SIST EN 12680-4:2027
(Main)Founding - Ultrasonic testing - Part 4: Phased array ultrasonic testing of steel castings
- Abstract
This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria.
This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less.
For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels.
This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted.
In this document, phased array is used both for phased array technique and TFM technique.
- Status
- Published
- Public Enquiry End Date
- 30-Jul-2025
- Publication Date
- 22-Nov-2026
- Technical Committee
- IFEK - Ferrous metals
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 23-Nov-2026
- Due Date
- 28-Jan-2027
- Completion Date
- 23-Nov-2026
SIST EN 12680-4:2027 is a SIST standard for phased array ultrasonic testing of steel castings, published for use in foundry inspection and quality control. It specifies how to examine steel castings with low ultrasonic attenuation, including the registration levels and acceptance criteria. The document also uses phased array to cover both phased array technique and total focusing method (TFM), so it is relevant to teams that plan, perform, evaluate and report ultrasonic inspections.
What does SIST EN 12680-4:2027 specify?
SIST EN 12680-4:2027 specifies phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It applies to ferritic, bainitic and martensitic microstructures, and it sets the registration levels and acceptance criteria that are used to decide what must be recorded and what is acceptable.
The document applies to steel castings with a wall thickness of 600 mm or less. For thicker castings, the manufacturer and customer are expected to agree the test procedure and recording levels.
The scope excludes austenitic steels, cast irons, lamellar graphite cast irons, spheroidal cast irons and welded assemblies. For other ferrous materials, the document is used as guidance and the levels are adapted to the material concerned.
The document is organized into clauses on scope, normative references, terms and definitions, requirements before ordering, personnel qualification, equipment, preparation before testing, time base and sensitivity settings, test operating mode, interpretation and analysis, and the test report.
| Annex | What it covers |
|---|---|
| Annex A | Informative examples of reference blocks |
What are the key requirements of SIST EN 12680-4:2027?
SIST EN 12680-4:2027 turns phased array testing into a controlled process: the buyer and manufacturer define the inspection conditions up front, the operator works to a written procedure, the equipment and settings are checked, and the results are judged against stated recording and acceptance levels.
Ordering and planning
Before ordering, the parties need to define the examination volume, the reference and calibration blocks, access conditions, surface condition, temperature, the stage of manufacture or operation, and any extra procedure requirements. In practice, this avoids later disputes about what was inspected and under what conditions.
Clause 4 also requires a written test procedure. It has to cover the purpose and scope of testing, operating techniques, severity levels, personnel training, equipment settings, reference blocks, scan plan, indication evaluation levels, acceptance and registration levels, reporting, and environmental and safety issues.
Personnel and equipment
Personnel performing the work must be qualified in accordance with this document and have an appropriate ultrasonic testing qualification in accordance with EN ISO 9712 or an equivalent foundry-sector standard. They also need practical training and experience in phased array and TFM use, because the operator must recognize real indications and separate them from geometry.
The equipment has to comply with EN ISO 18563-1, EN ISO 18563-2 and EN ISO 18563-3 where applicable. The instrument must be able to generate beams suited to the part geometry, material structure and severity level, and it should be able to handle several settings at the same time. The document recommends an A-scan sampling frequency of at least six times the probe nominal frequency.
Probes, scan plans and preparation
Clause 7 requires a scan plan that defines the scan faces, the electronic scans, the beam laws and the mechanical movements of the probe. The plan has to ensure coverage of the full test volume. For encoded systems, the mechanical scanning step depends on wall thickness; for manual control, the speed is limited and the increment has to maintain overlap.
Surfaces must be clean, sufficiently smooth and free from materials that disturb coupling. The document gives surface-condition comparators and roughness levels that support satisfactory coupling. It also sets a practical temperature range for ordinary probes and requires a suitable coupling medium that wets the area and is used consistently for calibration and inspection.
Suitability, settings and reference blocks
The material’s suitability for phased array examination is checked by comparing a reference reflector signal, using a side-drilled hole, with background noise. The document links this check to wall thickness, so the inspector can judge whether the material is testable enough for the intended method.
