Luminaire performance - Part 1: General Requirements (IEC 62722-1:2014)

This part of IEC 62722 covers specific performance and environmental requirements for
luminaires, incorporating electric light sources for operation from supply voltages up to
1 000 V. Unless otherwise detailed, performance data covered under the scope of this
standard are for the luminaires in a condition representative of new manufacture, with any
specified initial aging procedures completed.
IEC 62722-1 covers requirements for luminaires to support energy efficient use and
responsible environmental management to the end of life. The object of this Part 1 is to
provide a set of requirements which are considered to be generally applicable to most types
of luminaires. Where additional performance requirements for specific types of light source
are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series may also
cover a wider scope of performance aspects appropriate to the particular light source
technology.
NOTE The structure of these performance standards also allows for the possibility of Part 3 standards to be
introduced in the future should standardisation of performance criteria linked to specific luminaire applications be
determined as necessary (e.g. floodlighting, street lighting, etc.).
It is the intention that the requirements of this Part 1 are to be met by the provision of
information and data provided by the luminaire manufacturer (or responsible vendor).
Conformity is considered to be met by the provision of the requested information. Any
verification of data is to be conducted by the measurement requirements of this standard.
Semi-luminaires are not covered under the scope of this standard.
For some types of luminaire (e.g. decorative/household) the provision of performance data
under the scope of this standard may not be appropriate.

/

/

L'IEC 62722-1:2014 couvre les exigences de performance et d'environnement spécifiques relatives aux luminaires, incorporant des sources lumineuses électriques destinées à fonctionner avec des tensions d'alimentation allant jusqu'à 1 000 V. Sauf disposition contraire, les données de performance détaillées couvertes par le domaine d'application de la présente norme concernent les luminaires dans un état représentatif d'une nouvelle fabrication, tous les modes opératoires de vieillissement initial ayant été exécutés. Cette première édition annule et remplace l'IEC PAS 62722-1 parue en 2011 et constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'IEC PAS 62722-1.
a) L'inclusion d'exigences plus précises pour la comparaison de la forme de la distribution photométrique, avec la méthode de comparaison donnée dans l'Annexe D.
b) L'ajout d'autres normes régionales à l'inventaire donné dans l'Annexe A.

Tehnične lastnosti svetilk - 1. del: Splošne zahteve (IEC 62722-1:2014)

Ta del standarda IEC 62722 zajema posebne okoljske zahteve in zahteve glede zmogljivosti svetilk, ki vključujejo električne svetlobne vire v omrežnem napajanju do 1000 V. Razen če je drugače navedeno, veljajo podatki o delovanju, ki spadajo na področje uporabe tega standarda, za nove svetilke, pri katerih so bili opravljeni določeni začetni postopki staranja. Standard IEC 62722-1 zajema zahteve za svetilke, ki do konca življenjskega cikla podpirajo energijsko učinkovito uporabo in odgovorno ravnanje z okoljem. Cilj 1. dela je zagotavljanje nabora zahtev, ki se smatrajo kot splošno veljavne za večino vrst svetilk. Dodatne zahteve za delovanje, ki so morda ustrezne za posamezno vrsto svetlobnega vira, so določene v skupini standardov IEC 62722-2. Skupina standardov IEC 62722-2 lahko tudi zajema širši nabor vidikov v zvezi z delovanjem, ki so primerni za posamezno tehnologijo svetlobnih virov.
OPOMBA: Struktura teh standardov o delovanju omogoča, da se v prihodnosti vključi 3. del standardov, če bi se kriteriji delovanja, ki so povezani s posamezno uporabo svetilk, po potrebi standardizirali (npr. reflektorska osvetlitev, ulična razsvetljava itd.).
Namen je, da se zahteve 1. dela izpolni s pomočjo informacij in podatkov, ki jih zagotovi proizvajalec svetilk (ali odgovorni prodajalec).
Smatra se, da je za skladnost poskrbljeno, ko se zagotovijo zahtevane informacije. Vsakršno preverjanje podatkov je treba izvesti ob upoštevanju merilnih zahtev tega standarda. Ta standard ne zajema polsvetilk. Za nekatere vrste svetilk (npr. okrasne svetilke, svetilke v gospodinjstvu) zagotavljanje podatkov o delovanju v okviru tega standarda morda ni ustrezno.

