Metallic coatings -- Porosity tests -- Ferroxyl test

Lays down a method of revealing pores or other discontinuities, when testing metallic coatings, that are not visibly affected by ferricyanide and chloride ions during the test period and that are cathodic to iron and steel. This method is especially useful for thick, hard chromium coatings used for wear resistance.

Revêtements métalliques -- Essais de porosité -- Essai au ferroxyle

Kovinske prevleke - Preskus ugotavljanja poroznosti – Preskus ferroxyl

General Information

Status
Withdrawn
Publication Date
30-Sep-1999
Withdrawal Date
25-May-2016
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
25-May-2016
Due Date
17-Jun-2016
Completion Date
26-May-2016

Relations

Effective Date
01-Jul-2016

Overview

SIST ISO 10309:1999 specifies a standardized method for porosity testing of metallic coatings using the Ferroxyl test. This test detects pores and discontinuities in metallic coatings that are cathodic to iron and steel but are not visibly affected by ferricyanide and chloride ions during the testing period. It is particularly effective for thick, hard chromium coatings applied for wear resistance.

The Ferroxyl test is essential in quality control to ensure coating integrity by revealing microscopic defects that could compromise corrosion protection and longevity. This standard ensures reliable and repeatable porosity analysis for manufacturers, laboratories, and quality management systems in industries utilizing metal plating and protective coatings.

Key Topics

  • Scope & Application
    Identifies pores or cracks in metallic coatings like chromium that are otherwise invisible to standard chemical exposure tests.

  • Principle
    Utilizes treated test paper saturated with sodium chloride and a ferricyanide solution. When applied to the coating surface, base metal ions migrating through discontinuities create a distinct blue coloration on the test paper, indicating porosity.

  • Reagents & Materials

    • Sodium chloride solution with a non-ionic wetting agent and gelatin or agar for gelling properties
    • Potassium hexacyanoferrate(III) (potassium ferricyanide) solution as the indicator
    • High-purity analytical reagents and distilled or deionized water compliant with ISO 3696 standards
  • Test Procedure

    • Surface cleaning and degreasing using solvents, e.g., trichloroethane
    • Preparation of test paper strips impregnated with sodium chloride solution
    • Pressing wet test paper onto the test surface for about 10 minutes
    • Development of test paper in potassium ferricyanide solution to reveal blue spots at discontinuities
    • Visual examination and counting of blue markings to quantify porosity
  • Results Expression
    Porosity is expressed as the average or maximum number of pores per square centimeter using a 10 mm x 10 mm counting template.

  • Reporting
    Test reports should include the ISO standard number, test area, coating or product reference, and measured results.

Applications

  • Corrosion Resistance Testing
    Critical for assessing protective metallic coatings’ integrity against corrosion agents.

  • Quality Assurance in Plating Industries
    Used extensively in industries applying wear-resistant chromium coatings or other metallic layers to ensure uniform coverage and absence of defects.

  • Failure Analysis and Maintenance
    Helps identify coating flaws potentially causing early failure, guiding corrective actions before product deployment.

  • Research and Development
    Facilitates development of improved coating processes by providing a reliable porosity detection method.

Related Standards

  • ISO 3696 - Water for analytical laboratory use - Specification and test methods
  • Other ISO standards on corrosion tests and metallic coatings, supporting comprehensive evaluation of coated materials
  • Relevant ISO/TC 107 committee documents for metal and inorganic coatings standardization

Keywords: ISO 10309, Ferroxyl test, metallic coatings, porosity test, chromium coating porosity, corrosion resistance testing, coating discontinuities, potassium ferricyanide test, sodium chloride solution, quality assurance in metal plating.

Standard

ISO 10309:1994 - Metallic coatings -- Porosity tests -- Ferroxyl test

English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 10309:1994 - Revetements métalliques -- Essais de porosité -- Essai au ferroxyle

French language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 10309:1994 - Revetements métalliques -- Essais de porosité -- Essai au ferroxyle

French language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

SIST ISO 10309:1999 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Metallic coatings -- Porosity tests -- Ferroxyl test". This standard covers: Lays down a method of revealing pores or other discontinuities, when testing metallic coatings, that are not visibly affected by ferricyanide and chloride ions during the test period and that are cathodic to iron and steel. This method is especially useful for thick, hard chromium coatings used for wear resistance.

