Abstract

This document specifies a method for the measurement of flame spread times of vertically oriented textile fabrics and industrial products in the form of single or multi-component textile fabrics (coated, quilted, multilayered, sandwich combinations, and similar combinations) when subjected to a small, defined flame.

Status
Published
Public Enquiry End Date
30-Jul-2025
Publication Date
18-Jun-2026
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
10-Jun-2026
Due Date
15-Aug-2026
Completion Date
19-Jun-2026

Buy Documents

Standard

SIST EN ISO 6941:2026

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN ISO 6941:2026 is the Slovenian national standard identical to EN ISO 6941:2026, which adopts ISO 6941:2026. It specifies a laboratory method for measuring flame spread time on vertically oriented textile fabrics and textile-based industrial products when they are exposed to a small, defined flame. It is used by laboratories, manufacturers, and buyers who need comparable burn-behaviour data for fabrics, assemblies, and finished textile products.

What does SIST EN ISO 6941:2026 specify?

SIST EN ISO 6941:2026 specifies a test method for vertically oriented textile fabrics and industrial products made from single or multi-component textile fabrics, including coated, quilted, multilayered, sandwich combinations, and similar assemblies. The method measures how long a flame front takes to travel between marked positions after a small flame is applied under controlled conditions.

The introduction notes that the method assesses response to flame contact in a controlled laboratory setting and warns that the results may not represent situations with restricted air supply or exposure to large, intense heat sources. It also notes that seams and trimmings can be tested as part of the assembly in which they are used.

The document is organized into clauses 1 to 12, with two annexes:

AnnexWhat it covers
Annex ANormative description and construction of the burner
Annex BInformative experimental techniques and practical guidance

What are the key requirements of SIST EN ISO 6941:2026?

  • Clause 4, Principle - SIST EN ISO 6941:2026 applies a defined flame from a specified burner for 10 s to either the surface or the bottom edge of a vertically oriented specimen, then records the times for the flame front to sever marker threads at three positions. In practice, this gives a repeatable way to compare how fast flame spreads across a fabric.

  • Clause 5 and Annex A, Apparatus - SIST EN ISO 6941:2026 requires a mounting frame, a burner that can move from standby to operating position, a rectangular specimen holder with pins, a template for marking specimen locations, suitable gas, three timing devices, and white mercerized cotton marker threads. In practice, the accuracy of the result depends heavily on using the specified hardware and setting it up correctly.

  • Clause 6, Precautions - SIST EN ISO 6941:2026 requires equipment materials that are not harmed by corrosive combustion products, enough surrounding air volume to avoid oxygen depletion, and ventilation to clear smoke and fumes between tests. In practice, this protects both the test result and the operator, especially in enclosed or open-fronted test enclosures.

  • Clauses 7 and 8, Sampling and atmosphere - SIST EN ISO 6941:2026 calls for six test specimens, with specimen orientation marked by length direction and width direction, and an extra specimen for setup. Specimens are conditioned for at least 24 h at 20 °C and 65 % relative humidity unless otherwise specified, then tested within 2 min of removal; testing is carried out at 10 °C to 30 °C, 35 % to 65 % relative humidity, and air movement below 0.2 m/s. In practice, this keeps moisture and airflow from distorting the burn behaviour.

  • Clause 9, Setting up the apparatus - SIST EN ISO 6941:2026 defines two setup routes: Procedure A for surface ignition and Procedure B for bottom edge ignition. Procedure A uses a horizontal flame reach adjustment, while Procedure B uses a vertical flame height adjustment and an inclined burner position. In practice, the choice of procedure affects how the flame meets the specimen, so the setup must match the intended test mode.

  • Clause 10, Test procedure - SIST EN ISO 6941:2026 requires six fresh specimens for each test set, with the marker threads attached before ignition and the exposure surface and orientation recorded. The test flame is applied for 10 s or for the ignition time determined in ISO 6940 testing, and the times to sever the lower, middle, and upper marker threads are recorded for each specimen. In practice, the upper thread time is the most useful comparison point when ranking materials.