General Information

Status
Published
Publication Date
03-Feb-2016
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
25-Jan-2016
Due Date
31-Mar-2016
Completion Date
04-Feb-2016

Relations

Buy Standard

Standard
EN 62722-1:2016
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 62722-1:2016
01-marec-2016
7HKQLþQHODVWQRVWLVYHWLONGHO6SORãQH]DKWHYH ,(&
Luminaire performance - Part 1: General Requirements (IEC 62722-1:2014)
/
/
Ta slovenski standard je istoveten z: EN 62722-1:2016
ICS:
29.140.40 Svetila Luminaires
SIST EN 62722-1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 62722-1:2016

---------------------- Page: 2 ----------------------

SIST EN 62722-1:2016


EUROPEAN STANDARD EN 62722-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
January 2016
ICS 29.140.40

English Version
Luminaire performance - Part 1: General requirements
(IEC 62722-1:2014 , modified)
Performance des luminaires - Arbeitsweise von Leuchten -
Partie 1: Exigences générales Teil 1: Allgemeine Anforderungen
(IEC 62722-1:2014 , modifiée) (IEC 62722-1:2014 , modifiziert)
This European Standard was approved by CENELEC on 2015-11-09. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 62722-1:2016 E

---------------------- Page: 3 ----------------------

SIST EN 62722-1:2016
EN 62722-1:2016
European foreword
The text of document 34D/1132/FDIS, future edition 1 of IEC 62722-1, prepared by SC 34D
"Luminaires" of IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC
parallel vote and approved by CENELEC as EN 62722-1:2016.
A draft amendment, which covers common modifications to IEC 62722-1:2014 (34D/1132/FDIS), was
prepared by CLC/TC 34Z "Luminaires and associated equipment" and approved by CENELEC.
The following dates are fixed:
(dop) 2016-11-09
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-11-09
• latest date by which the national standards conflicting with
the document have to be withdrawn

Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 62722-1:2014 are prefixed “Z”.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Regulation (EC) No. 245/2009, see informative Annex ZZ, which is an
integral part of this document.
2

---------------------- Page: 4 ----------------------

SIST EN 62722-1:2016
EN 62722-1:2016
Endorsement notice
The text of the International Standard IEC 62722-1:2014 was approved by CENELEC as a European
Standard with agreed common modifications.
COMMON MODIFICATIONS
Modification to Clause 1 Scope
Replace the last paragraph by the following:
“For some types of general purpose luminaires (e.g. decorative), the provision of all performance data
under the scope of this standard may not be appropriate.
For special purpose luminaires (e.g. emergency escape lighting), the provision of selected basic
performance data under the scope of this standard only could be appropriate (e. g. input power).”
Modification to Clause 2 Normative references
Add the following new reference:
EN 13032-2:2004, Light and lighting – Measurement and presentation of photometric data of lamps
and luminaires – Part 2: Presentation of data for indoor and outdoor work places
Modification to Clause 4 General requirements
Add the following after 4.6:
“4.Z1 Where a Commission Regulation specifies limits for parameters, these limits shall be used
instead of the limits specified in this standard.”
Modification to Clause 6 Photometric data
nd
Replace the 2 paragraph after Note 2 (before “The distribution of luminous intensity …”) by the
following:
“When a CEN flux code is provided, it shall be calculated in accordance with EN 13032-2.”
Modifications to annexes
Add the following at the end of Clause B.8:
“The power consumption when the operated lamps do not emit any light in normal operating
conditions is measured excluding the power consumed by sensors, network connections and other
auxiliary loads.”
Add the following new annexes.
3

