SIST EN 16475-7:2016/kFprA1:2020
(Amendment)Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods
Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods
This European Standard specifies requirements and test methods for rain caps that are used as components, subject to flue gas, in order to prevent rain entry into the chimneys. Rain caps already tested together with system chimney products or other chimney components, e.g. terminals, are not covered by this standard. Rain caps incorporating a bird guard are also included. It also specifies the requirements for marking, manufacturers’ instruction, product information and evaluation of conformity.
Abgasanlagen - Zubehörteile - Teil 7: Regenhauben - Anforderungen und Prüfverfahren
Conduits de cheminée - Accessoires - Partie 7: Chapeaux pare-pluie - Exigences et méthodes d'essai
La présente Norme européenne spécifie les exigences et les méthodes d'essai pour les chapeaux pare-pluie utilisés comme composants, en contact avec les fumées, afin d'empêcher la pluie de pénétrer dans les conduits de fumée.
Les chapeaux pare-pluie déjà soumis à essai avec les composants de conduits système ou les autres composants du conduit de fumée, tels que les terminaux, ne sont pas couverts par la présente norme.
Les chapeaux pare-pluie qui n'ont pas la même ouverture sur tous les côtés ou qui n'ont pas au moins les mêmes forme et section sur les côtés opposés ne sont pas couverts par la présente Norme européenne.
Elle spécifie également les exigences pour le marquage, les instructions du fabricant, les informations sur le produit et l'évaluation de la conformité.
Dimovodne naprave - Oprema - 7. del: Dežne kape - Zahteve in preskusne metode
General Information
- Status
- Not Published
- Public Enquiry End Date
- 19-Dec-2018
- Technical Committee
- POZ - Požarna varnost
- Current Stage
- 98 - Abandoned project (Adopted Project)
- Start Date
- 24-Aug-2020
- Due Date
- 29-Aug-2020
- Completion Date
- 24-Aug-2020
Relations
- Consolidated By
SIST EN 16475-7:2016+A1:2020 - Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods - Effective Date
- 01-Oct-2020
- Amends
SIST EN 16475-7:2016 - Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods - Effective Date
- 01-Dec-2018
Overview
EN 16475-7:2016/FprA1 - "Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods" is a European Standard developed by CEN/TC 166. It specifies the requirements, test methods and conformity assessment for rain caps used on chimney flues to prevent rain entry. The standard covers rain caps (including those with integrated bird guards) as standalone chimney components, and sets rules for marking, manufacturer’s instructions, product information and evaluation of conformity (AVCP). Rain caps tested as integral parts of complete chimney systems or terminals are excluded. The draft amendment clarifies that rain caps with unequal openings or asymmetric cross-sections are not covered.
Key topics and technical requirements
- Scope and exclusions: Applies to standalone rain caps; excludes components already tested as part of a system chimney product or terminals; excludes asymmetrical designs per amendment.
- Performance characteristics:
- Reaction to fire: Manufacturers must declare reaction-to-fire class (Euroclasses A1–F). For plastic rain caps the standard references EN 14471 for classification and testing; reaction-to-fire classification is expressed in accordance with EN 13501-1.
- Flow resistance: Specifies how to determine the coefficient of flow resistance relevant to chimney performance (no numeric thresholds are given in the standard text extract).
- Testing and assessment methods: Defines required test methods and the role of notified laboratories in assessing essential characteristics (sampling, testing, calculation or descriptive documentation).
- Marking and documentation: Requirements for product marking, manufacturer’s instructions and product information to support safe installation and conformity.
- Conformity systems (AVCP): Assigns AVCP systems (System 1, 3, or 4 depending on reaction-to-fire regulation and intended use) in line with Regulation (EU) No. 305/2011 (CPR) Annex V.
Applications and who uses it
- Manufacturers of rain caps and chimney accessories - to design products that meet European performance and safety requirements and prepare documentation for CE marking.
- Test laboratories and notified bodies - to carry out required reaction-to-fire and flow-resistance testing and perform conformity assessment tasks.
- Specifiers, architects and HVAC installers - to select appropriate rain caps that meet regulatory requirements for reaction to fire and chimney performance.