  • Clause 11 and Clause 12, Precision and report - SIST EN ISO 6941:2026 notes that repeatability depends strongly on material type, with knitted fabrics and shrinking fabrics needing careful mounting, and it recommends reporting sagging problems. The test report must identify the standard, gas used, date, ambient conditions, specimen attachment method, specimen identification and pre-treatment, exposure surface, ignition mode, ignition time, individual severance times, deviations, and unusual observations. In practice, this makes the result traceable and easier to compare across laboratories.

What terms does SIST EN ISO 6941:2026 define?

  • Flame application time - the period for which the ignition flame is applied to the test specimen.

  • Flame spread time - the time taken for a flame on a burning material to travel a specified distance under specified test conditions.

  • Surface ignition - the test setup in which the burner flame is applied to the surface of the vertically mounted specimen.

  • Bottom edge ignition - the test setup in which the burner flame is applied from below to the bottom edge of the vertically mounted specimen.

  • Marker threads - the cotton thread loops placed at three positions beside the specimen so the operator can measure when the flame front reaches each point.

  • Critical ignition time - the ignition time determined in ISO 6940 testing and used instead of the default 10 s exposure when that value is selected.

Who uses SIST EN ISO 6941:2026?

SIST EN ISO 6941:2026 is used by textile test laboratories, quality control teams, and product development engineers who need a controlled measure of flame spread on fabrics and textile assemblies. It is also relevant to manufacturers of coated, quilted, multilayered, and sandwich textile products, because the method can be applied to complete assemblies rather than only to simple fabrics.

Buyers, specifiers, and conformity assessment teams use the document when they need a comparable laboratory result for burn behaviour. It is especially useful when seams, trimmings, or different fabric directions need to be evaluated as part of the finished textile construction.

What changed in SIST EN ISO 6941:2026 from the previous edition?

SIST EN ISO 6941:2026 supersedes EN ISO 6941:2003 and replaces the second edition of ISO 6941. The changes stated in the document are:

  • Figure 1 b) was corrected, including the angular dimension line and the shape of the gas jet tip.
  • Figure 3 a) and Figure 3 b) were revised to show the test specimen more clearly.
  • The revision is described as clarifying the document without structural changes.

Which standards are used with SIST EN ISO 6941:2026?

  • ISO 4880, Burning behaviour of textiles and textile products - Vocabulary - provides the vocabulary and definitions used by the document.

  • ISO 6940, Textile fabrics - Burning behaviour - Determination of ease of ignition of vertically oriented specimens - provides the related ignition method and the critical ignition time referenced in the procedure.

  • ISO 2768-1, General tolerances - Part 1: Tolerances for linear and angular dimensions without individual tolerance indications - is cited in the figure notes for dimensional tolerances on the apparatus drawings.

What does the SIST EN ISO 6941:2026 document contain?

SIST EN ISO 6941:2026 contains the scope, normative references, terms and definitions, principle, apparatus requirements, precautions, sampling rules, conditioning and test atmosphere, setup instructions, the two test procedures, precision guidance, and the reporting requirements. The technical heart of the document is the pair of procedures for surface ignition and bottom edge ignition, which are supported by detailed apparatus and setup instructions.

The document also includes figures for the burner, the specimen holder, and the burner positions and flame adjustments used in both procedures. Annex A describes the burner construction in detail, while Annex B gives practical experimental techniques such as handling, safety, mounting, and specimen behaviour during testing.

Relations

Effective Date
09-Sep-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
27-May-2026
Effective Date
25-Sep-2024

Buy Documents

Standard

SIST EN ISO 6941:2026

English language (21 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Control Union Certifications

Global certification for agriculture and sustainability.

RVA Netherlands Verified

Hohenstein Institut

Textile testing and certification.

DAKKS Germany Verified

Bureau Veritas Bangladesh

Bureau Veritas certification services in Bangladesh.