Lays down a method of revealing pores or other discontinuities, when testing metallic coatings, that are not visibly affected by ferricyanide and chloride ions during the test period and that are cathodic to iron and steel. This method is especially useful for thick, hard chromium coatings used for wear resistance.

SIST ISO 10309:1999 is classified under the following ICS (International Classification for Standards) categories: 25.220.40 - Metallic coatings. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ISO 10309:1999 has the following relationships with other standards: It is inter standard links to SIST EN ISO 10309:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase SIST ISO 10309:1999 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-1999
Kovinske prevleke - Preskus ugotavljanja poroznosti – Preskus ferroxyl
Metallic coatings -- Porosity tests -- Ferroxyl test
Revêtements métalliques -- Essais de porosité -- Essai au ferroxyle
Ta slovenski standard je istoveten z: ISO 10309:1994
ICS:
25.220.40 Kovinske prevleke Metallic coatings
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

ISO
INTERNATIONAL
STANDARD
First edition
1994-12-01
Metallic coatings - Porosity tests -
Ferroxyl test
ßedtements mktalliques - Essais de porositk - Essai au ferroxyle
Reference number
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 10309 was prepared by Technical Committee
lSO/TC 107, MetaNc and other inorganic coatings, Subcommittee SC 7,
Corrosion tests.
0 ISO 1994
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronrc or mechanrcal, including photocopyrng and
microfilm, without Permission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-l 211 Geneve 20 0 Switzerland
Printed in Switzerland
ii
~~~~
INTERNATIONAL STANDARD 0 ISO ISO 10309:1994(E)
- Porosity tests - Ferroxyl test
Metallic coatings
tom of discontinuities in metallic coatings migrate to
1 Scope
treated test Paper held in contact with the coating
surface. The base metal ions retained on the treated
This International Standard specifies a method of re-
test Paper form a blue-coloured marking or spot when
vealing pores or other discontinuities, when testing
the treated Paper is subsequently immersed in a sol-
metallic coatings, that are not visibly affected by
ution of a ferricyanide indicator Solution.
ferricyanide and chloride ions during the test period
and that are cathodic to iron and steel. This method
is especially useful for thick, hard chromium coatings
4 Reagents and materials
used for wear resistance.
NOTE 1 With some coating materials a very thin layer is
4.1 Purity
dissolved by the sodium chloride Solution during a 10 min-
ute application period (see 5.2.3). The impact of such dis-
Solution is that potential porosity, i.e. pores that have been
All chemicals used shall be of a recognized analytical
covered over by very thin layers, are sometimes re-exposed.
reagent grade and the water used shall be distilled or
Experience has shown that such potential porosity is fre-
deionized having a conductivity not greater than
quently re-exposed during actual Service.
20 pS/cm (see ISO 3696).
4.2 Preparation of the indicator solution
2 Normative reference
4.2.1 Ssdium chloride reagent
The following Standard contains provisions which,
through reference in this text, constitute provisions
Dissolve 50 g of sodium chloride and 1 g of a non-
of this International Standard. At the time of publi-
ionic wetting agent in 1 litre of hot (90 “c> water.
cation, the edition indicated was valid. All Standards
Dissolve 50 g of gelatin or agar in the above men-
are subject to revision, and Parties to agreements
tioned hot sodium chloride Solution to provide gelling