Time base and sensitivity have to be set before each test and reset if the configuration changes. Clause 8 also covers gates, beam-by-beam sensitivity, wedge effects, ACG and TCG, transfer correction, and checks at the start and end of inspection. If the settings drift beyond the stated limits, the measurement chain must be checked and, where needed, the affected tests repeated.
Reference blocks have to be made from material with acoustic properties similar to the casting, and they need a minimum number of reflectors that increases with thickness. Annex A shows example block arrangements.
Evaluation, acceptance and reporting
Clause 10 requires the operator to assess image quality, identify relevant indications, classify them as punctual, flat or volumetric, size them, and compare them with the acceptance criteria. The document uses severity levels 1 to 5, and Table 6 defines acceptability limits for volume discontinuities and surface-related conditions.
Recording levels are set separately in Table 7. In practice, that means some indications must be documented even if they are not automatically unacceptable, so traceability is preserved and later review is possible. The test report then captures the casting data, extent of examination, equipment, probes, technique, sensitivity data, indication details, date, responsible person and any deviations from the standard.
What terms does SIST EN 12680-4:2027 define?
- Ultrasonic instrument - a generic term for both a phased array instrument and a TFM instrument.
- Phased array image - a one- or two-dimensional display built from collected phased array data.
- Phased array indication - a pattern or disturbance in the phased array image that may need further evaluation.
- Phased array setup - the probe arrangement defined by probe characteristics, probe position and the number of probes.
- Probe position (PP) - the probe reference point relative to the part reference point; the operator must know it to place indications correctly.
- Scan increment - the distance between successive data collection points in the scan direction.
- Active aperture - the group of active elements operated together for transmitting and/or receiving.
- Region of interest (ROI) - the two- or three-dimensional region of the test volume for which the image is computed.
Who uses SIST EN 12680-4:2027?
SIST EN 12680-4:2027 is used by foundries making steel castings, by NDT laboratories and inspection providers, and by quality managers who define or verify acceptance criteria. It also supports buyers and customers who need to specify what part of a casting is to be examined and what evidence must be reported.
In practice, it is used for inspection planning, procedure writing, equipment setup, operator qualification, scanning, indication evaluation, acceptance decisions and report preparation. It is especially relevant where wall thickness, access, surface condition and the expected microstructure affect whether phased array ultrasonic testing will give reliable results.
Which standards are used with SIST EN 12680-4:2027?
| Standard | What it contributes |
|---|---|
| EN 12680-1 | General-purpose steel casting ultrasonic testing, and source material for terms and the equivalent discontinuity echo size concept |
| EN ISO 5577 | Ultrasonic testing vocabulary |
| EN ISO 9712 | Qualification and certification of NDT personnel |
| EN ISO 16810 | General ultrasonic testing principles |
| EN ISO 18563-1 | Verification of phased array instruments |
| EN ISO 18563-2 | Verification of array probes |
| EN ISO 18563-3 | Verification of complete phased array systems |
| EN ISO 23243 | Vocabulary for ultrasonic testing with arrays |
The foreword also places this part in the EN 12680 series, alongside EN 12680-2 for steel castings for highly stressed components and EN 12680-3 for spheroidal graphite cast iron castings.
What does the SIST EN 12680-4:2027 document contain?
SIST EN 12680-4:2027 contains the full inspection workflow for phased array ultrasonic testing of steel castings: planning, equipment, preparation, calibration, scanning, evaluation and reporting. It includes a scan-plan section, equipment and probe requirements, and detailed guidance on time base, sensitivity and transfer correction.
The document also contains several practical tables used during inspection. Table 1 sets the mechanical scanning step by thickness, Table 2 gives ultrasonic testability checks, Table 3 gives correction actions when settings drift, Table 4 sets the minimum number of reference-block reflectors, Table 5 suggests active aperture and frequency ranges, Table 6 gives acceptance limits, and Table 7 gives recording levels.