BAB Bangladesh Verified

Sponsored listings

Frequently Asked Questions

SIST EN ISO 6941:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Textile fabrics - Burning behaviour - Measurement of flame spread properties of vertically oriented specimens (ISO 6941:2026)". This standard covers: This document specifies a method for the measurement of flame spread times of vertically oriented textile fabrics and industrial products in the form of single or multi-component textile fabrics (coated, quilted, multilayered, sandwich combinations, and similar combinations) when subjected to a small, defined flame.

This document specifies a method for the measurement of flame spread times of vertically oriented textile fabrics and industrial products in the form of single or multi-component textile fabrics (coated, quilted, multilayered, sandwich combinations, and similar combinations) when subjected to a small, defined flame.

SIST EN ISO 6941:2026 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 59.080.30 - Textile fabrics. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN ISO 6941:2026 has the following relationships with other standards: It is inter standard links to SIST ISO 4880:1999, SIST EN 13209-2:2006, SIST EN 13274-4:2020, SIST EN 12941:1999, SIST EN 1827:1999+A1:2009, SIST EN 12942:1999, SIST EN 13772:2011, SIST EN 407:2004, SIST EN 14931:2006, SIST EN ISO 6941:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN ISO 6941:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 flame application time
  • 3.2 flame spread time
  • 4 Principle
  • 5 Apparatus
  • 5.6 Timing device
  • 6 Precautions
  • 6.1 Construction of testing equipment
  • 6.2 Location of test apparatus
  • 6.3 Health and safety of operators
  • 7 Sampling
  • 7.1 Number of test specimens
  • 7.2 Test specimen holder pin location marks
  • 7.3 Test specimen size
  • 8 Conditioning and testing atmosphere
  • 8.1 Conditioning
  • 8.2 Testing atmosphere
  • 9 Setting up the apparatus
  • 9.1 Procedures A (Surface ignition)
  • 9.2 Procedure B (Bottom edge ignition)
  • 10 Test procedure
  • 10.1 Surface ignition
  • 10.2 Bottom edge ignition
  • 11 Precision
  • 12 Test report
  • Annex A
  • Annex B
  • Bibliography

Introduction

This method is one of two closely related methods of test for the inflammability of textile. This method [1] determines the “flame spread time” as defined in ISO 4880 . The other method observes and measures [2] “ease of ignition” (seeISO 6940 ).

The method given in this document assesses the properties of textile fabrics in response to flame contact under controlled conditions. There is a possibility that results do not apply the situations where there is restricted air supply or exposure to large sources of intense heat. The influence of seams on the behaviour of textile fabrics can be determined by this method, the seam being positioned within the test specimen so as to be subjected to the test flame. Whenever practicable, trimmings are tested as part of the textile fabric assembly on which they are or will be used.

SIST EN ISO 6941:2026

SIST EN ISO 6941:2026 International Standard ISO 6941:2026(en) Textile fabrics — Burning behaviour — Measurement of flame spread properties of vertically oriented specimens

1 Scope

This document specifies a method for the measurement of flame spread times of vertically oriented textile fabrics and industrial products in the form of single or multi-component textile fabrics (coated, quilted, multilayered, sandwich combinations, and similar combinations) when subjected to a small, defined flame.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4880, Burning behaviour of textiles and textile products — Vocabulary ISO 6940, Textile fabrics — Burning behaviour — Determination of ease of ignition of vertically oriented specimens

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 4880 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 flame application time

time for which the ignition flame is applied to the test specimen

3.2 flame spread time

time taken by a flame on a burning material to travel a specified distance under specified test conditions

4 Principle

A defined flame from a specified burner is applied for 10 s to the surface or the bottom edge of test specimens which are vertically oriented. The flame spread times in seconds for the flame front to travel between marker threads positioned adjacent to the surface of the test specimen and located at three distances from the igniting flame, are recorded.

