SIST EN 60622:2003
(Main)Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells
Specifies tests and requirements for sealed nickel-cadmium prismatic rechargeable single cells.
Akkumulatoren und Batterien mit alkalischem oder anderen nichtsäurehaltigen Elektrolyten - Gasdichte wiederaufladbare prismatische Nickel-Cadmium-Einzelzellen
Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Eléments individuels parallélépipédiques rechargeables étanches au nickel-cadmium
Spécifie les essais et les prescriptions applicables aux éléments individuels parallélépipédiques rechargeables étanches au nickel-cadmium.
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells
General Information
Relations
Standards Content (Sample)
SIST EN 60622:2003SLOVENSKIapril 2003
STANDARDSecondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells©
Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 60622:2003(en)ICS29.220.30
EUROPEAN STANDARD
EN 60622 NORME EUROPÉENNE EUROPÄISCHE NORM
January 2003 CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60622:2003 E
ICS 29.220.30 Supersedes EN 60622:1995
English version
Secondary cells and batteries containing alkaline
or other non-acid electrolytes -
Sealed nickel-cadmium prismatic rechargeable single cells (IEC 60622:2002)
Accumulateurs alcalins et autres accumulateurs à électrolyte non acide - Eléments individuels parallélépipédiques rechargeables étanches au nickel-cadmium (CEI 60622:2002)
Akkumulatoren und Batterien mit alkalischem oder anderen nichtsäurehaltigen Elektrolyten - Gasdichte wiederaufladbare prismatische Nickel-Cadmium-Einzelzellen (IEC 60622:2002)
This European Standard was approved by CENELEC on 2002-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
EN 60622:2003 - 2 - Foreword The text of document 21A/362/FDIS, future edition 3 of IEC 60622, prepared by SC 21A, Secondary cells and batteries containing alkaline or other non-acid electrolytes, of IEC TC 21, Secondary cells and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60622 on 2002-12-01.
This European Standard supersedes EN 60622:1995.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2003-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2005-12-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. __________ Endorsement notice The text of the International Standard IEC 60622:2002 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61434 NOTE Harmonized as EN 61434:1996 (not modified). __________
- 3 - EN 60622:2003
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-486 - 1) International Electrotechnical Vocabulary (IEV) Chapter 486: Secondary cells and batteries
- - IEC 60051 Series Direct acting indicating analogue electrical measuring instruments and their accessories
EN 60051 Series IEC 60410 - 1) Sampling plans and procedures for inspection by attributes
- - IEC 60417 Series Graphical symbols for use on equipment EN 60417 Series IEC 60485 - 1) Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital converters
- - IEC 61438 - 1) Possible safety and health hazards in the use of alkaline secondary cells and batteries - Guide to equipment manufacturers and users
- -
1) Undated reference.
NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD60622Troisième éditionThird edition2002-10Accumulateurs alcalins et autres accumulateursà électrolyte non acide –Eléments individuels parallélépipédiquesrechargeables étanches au nickel-cadmiumSecondary cells and batteries containingalkaline or other non-acid electrolytes –Sealed nickel-cadmium prismaticrechargeable single cellsPour prix, voir catalogue en vigueurFor price, see current catalogue© IEC 2002
Droits de reproduction réservés
⎯
Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite niutilisée sous quelque forme que ce soit et par aucun procédé,électronique ou mécanique, y compris la photocopie et lesmicrofilms, sans l'accord écrit de l'éditeur.No part of this publication may be reproduced or utilized in anyform or by any means, electronic or mechanical, includingphotocopying and microfilm, without permission in writing fromthe publisher.International Electrotechnical Commission,
3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11
Telefax: +41 22 919 03 00
E-mail: inmail@iec.ch
Web: www.iec.chCODE PRIXPRICE CODENCommission Electrotechnique InternationaleInternational Electrotechnical Commission
60622 © IEC:2002– 3 –CONTENTSFOREWORD.51General.71.1Scope.71.2Normative references.71.3Terms and definitions.71.4Parameter measurement tolerances.92Designation and marking.92.1Cell designation.92.2Cell termination.112.3Marking.112.4Safety recommendations.113Dimensions.114Electrical tests.134.1Charging procedure for test purposes.154.2Discharge performance.154.2.1Discharge performance at 20 °C.154.2.2Discharge performance at +5 °C.154.2.3Discharge performance at –18 °C.174.2.4High rate current test.194.3Charge retention.194.4Endurance.194.4.1Endurance in cycles.194.4.2Permanent charge endurance.214.5Charge acceptance at constant voltage.214.6Overcharge.234.7Safety device operation.234.8Gas leakage test.234.9Storage.255Mechanical tests.256Physical appearance.257Conditions for approval and acceptance.257.1Type approval.257.2Batch acceptance.27Bibliography.29