based on this International Standard are encouraged
properties. The Solution will then gel upon cooling, but
to investigate the possibility of applying the most re-
tan be re-liquefied, for use, by heating it to 35 “C.
cent edition of the Standard indicated below. Mem-
bers of IEC and ISO main
...


ISO
INTERNATIONAL
STANDARD
First edition
1994-12-01
Metallic coatings - Porosity tests -
Ferroxyl test
ßedtements mktalliques - Essais de porositk - Essai au ferroxyle
Reference number
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 10309 was prepared by Technical Committee
lSO/TC 107, MetaNc and other inorganic coatings, Subcommittee SC 7,
Corrosion tests.
0 ISO 1994
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronrc or mechanrcal, including photocopyrng and
microfilm, without Permission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-l 211 Geneve 20 0 Switzerland
Printed in Switzerland
ii
~~~~
INTERNATIONAL STANDARD 0 ISO ISO 10309:1994(E)
- Porosity tests - Ferroxyl test
Metallic coatings
tom of discontinuities in metallic coatings migrate to
1 Scope
treated test Paper held in contact with the coating
surface. The base metal ions retained on the treated
This International Standard specifies a method of re-
test Paper form a blue-coloured marking or spot when
vealing pores or other discontinuities, when testing
the treated Paper is subsequently immersed in a sol-
metallic coatings, that are not visibly affected by
ution of a ferricyanide indicator Solution.
ferricyanide and chloride ions during the test period
and that are cathodic to iron and steel. This method
is especially useful for thick, hard chromium coatings
4 Reagents and materials
used for wear resistance.
NOTE 1 With some coating materials a very thin layer is
4.1 Purity
dissolved by the sodium chloride Solution during a 10 min-
ute application period (see 5.2.3). The impact of such dis-
Solution is that potential porosity, i.e. pores that have been
All chemicals used shall be of a recognized analytical
covered over by very thin layers, are sometimes re-exposed.
reagent grade and the water used shall be distilled or
Experience has shown that such potential porosity is fre-
deionized having a conductivity not greater than
quently re-exposed during actual Service.
20 pS/cm (see ISO 3696).
4.2 Preparation of the indicator solution
2 Normative reference
4.2.1 Ssdium chloride reagent
The following Standard contains provisions which,
through reference in this text, constitute provisions
Dissolve 50 g of sodium chloride and 1 g of a non-
of this International Standard. At the time of publi-
ionic wetting agent in 1 litre of hot (90 “c> water.
cation, the edition indicated was valid. All Standards
Dissolve 50 g of gelatin or agar in the above men-
are subject to revision, and Parties to agreements
tioned hot sodium chloride Solution to provide gelling
based on this International Standard are encouraged
properties. The Solution will then gel upon cooling, but
to investigate the possibility of applying the most re-
tan be re-liquefied, for use, by heating it to 35 “C.
cent edition of the Standard indicated below. Mem-
bers of IEC and ISO maintain registers of currently
NOTE 2 A variety of non-ionic wetting agents is com-
valid International Standards.
mercially available.
ISO 3696: 1987, Water for analytical laboratory use -
4.2.2 Ferricyanide reagent
Specification and test methods.
Dissolve 10 g of potassium hexacyanoferrate(III) (pot-
assium ferricyanide) in 1 litre of water. Measure the
pl-4 of the Solution. If it is outside the range 6 + 0,2
3 Principle
discard the Solution and the reagent and ob& a
purer grade of reagent.
Base metal ions
...


