Column : Stainless steel 250 mm x 4,6 mm, Spherisorb ODS2, partical size 5 µm Pre Column
: Stainless steel 30 mm x 4,6 mm, Hypersil ODS, partical size 5 µm Column temperature : 40 °C
Flow
: 1.1 ml/min Eluent gradient
: The following gradient profile, using a linear gradient in each step, is applied:



EN 15137:2006 (E) 9
Time (min) % water % acetonitrile 0 80 20 60 0 100 75 0 100 80 80 20 85 80 20
Depending on the composition of the samples injected, the final step(s) in the gradient can be adapted or shortened. In case of strongly contaminated solutions it is advised to rinse the HPLC column properly with pure acetonitrile in between successive injections. If mainly clean samples are injected then the pre column may not be required. This will reduce the retention times presented below. Injection volume:
20 µl to 50 µl
Detection:
See 5.9.1 Under the conditions given above the following retention times were obtained from standard solutions. Typical chromatograms are depicted in Figures 3 and 4. Component Retention time(min) Component Retention time (min) p,p-BFDGE.2H2O 10,5 p,p-BFDGE 29,6 o,p-BFDGE.2H2O 11,9 o,p-BFDGE 30,4 o,o-BFDGE.2H2O 13,0 o,o-BFDGE 31,3 p,p-BFDGE.1H2O 17,9 3-ring NOGE_isomers 35,8 to 37,9 o,p-BFDGE.1H2O 18,7 4-ring NOGE_isomers 37,9 to 42,0 o,o-BFDGE.1H2O 19,5 5-ring NOGE_isomers 42,0 to 45,3 NOGE.per H2O (3 ring isomers) 13,2 to 14,2 6-ring NOGE isomers 45,3 to 47,7 NOGE.per H2O (4 ring isomers) 14,2 to 16,7
NOGE.per H2O (5 ring isomers) 16,7 to 22,5
NOGE.per H2O (56 ring isomers) 22,5 to 27,0
6 Samples
6.1 Preparation of test samples from can coatings 6.1.1 Extraction of the can coating Extract 1 dm² of can coating for 24 h at room temperature with 33 ml acetonitrile.
After extraction, fill a HPLC vial with the solution thus obtained and continue as described in 7.3. NOTE 1 To confirm complete extraction a second extraction period for 24 h at room temperature using a fresh portion of acetonitrile is advised. When there is evidence that the extraction is completed within the 24 h extraction period, a second extraction is not required.



EN 15137:2006 (E) 10 NOTE 2 Shorter extraction times using elevated temperature are acceptable when there is proof that the extraction is completed during the applied alternative test conditions If for practical reasons the applied volume/surface ratio is higher than 33 ml/dm², concentrate the final volume of the acetonitrile extract to a defined volume to obtain a ratio of approximately 33 ml/dm².
NOTE 3 Organosol coatings in which NOGE has been used as a stabilizer may contain high quantities of NOGE and its derivatives. For these samples the extraction volume of acetonitrile used may be significantly higher in order to maintain within the range of the calibration curve. Absolute quantificat
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.