Figures 1 and 2 support the method by showing the electronically covered area and the division of the wall section into zones. Annex A provides example reference blocks for straight-beam inspection, which helps laboratories and foundries build suitable calibration blocks for their own test pieces.
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.

Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 12680-4:2027 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Founding - Ultrasonic testing - Part 4: Phased array ultrasonic testing of steel castings". This standard covers: This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria. This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less. For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels. This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted. In this document, phased array is used both for phased array technique and TFM technique.
This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria. This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less. For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels. This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted. In this document, phased array is used both for phased array technique and TFM technique.
SIST EN 12680-4:2027 is classified under the following ICS (International Classification for Standards) categories: 77.140.80 - Iron and steel castings. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 12680-4:2027 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2027
Livarstvo - Ultrazvočno preskušanje - 4. del: Ultrazvočno preskušanje jeklenih
ulitkov s faznim nizom
Founding - Ultrasonic testing - Part 4: Phased array ultrasonic testing of steel castings
Gießereiwesen - Ultraschallprüfung - Teil 4: Phased-Array-Ultraschallprüfung von
Stahlgussteilen
Fonderie - Contrôle par ultrasons - Partie 4 : Contrôle par ultrasons en multiéléments de
pièces moulées en acier
Ta slovenski standard je istoveten z: EN 12680-4:2026
ICS:
77.140.80 Železni in jekleni ulitki Iron and steel castings
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 12680-4
EUROPEAN STANDARD
NORME EUROPÉENNE
November 2026
EUROPÄISCHE NORM
ICS 77.140.80
English Version
Founding - Ultrasonic testing - Part 4: Phased array
ultrasonic testing of steel castings
Fonderie - Contrôle par ultrasons - Partie 4 : Contrôle Gießereiwesen - Ultraschallprüfung - Teil 4: Phased-
par ultrasons multiéléments de pièces en acier moulé Array-Ultraschallprüfung von Stahlgussstücken
This European Standard was approved by CEN on 11 October 2026.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12680-4:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Requirements before ordering . 9
4.1 Order information . 9
4.2 Scope of examination. 9
4.3 Test procedure . 9
5 Personnel qualification . 10
6 Equipment . 10
6.1 General. 10
6.2 Ultrasonic instrument . 10
6.3 Probes . 10
6.4 Scanning mechanisms . 10
7 Preparation before testing . 10
7.1 Equipment checking . 10
7.2 Test and scan parameters . 11
7.3 Geometric considerations . 11
7.4 Preparation of scanning surfaces . 12
7.5 Temperature. 12
7.6 Coupling medium . 12
7.7 Suitability of material for phased array ultrasonic examination . 12
8 Time base and sensitivity settings . 13
8.1 Parameters . 13
8.1.1 General. 13
8.1.2 Echo selection gate . 13
8.1.3 Sensitivity setting . 13
8.1.4 Transfer correction . 13
8.2 Parameters checking . 13
8.3 Reference blocks . 14
8.3.1 General. 14
8.3.2 Material . 14
8.3.3 Reference reflectors. 14
9 Test operating mode . 15
9.1 Requirements . 15
9.2 Recommendations . 15
9.3 Data acquisition with position encoder(s) . 16
10 Interpretation and analysis of phased-array data . 16
10.1 General. 16
10.2 Assessing the quality of phased-array ultrasonic inspection data . 16
10.3 Identification of relevant (or true) indications . 17
10.4 Classification and sizing of relevant indications . 17
10.5 Recording of data collected . 17
10.6 Areas of the wall section . 17
10.7 Severity levels . 17
11 Test report . 17
Annex A (informative) Examples of reference blocks . 22
Bibliography . 23
European foreword
This document (EN 12680-4:2026) has been prepared by Technical Committee CEN/TC 190 “Foundry
technology”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by May 2027, and conflicting national standards shall be
withdrawn at the latest by May 2027.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
EN 12680-4, Founding — Ultrasonic testing — Part 4: Phased array ultrasonic testing of steel castings
This is one of four European Standards for ultrasonic testing. The other standards are:
— EN 12680-1, Founding — Ultrasonic testing — Part 1: Steel castings for general purposes;
— EN 12680-2, Founding — Ultrasonic testing — Part 2: Steel castings for highly stressed components;
— EN 12680-3, Founding — Ultrasonic testing — Part 3: Spheroidal graphite cast iron castings.
