Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,50 m2K/W or a declared thermal conductivity greater than 0,065 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14305).

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Schaumglas (CG) - Spezifikation

Diese Europäische Norm legt die Anforderungen an werkmäßig hergestellte Produkte aus Schaumglas mit oder ohne Kaschierung oder Beschichtung fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in Form von Platten hergestellt.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Platten angewendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als 0,50 m2K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,065 W/(mK) bei 10 °C ist.
Die vorliegende Norm gilt weder für in situ Dämmprodukte noch für Produkte, die zur Dämmung von haustechnischen und betriebstechnischen Anlagen (durch EN  14305 abgedeckt) vorgesehen sind.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en verre cellulaire (CG) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en verre cellulaire (CG), avec ou sans parements ou enduits de finition, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux ou plaques.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou les normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,50 m2.K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,065 W/(m.K) ne relèvent pas du domaine d'application de la présente norme.
Les produits isolants mis en oeuvre in situ et les produits destinés à être utilisés pour l'isolation des équipements du bâtiment et des installations industrielles ne relèvent pas du domaine d'application de la présente norme (couverts par l’EN 14305).

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz penjenega stekla (CG) - Specifikacija

Ta evropski standard določa zahteve za površinsko obdelane ali lakirane ali površinsko neobdelane ali nelakirane proizvode iz penjenega stekla (CG), ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani v obliki plošč ali blokov.
Proizvodi iz tega standarda se uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane.
Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje.
Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom.
Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,50 m2K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,065 W/(mK) pri 10 °C, v tem standardu niso zajeti.
Ta standard ne zajema toplotnoizolacijskih proizvodov, izdelanih na kraju samem, ter proizvodov za izolacijo gradbene opreme in industrijskih napeljav (zajema jih standard EN 14305).

General Information

Status
Published
Publication Date
18-Mar-2015
Technical Committee
TOP - Thermal insulation
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Feb-2015
Due Date
04-May-2015
Completion Date
19-Mar-2015

Relations

Effective Date
01-Apr-2015
Effective Date
18-Jan-2023
Effective Date
01-Apr-2015
Effective Date
06-Sep-2017

Overview

EN 13167:2012+A1:2015 - Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification - is a European Standard published by CEN that defines product requirements, test methods and conformity assessment for factory-made cellular glass (CG) thermal insulation in the form of boards or slabs. It covers products with or without facings or coatings used for building thermal insulation and for incorporation into prefabricated insulation systems and composite panels. The standard also includes provisions for testing, marking, labelling and AVCP/CE marking (see Annex ZA). It does not set application-specific performance levels and excludes in situ insulation and insulation for building equipment/industrial installations (see EN 14305).

Key topics and requirements

  • Scope & exclusions: factory-made cellular glass (CG) boards/slabs; products with declared thermal resistance < 0.50 m2·K/W or declared thermal conductivity > 0.065 W/(m·K) at 10 °C are excluded.
  • Product characteristics: dimensional tolerances (length, width, thickness, squareness, flatness), mechanical properties (compressive strength, bending, point-load behaviour), water uptake, vapor resistance, organic content and thermal performance.
  • Thermal testing: guarded hot plate and heat flow meter methods for thermal resistance/thermal conductivity (EN 12667, EN 12939); Annex A on declared thermal values.
  • Durability & stability: tests for dimensional stability, compressive creep, short- and long-term water absorption.
  • Reaction to fire: links to reaction-to-fire test standards (EN 13501-1, EN 13823, EN ISO 11925-2, EN ISO 1182) and installation instructions (EN 15715).
  • Conformity & AVCP: procedures for Assessment and Verification of Constancy of Performance (AVCP), factory production control (FPC) and CE marking requirements (Annex ZA and Clause 7).
  • Annexes: normative guidance for thermal property declaration, product type determination, multi-layered CG products, and guidance on additional properties and specimen preparation.