---------------------- Page: 5 ----------------------

SIST EN 62722-1:2016
EN 62722-1:2016
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
- - Light and lighting - Measurement and EN 13032-2 2004
presentation of photometric data of lamps
and luminaires -
Part 2: Presentation of data for indoor and
outdoor work places
IEC 60598-1 -  Luminaires - EN 60598-1 -
Part 1: General requirements and tests
IEC 60598-2 series Luminaires - EN 60598-2 series
Part 2: Particular requirements
IEC 60598-2-22 -  Luminaires - EN 60598-2-22 -
Part 2-22: Particular requirements -
Luminaires for emergency lighting
IEC 62722-2 series Luminaire performance - EN 62722-2 series
Part 2: Particular requirements
CIE 34 1977 Road lighting lantern and installation data: - -
photometrics, classification and
performance
CIE 43 1979 Photometry of floodlights - -
CIE 121 1996 The photometry and goniophotometry of - -
luminaires
CIE 121 SPI 2009 The photometry and goniophotometry of - -
luminaires - supplement 1: luminaires for
emergency lighting

4

---------------------- Page: 6 ----------------------

SIST EN 62722-1:2016
EN 62722-1:2016
Annex ZZ
(informative)

Relationship between this European Standard and the ecodesign requirements
of Commission Regulation (EC) No 245/2009 aimed to be covered
This European standard has been prepared under a Commission’s standardisation request
M/495_Am3 to provide one voluntary means of conforming to the ecodesign requirements of
Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of
the European Parliament and of the Council with regard to ecodesign requirements for fluorescent
lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires
able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of
the Council [OJ L 76, 24.3.2009, p. 17–44].
Once this standard is cited in the Official Journal of the European Union under that Regulation,
compliance with the normative clauses of this standard given in Table ZZ.1 confers, within the limits of
the scope of this standard, a presumption of conformity with the corresponding ecodesign
requirements of that Regulation and associated EFTA Regulations.
Table ZZ.1 – Correspondence between this European Standard and Commission Regulation
(EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European
Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps
without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires
able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and
of the Council [OJ L 76, 24.3.2009, p. 17–44] and Commission’s standardisation request
M/495_Am3
Ecodesign requirements of Clause(s) / sub-clause(s) Remarks / Notes
Regulation No 245/2009 of this EN
[OJ L 76, 24.3.2009, p. 17–44]
Power consumption when the Clause 7 (rated standby power)
operated lamps do not emit any and Clause B.8
light in normal operating conditions
a
CEN flux code or photometric file Clause 6
(for Information on Best Available
Technology on the market)
Maintenance instructions to ensure 9.2
that the luminaire maintains, as far
as possible, its original quality
throughout its lifetime
Disassembly instructions. 9.3
a See Annex V "Indicative benchmarks for fluorescent and high intensity discharge products (for information)", item 4
"Luminaire product information".

WARNING 1: Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2: Other Union legislation may be applicable to the products falling within the scope of this
standard.
5

---------------------- Page: 7 ----------------------

SIST EN 62722-1:2016
EN 62722-1:2016
Modifications to Bibliography
Add the following note for the standard indicated:
IEC 61231 NOTE Harmonized as EN 61231.

Add the following new references
EN 13032-1:2004+A1:2012, Light and lighting – Measurement and presentation of photometric data of
lamps and luminaires – Part 1: Measurement and file format
EN 13032-3:2007, Light and lighting – Measurement and presentation of photometric data of lamps
and luminaires – Part 3: Presentation of data for emergency lighting of work places
EN 13201-3:2003, Road lighting – Part 3: Calculation of performance
EN 61341:2011, Method of measurement of centre beam intensity and beam angle(s) of reflector
lamps (IEC/TR 61341:2010)
EN 62504:2014, General lighting – Light emitting diode (LED) products and related equipment –
Terms and definitions (IEC 62504:2014)
6