Annex A is informative.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
1 Scope
This document specifies requirements for phased array ultrasonic examination of steel castings with low
ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the
registration levels and acceptance criteria.
This document is applicable to the ultrasonic examination of steel castings with a wall thickness of
600 mm or less.
For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels.
This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast
irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration
levels and acceptance criteria are to be adapted.
In this document, phased array is used both for phased array technique and TFM technique.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 12680-1, Founding — Ultrasonic testing — Part 1: Steel castings for general purposes
EN ISO 5577, Non-destructive testing — Ultrasonic testing — Vocabulary (ISO 5577)
EN ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712)
EN ISO 16810, Non-destructive testing — Ultrasonic testing — General principles (ISO 16810)
EN ISO 18563-1, Non-destructive testing — Characterization and verification of ultrasonic phased array
equipment — Part 1: Instruments (ISO 18563-1)
EN ISO 18563-2, Non-destructive testing — Characterization and verification of ultrasonic phased array
equipment — Part 2: Array probes (ISO 18563-2)
EN ISO 18563-3, Non-destructive testing — Characterization and verification of ultrasonic phased array
equipment — Part 3: Complete systems (ISO 18563-3)
EN ISO 23243, Non-destructive testing — Ultrasonic testing with arrays — Vocabulary (ISO 23243)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 5577, EN ISO 23243 and
EN 12680-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.1
ultrasonic instrument
generic term used for both Phased Array instrument and TFM instrument
3.2
phased array image
one- or two-dimensional display, constructed from the collected information of phased array operation
[SOURCE: EN ISO 23243:2020, 3.3.2.8]
3.3
indication
phased-array indication
pattern or disturbance in the phased array image (3.2) which can need further evaluation
3.4
phased array setup
probe arrangement defined by probe characteristics (e.g. frequency, probe element size, beam angle,
wave mode), probe position (3.5), and the number of probes
[SOURCE: EN ISO 23243:2020, 3.3.1.3]
3.5
probe position
PP
position of the probe reference point relative to the part reference point
Note 1 to entry: The position of the probe reference point depends on the equipment used and shall be known by
the operator to position the indications.
3.6
scan increment
distance between successive data collection points in the direction of scanning (mechanically or
electronically)
[SOURCE: EN ISO 23243:2020, 3.3.1.5]
3.7
active aperture
group of active elements operated together when transmitting and/or receiving
[SOURCE: EN ISO 23243:2020, 3.2.1.21]
3.8
electronically covered area
width of the area covered during an electronic scanning and measured, for example, between the axis of
the first beam and the axis of the last beam of an electronic linear scanning
Note 1 to entry: See Figure 1.
3.9
total focusing technique
TFM
synthetic focusing which consists of a reconstruction, inside a ROI (3.10), to focus at many points which
form a grid (3.11), by processing part or all A-scan information of the applicable transmitter-receiver
combinations, taking into account the imaging path (3.12)
[SOURCE: EN ISO 23243:2020, 3.3.1.35, modified – Notes 1 to 3 to entry have been deleted.]
3.10
region of interest
ROI
two- or three-dimensional region, related to the test volume, for which the image is computed
[SOURCE: EN ISO 23243:2020, 3.3.2.4, modified – Notes 1 to entry has been deleted.]
3.11
grid
collection of points in the ROI (3.10) for which the image is calculated and stored, defined by the position
and relative distance between the points in a specified direction
[SOURCE: EN ISO 23243:2020, 3.3.2.5 modified – Notes 1 to 4 to entry have been deleted.]