NORME
Iso
INTERNATIONALE
Premiére édition
1994-12-01
Revêtements métalliques - Essais de
porosité - Essai au ferroxyle
Metallic coa tings - Porosity tests - Ferroxyl test
Numéro de référence
KO 10309: 1994(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une
étude a le droit de faire partie du comité technique créé à cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques
sont soumis aux comités membres pour vote. Leur publication comme
Normes internationales requiert l’approbation de 75 % au moins des co-
mités membres votants.
La Norme internationale ISO 10309 a été élaborée par le comité technique
lSO/TC 107, Revêtements métalliques et autres revêtements
inorganiques, sous-comité SC 7, Essais de corrosion.
0 ISO 1994
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publi-
cation ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun pro-
cédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord
écrit de l’éditeur.
de normalisation
Organisation internationale
56@CH-1211 Genève 20 l Su isse
Case Postale
Imprimé en Suisse
ii
NORME INTERNATIONALE 0 ISO
Revêtements métalliques - Essais de porosité -
Essai au ferroxyle
3 Principe
1 Domaine d’application
Les ions du métal de base qui se sont formés dans
La présente Norme internationale prescrit une mé-
les piles de corrosion au fond des discontinuités des
thode pour la détection des pores ou de toute autre
revêtements métalliques migrent vers le papier indi-
discontinuité lors de l’essai des revêtements métalli-
cateur traité lorsque celui-ci est maintenu en contact
ques qui ne sont pas altérés de manière visible par les
avec la surface du revêtement. Les ions du métal de
ions ferricyanure et chlorure pendant la période d’es-
base retenus par le papier indicateur forment une ta-
sai et qui peuvent servir de cathode avec les produits
che ou une marque bleue après immersion du papier
sidérurgiques.
dans une solution préparée avec une solution indica-
La méthode est particulièrement utile dans le cas trice à I’hexacyanoferrate( I II).
d’épais revêtements durs de chrome à usages indus-
triels utilisés pour la résistance à l’usure.
4 Réactifs et matériaux
NOTE 1 Avec certains matériaux de revêtement, une très
4.1 Pureté
mince couche se dissout dans la solution de chlorure de
sodium pendant une durée d’application de 10 minutes (voir
5.2.3). Dans certains cas, cette mise en solution a pour effet Tous les produits chimiques utilisés doivent être de
de faire réapparaître a la surface les pores potentiels, c’est-
qualité analytique reconnue, et l’eau utilisée doit être
à-dire ceux qui ont été recouverts par de très minces cou-
distillée ou déionisée et avoir une conductivité infé-
ches. L’expérience a montre que ces pores réapparaissent
rieure ou égale à 20 pS/cm (voir ISO 3696).
fréquemment a la surface dans les conditions d’utilisation
réelle.
4.2 Préparation de la solution indicatrice
4.2.1 Réactif au chlorure de sodium
2 Référence normative
Mettre en solution 50 g de chlorure de sodium et
1 g d’agent mouillant non ionique dans 1 litre d’eau
La norme suivante contient des dispositions qui, par
chaude (90 “C). Mettre en solution 50 g de gélatine
suite de la référence qui en est faite, constituent des
ou de gélose dans la solution de chlorure de sodium
dispositions valables pour la présente Norme interna-
ainsi obtenue portée à chaud pour lui conférer un
tionale. Au moment de la publication, l’édition indi-
pouvoir gélifiant. La solution se gélifie lorsqu’elle se
quée était en vigueur. Toute norme est sujette à
refroidit, mais il est possible de la reliquéfier pour uti-
révision et les parties prenantes des accords fondés
lisation en la chauffant jusqu’à 35 “C.
sur la présente Norme internationale sont invitées à
rechercher la possibilité d’appliquer l’édition la plus NOTE 2 Plusieurs agents mouillants non ioniques sont
disponibles dans le commerce.
récente de la norme indiquée ci-après. Les membres
de la CEI et de I’ISO possèdent le registre des Nor-
4.2.2 Réactif au ferricyanure
mes internationales en vigueur à un moment donné.
Mettre en solution 10 g d’hexacyanoferrate(III) de po-
ISO 3696: 1987, Eau pour laboratoire à usage analyti-
tassium (ferricyanure de potassium) dans 1 litre d’eau.
- Spécifica tion et méthodes d’essai.
que
0 ISO
Mesurer le p
...