Applications and who uses it

  • Typical applications: building envelope insulation (roofs, floors, walls), prefabricated thermal insulation systems, composite panels where CG boards/slabs are used as factory-made components.
  • Primary users:
    • Manufacturers of cellular glass insulation for product specification, factory production control and CE marking.
    • Testing laboratories for compliance testing (thermal, mechanical, water, fire).
    • Architects, specifiers and contractors selecting CG insulation for building projects.
    • Certification bodies and regulators assessing conformity under the Construction Products Regulation (CPR).

Related standards

  • EN 14305 (in situ/industrial insulation - excluded scope)
  • EN 12667 / EN 12939 (thermal testing methods)
  • EN 13501-1, EN 13823, EN ISO 11925-2 (reaction to fire)
  • EN 15715 (mounting/fixing instructions for fire testing)
  • Other EN 1316x series for factory-made insulation: EN 13162, EN 13163, EN 13164, EN 13165, EN 13166, EN 13168, EN 13169, EN 13170, EN 13171

Keywords: EN 13167, cellular glass, CG products, factory made, thermal insulation, boards, slabs, thermal conductivity, CE marking, AVCP, test methods.

Standard

SIST EN 13167:2013+A1:2015

English language
47 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 13167:2013+A1:2015 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification". This standard covers: This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,50 m2K/W or a declared thermal conductivity greater than 0,065 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14305).

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,50 m2K/W or a declared thermal conductivity greater than 0,065 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14305).

SIST EN 13167:2013+A1:2015 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 13167:2013+A1:2015 has the following relationships with other standards: It is inter standard links to SIST EN 13167:2013, SIST EN 13167:2013, SIST EN 13167:2013/kFprA1:2014, SIST EN 13167:2013+A1:2015/oprA2:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 13167:2013+A1:2015 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/103. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 13167:2013+A1:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz penjenega stekla (CG) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Schaumglas (CG) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en verre cellulaire (CG) - SpécificationThermal insulation products for buildings - Factory made cellular glass (CG) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13167:2012+A1:2015SIST EN 13167:2013+A1:2015en,fr,de01-april-2015SIST EN 13167:2013+A1:2015SLOVENSKI
STANDARDSIST EN 13167:20131DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13167:2012+A1
February 2015 ICS 91.100.60 Supersedes EN 13167:2012English Version
Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en verre cellulaire (CG) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Schaumglas (CG) - Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13167:2012+A1:2015 ESIST EN 13167:2013+A1:2015

Determination of the declared values of thermal resistance and
thermal conductivity . 23 Annex B (normative)
!Product type determination" (!PTD") and factory production control (FPC) . 25 Annex C (normative)
CG multi-layered insulation products . 29 Annex D (informative)
Additional properties . 31 Annex E (informative)
Preparation of the test specimens to measure thermal conductivity . 34 Annex ZA (informative)
!Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation" . 36 Bibliography . 47
Tables Table 1 — Dimensional stability under specified conditions . 13 Table 2 — Levels for compressive strength . 14 Table 3 — Levels for bending strength . 15 Table 4 — Levels for deformation under point load . 15 Table 5 — Test methods, test specimens and conditions. 18 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 24 Table B.1 — Minimum number of tests for !PTD" and minimum product testing frequencies . 25 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 27 Table D.1 — Test methods, test specimens, conditions and minimum testing frequencies . 32 Table ZA.1 — Relevant clauses for factory made cellular glass and intended use . 36 Table ZA.2 — Systems of AVCP . 38 Table ZA.3.1 — Assignment of AVCP tasks for factory made cellular glass products under system 1 for reaction to fire and system 3 (see Table ZA.2) . 38 Table ZA.3.2 — Assignment of AVCP tasks for factory made cellular glass products under system 3 (see Table ZA.2) . 40 SIST EN 13167:2013+A1:2015