3.12
imaging path
path that ultrasonic waves travel from transmitter to image point and from image point to receiver which
is taken into account by the imaging algorithm including refraction(s), reflection(s) and/or mode
conversion(s), if applicable
[SOURCE: EN ISO 23243:2020, 3.3.1.38]
3.13
operating mode
combination of ultrasound beams created by an array probe, e.g. fixed angle, L-scan, S-scan, Total
Focusing Technique (TFM)
3.14
equivalent discontinuity echo size
smallest indication to be recorded during the evaluation phase of an ultrasound examination, usually
expressed as the equivalent diameter of the side drilled hole
[SOURCE: EN 12680-1:2025, modified — side drilled hole instead of flat bottom hole]
Key
1 array probe
2 active aperture (grey elements)
3 moving active aperture of the electronic linear scanning
4 summed A-scan for a given shot
5 L-scan presentation
6 electronic scanning resolution
7 electronically covered area
Figure 1 — Electronically covered area
4 Requirements before ordering
4.1 Order information
The following information shall be available at the time of inquiry and order (see also
EN ISO 16810:2024, Clause 5):
a) the areas of the casting and the number or percentage of castings to which phased array ultrasonic
testing requirements apply (examination volume, extent of examination);
b) calibration and reference blocks used;
c) requirements for access, surface conditions and temperature;
d) the stage of manufacture or operation at which testing is to be carried out;
e) if there are additional requirements for the test procedure, see also Clause 7.
4.2 Scope of examination
The casting shall be tested so that the agreed areas are covered (insofar as this is possible from the shape
of the casting) by the use of the best applicable test technique.
For wall thicknesses greater than 600 mm, agreement shall be made between the manufacturer and the
customer on the severity levels, test procedure and the recording of the test results.
4.3 Test procedure
A written test procedure is required.
The procedure includes at least the following information:
a) purpose and scope of testing;
b) operating techniques;
c) severity levels;
d) personnel qualification and training requirements;
e) equipment requirements (including, but not limited to, frequency, sampling frequency, pitch between
elements, element size);
f) reference and/or calibration blocks;
g) equipment settings and checks;
h) accessibility and surface conditions;
i) scan plan;
j) indication evaluation levels;
k) acceptance and/or registration levels;
l) reporting requirements;
m) environmental and safety issues.
5 Personnel qualification
Personnel performing non-destructive testing shall be qualified in accordance with this document and
have an appropriate level of qualification in ultrasonic testing in accordance with EN ISO 9712 or an
equivalent standard in the foundry sector.
In addition to general knowledge of ultrasonic inspection of castings, operators shall also be familiar with
and have training and practical experience in the use of the phased array technique and total focusing
technique (TFM).
6 Equipment
6.1 General
Ultrasonic inspection equipment used for phased-array testing shall comply with the requirements of
EN ISO 18563-1, EN ISO 18563-2 and EN ISO 18563-3 where applicable.
6.2 Ultrasonic instrument
The ultrasonic instrument shall be able to manage the probe(s) so as to generate beams adapted to the
geometry of the part, the material structure, and the required severity level.
The ultrasonic instrument shall be able to generate several settings simultaneously, in particular for
monitoring both the background echo and the appearance of a defect echo.
Depending on the application (for example sponge shrinkages), it may be necessary to display the TFM
image at the same time as the electronic scanning in order to ensure the correct positioning of the region
of interest (ROI) and acquire simultaneously electronic scanning and TFM data.
It is recommended to use an A-scan sampling frequency of at least six times the nominal frequency of the
probe.
6.3 Probes
Both longitudinal waves and transverse waves can be used.
The probe shall take into account the surface curvature (e.g. curved wedge, flexible probe …) to transmit
the ultrasonic signal into the part.
The number of dead elements on each active aperture shall be a maximum of 1 in 16 and they shall not
be adjacent. For active aperture using fewer than 16 elements, no dead elements are permitted unless
adequate performance is demonstrated.
6.4 Scanning mechanisms
To ensure consistency of images (collected data), guidance devices and scanning encoders can be used to
communicate the position of the probe
...