NORME
Iso
INTERNATIONALE
Premiére édition
1994-12-01
Revêtements métalliques - Essais de
porosité - Essai au ferroxyle
Metallic coa tings - Porosity tests - Ferroxyl test
Numéro de référence
KO 10309: 1994(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres de
I’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de I’ISO. Chaque comité membre intéressé par une
étude a le droit de faire partie du comité technique créé à cet effet. Les
organisations internationales, gouvernementales et non gouvernemen-
tales, en liaison avec I’ISO participent également aux travaux. L’ISO colla-
bore étroitement avec la Commission électrotechnique internationale (CEI)
en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques
sont soumis aux comités membres pour vote. Leur publication comme
Normes internationales requiert l’approbation de 75 % au moins des co-
mités membres votants.
La Norme internationale ISO 10309 a été élaborée par le comité technique
lSO/TC 107, Revêtements métalliques et autres revêtements
inorganiques, sous-comité SC 7, Essais de corrosion.
0 ISO 1994
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publi-
cation ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun pro-
cédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord
écrit de l’éditeur.
de normalisation
Organisation internationale
56@CH-1211 Genève 20 l Su isse
Case Postale
Imprimé en Suisse
ii
NORME INTERNATIONALE 0 ISO
Revêtements métalliques - Essais de porosité -
Essai au ferroxyle
3 Principe
1 Domaine d’application
Les ions du métal de base qui se sont formés dans
La présente Norme internationale prescrit une mé-
les piles de corrosion au fond des discontinuités des
thode pour la détection des pores ou de toute autre
revêtements métalliques migrent vers le papier indi-
discontinuité lors de l’essai des revêtements métalli-
cateur traité lorsque celui-ci est maintenu en contact
ques qui ne sont pas altérés de manière visible par les
avec la surface du revêtement. Les ions du métal de
ions ferricyanure et chlorure pendant la période d’es-
base retenus par le papier indicateur forment une ta-
sai et qui peuvent servir de cathode avec les produits
che ou une marque bleue après immersion du papier
sidérurgiques.
dans une solution préparée avec une solution indica-
La méthode est particulièrement utile dans le cas trice à I’hexacyanoferrate( I II).
d’épais revêtements durs de chrome à usages indus-
triels utilisés pour la résistance à l’usure.
4 Réactifs et matériaux
NOTE 1 Avec certains matériaux de revêtement, une très
4.1 Pureté
mince couche se dissout dans la solution de chlorure de
sodium pendant une durée d’application de 10 minutes (voir
5.2.3). Dans certains cas, cette mise en solution a pour effet Tous les produits chimiques utilisés doivent être de
de faire réapparaître a la surface les pores potentiels, c’est-
qualité analytique reconnue, et l’eau utilisée doit être
à-dire ceux qui ont été recouverts par de très minces cou-
distillée ou déionisée et avoir une conductivité infé-
ches. L’expérience a montre que ces pores réapparaissent
rieure ou égale à 20 pS/cm (voir ISO 3696).
fréquemment a la surface dans les conditions d’utilisation
réelle.
4.2 Préparation de la solution indicatrice
4.2.1 Réactif au chlorure de sodium
2 Référence normative
Mettre en solution 50 g de chlorure de sodium et
1 g d’agent mouillant non ionique dans 1 litre d’eau
La norme suivante contient des dispositions qui, par
chaude (90 “C). Mettre en solution 50 g de gélatine
suite de la référence qui en est faite, constituent des
ou de gélose dans la solution de chlorure de sodium
dispositions valables pour la présente Norme interna-
ainsi obtenue portée à chaud pour lui conférer un
tionale. Au moment de la publication, l’édition indi-
pouvoir gélifiant. La solution se gélifie lorsqu’elle se
quée était en vigueur. Toute norme est sujette à
refroidit, mais il est possible de la reliquéfier pour uti-
révision et les parties prenantes des accords fondés
lisation en la chauffant jusqu’à 35 “C.
sur la présente Norme internationale sont invitées à
rechercher la possibilité d’appliquer l’édition la plus NOTE 2 Plusieurs agents mouillants non ioniques sont
disponibles dans le commerce.
récente de la norme indiquée ci-après. Les membres
de la CEI et de I’ISO possèdent le registre des Nor-
4.2.2 Réactif au ferricyanure
mes internationales en vigueur à un moment donné.
Mettre en solution 10 g d’hexacyanoferrate(III) de po-
ISO 3696: 1987, Eau pour laboratoire à usage analyti-
tassium (ferricyanure de potassium) dans 1 litre d’eau.
- Spécifica tion et méthodes d’essai.
que
0 ISO
Mesurer le p
...

Questions, Comments and Discussion