Figures Figure ZA.1 — Example CE marking information of products under AVCP system 1 and system 3 . 46
is the thermal conductivity W/(m„K) 90/90 is a 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m„K) D is the declared thermal conductivity W/(m„K) i is one test result of thermal conductivity W/(m„K) mean is the mean thermal conductivity W/(m„K) U Is the design thermal conductivity W/(m„K)
is the water vapour diffusion resistance factor – N is the number of test results – Pd is the deformation under point load mm R90/90 is a 90 % fractile with a confidence level of 90 % for the thermal resistance m2„K/W RD is the declared thermal resistance m2„K/W Ri is one test result of thermal resistance m2„K/W Rmean is the mean thermal resistance m2„K/W RU is the design thermal resistance m2„K/W Sb is the deviation from squareness of the edge on length and width mm/m Sd is the deviation from squareness of the edge on thickness mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2„K/W s is the estimate of the standard deviation of the thermal conductivity W/(m„K) 1b is the bending strength kPa 1c is the compressive stress kPa SIST EN 13167:2013+A1:2015

AP is the symbol of the declared level of practical sound absorption coefficient AW is the symbol of the declared level of weighted sound absorption coefficient BS Is the symbol of the declared level for bending strength CC(i1/i2/y) 1c is the symbol of the declared level for compressive creep CS(Y) is the symbol of the declared level for compressive strength DS(N) is the symbol of the declared value for dimensional stability in normal condition DS(70,-) is the symbol of the declared value for dimensional stability at specified temperature DS(23,90) or
DS (70,90) is the symbol of the declared value for dimensional stability under specified temperature and relative humidity conditions MU is the symbol of the declared value for water vapour diffusion resistance factor PL(P) is the symbol of the declared level for penetration under point load TR is the symbol of the declared level for tensile strength perpendicular to faces WL(P) is the symbol of the declared level for long term water absorption by partial immersion WS is the symbol of the declared level for short term water absorption Z is the symbol of the declared value for water vapour resistance Abbreviated terms used in this standard: CG is Cellular Glass !PTD is Product Type Determination (previously named ITT for Initial Type Test)" FPC is Factory Production Control RtF is Reaction to Fire !AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of conformity) DoP is Declaration of Performance ThIB is Thermal Insulation for Buildings VCP is Verification of Constancy of Performance (previously named evaluation of conformity)" SIST EN 13167:2013+A1:2015

U and RU (design values) may be determined with reference to EN ISO 10456. SIST EN 13167:2013+A1:2015

± 2 mm for length and width — Faced board:
± 5 mm for length
± 2 mm for width 4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823. The load shall be 250 Pa. No test result shall deviate from the nominal thickness, dN, by more than ±2 mm. 4.2.4 Squareness Squareness shall be determined in accordance with EN 824. The deviation from squareness on length and width, Sb, of boards and slabs shall not exceed 5 mm/m. The deviation from squareness on thickness, Sd, shall not exceed 2 mm. 4.2.5 Flatness Flatness shall be determined in accordance with EN 825. The deviation from flatness, Smax, of boards and slabs, shall not exceed 2 mm. 4.2.6 Reaction to fire of the product as placed on the market Reaction to fire classification of the product, as placed on the market, shall be determined in accordance with EN 13501-1 and the mounting and fixing rules given in EN 15715. NOTE 1 This classification is compulsory and always included in the CE Marking label. Detailed information about the test conditions and the field of application of the classification as stated in the reaction to fire classification report shall be given in the manufacturer's literature. Manufacturers declaring Euroclass A1 without further test shall demonstrate by testing in accordance with
EN 13820 that the products do not contain more than 1,0 % by weight of organic matter. NOTE 2 The commission decision 96/603/EC of 4 October 1996 amended by the commission Decision 2000/605/EC of 26 September 2000 and 2003/424/EG of 6 June 2003 gives the list of products to be considered as reaction to fire class Euroclass A1 without the need for testing. 4.2.7 Durability characteristics 4.2.7.1 General The appropriate durability characteristics have been considered and are covered in 4.2.7.2 and 4.2.7.3 and where appropriate in 4.3.8 on compressive creep. 4.2.7.2 Durability of reaction to fire of the product as placed on the market against ageing/ degradation The reaction to fire performance of CG products as declared by 4.2.6 does not change with time. SIST EN 13167:2013+A1:2015