60622 © IEC:2002– 5 –INTERNATIONAL ELECTROTECHNICAL COMMISSION___________SECONDARY CELLS AND BATTERIES CONTAINING ALKALINEOR OTHER NON-ACID ELECTROLYTES –SEALED NICKEL-CADMIUM PRISMATICRECHARGEABLE SINGLE CELLSFOREWORD1)The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprisingall national electrotechnical committees (IEC National Committees). The object of the IEC is to promoteinternational co-operation on all questions concerning standardization in the electrical and electronic fields. Tothis end and in addition to other activities, the IEC publishes International Standards. Their preparation isentrusted to technical committees; any IEC National Committee interested in the subject dealt with mayparticipate in this preparatory work. International, governmental and non-governmental organizations liaisingwith the IEC also participate in this preparation. The IEC collaborates closely with the InternationalOrganization for Standardization (ISO) in accordance with conditions determined by agreement between thetwo organizations.2)The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, aninternational consensus of opinion on the relevant subjects since each technical committee has representationfrom all interested National Committees.3)The documents produced have the form of recommendations for international use and are published in the formof standards, technical specifications, technical reports or guides and they are accepted by the NationalCommittees in that sense.4)
In order to promote international unification, IEC National Committees undertake to apply IEC InternationalStandards transparently to the maximum extent possible in their national and regional standards. Anydivergence between the IEC Standard and the corresponding national or regional standard shall be clearlyindicated in the latter.5)
The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for anyequipment declared to be in conformity with one of its standards.6)
Attention is drawn to the possibility that some of the elements of this International Standard may be the subjectof patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.International Standard IEC 60622 has been prepared by subcommittee 21A: Secondary cellsand batteries containing alkaline or other non-acid electrolytes, of IEC technical committee21: Secondary cells and batteries.This third edition cancels and replaces the second edition published in 1988, amendment 1(1989) and amendment 2 (1992). This third edition constitutes a technical revision.The text of this standard is based on the following documents:FDISReport on voting21A/362/FDIS21A/370/RVDFull information on the voting for the approval of this standard can be found in the report onvoting indicated in the above table.This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.The committee has decided that the contents of this publication will remain unchangeduntil 2008-01. At this date, the publication will be•reconfirmed;•withdrawn;•replaced by a revised edition, or•amended.
60622 © IEC:2002– 7 –SECONDARY CELLS AND BATTERIES CONTAINING ALKALINEOR OTHER NON-ACID ELECTROLYTES –SEALED NICKEL-CADMIUM PRISMATICRECHARGEABLE SINGLE CELLS1 General1.1 ScopeThis International standard specifies marking, tests and requirements for sealed nickel-cadmium prismatic secondary single cells.NOTE
In this context “prismatic” refers to cells having rectangular sides and bases.Where there exists an IEC standard specifying test conditions and requirements for cells usedin special applications and which is in conflict with this standard, the former takesprecedence.1.2 Normative referencesThe following referenced documents are indispensable for the application of this document.For dated references, only the edition cited applies. For undated references, the latest editionof the referenced document (including any amendments) applies.IEC 60050-486, International Electrotechnical Vocabulary – Chapter 486: Secondary cells andbatteries.IEC 60051 (all parts), Direct acting indicating analogue electrical measuring instruments andtheir accessoriesIEC 60410, Sampling plans and procedures for inspection by attributesIEC 60417 (all parts), Graphical symbols for use on equipment.IEC 60485, Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital convertersIEC 61438, Possible safety and health hazards in the use of alkaline secondary cells andbatteries – Guide to equipment manufacturers and users.1.3 Terms and definitionsFor the purpose of this International Standard, the definitions contained in IEC 60050-486 andthe following apply.1.3.1sealed cellcell which remains closed and does not release either gas or liquid when operated within thelimits of charge and temperature specified by the manufacturer. The cell is equipped with asafety device to prevent dangerously high internal pressure. The cell does not require additionto the electrolyte and is designed to operate during its life in its original sealed state
60622 © IEC:2002– 9 –1.3.2nominal voltagethe nominal voltage of a sealed nickel-cadmium rechargeable single cell is 1,2 V1.3.3rated capacityquantity of electricity C5 Ah (ampere-hours) declared by the manufacturer which a single cellcan deliver when discharged at the reference test current of 0,2 It A to a final voltage of 1,0 Vat +20 °C after charging, storing and discharging under the conditions specified in clause 41.4 Parameter measurement tolerancesThe overall accuracy of controlled or measured values, relative to the specified or actualvalues, shall be within these tolerances:a) ± 1 % for voltage;b) ± 1 %for current;c) ± 2 °Cfor temperature;d) ± 0,1 %for time;e) ± 1 %for capacity.These tolerances comprise the combined accuracy of the measuring instruments, themeasurement techniques used, and all other sources of error in the test procedure.For assistance in selecting inst
...
Questions, Comments and Discussion