SIST EN ISO 6941:2026 ISO 6941:2026(en)

5 Apparatus

5.1 Mounting frame, constructed to a design capable of holding the gas burner (5.2), see Figure 1, and the test specimen holder (5.3), see Figure 2, in the specified relative orientation, see Figure 3. The design shall also permit three marker threads (5.7) to be attached in the positions shown in Figure 2. At each location the marker thread is mounted as a loop so that the two segments are spaced 1 mm and 5 mm from the plane of the front of the test specimen. Each loop is attached to a different timing device (5.6.2). 5.2 Gas burner, as shown in Figure 1 and described in Annex A, capable of being moved from a standby position, where the tip of the burner is at least 75 mm from the test specimen to either the horizontal or inclined operating position, see Figure 3.

5.3 Test specimen holder, consisting of a rectangular metal frame having 12 test specimen support pins mounted along the longer edge of the rectangle of length 560 mm by width 150 mm, see Figure 2. The pins for supporting the test specimen are 5 mm, 10 mm, 190 mm, 370 mm, 550 mm and 555 mm above the bottom edge of the frame and have a minimum length of 26 mm.

NOTE Longer pins can be needed for mounting thick or multilayer test specimens. For the purpose of locating the test specimen in a plane at least 20 mm away from the frame (see 9.1.1 and 9.2.1), a spacer stub of 2 mm diameter and a length of at least 20 mm shall be positioned adjacent to each of the pins, except for the upper and lower pins on each side.

5.4 Template, flat rigid, made of a suitable material and of a size corresponding to the size of the test specimen (560 mm × 170 mm) shall be used.

Twelve holes, approximately 4 mm in diameter, are drilled along the edges of the template and positioned so that the distances between the centres of the holes correspond to the distance between the pins on the test specimen holder (see Figure 2). The holes should be located equidistant about the vertical centreline of the template.

5.5 Gas, commercial grade propane or butane or butane/propane mixtures. NOTE Commercial grade propane gas is generally used.

5.6 Timing device

5.6.1 A timing device to control and measure the flame application time and which can be set at 1 s and adjusted at 1 s intervals with an accuracy of 0,2 s or better. 5.6.2 Three timing devices reading to 0,2 s or better are required to measure the flame spread times. These devices are started simultaneously when the igniting flame is applied and are stopped automatically when the individual marker threads are severed.

5.7 Marker threads, white mercerized cotton thread having a linear density of 45 tex to 50 tex.

SIST EN ISO 6941:2026 ISO 6941:2026(en) Dimensions in millimetres Key 1 gas jet 2 burner tube 3 flame stabilizer 4 choke tube 5 notch 6 gas mixing zone 7 diffusion zone 8 air chamber 9 gas outlet a Fitted during assembly b Deburring [3] NOTE Tolerance according to ISO 2768-1-m (see ISO 2768-1 ) if not otherwise indicated. Figure 1 — Gas burner

SIST EN ISO 6941:2026 ISO 6941:2026(en) Dimensions in millimetres Key 1 third marker thread 2 second marker thread 3 test specimen 4 first marker thread 5 mounting pins 6 spacer stubs (optional) 7 burner (oriented for surface ignition) [3] NOTE Tolerance according to ISO 2768-1-m (see ISO 2768-1 ), if not otherwise indicated. Figure 2 — Test specimen holder

6 Precautions

6.1 Construction of testing equipment

Some products of combustion are corrosive. The equipment shall be constructed of material that will not be adversely affected by the fumes.

SIST EN ISO 6941:2026 ISO 6941:2026(en)

6.2 Location of test apparatus

The volume of air surrounding the test location shall be such that the test is not affected by any reduction of oxygen concentration. Where an open fronted cabinet is used for the test, provision shall be made to permit the test specimen to be mounted at least 300 mm from any wall.

6.3 Health and safety of operators

Burning of materials can produce smoke and toxic gases that can affect the health of operators. Between tests, the atmosphere of the testing location, which shall be of adequate dimensions to avoid endangering the health of operators, shall be cleared of smoke and fumes by an extractor fan or other means of ventilation (see 6.2).

NOTE Smoke and fume emission can be subjected to national regulations concerning atmospheric pollution control.

...