---------------------- Page: 8 ----------------------

SIST EN 62722-1:2016




IEC 62722-1

®


Edition 1.0 2014-09




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Luminaire performance –

Part 1: General requirements




Performance des luminaires –

Partie 1: Exigences générales















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX R


ICS 29.140.40 ISBN 978-2-8322-1848-8



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 9 ----------------------

SIST EN 62722-1:2016
– 2 – IEC 62722-1:2014 © IEC 2014
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 General requirements . 8
5 Light sources and components of luminaires . 8
6 Photometric data . 8
7 Electrical data. 9
8 Luminaire efficacy data . 9
9 Environmental data . 10
9.1 Materials information . 10
9.2 Maintenance instructions . 10
9.3 Disassembly instructions . 10
Annex A (informative) Use of regional standards. 11
Annex B (normative) Measurement method of total power of luminaires and
associated powers . 12
B.1 General . 12
B.2 Test measurement of luminaire power during normal operation . 12
B.3 Standard test conditions . 12
B.4 Electrical measuring instruments . 12
B.5 Test luminaires . 12
B.6 Test voltage . 12
B.7 Luminaire power . 13
B.8 Luminaire standby power with lamps off . 13
B.9 Emergency lighting charging power . 13
Annex C (informative) Pictograms to assist the communication of instructions for
maintenance through life and end of life recycling . 14
C.1 General . 14
C.2 Instructions for luminaire servicing (see Figure C.1) . 14
C.3 Instructions for luminaire cleaning (see Figure C.2) . 14
C.4 Instructions for luminaire disposal (see Figure C.3) . 14
Annex D (normative) Photometric distribution data for luminaires . 15
D.1 General . 15
D.2 Measurement resolution of photometric distribution data . 15
D.3 Method of comparison and acceptable limits of variation . 15
Bibliography . 18


Figure C.1 – Instructions for luminaire servicing . 14
Figure C.2 – Instructions for luminaire cleaning . 14
Figure C.3 – Instructions for luminaire disposal . 14


Table D.1 – Some examples of nearest values to be selected for comparison . 16

---------------------- Page: 10 ----------------------

SIST EN 62722-1:2016
IEC 62722-1:2014 © IEC 2014 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

LUMINAIRE PERFORMANCE –

Part 1: General requirements

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62722-1 has been prepared by subcommittee 34D: Luminaires, of
IEC technical committee 34: Lamps and related equipment.
This first edition cancels and replaces IEC PAS 62722-1 published in 2011 and constitutes a
technical revision.
This edition includes the following significant technical changes with respect to
IEC PAS 62722-1.
a) The inclusion of more precise requirements for the comparison of the photometric
distribution shape, with the comparison method given in Annex D.
b) Further regional standards added to the schedule given in Annex A

---------------------- Page: 11 ----------------------

SIST EN 62722-1:2016
– 4 – IEC 62722-1:2014 © IEC 2014
The text of this standard is based on the following documents:
FDIS Report on voting
34D/1132/FDIS 34D/1141/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 62722 series, published under the general title Luminaire
performance can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 12 ----------------------

SIST EN 62722-1:2016
IEC 62722-1:2014 © IEC 2014 – 5 –
INTRODUCTION
The first edition of a performance standard for luminaires (general requirements)
acknowledges the need for defining performance data to be provided, the presentation of this
data, the basis of its measurement, and the associated tolerances that may be reasonably
expected. Information to support responsible environmental use is also included. Part 2 of the
IEC 62722-2 series will be introduced where additional performance requirements for specific
types of light source are required.
The provisions in this standard represent the technical knowledge of experts from the fields of
the luminaire industry and associated components such as lamps and controlgear.