- Certifiers and regulatory authorities - to verify compliance with CPR and national implementation of EN standards.
- Procurement teams and building owners - to ensure installed chimney accessories conform to safety and performance requirements.
Related standards
- EN 14471 - referenced for reaction-to-fire testing of plastic components
- EN 13501-1 - classification to Euroclasses (A1–F)
- Regulation (EU) No. 305/2011 (CPR) - for AVCP systems and CE marking
- Other parts of the EN 16475 series (Chimneys - Accessories) for additional accessory requirements
Keywords: EN 16475-7, rain caps, chimneys, requirements and test methods, reaction to fire, flow resistance, AVCP, CE marking, manufacturer’s instructions.
Frequently Asked Questions
SIST EN 16475-7:2016/kFprA1:2020 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods". This standard covers: This European Standard specifies requirements and test methods for rain caps that are used as components, subject to flue gas, in order to prevent rain entry into the chimneys. Rain caps already tested together with system chimney products or other chimney components, e.g. terminals, are not covered by this standard. Rain caps incorporating a bird guard are also included. It also specifies the requirements for marking, manufacturers’ instruction, product information and evaluation of conformity.
This European Standard specifies requirements and test methods for rain caps that are used as components, subject to flue gas, in order to prevent rain entry into the chimneys. Rain caps already tested together with system chimney products or other chimney components, e.g. terminals, are not covered by this standard. Rain caps incorporating a bird guard are also included. It also specifies the requirements for marking, manufacturers’ instruction, product information and evaluation of conformity.
SIST EN 16475-7:2016/kFprA1:2020 is classified under the following ICS (International Classification for Standards) categories: 91.060.40 - Chimneys, shafts, ducts. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 16475-7:2016/kFprA1:2020 has the following relationships with other standards: It is inter standard links to SIST EN 16475-7:2016+A1:2020, SIST EN 16475-7:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 16475-7:2016/kFprA1:2020 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/105. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase SIST EN 16475-7:2016/kFprA1:2020 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 16475-7:2016/oprA1:2018
01-december-2018
Dimovodne naprave - Oprema - 7. del: Dežne kape - Zahteve in preskusne metode
Chimneys - Accessories - Part 7: Rain caps - Requirements and test methods
Abgasanlagen - Zubehörteile - Teil 7: Regenhauben - Anforderungen und Prüfverfahren
Conduits de cheminée - Accessoires - Partie 7: Chapeaux pare-pluie - Exigences et
méthodes d'essai
Ta slovenski standard je istoveten z: EN 16475-7:2016/prA1
ICS:
91.060.40 Dimniki, jaški, kanali Chimneys, shafts, ducts
SIST EN 16475-7:2016/oprA1:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 16475-7:2016/oprA1:2018
SIST EN 16475-7:2016/oprA1:2018
DRAFT
EUROPEAN STANDARD
EN 16475-7:2016
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
October 2018
ICS 91.060.40
English Version
Chimneys - Accessories - Part 7: Rain caps - Requirements
and test methods
Conduits de cheminée - Accessoires - Partie 7: Abgasanlagen - Zubehörteile - Teil 7: Regenhauben -
Chapeaux pare-pluie - Exigences et méthodes d'essai Anforderungen und Prüfverfahren
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 166.
This draft amendment A1, if approved, will modify the European Standard EN 16475-7:2016. If this draft becomes an
amendment, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
inclusion of this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16475-7:2016/prA1:2018 E
worldwide for CEN national Members.
SIST EN 16475-7:2016/oprA1:2018
EN 16475-7:2016/prA1:2018 (E)
Contents Page
European foreword . 3
1 Modification to clause 1, Scope . 4
2 Modification to clause 4.4.1 . 4
3 Modification to Annex ZA.1 . 4
4 Modification to Clause ZA.2 . 5
5 Modification to Clause ZA.3 . 5
SIST EN 16475-7:2016/oprA1:2018
EN 16475-7:2016/prA1:2018 (E)
European foreword
This document (EN 16475-7:2016/prA1:2018) has been prepared by Technical Committee CEN/TC 166
“Chimneys”, the secretariat of which is held by ASI.
This document is a working document.
...