shall be less than 40 000. No test result of Z shall be less than the declared value. Alternatively, for the declaration of the water vapour diffusion resistance, , of cellular glass products, either unfaced or faced, the value quoted in EN ISO 10456, , =~ infinite (∞), may be used. Within the design and the installation of the material in the works, special attention shall be given to respect the required vapour resistance of the building component. SIST EN 13167:2013+A1:2015

EN 15715:2009 SIST EN 13167:2013+A1:2015

4 Method B 4.3.5 Point load EN 12430 Full size 1 Annex A 4.3.6 Tensile strength parallel to faces EN 1608 500 × 250 5 – 4.3.7 Tensile strength perpendicular to faces EN 1607 150 × 150 3 – 4.3.8 Compressive creep EN 1606 200 × 200 3 Test specimen: see
EN 826:1996, Annex A with use of reference points on the edge 4.3.9 Short term water absorption EN 1609 200 × 200 4 Method A Long term water absorption EN 12087 200 × 200 4 Method 1A 4.3.10 Water vapour transmission EN 12086 See 6.1 in EN 12086:1997 5 Set A – test conditions shall be chosen 4.3.11 Sound absorption EN ISO 354 Minimum 10 m2 1 To be reported 4.3.12 Release of dangerous substances b – – – 4.3.13 Reaction to fire of the product in standardized assemblies simulating end-use applications See EN 13501-1 and EN 15715 See Clause 6 of
EN 15715:2009 4.3.14 Continuous glowing combustion b – – – a Full-size product thickness except for 4.2.6 when the limits of test methods are exceeded. If for 4.3.3 and 4.3.8 the thickness of the test specimen is greater than the width, the length and the width shall be at least equal to the thickness of the test specimen. b Not yet available. 6 Designation code A designation code for the product shall be given by the manufacturer. The following shall be included except when there is no requirement for a property described in 4.3. — The cellular glass abbreviated term CG — This document number EN 13167 — Dimensional stability at specified temperature DS(70) — Dimensional stability under specified temperature and humidity conditions DS(23,90) or DS(70,90) — Compressive strength CS(Y)i SIST EN 13167:2013+A1:2015

Where “i” shall be used to indicate the relevant class or level or the declared value and for compressive creep the term “1c” shall be used to indicate the compressive stress, “y” shall indicate the number of years. The designation code for a cellular glass product is illustrated by the following example: EXAMPLE CG — EN 13167 —DS(70,90) — CS(Y)700 — PL(P) 1 – BS400 — TR100 — WS – WL(P) - MU NOTE The characteristics determined in 4.2 are not included in the designation code if a limit value (threshold value) is given for the product. ! 7 Assessment and Verification of the Constancy of Performance (AVCP) 7.1 General The manufacturer or his authorized representative shall be responsible for the conformity of his product with the requirements of this European Standard. The Assessment and Verification of Constancy of Performance (AVCP) shall be carried out in accordance with EN 13172 and shall be based on Product Type Determination (PTD), Factory Production Control (FPC) by the manufacturer, including product assessment and tests on samples taken at the factory. The compliance of the product with the requirements of this standard and with the stated values (including classes) shall be demonstrated by: — Product Type Determination (PTD), — Factory Production Control (FPC) by the manufacturer, including product assessment. If a manufacturer decides to group his products, it shall be done in accordance with EN 13172. 7.2 Product Type Determination (PTD) All characteristics defined in 4.2 and those in 4.3 if declared, shall be subject to Product Type Determination (PTD) in accordance with Annex B. For the relevant characteristics, PTD on products corresponding also to EN 14305 may be used for the purpose of PTD and Declaration of Performance (DoP) according to this standard. SIST EN 13167:2013+A1:2015
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...