---------------------- Page: 13 ----------------------

SIST EN 62722-1:2016
– 6 – IEC 62722-1:2014 © IEC 2014
LUMINAIRE PERFORMANCE –

Part 1: General requirements



1 Scope
This part of IEC 62722 covers specific performance and environmental requirements for
luminaires, incorporating electric light sources for operation from supply voltages up to
1 000 V. Unless otherwise detailed, performance data covered under the scope of this
standard are for the luminaires in a condition representative of new manufacture, with any
specified initial aging procedures completed.
IEC 62722-1 covers requirements for luminaires to support energy efficient use and
responsible environmental management to the end of life. The object of this Part 1 is to
provide a set of requirements which are considered to be generally applicable to most types
of luminaires. Where additional performance requirements for specific types of light source
are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series may also
cover a wider scope of performance aspects appropriate to the particular light source
technology.
NOTE The structure of these performance standards also allows for the possibility of Part 3 standards to be
introduced in the future should standardisation of performance criteria linked to specific luminaire applications be
determined as necessary (e.g. floodlighting, street lighting, etc.).
It is the intention that the requirements of this Part 1 are to be met by the provision of
information and data provided by the luminaire manufacturer (or responsible vendor).
Conformity is considered to be met by the provision of the requested information. Any
verification of data is to be conducted by the measurement requirements of this standard.
Semi-luminaires are not covered under the scope of this standard.
For some types of luminaire (e.g. decorative/household) the provision of performance data
under the scope of this standard may not be appropriate.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60598-1, Luminaires – Part 1: General requirements and tests
IEC 60598-2 (all parts), Luminaires – Part 2: Particular requirements
IEC 60598-2-22, Luminaires – Part 2-22: Particular requirements – Luminaires for emergency
lighting
IEC 62722-2 (all parts), Luminaire performance – Part 2: Particular requirements
CIE 34:1977, Road lighting lantern and installation data: Photometrics, classification and
performance
CIE 43:1979, Photometry of floodlights

---------------------- Page: 14 ----------------------

SIST EN 62722-1:2016
IEC 62722-1:2014 © IEC 2014 – 7 –
CIE 121:1996, The photometry and goniophotometry of luminaires
CIE 121-SP1:2009, The photometry and goniophotometry of luminaires – Supplement 1:
Luminaires for emergency lighting
NOTE Annex A provides details of regional standards the use of which are preferred in some countries.
3 Terms and definitions
For the purposes of this document, the terms and definitions given in the IEC 60598-1 as well
as the following apply.
3.1
input power
electrical power from the mains supply consumed by the luminaire including the operation of
all electrical components necessary for its intended functioning
3.2
standby power
electrical power from the mains supply consumed by the luminaire under normal operating
conditions, with the lamps switched off via a control signal
Note 1 to entry: Standby power is expressed in watts.
Note 2 to entry: For emergency lighting luminaires this does not include the emergency lighting charging power.
3.3
emergency lighting charging power
electrical power from the mains supply consumed by the charging circuit of emergency
luminaires to keep the battery charged
Note 1 to entry: Emergency lighting charging power is expressed in watts.
3.4
luminaire efficacy
ratio of the luminaires total luminous flux versus its input power at rated supply voltage,
excluding any emergency lighting charging power
Note 1 to entry: Luminaire efficacy is expressed in lumens per watt.
3.5
light output ratio
LOR
ratio of the total luminous flux of the luminaire, measured under specified practical conditions
with its own light sources and equipment, to the sum of the individual luminous fluxes of the
same light sources when operated outside the luminaire with the same equipment, under
specified conditions
Note 1 to entry: This note applies to the French language only.
3.6
rated value
quantitative value for a characteristic of a luminaire for specific operating conditions specified
in this standard, or in applicable standards, or assigned by the manufacturer or responsible
vendor
3.7
test voltage
voltage at which tests are carried out

---------------------- Page: 15 ----------------------

SIST EN 62722-1:2016
– 8 – IEC 62722-1:2014 © IEC 2014
3.8
BLF
ballast lumen factor
ratio of the luminous flux of the light source when the ballast under test is operated at its
rated voltage, to the luminous flux of the same lamp operated with the appropriate reference
ballast supplied at its rated voltage and frequency
4 General requirements
4.1 Luminaires shall be tested complete with the light source and controlgear specified by
the manufacturer. Except where otherwise specified, the luminaire, light source and
controlgear shall be tested as new, and installed as for normal use, having regard to the
manufacturer’s installation instructions.
4.2 Luminaires shall meet the requirements of the IEC 60598-2 series standards that are
appropriate to their design.
4.3 Luminaires shall meet all requirements of this Part 1 and where applicable also the
additional requirements of the IEC 62772-2 series appropriate to the type of light source used
by the luminaire. Where detailed in the IEC 62772-2 series, alternative methods of
measurement or limits to those given in this Part 1 may be specified.
4.4 Where it is specified by this standard that data is to be provided, this data may be
supplied by the manufacturer in printed or electronic formats, via the manufacturer’s
catalogues, website, or similar, unless otherwise specified by this standard.
4.5 Luminaires for tungsten filament lamps may be photometrically ra
...